• 제목/요약/키워드: Periodic Monitoring

검색결과 258건 처리시간 0.04초

가스절연개폐장치용 감시시스템 적용에 관한 연구 (A study on the Application of a Monitoring System for Gas Insulaterd Switchgear)

  • 김정배;김민수;송원표;김덕수;전찬석;길경석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권1호
    • /
    • pp.22-30
    • /
    • 2002
  • ln this paper, it was reported the developed results of the monitoring unit for 72.5kY GIS which it is one part of the monitoring system for the substation that Korea Railway Company is promoting. In order to monitor the operational status of GIS, four parameters were chosen: the number of times of the circuit breaker switching, tightness of the gas-sealed units (circuit breaker / disconnecting switch / earthing switch), the number of times of the lightning arrestor operating and the leakage current of the lighting arrester. We constructed the monitoring system that can be judged the operating condition of the GIS from the signal of the suitable sensor for the purpose. Therefore, it is possible to on line monitoring for the condition of the GlS without efforts of the Periodic inspection.

Achievements, Problems, and Future Direction of the Quality Control Program for Special Periodic Health Examination Agencies in Republic of Korea

  • Won, Yong Lim;Ko, Kyung Sun;Park, Jae Oh;Choi, Yoon jung;Lee, Hyeji;Sung, Jung-min;Lee, Mi-young
    • Safety and Health at Work
    • /
    • 제10권1호
    • /
    • pp.125-129
    • /
    • 2019
  • The ultimate goal of the quality control program for special periodic health examination agencies is to diagnose the health condition of a worker correctly, based on accurate examination and analysis skills, leading to protect the worker's health. The quality control program on three areas, chemical analysis for biological monitoring since 1995, and pneumoconiosis, audiometric testing since 1996, has contributed to improve the reliability of occupational health screenings by improving the issues including standardization of testing methods, tools, diagnostic opinions, and reliability of analysis for biological monitoring. It has contributed to improving the reliability of occupational health monitoring by rectifying the following issues associated with previous monitoring: absence of standardized testing methods, testing tools that are not upgraded, mismatching diagnostic opinions, and unreliable results of biological specimen analysis. Nevertheless, there are issues in need of further improvement such as lack of expertise or the use of inappropriate method for health examination, and passive and unwilling participation in the quality control. We suggested solutions to these problems for each area of quality control program. Above all, it is essential to provide active support for health examiners to develop their expertise, while encouraging all the health screening agencies, employers, and workers to develop the desire to improve the system and to maintain the relevance.

도시철도 실시간 모니터링 시스템 적용 사례 (Application of 5678SMRT Real-time Monitoring system)

  • 윤재관;박종헌;김기춘
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.737-747
    • /
    • 2011
  • 5678SMRT has installed various sensor for operating conditions(field of electric, facilities, signal, communication equipment and track) and environment of Every Function Room for remotely detecting and monitoring. Installed sound sensor for analyzed after remotely heard the noise of every equipment at Every Function Room and temperature sensor for check the temperature condition of Every Function Room. Additional installed voltage sensor in signal equipment room for monitoring RF track-circuit's voltage condition. Installed displacement sensor at The Chungdam bridge's railway for measuring and monitoring track displacement caused by temperature change and Pan/Tilt camera at sub-station and drainage for remotely field monitoring. Installed sensor for each equipment's operating condition and failure at Every Function Room then periodic check of workforce turned to around-the-clock surveillance by sensor therefore improvement of operating equipment. SMRT is lots of prevent a failure by Immediately detect of precondition of equipment failure by analyzed the sensor data. If the occurrence of an failure, become detected Immediately so possibility correct diagnosis and order by remotely field check by installed camera and sound sensor at field.

  • PDF

WSN에서 주기적 트래픽 처리를 위한 트래픽 제어 알고리즘 (Traffic Control Algorithm for Periodic Traffics in WSN)

  • 김정혜;이성근;고진광;박재성
    • 한국전자통신학회논문지
    • /
    • 제5권1호
    • /
    • pp.44-50
    • /
    • 2010
  • 무선 센서 네트워크는 다수의 센서 노드로 구성되며, 센서 노드들의 협력 작업을 통해 하나의 공통 작업을 수행한다. WSN 의 트래픽은 주기적인 모니터링 트래픽, 이벤트 발생 트래픽 및 쿼리 기반 트래픽으로 분류된다. 주기적인 트래픽은 발생 빈도는 낮지만, 다수의 센서노드들이 일정한 간격으로 트래픽을 생성하기 때문에 전체 트래픽 관점에서 볼 때 많은 비중을 차지하고 있다. 본 논문에서는 이러한 주기적 트래픽에 대해 에너지 효율적으로 처리하는 네트워크 프로토콜의 트래픽 제어 알고리즘을 제안하고, 이에 대한 성능 분석을 수행한다.

부식촉진시험에 의한 콘크리트 내의 철근의 부식 모니터링에 관한 실험적 연구 (An Experimental Study on the Corrosion Monitoring of Reinforcing Steel in Concrete by the Accelerated Corrosion Test)

  • 배수호;정영수;김진영
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.543-548
    • /
    • 2001
  • The corrosion monitoring methods of reinforcing steel in concrete are the various methods such as half cell potential method, galvanic current method, resistivity method, polarization resistance method, AC impedance method and etc. In this study, the corrosion monitoring methods of reinforcing steel in concrete were investigated for the test specimens using corrosion inhibitors, zinc-mortar, zinc-plate, respectively. For this purpose, the accelerated corrosion tests for reinforcing steel were conducted according to the periodic cycles(140 days) of wetting($65^{\circ}C$, 90% R.H.) and drying period(15$^{\circ}C$ , 65% R.H.) for the test specimens. As a result, it can be concluded from the test that half cell potential and galvanic current method as monitoring techniques for corrosion were found to be relatively reliable and easily usable method in the field.

