• 제목/요약/키워드: Performance-based structural fire design

검색결과 52건 처리시간 0.021초

내화강재 적용 단순 보부재의 고온 거동 비교 연구 (Comparative Study of Beams made up of Fire Resistant Steels)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.111-112
    • /
    • 2017
  • Fire is very serious condition in steel based structures. Therefore, to enhance the structural stability of columns and beams in high temperatures, fire resistant steels and TMC fire resistant steels are developed from steel manufacturing companies. In this study to evaluate the structural stability and compare the resistant performance, a fire engineering design method was applied and fire resistant steels showed the better performance than other two materials.

  • PDF

성능위주설계를 위한 화재감지기배치의 공학적연구 (Automatic Fire Detector Spacing Calculation for Performance Based Design)

  • 박동하
    • 한국화재소방학회논문지
    • /
    • 제24권1호
    • /
    • pp.15-23
    • /
    • 2010
  • 현재의 화재안전기준에서 규정하는 화재감지기의 배치방법은 면적에 따라 규정된 숫자를 적정하게 배치하는 수준이다. 이 기준은 과학적인 근거는 가지고 있지 못하다. 외국의 기준을 도입하여 그에 따라서 설치하고 있을 뿐이다. 소방시설을 설계하는 방법에는 화재안전기준과 같이 명문화 된 규정에 따르는 규범위주설계(Prescriptive-based)와 화재역학, 구조역학, 재료역학, 유체역학, 열역학 등 공학적 지식을 바탕으로 하는 성능위주설계(Performance-based design)가 있다. 현재로서는 성능위주설계가 활성화 되지 않았지만, 최근 소방시설공사업법은 성능위주설계방법을 이용하여 소방시설을 설계 할 수 있도록 개정('05. 8. 4)되었으며 그 시행령('07, 1. 24)에서 성능위주설계를 적용할 특정소방대상물의 범위를 정하고 있다. 이러한 시점에서 자동화재탐지설비의 화재감지기를 최적의 위치 및 거리에 설치하기 위하여 그에 대한 공식의 도입과 공식을 Software로 계산할 수 있도록 시뮬레이터를 제작하여 계산하고 규범위주설계에 따라 배치한 화재감지기의 상태와 비교 분석하며 향후 성능위주설계 방법으로서 정착시키기 위하여 연구를 시도하였다.

하중비에 따른 강재 보의 한계온도에 관한 실험적 연구 (Experimental Study on Limiting Temperatures of Structural Beams made with Structural Steel According to Load Ratios)

  • 권인규
    • 한국강구조학회 논문집
    • /
    • 제22권6호
    • /
    • pp.581-588
    • /
    • 2010
  • 최근 강구조 건축물에 대한 상온 및 화재 시의 구조거동에 관한 요구사항이 증대되는 추세에 있으며, 내화구조에 관한 요구조건을 충족시키기 위해서는 내화설계가 요구된다. 내화설계에는 법규, 기준 등에 따라 평가되는 시방적 내화설계와 화재 발생 시 구조물 거동을 평가하는 성능기반 공학적 내화설계로 대별된다. 현재 성능기반 공학적 내화설계는 세계적인 추세로 활발히 적용되고 있으나, 국내에서는 아직 적용되지 못하는 실정이다. 따라서 본 논문에서는 성능 기반 공학적 내화설계의 지침 마련의 기반자료 확보를 위하여 H-형강 보부재와 H형강의 웨브에 콘크리트로 충전된 보부재를 대상으로 한계온도 설정을 목적으로 한다. 재하가열시험을 통하여 H-형강 보부재의 한계온도를 도출하였고, 한계온도는 적용 하중비에 좌우되는 것을 확인하였다. H-형강 웨브에 콘크리트가 충전된 하중비 80%, 60% 및 50%의 시험체는 모두 3시간의 내화성능을 보였다.

