건설현장 화재예방에 관한 연구 - 용접작업을 중심으로 - (A Study on the Fire Prevention of the Construction Sites)

  • 목연수;장성록;이영섭;고성석
    • 한국안전학회지
    • /
    • 제17권2호
    • /
    • pp.69-75
    • /
    • 2002
  • Current fire safety in the construction sites has developed piecemeal over a considerable period of time. However, the law and regulation of fire safety is insufficient to protect fro in the construction sites. The frequency of fire in the construction sites is very rare but it brings longterm deterioration durability of building structure and large scale industrial calamity. There are many process of works and each work deals with many kind of flammable material, so it is very difficult to find a proper safety fire prevention. This study executed the questionnaire and fire experiment of the welding work to provide effective fire prevention counterplan.

Corrosion of Steel and Zinc in Tropics

  • Hue Nguyen Viet;Kwon Sik Chol
    • 한국표면공학회지
    • /
    • 제36권3호
    • /
    • pp.272-283
    • /
    • 2003
  • Mild steel and zinc specimens were tested in five atmospheric testing sites of Vietnam in order to collect the corrosion databank as well as to study the corrosion mechanism in tropical conditions, in period of 1997-2000. The results obtained showed that the corrosion rate of steel is in the range of $10-50\;{\mu}m/year$ and of zinc is of $1-5\;{\mu}m/year$. They are interpretable in the comparison with the data obtained in different countries in the South East Asian as well as previous reports of Vietnamese nation project In atmospheric corrosion. The main factors affecting the corrosion in Vietnam tropical conditions are TOW (time of wetness) and salinity. The relationship between sulfur dioxide and corrosion of metals, particularly, zinc was not found clearly. An explanation was suggested about the complex effect of different pieces present in tropical atmosphere and about the alternative of the dominant factors such as humidity, salinity or temperature.

보통전력량계(III 형)의 경년변화 특성연구 (A study on the aging characteristics for model III watthour meters)

  • 김영래;홍순학;박구범;송일근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.9-12
    • /
    • 1993
  • This study investigated the propriety and the extension of the term of validity about the using watthour meters at present. The subject of study is 1Cent 2W 220V 30(10)A, 1Cent 3W 110V 30(10)A of model III watthour meters. They are the used metes(products in 1984) and the repaired meters(products in 1977) in the end of the period. The investigation is as follows. o Investigation of external appearance o Driving current test o Creeping test o Noise test o Error test o Durability test. Results of the study have been the number of 13.3% exceeded permitting error and the number of 31.3% failed in endurable test of 500 hours. So, the using meters are not suitable to extend the term of validity without the improvement of several characteristics.

  • PDF

선형해석을 이용한 방열그릴(GRILLE)최적설계 (The Optimal Design of Vents using Linear Analysis)

  • 최용환;조여욱
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.326-332
    • /
    • 2000
  • It should be essentially considered as important points that design of case in electronic product which simultaneously satisfied with structural stability and molding form in respect to developmental period and economical aspect. Especially, a shape of air vents grille, which is made to emit heat happen to be in the internal of product, must satisfy durability and strength but We have no quantitative data because to be done by experience of designer. So, in this study, We will propose that structure of optimal and method of design in air vents grille, which to reduce a lot of loss of time and cost due to trial and error of design and to stabilize in the BALLISTIC Impact test as to estimate strength with external appearance of product, using linear analysis.

  • PDF

조강형 재료를 사용한 초조강 콘크리트의 적용성 평가 (Evalution of Practial Application of high early Strength Concrete using Early strength type material)

  • 양훈;박규연;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.48-49
    • /
    • 2013
  • This test investigates early strength and durability of concrete using early strength type materials(cement, Polycarboxylate acid). The goal of this test is to secure the strength of 5.0 MPa in 12 hours early age and strength of 14 MPa for 24 hours correspondingly. This type of admixtures, concrete curing temperature, amount of binder and other concrete properties were confirmed by experimental factors. Comparing outcomes from two cases on using early strength type materials and common materials resulted in reducing of costs and shortening of the construction period, that determined the economical benefits of using early strength materials in construction.

