• 제목/요약/키워드: Peri-implant

검색결과 310건 처리시간 0.023초

상악 단일 치아 임프란트의 후향적 연구 (A Retrospective study on upper single tooth implants)

  • 조수진;이근우;조규성;문익상
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.383-393
    • /
    • 2003
  • The aim of this retrospective study was to compare the amount of marginal bone loss between upper anterior area and upper posterior area with 71 upper single-tooth restorations on 2 stage machined $Br{{\aa}}nemark$ implants since Jan 1995. The second aim was to compare the bone defect group which had dehiscence and fenetration and the others in the upper anterior region. The results were as follows. 1. The most frequent reason of missing tooth in the upper anterior region was trauma by 61%. While upper posterior region showed various reasons such as congenital missing, advanced periodontitis, trauma. 2. Peri-implantitis with fistula occurred 1 of 41 implants in the upper anterior group in 1 year after loading and 2 of 32 implants in the upper posterior group failed before loading. The 1 year success rate of upper anterior group was 97.56 %, and 93.75 % for upper posterior group. 3. The mean marginal bone loss in the upper anterior group was 0.44${\pm}$0.25 mm, while 0.57${\pm}$0.32 mm in the upper posterior group. There was statistically significant difference in the amount of mean marginal bone loss (P${\pm}$0.10 mm at one year, and 0.48${\pm}$0.26 mm for the control group. No statistically significant difference of mean marginal bone loss was showen between bone defect group and the others at implantation. According to the results, the upper anterior region showed less marginal bone loss than the upper posterior region. In case of missing single upper tooth, careful consideration on recipient residual ridge to determine proper implant diameter and length, sufficient healing time, proper loading would lead to implant success. Single tooth implants in the maxilla seemed to be an alternative to fixed partial dentures without damage to adjacent teeth.

혈소판 유래 성장인자가 임플란트 주위 골형성에 미치는 효과에 대한 실험적 연구 (AN EXPERIMENTAL STUDY OF PLATELET-DERIVED GROWTH FACTOR ABOUT BONE FORMATION IN DENTAL IMPLANT)

  • 류재준;권종진;김한겸
    • 대한치과보철학회지
    • /
    • 제36권6호
    • /
    • pp.816-831
    • /
    • 1998
  • Bony fixation of implants during the early phase of healing is important in order to get secondary stability of the implant assuring the success of the treatment. Because the successful placement of the implant is limited by the quality and quantity of bone, other agents which stimulate bone formation in the peri-implant spaces has been illustrated. Platelet-derived growth factor (PDGF) has been shown to regulate DNA and protein synthesis in bone cells in vitro and to interact synergistically to enhance soft tissue wound healing in vivo. The purpose of this study was to evaluate bone promotion around implants which were augmented with sagittal split osteotomy or autogenous veneer bone graft using the platelet derived growth factor(PDGF). After placement of newly designed twenty four screw-type implants, which were 12mm in length and 4mm in diameter in 6 dogs. $4{\mu}g$ of PDGF B/B was applied with surgicel carriers. The dogs were sacrificed at 3 days, 1, 2, 3, 6, and 12 weeks after implantation. Specimens were examined clinically, radiographically, histologically, and histomorphometrically. The results were as follows: 1. Clinically and radiologically, there was no significant difference in bone formation and healing pattern between experimental and control group. 2. In autogenous veneer bone graft group, bone formation was observed at 1st week in the experimental groups but 2nd week in the control groups. At 3rd week, the expeimental groups showed more bone formation comparing to the control groups. 3. In sagittal split osteotomy group, bone formation was observed at 1st week in both groups. But the experimental groups showed more bone formation comparing to the control groups after 2nd week. 4. The bone growth rate of experimental group was more rapid than that of control group. These results indicated that PDGF did not affect the initiation of new bone formation, but it accelerated the bone formation at the early period.