각형 강관기둥부재의 한계온도 평가 연구 (Evaluation of Limiting Temperatures of Rectangular Hollow Sections)

  • 권인규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.331-332
    • /
    • 2012
  • Structural steel has been used as a primary materials to columns and beams since 1960's in Korea with an advantages of excellent of load-bearing capacity and design flexibility, and faster construction. However, if the steel columns made of structural steel exposed to fire the load-bearing capacity is going down steadily and finally reach to collapse. Therefore, building regulation requires fire resistance according to building occupation, scales. The fire resistance can be evaluated two categories. One is prescriptive method that is based on building regulation, specification and so on and the other is performance-based fire engineering method. The latter can be designed based on scientific and engineering consequences. The easiest evaluation way using the fire engineering design is comparing to the limiting temperature and maximum temperature calculated based on heat transfer theory. If the limiting temperature of a column exceeds the maximum temperature of it, the column can carry the load during the fire. Therefore, the database of limiting temperature is very essential for evaluation of column. In this paper, to build the database of column made of rectangular hollow sections 8 fire tests with loading were conducted and the relation between the limiting temperature and the applied loads showed in reverse proportion.

  • PDF

Performance Based Fire Engineering in Japan

  • Kohno, Mamoru;Okazaki, Tomohito
    • 국제초고층학회논문집
    • /
    • 제2권1호
    • /
    • pp.23-30
    • /
    • 2013
  • This paper explains the Japanese present situations relevant to the fire resistance performance. Performance-based fire provisions was introduced in 1998 for the first time when the Building Standard Law was amended. However, performance-based fire resistance design had been used since long before the official introduction of performance-based provisions. A Comprehensive Technology Development Project of Ministry of Construction from 1982 to 1986 established a technical basis for performance-based fire safety engineering in Japan. A system of calculation methods for fire resistance verification was prescribed in the Ministry Notification in 2000 utilizing the results of this project as a background. This method, referred to as the Fire Resistance Verification Method (FRVM), is the standard method to verify the fire resistance performance of principal building parts such as columns, beams, and walls of steel, concrete, or wood structured buildings. For tall buildings, however, more advanced method for performance verification is often necessary because new building materials or structural systems are often used for these buildings. An example project of tall building owned by a major newspaper company is presented in this paper. Advanced thermal deformation analysis is executed to secure the fire resistance of the building.

Performance of steel beams at elevated temperatures under the effect of axial restraints

  • Liu, T.C.H.;Davies, J.M.
    • Steel and Composite Structures
    • /
    • 제1권4호
    • /
    • pp.427-440
    • /
    • 2001
  • The growing use of unprotected or partially protected steelwork in buildings has caused a lively debate regarding the safety of this form of construction. A good deal of recent research has indicated that steel members have a substantial inherent ability to resist fire so that additional fire protection can be either reduced or eliminated completely. A performance based philosophy also extends the study into the effect of structural continuity and the performance of the whole structural totality. As part of the structural system, thermal expansion during the heating phase or contraction during the cooling phase in most beams is likely to be restrained by adjacent parts of the whole system or sub-frame assembly due to compartmentation. This has not been properly addressed before. This paper describes an experimental programme in which unprotected steel beams were tested under load while it is restrained between two columns and additional horizontal restraints with particular concern on the effect of catenary action in the beams when subjected to large deflection at very high temperature. This paper also presents a three-dimensional mathematical modelling, based on the finite element method, of the series of fire tests on the part-frame. The complete analysis starts with an evaluation of temperature distribution in the structure at various time levels. It is followed by a detail 3-D finite element analysis on its structural response as a result of the changing temperature distribution. The principal part of the analysis makes use of an existing finite element package FEAST. The effect of columns being fire-protected and the beam being axially restrained has been modelled adequately in terms of their thermal and structural responses. The consequence of the beam being restrained is that the axial force in the restrained beam starts as a compression, which increases gradually up to a point when the material has deteriorated to such a level that the beam deflects excessively. The axial compression force drops rapidly and changes into a tension force leading to a catenary action, which slows down the beam deflection from running away. Design engineers will be benefited with the consideration of the catenary action.