  • PDF

Long term monitoring of a cable stayed bridge using DuraMote

  • Torbol, Marco;Kim, Sehwan;Shinozuka, Masanobu
    • Smart Structures and Systems
    • /
    • 제11권5호
    • /
    • pp.453-476
    • /
    • 2013
  • DuraMote is a remote sensing system developed for the "NIST TIP project: next generation SCADA for prevention and mitigation of water system infrastructure disaster". It is designed for supervisory control and data acquisition (SCADA) of ruptures in water pipes. Micro-electro mechanical (MEMS) accelerometers, which record the vibration of the pipe wall, are used detect the ruptures. However, the performance of Duramote cannot be verified directly on a water distribution system because it lacks an acceptable recordable level of ambient vibration. Instead, a long-span cable-stayed bridge is an ideal test-bed to validate the accuracy, the reliability, and the robustness of DuraMote because the bridge has an acceptable level of ambient vibration. The acceleration data recorded on the bridge were used to identify the modal properties of the structure and to verify the performance of DuraMote. During the test period, the bridge was subjected to heavy rain, wind, and a typhoon but the system demonstrates its robustness and durability.

회귀분석을 이용한 전자접촉기의 접점소모 분석에 대한 고찰 (A study on Analysis of Contact erosion at a Magnetic Contactor with the Use of Regression Analysis)

  • 김명석;유행수;한규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.116-118
    • /
    • 2003
  • This paper describes a Accelerated Life Test (ALT) with the electrical contact erosion suitable to the evaluations of high-reliability and durability devices such as magnetic contactor. Recently, an electrical devices company was interested in accelerated life test (ALT), the product liability (PL) and the short-term testing model of electrical life test (ELT). In order to estimate a model for testing fee and period, need to the statistical analysis method with the acceleration factor(AF). Usually customer/manufacturer regard their device failure to the over-current or heavy duty condition, while devices view shape of contact erosion owing to operational duty problem. In this paper, additional method of evaluation estimated the operated cycles by weight of contact erosion with a used of regression analysis by MINITAB.

  • PDF

현대주거건축론을 통해 본 외관표현에 관한 연구 - 대구지역을 중심으로 - (A study on the expression in elevation in through theory of contemporary house - focused on the Taegu province -)

  • 정명섭
    • 한국주거학회논문집
    • /
    • 제5권2호
    • /
    • pp.77-86
    • /
    • 1994
  • The attempts in pursuit of humanity in contemporary architecture brought about meaning to the 'Locality as a main conception which opens new potentiality at this confused period. Contemporary housing design should meet the indigenous ‘Locality’ of the building sites environment. An adequate adaptation to the ‘Locality’ will bring more efficient use, lower running-costs, and longer durability of original beauty of the houses. Our contemporary houses should admit general requirements at this time and they should be expressed through not only space but also form and design. Finally, we must find the direction of elevation planning of Korean contemporary houses, inquiring into design elements of ‘Locality’ in the view point of transformation and analyzing how the elements are represented in contemporary houses. This research was aimed to find how to optimize an elevation design of houses in adapting to the Korean indigenous ‘Locality’ in order to create a domestic housing design suitable for Korean life style, however, one cannot ignored elements of the Korean traditional mode of living.

  • PDF

ADVANCES IN DESIGN AND RESIDUAL LIFE CALCULATION WITH REGARD TO REBAR CORROSION OF REINFORCED CONCRETE

  • C. Andrade;D. Izquierdo;J. Rodriguez;L Ortega
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.15-30
    • /
    • 2005
  • The increasing amount of structures presenting distress due to reinforcement corrosion is urging the establishment of more accurate calculation methods for the service life of concrete structures. In the present paper, a summary of the different approaches is presented that are able to calculate the expected life of new structures, in certain aggressive environments or the residual life of already corroding structures. The methods for the initiation period are based on the proper calculation of the carbonation front or chloride penetration and on the steel corrosion rate. The methods for the residual load-bearing capacity calculations are based in the use of ' indicators ' or in the evaluation of the reduced section and a structural recalculation.

  • PDF

각종증착금속면의 응축열전달에 관한 연구 (A Study on Condensation Heat Transfer to Some Evaporated Metal Surface)

  • 조시기;이기우;박영재;조명재
    • 대한설비공학회지:설비저널
    • /
    • 제15권2호
    • /
    • pp.188-195
    • /
    • 1986
  • Condensation heat transfer can be classified in dropwise condensation and filmwise condensation, and for the industrial purpose, the former is more useful than the latter because of the higher heat transfer rate. But it is difficult to maintain the dropwise condensation continuously since most of the metal surfaces become wetted after exposure to a condensing vapor over an extended period of time. To maintain dropwise condensation continuously , various surface coatings and promoters have been used recently, but these methods must be reconsidered about the durability of condensing surface. Therefore, in this study, evaporating method of various pure metals on the condensing surface has been performed to maintain dropwise condensation. The results have showed that the heat transfer rate of silver evaporating surface is higher than any other metal evaporating in dropwise area. Transition temperature and filmwise condensation curves are uniform regardless of kinds of evaporating metals.

  • PDF