  • PDF

The effect of peri-implant bone exposure on soft tissue healing and bone loss in two adjacent implants

  • Shin, Seung-Yun;Kye, Seung-Boem;Hong, Jong-Rak;Paeng, Jun-Young;Yang, Seung-Min
    • Journal of Periodontal and Implant Science
    • /
    • 제42권1호
    • /
    • pp.20-24
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the soft tissue and bone change around two adjacent implants in onestage implant surgery. Methods: Eleven subjects (7 males, 4 females) who were needed placement of 2 adjacent implants in the molar area were included. The two implants were placed with the platform at the level of the alveolar crest. The interproximal bone between the 2 implants was not covered with gingiva. After surgery, an alginate impression was taken to record the gingival shape and radiographs were taken to evaluate implant placement. Using a master cast, the gingival height was measured at baseline, 4 weeks, and 12 weeks. In the radiograph, the alveolar bone level was measured at the mesial and distal side of both implants at baseline and 12 weeks. Results: The exposed bone was covered with gingiva at both 4 and 12 weeks. Loss of alveolar bone around implants was found in all areas. The alveolar bone level in the exposed bone area did not differ from that in the non-exposed area. Conclusions: This study showed that the alveolar bone level and gingival height around 2 adjacent implants in the exposed bone area did not differ from that in unexposed bone area.

임플랜트 보철물의 나사구멍 봉쇄방법이 지대나사 풀림에 미치는 영향에 관한 연구 (THE EFFECT OF SCREW HOLE SEALING METHOD ON ABUTMENT SCREW LOOSENING IN DENIAL IMPLANT)

  • 임재빈;임순호;조인호
    • 대한치과보철학회지
    • /
    • 제35권4호
    • /
    • pp.767-780
    • /
    • 1997
  • One of the most common problems of implant prosthesis is the screw loosening of abutment screws. This brings on discomfort in mastication, inflammation in the peri-implant tissue due to poor oral hygiene and fracture of prosthesis or loss of osseointegration. To prevent screw loosening, appropriate implantation to direct the occlusal force to the long axis of the implant, accurate design of the superstructure, decrease of the occlusal table, and adequate torque on the abutment screw are necessary. In this study the screw loosening torque was evaluated in implants with dimples or flutes in the internal surface of abutment screw holes. The abutments were fastened with slot type and hexagonal type abutment screws and were sealed with vinyl poly siloxane impression and bite registration material respectively. The screw loosening torque was evaluated after 1,800 and 12,600 times loading under a loading machine. The results were as follows. 1. The flute form group showed significantly higher loosening torque compared to the dimple form group and the group with no inner surface treatment (p<0.05). 2. There was no statistical difference in loosening torque according to the sealing materials. 3. The loosening torque according to the types of abutment screw showed no significant difference. 4. The loosening torque was significantly higher after 1800 times loading compared to 12600 times loading(p<0.05). From the above results. it is thought that formation of a flute in the internal surface of the screw hole decreases the chance of screw loosening, but the sealing materials and types of abutment screw did not show significant difference in prevention of screw loosening.

  • PDF

덮개 나사 조기 노출이 임플란트의 생존율에 미치는 영향 (Effect of the early exposure of cover screws on the survival rate of implants)

  • 김용건;이재관;장범석;엄흥식
    • Journal of Periodontal and Implant Science
    • /
    • 제36권4호
    • /
    • pp.879-889
    • /
    • 2006
  • The early exposure of cover screws is a common complication of 2-stage implant technique. The exposure of cover screws between stage I and IT surgery may cause inflammation in the soft tissues surrounding the implants, and lead to peri-implantitis or marginal bone loss. The purpose of this study was to evaluate the effect of the early exposure of cover screws on implants placed using 2-stage technique. Two hundred and nineteen implants in 77 patients were examined for cumulative survival rate, radiographic marginal bone level change, cause and frequency of the early exposure. The results were as follows: 1. Twenty-five implants showed early exposure of cover screws with a frequency of 11.4%. 2. Cumulative survival rate of the implants with early cover screw exposure was 88.0%, and that of the implants without cover screw exposure was 96,9%. 3. At the time of stage IT surgery and 1 year after loading, the marginal bone loss was greater around the implants with early exposure of cover screws than around the implants without cover screw exposure(p <0.05), 4, There was no statistically significant difference in the frequency of the early exposure according to the implant diameter, gender, and smoking(p >0,05).