  • PDF

안티몬 이온주입시 Sb2O3 빔튜닝 방법 및 모니터링 연구 (A Study on Sb2O3 Beam Tuning and Monitoring in Antimony Implantation -)

  • 김상용;최민호;김남훈;정헌상;장의구
    • 한국전기전자재료학회논문지
    • /
    • 제17권5호
    • /
    • pp.476-480
    • /
    • 2004
  • The characteristics of antimony implants are relatively well-known. Antimony has lower diffusion coefficient, shorter implantation range, and smaller scattering as compared with conventional dopants such as phosphorous and arsenic. It has been commonly used in the doping of buried layer in Bi-CMOS process. In this paper, characteristics and appropriate condition of monitoring in antimony implant beam tuning using Sb$_2$O$_3$were investigated to get a reliable process. TW(Thema Wave) and R$_{s}$(Sheet Resistance) test were carried out to set up condition of monitoring for stable operation through the periodic inspection of instruction condition. The monitoring was progressed at the point that the slant of R$_{s}$ varied significantly to Investigate the variation of instruction accurately.

Frequency analysis of GPS data for structural health monitoring observations

  • Pehlivan, Huseyin
    • Structural Engineering and Mechanics
    • /
    • 제66권2호
    • /
    • pp.185-193
    • /
    • 2018
  • In this study, low- and high-frequency structure behaviors were identified and a systematic analysis procedure was proposed using noisy GPS data from a 165-m-high tower in ${\dot{I}}stanbul$, Turkey. The raw GPS data contained long- and short-periodic position changes and noisy signals at different frequencies. To extract the significant results from this complex dataset, the general structure and components of the GPS signal were modeled and analyzed in the time and frequency domains. Uncontrolled jumps and deviations involving the signal in the time domain were pre-filtered. Then, the signal was converted to the frequency domain after applying low- and high-pass filters, and the frequency and periodic component values were calculated. The spectrum of the tower motion obtained from the filtered GPS data had dominant peaks at a low frequency of $1.15572{\times}10-4Hz$ and a high frequency of 0.16624 Hz, consistent with two equivalent GPS datasets. Then, the signal was reconstructed using inverse Fourier transform with the dominant low frequency values to obtain filtered and interpretable clean signals. With the proposed sequence, processing of noisy data collected from the GPS receivers mounted very close to the structure is effective in revealing the basic behaviors and features of buildings.

A STUDY ON WELD POOL MONITORING IN PULSED LASER EDGE WELDING

  • Lee, Seung-Key;Na, Suck-Joo
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.595-599
    • /
    • 2002
  • Edge welding of thin sheets is very difficult because of the fit-up problem and small weld area In laser welding, joint fit-up and penetration are critical for sound weld quality, which can be monitored by appropriate methods. Among the various monitoring systems, visual monitoring method is attractive because various kinds of weld pool information can be extracted directly. In this study, a vision sensor was adopted for the weld pool monitoring in pulsed Nd:YAG laser edge welding to monitor whether the penetration is enough and the joint fit-up is within the requirement. Pulsed Nd:YAG laser provides a series of periodic laser pulses, while the shape and brightness of the weld pool change temporally even in one pulse duration. The shutter-triggered and non-interlaced CCD camera was used to acquire a temporally changed weld pool image at the moment representing the weld status well. The information for quality monitoring can be extracted from the monitored weld pool image by an image processing algorithm. Weld pool image contains not only the information about the joint fit-up, but the penetration. The information about the joint fit-up can be extracted from the weld pool shape, and that about a penetration from the brightness. Weld pool parameters that represent the characteristics of the weld pool were selected based on the geometrical appearance and brightness profile. In order to achieve accurate prediction of the weld penetration, which is nonlinear model, neural network with the selected weld pool parameters was applied.

  • PDF

자기자화자왜센서를 이용한 설비 off-line Health Monitoring 시스템 개발 (Development of Health Monitoring System Using Self Magnetization Magnetostrictive Sensor)

  • 김이곤;문홍식;김준;김지현
    • 한국지능시스템학회논문지
    • /
    • 제22권4호
    • /
    • pp.481-486
    • /
    • 2012
  • 본 논문은 석유화학 플랜트 등의 결함을 자기자왜센서기술을 활용하여 주기적으로 검사하는 오프라인 모니터링이 가능한 'Health Monitoring System'의 개발과 그 활용성에 대해 확인하였다. 기존의 유도파 검사 방식은 용접부위 검사에는 적용할 수 없고, 일반적인 부위에서도 노이즈 및 반사파 등으로 검사의 정밀도에 한계를 갖고 있다. 본 기술은 주기적인 모니터링을 통해 결함의 진전에 따른 변위정보를 활용할 수 있음으로서, 더 정밀한 검사가 가능하기 때문에 석유화학 플랜트에서 매우 유용하게 활용될 수 있을 것으로 사료된다.

철도 궤도의 동특성 측정 및 건전도 모니터링 (Measurement dynamic properties of railways and health monitoring)

  • 이제필;박준홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.816-816
    • /
    • 2009
  • In order to attenuate structural waves in railway track, damped mass-spring absorber system and spring supported system are considered that are attached continuously along the beam length. A mathematical model is presented for the propagation of structural waves on a finitely long, periodically supported classical beam. The model in this paper could represent a railway track where the beam represents the rail and an appropriately chosen support type represents the pad/sleeper/ballast system of a railway track. And in this study, it is presented that the measurement method of health monitoring of railway track.

  • PDF