• Title/Summary/Keyword: Perimodiolar

Search Result 3, Processing Time 0.017 seconds

Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

  • Lee, Ji Young;Hong, Sung Hwa;Moon, Il Joon;Kim, Eun Yeon;Baek, Eunjoo;Seol, Hye Yoon;Kang, Sihyung
    • Journal of Audiology & Otology
    • /
    • v.23 no.3
    • /
    • pp.145-152
    • /
    • 2019
  • Background and Objectives: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Subjects and Methods: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. Results: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. Conclusions: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.

Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

  • Lee, Ji Young;Hong, Sung Hwa;Moon, Il Joon;Kim, Eun Yeon;Baek, Eunjoo;Seol, Hye Yoon;Kang, Sihyung
    • Korean Journal of Audiology
    • /
    • v.23 no.3
    • /
    • pp.145-152
    • /
    • 2019
  • Background and Objectives: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Subjects and Methods: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. Results: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. Conclusions: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.

Positive Peaked Electrically Compound Action Potentials in Cochlear Implant Recipients (인공와우 이식자에서 Positive Peaked 청신경 복합활동전위)

  • Heo, Seung-Deok
    • Phonetics and Speech Sciences
    • /
    • v.1 no.2
    • /
    • pp.25-30
    • /
    • 2009
  • Animal experiments have shown that the positive peaked electrically compound action potentials (ECAPs) can be recorded in round window, intracochlear, and nerve trunk by stimulating a monopolar pulse. However, positive peaked ECAPs of cochlear implant recipients have never been reported because ECAPs are recorded from intracochlear electrodes after bipolar stimulation. In our experiment, the positive peaked ECAPs were recorded from 18 intracochlear electrodes in cochlear implant recipients with multiple cochlear anomalies. Thresholds in each channel were measured and the latency of P-, N-wave, and amplitude of P-N were analyzed. These results were identical with the electrically auditory brainstem response (EABR) on the input-output characteristics. In conclusion, the positive peaked ECAPs from the cochlear implant recipients are antidromic ECAPs recorded by perimodiolar electrodes stimulating cochlear implants with multiple anomalies. Therefore, positive peaked ECAPs can be used as useful audiological tools to evaluate the eighth nerve ending.

  • PDF