염산테트라싸이클린이 임플란트 표면에 미치는 효과;주사전자현미경적 연구 (Effect of Application of Tetracycline - HCl on Implant Surface;Scanning Electron Microscopic Study)

  • 홍정아;허익;이만섭;박준봉
    • Journal of Periodontal and Implant Science
    • /
    • 제31권2호
    • /
    • pp.333-344
    • /
    • 2001
  • The present study was performed to evaluate the effect of tetracycline - HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface and titanium plasma-sprayed surface were utilized. Implant surface was rubbed with 50mg/ml tetracycline - HCl solution for 1 min., $1\frac{1}{2}\;min$., 2 min., $2\frac{1}{2}\;min$. and 3min. respectively in the test group and with saline for 1 min. in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. Pure titanium machined surfaces conditioned with saline for 1 min., showed a few shallow grooves and ridges and were less irregular. 2. Pure titanium machined surfaces conditioned with 50mg/ml tetracycline - HCl solution showed more irregular and corrosive surfaces compared to the control group irrespective of the application time of tetracycline - HCl solution. 3. Titanium plasma-sprayed surfaces conditioned with saline for 1 min., were deposited with round amorphous particles and showed round or irregular pores that can be connected to each other. 4. The irregularity of titanium plasma-sprayed surfaces conditioned with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas were wider relative to the application time of tetracycline - HCl solution. 5. Titanium plasma-sprayed surfaces conditioned with tetracycline - HCl solution for 1 min. and $1\frac{1}{2}\;min$. were very similar to that of the control group, but the surfaces conditioned for 2 min., $2\frac{1}{2}\; min$. and 3 min. were changed. In conclusion, pure titanium machined surfaces were changed irrespective of the application time of tetracycline - HCl solution. And titanium plasma-sprayed surfaces conditioned with tetracycline - HCl solution began to be changed from $1\frac{1}{2}\;min$. This results will be applicable to the regenerative procedures for peri-implantitis treatment.

  • PDF

Chitosan/hydroxyapatite composite coatings on porous Ti6Al4V titanium implants: in vitro and in vivo studies

  • Zhang, Ting;Zhang, Xinwei;Mao, Mengyun;Li, Jiayi;Wei, Ting;Sun, Huiqiang
    • Journal of Periodontal and Implant Science
    • /
    • 제50권6호
    • /
    • pp.392-405
    • /
    • 2020
  • Purpose: Titanium implants are widely used in the treatment of dentition defects; however, due to problems such as osseointegration failure, peri-implant bone resorption, and periimplant inflammation, their application is subject to certain restrictions. The surface modification of titanium implants can improve the implant success rate and meet the needs of clinical applications. The goal of this study was to evaluate the effect of the use of porous titanium with a chitosan/hydroxyapatite coating on osseointegration. Methods: Titanium implants with a dense core and a porous outer structure were prepared using a computer-aided design model and selective laser sintering technology, with a fabricated chitosan/hydroxyapatite composite coating on their surfaces. In vivo and in vitro experiments were used to assess osteogenesis. Results: The quasi-elastic gradient and compressive strength of porous titanium implants were observed to decrease as the porosity increased. The in vitro experiments demonstrated that, the porous titanium implants had no biological toxicity; additionally, the porous structure was shown to be superior to dense titanium with regard to facilitating the adhesion and proliferation of osteoblast-like MC3T3-E1 cells. The in vivo experimental results also showed that the porous structure was beneficial, as bone tissue could grow into the pores, thereby exhibiting good osseointegration. Conclusions: Porous titanium with a chitosan/hydroxyapatite coating promoted MC3T3-E1 cell proliferation and differentiation, and also improved osseointegration in vitro. This study has meaningful implications for research into ways of improving the surface structures of implants and promoting implant osseointegration.

Periosteum-attached Autogenous Block Bone Graft with Simultaneous Implant Placement on the Anterior Maxilla: A Case Report

  • Seung-Hyun Park;Jongseung Kim;Ui-Won Jung;Jae-Kook Cha
    • Journal of Korean Dental Science
    • /
    • 제17권2호
    • /
    • pp.64-74
    • /
    • 2024
  • This case report presents the long-term radiographic outcomes of a novel approach for simultaneous lateral augmentation and implant surgery. A 60-year-old male patient who required tooth extraction of the maxillary central and lateral incisors due to trauma visited the clinic. After tooth extraction, severe horizontal and vertical deficiencies occurred owing to atrophy of the alveolar ridge, and a simultaneous guided bone regeneration (GBR) procedure was planned along with the installation of two implants. In the present case, a modification of the conventional 'sandwich technique' was used by placing the mixture of autogenous bone chips and xenografts at the outermost layer to maximize the osteogenic potential at the coronal part of augmentation while applying solely xenografts at the inner layer. To enhance volumetric stability, an autogenous block of periosteum harvested from the maxillary tuberosity was incorporated between the two layers. Cone-beam computed tomography was performed at baseline and 3 years after the surgery to compare radiographic outcomes. Dehiscence after fixture installation was successfully observed at the re-entry of the surgery site. Three years after the surgery, average horizontal bone gains of 6.11 mm and 4.12 mm were observed in the maxillary central and lateral incisor areas, respectively. Healthy peri-implant mucosa and well maintained marginal bone levels were observed 8 years after the surgery, meeting the criteria for implant success. The findings of this case suggest that a substantial amount of horizontal bone gain can be obtained with a layered approach using autogenous bone materials and xenografts, highlighting the advantages of incorporating autogenous blocks into the simultaneous GBR procedure.

