• Title/Summary/Keyword: Performance-based HR

Search Result 184, Processing Time 0.028 seconds

Nail Withdrawal Resistance and Embedding Strength of Structural Wood Panels with Water Absorption (수분의 흡수에 따른 구조용 목질판넬의 인발 및 함입성능)

  • 오세창
    • Journal of the Korea Furniture Society
    • /
    • v.10 no.2
    • /
    • pp.1-8
    • /
    • 1999
  • The use of structural wood based panels like plywood, OSB in many applications involves the use of nails, and data on the performance of panel-nail connection are needed for design and comparative purpose. This study was carried out to develop basic information on nail performance(withdrawal, embedding, nailhead push through) with water absorption in plywood and OSB. In withdrawal resistance test, initial stiffness of plywood performed better than OSB in 24hr soaked condition. The soaked condition reduced average nail withdrawal resistance value about 46% (12d mail), 53%(8d nail) in OSB, 17%(12d mail), 24%(8d mail) in plywood. The nail embedding strength of plywood also performed better than that of OSB and retention value(wet strength/dry strength) yielded similar in each nail types. The nail head push through capacity of OSB was higher than that of plywood in dry condition, but equal or lower in soaked condition. Therefore, critical consideration about structural panels is required in moist applications. The average values of nail withdrawal, nail embedding strength and nail head push through resistance of tested materials meet the minimum requirement of various specification and standards.

  • PDF

Hydraulic Evaluation and Performance of On-Site Sanitation Systems in Central Thailand

  • Koottatep, Thammarat;Eamrat, Rawintra;Pussayanavin, Tatchai;Polprasert, Chongrak
    • Environmental Engineering Research
    • /
    • v.19 no.3
    • /
    • pp.269-274
    • /
    • 2014
  • On-site sanitation systems are typically installed to treat grey and toilet wastewaters in areas without sewer and centralized treatment systems. It is well known that, due to inappropriate design and operation, treatment performance of these systems in developing countries is not satisfactory in the removal of pathogens and organic matters. This research aimed to investigate the hydraulic conditions occurring in some on-site sanitation systems and the effects of hydraulic retention times (HRTs) on the system performance. The experiments were conducted with a laboratory-scale septic tank (40L in size) and an actual septic tank (600L in size), to test the hydraulic conditions by using tracer study with HRTs varying at 12, 24 and 48 hr. The experimental results showed the dispersion numbers to be in the range of 0.017-0.320 and the short-circuit ratios in the range of 0.014-0.031, indicating the reactors having a high level of sort-circuiting and approaching complete-mix conditions. The removal efficiency of $BOD_5$ was found to be 67% and the $k_{30}$ values for $BOD_5$ was $2.04day^{-1}$. A modified complete-mix model based on the relationship between $BOD_5$ removal efficiencies and HRTs was developed and validated with actual-scale septic tank data having a correlation coefficient ($R^2$) of 0.90. Therefore, to better protect our environment and minimizing health risks, new generation toilets should be developed that could minimize short-circuiting and improving treatment performance.

Study on the Standard Oxygen Transfer Efficiency Monitoring System in the Aeration Tank for Reuse and Discharge of Wastewater (하폐수의 재사용 및 방류를 위한 폭기조 내 표준산소전달 효율 모니터링 시스템에 관한 연구)

  • Kim, Hong-Seok;Kim, Yong-Beom;Ko, Kyung-Han;Kim, Sang-Woo;Shim, Hwan-bo
    • Resources Recycling
    • /
    • v.28 no.6
    • /
    • pp.73-78
    • /
    • 2019
  • In this investigation, off-gas generated from the activated sludge in wastewater treatment plant was monitored. Through monitoring, the oxygen transfer efficiency in the aeration system and the reliability was evaluated by comparing to clean water. First, the dissolved oxygen, oxygen transfer coefficient, and standard oxygen transfer efficiency were measured based on clean water, and the values were 8.60 mg/L, 9.490/hr and 23.96%, respectively. The off-gas monitoring at the wastewater treatment plant indicated that the standard oxygen transfer efficiency was 22.81%. Little difference in oxygen transfer efficiency this data inferred that the performance was improved through diffuser installation in the field monitoring system.

A Study on the Optimal Design and Performance Analysis of the Solid-Gas Chemical Heat Transformer (고-기 화학열변환기의 최적설계 및 성능해석에 관한 연구)

  • Choi, S.H.;Lee, S.I.;Baek, I.H.;Choi, I.S.
    • Applied Chemistry for Engineering
    • /
    • v.8 no.5
    • /
    • pp.729-736
    • /
    • 1997
  • For the recovery of industrial waste heat, a chemical heat transformer based on the reversible reaction between metal chlorides and ammonia gas was designed and a pilot scale unit of 1 kW-1hr was developed. A static calculation, which determined the amount of reacting materials and operating condition of system, and dynamic simulations were performed for the optimal design. The temperature and output power of generator in the system were varying with the amount of salt and heat exchange area. Optimum conditions such as the amount of salt-graphite, apparent density and size of mechanical unit were determined by the dynamic simulation for the system. According to the operating cycle of 4 stages, experimental results of temperature and output power were well agreed with the simulation values. This chemical heat transformer is turned out to be a very promising system for recovery of industrial waste heat because of its effective feature of lifting temperature.

