• 제목/요약/키워드: Performence Evaluation

검색결과 4건 처리시간 0.022초

DEA를 활용한 차세대첨단콘텐츠육성사업 참여 DMU의 효율성 평가에 관한 사례 연구 (A Case Study on Efficiency Evaluation of DMUs Performances for Digital Pioneer Project by Data Envelopment Analysis Model)

  • 신재식;양해술
    • 한국IT서비스학회지
    • /
    • 제6권1호
    • /
    • pp.65-81
    • /
    • 2007
  • Recently, the affiliates of the Ministry of Information and Communication have been conducting a performance evaluation study on IT policy projects, based on the performance evaluation model of the U.S. Office of Management and Budgets, with regard to investment in computerization. The performance evaluation model for the policy project could provide the objective information required for the planning, development, and operation of the policy project. However, the performance of the most policy project is likely to be evaluated using the subjective evaluation criteria of evaluators. Therefore, this case study evaluates the relative efficiency using DEA (Data Envelopment Analysis) in order to improve the performance evaluation method of the digital pioneer' project implemented by the Korea IT Industry Promotion Agency. The improvement value of inefficient Decision Making Units (DMUs) was measured by a static efficiency analysis. The measured value will suggest a objective viewpoint of the performance between DMUs to evaluators. In doing so, it will show an appropriate direction for the policy project to be evaluated successfully.

600V급 GaN FET의 스위칭 특성 분석 및 성능 평가 (Switching Characteristic Analysis and Performence Evaluation of 600V GaN FET)

  • 임종헌;김재원;박준성;김진홍;최준혁
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.279-280
    • /
    • 2019
  • 본 논문에서는 3KW급 전력변환장치에 적용 가능한 650V급 GaN FET를 사용하여 Half-bridge 구조의 개발보드를 설계 및 제작하고, Double pulse test 실험을 통해 Turn-on 및 off 시스위칭 특성을 분석하였다. 또한 동기정류식 Buck 컨버터에 GaN FET을 적용하고, 유사한 전압 및 전류 정격의 Si MOSFET 소자와 시스템 효율을 비교하여 GaN FET 전력반도체의 성능을 평가하였다.

  • PDF

Evaluation of Mixing Conditions for the Production of Optimized High Flowing Concrete

  • Kim, Sang-Chel
    • KCI Concrete Journal
    • /
    • 제11권3호
    • /
    • pp.79-88
    • /
    • 1999
  • Most difficulties of inducing high fluidity on the concrete mixing design with a strength range of 210 to 240kg/$\textrm{cm}^2$ result from the segregation of aggregates due to the shortage of cementitious binders. To solve the problem, this study concentrated on finding the optimized amount of binder material which does not affect the concrete strength and is also economical. Also there were studies on the use of intermediate sized aggregates to avoid the gap-grading between coarse and fine aggregates so that the material segregation in high flowing concrete was and minimalized the fluidity and penetration capacity of the reinforcing bars was enhanced. Throughout the parametric study with respect to water/binder ratio. superplasticizer. replaceable mineral admixture, the size of coarse aggregate and mixing methods, the effect of each constituent on the characteristics of high flowing concrete could be observed. As a result or partially using stone powder or an intermediate class of aggregate (max. diameter 13mm) . it was fund that the fluidity of concrete significantly increased without material segregation and any change of compressive strengths. It was also proved in this study that proper mixing time and speed are significant factors influence the performence of high flowing concrete.

  • PDF

긴급시공이 가능한 FRP 내진보강재로 보강된 기둥의 내진성능평가 실험 (An Experimental Study on Seismic Performance Evaluation of Retrofitted Column of FRP Seismic Reinforcement that can be Emergency Construction)

  • 김진섭;권민호;서현수;임정희;김동영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권6호
    • /
    • pp.21-30
    • /
    • 2013
  • 최근 발생한 대규모 지진으로 구조물의 내진보강에 대한 사회적 관심도가 높아지고 있다. 특히 내진설계가 반영되지 않은 기둥의 경우 지진에 의한 횡하중을 저항하지 못하고, 취성적인 파괴가 유발되어 구조물 전체적 붕괴를 유발할 수 있다. 따라서 빠른 시간내에 보강이 가능하면서 기둥에 손상을 주지 않는 기존의 보강법과 구별되는 응급 보강법이 필요하다. 과거에는 기둥 보강법으로 단면 증설법과 강판보강법 등이 개발되어 현장에 적용되었지만, 최근에는 FRP (Fiber Reinforced Polymer)의 장점을 활용한 탄소섬유시트공법이 많이 사용되고 있다. 본 연구에서는 긴급시공이 가능한 체결식 FRP 내진보강재를 사용한 구조물의 내진성능보강효과를 검토하고자 하였다. 검토를 위하여 실제 구조물의 축소모델의 철근콘크리트 시험체를 제작하고 횡방향 변위하중을 가력하였다. FRP 내진보강재를 이용한 내진보강시공 후 실내시험을 통하여 내진성능을 평가하였다. 그 결과 개발된 보강재의 철근콘크리트 구조물에 보강 시, 내진성능이 향상됨을 확인하였다.