두 종류의 임플란트 시스템을 이용한 하악의 미니-임플란트지지 피개의치 수복 증례 (Mandibular implant supported overdentures with two different mini-implant systems: A case report)

  • 박진홍;이정열;류재준;신상완
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.267-272
    • /
    • 2016
  • 본 증례는 치조골의 흡수가 심한 두 명의 완전무치악 환자에서 서로 다른 임플란트 시스템을 이용한 하악의 미니-임플란트 지지 피개의치에 대한 증례보고이다. 두 환자는 하악 의치의 유지력 부족으로 인한 의치 사용시 불편감 및 동통을 주소로 호소하였다. 각각의 환자는 4개의 미니 임플란트를 이공사이에 판막의 거상없이 식립하였다. 첫번째 증례는 미니볼 어태치먼트와 일체형으로 된 미니-임플란트(Slimline, Dentium, Seoul, Korea)를 식립하고 구강내 직접법으로 어태치먼트를 연결하여 즉시하중을 시행하였다. 두번째 증례는 분리형으로 로케이터 어태치먼트와 연결되는 미니-임플란트(LODI, Zest Anchors, Escondido, CA, USA)를 이용하였으며, 임플란트 식립 8주 후 간접법으로 어태치먼트를 연결하였다. 최종 의치 장착 후 6개월 정기검진까지 미니볼과 로케이터 어태치먼트를 이용한 하악의 미니-임플란트 지지 피개의치 증례에서 환자의 전반적인 만족도가 개선되었으며 주목할 만한 합병증 없이 만족할 만한 임상적 결과를 얻었다. 단 추후 지속적인 유지관리 및 장기적인 평가가 더 필요하리라 사료된다.

염산티트라싸이클린의 적용시간에 따른 다공성 임프란트 표면 미세구조의 변화 (Microstructural Change of Porous Surface Implant conditioned with Tetracycline-hydrochloride)

  • 정재욱;허익;권영혁;박준봉;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.319-334
    • /
    • 2006
  • Mechanical and chemical methods are the two ways to treat the implant surfaces. By using mechanical method, it is difficult to eliminate bacteria and by-products from the rough implant surface and it can also cause the structural change to the implant surface. Therefore, chemical method is widely used in order to preserve and detoxicate the implant surface more effectively. The purpose of this study is to evaluate the effect of tetracylcline-hydrochloride(TC-HCI) on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and porous surface were used in this study. Implant surface was rubbed with sponge soaked in 50mg/ml TC-HCI solution for $\frac{1}{2}$ min., 1 min., $1\frac{1}{2}$ min., 2 min., and $2\frac{1}{2}$ min. respectively in the test group and with no treatment in the control group. Then, specimens were processed for scanning electron microscopic observation. 1. Both test and control group showed a few shallow grooves and ridges in pure titanium machined surface implants. There were not significant differences between two groups. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. Subsequently, the acid-etching process created the micro roughness, which thus was superimposed on the macro roughness. Irrespective of the application time of 50mg/ml TC-HCI solution, in general, test specimens were similar to control. 3. In the porous surfaces, the control specimen showed spherical particles of titanium alloy and its surface have a few shallow ridges. The roughness of surfaces conditioned with tetracycline-HCI was lessened and seen crater-like irregular surfaces relative to the application time. In conclusion, pure titanium machined surfaces and SLA surfaces weren't changed irrespective of the application time of tetracycline-HCI solution. But the porous surfaces conditioned with tetracycline-HCI solution began to be slightly changed from 2 min. This results are expected to be applied to the regenerative procedures for peri-implantitis treatment.