  • PDF

Assessment of Dust Reduction in the Enclosed Pig Building by Spraying Method with Liquid Additives (액상 첨가제 살포 방법에 의한 밀폐형 돈사에서의 분진 저감 평가)

  • Kim, K.Y.;Ko, Han-Jong;Kim, C.N.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.97-104
    • /
    • 2008
  • Appropriate air quality in the pig building is essential to prevent farmers' health as well as to increase pig performance. This on-site experiment was conducted to assess dust reduction efficiencies of several liquid additives with spaying method in the enclosed pig building. The mean reduction rate of total dust only after spray was approximately 30% for all the treatments compared to initial level before spraying additives, which was found to reduce the initial level of total dust significantly (p<0.05). The mean reduction rate of all the treatments at 1hr after spray was about 24% which was 6% lower than only after spray. Since 3hr after spray, however, total dust level were fluctuated variably for all the treatments besides application of the soybean oil. Based on this result, effect of soybean oil on dust reduction in the enclosed pig building was most prominent among liquid additives evaluated in terms of efficiency and duration.

  • PDF

Bioequivalence Assessment of Nabumetone Tablets in Healthy Korean Volunteers

  • Park, Moon-Hee;Shin, In-Chul
    • Biomolecules & Therapeutics
    • /
    • v.15 no.2
    • /
    • pp.118-122
    • /
    • 2007
  • This study was performed to evaluate the bioequivalency between the Osmetone$^{TM}$ Tablet (Myeongmoon Pharm. Co., Ltd.) as a test formulation and the Relafen$^{TM}$ Tablet (Handok Pharm. Co., Ltd.) as a reference formulation. Twenty-four healthy male volunteers were administered the formulations by the randomized Latin square crossover design, and the plasma samples were determined by a high performance liquid chromatography (HPLC) with Ultra-Violet (UV) detector. AUC$_t$, C$_{max}$ and T$_{max}$ were obtained from the time-plasma concentration curves, and log-transformed AUC$_t$ and C$_{max}$ and log-untransformed T$_{max}$ values for two formulations were compared by statistical tests and analysis of variation. AUC$_t$ was determined to be 897.8${\pm}$431.1 ug.hr/ml for the reference formulation and 902.3${\pm}$408.4 ug.hr/ml for the test formulation. The mean values of C$_{max}$ for the reference and test formulations were 24.2${\pm}$8.9 and 24.0${\pm}$9.5 ug/ml, respectively. The AUC$_t$ and C$_{max}$ ratios of the reference Relafen$^{TM}$ Tablet to the test Osmetone$^{TM}$ Tablet were +5.01% and -0.83%, respectively, showing that the mean differences were satisfied the acceptance criteria within 20%. The results from analysis of variance for logtransformed AUC$_t$ and C$_{max}$ indicated that sequence effects between groups were not exerted and 90% confidence limits of the mean differences for AUC$_t$ and C$_{max}$ were located in ranges from log 0.80 to log 1.25, satisfying the acceptance criteria of the KFDA bioequivalence. The Osmetone$^{TM}$ Tablet as the test formulation was considered to be bioequivalant to the Relafen$^{TM}$ Tablet used as its reference formulation, based on AUC$_t$ and C$_{max}$ values.

DESIGN AND PERFORMANCE EVALUATION OF A CABBAGE LOADER

  • Chang, Y.C.;Cho, S.I.;Yeo, Y.W.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.480-488
    • /
    • 2000
  • Cabbage is the most important vegetables in korea. The cabbage production was based on arduous human labor. A comprehensive research for substituting the human work by machines has been performed at present. In general, cabbage is cultivated on hillside in korea. The harvested cabbage in a field and carrying it to a vehicle for transportation are very laborious work. Hand labor in cabbage transportation to the market damages the quality of cabbage and is also a cause to increase the cost of cabbage production. This study was to design and evaluate a prototype cabbage loader for deserving efficient and safe transportation of cabbage. The developed cabbage loader was a semi-tracked vehicle operated by a hydraulic system, allowing the safe transporting and the loading of cabbage in a steep field. The maximum loading capacity of the loader was 1.0 ton. By using safety devices attached to the loader, the static slopes were 34.0% and 37.4% for the left and the rear roll-over, respectively. The maximum field speed was about 6km/hr with two cabbage pallets of 750kg at a 25% inclined field. The field capacity was about 35 pallets/hr in case of picking up, carrying and unloading two cabbage pallets. The field efficiency of the loader was analyzed to be more than 8 times in comparison of the conventional human labor. The developed loader would be applied for loading and carrying the other vegetables due to the similarity of operations. The study suggested a standard approach to the design of field machines operated in a steep field.

  • PDF

Bioequivalence Assessment of Roxithromycin Tablets in Healthy Korean Volunteers

  • Kwon Oh-Seung;Kim Hye-Jung;Pyo Hee-Soo;Chung Youn-Bok
    • Biomolecules & Therapeutics
    • /
    • v.14 no.1
    • /
    • pp.50-55
    • /
    • 2006
  • The objective of the study was to evaluate the bioequivalency between the $Rozid^{TM}$ Tablet (Ilhwa Pharm. Co., Ltd.) as a test formulation and the $Rulid^{TM}$ Tablet (Handok Pharm. Co., Ltd) as a reference formulation. Twenty-four healthy male volunteers were administered the formulations by the randomized Latin square crossover design, and the plasma samples were determined by a high performance liquid chromatography (HPLC) with fluorescence detector. $AUC_t,\;C_{max}\;and\;T_{max}$ were obtained from the time-plasma concentration curves, and log-transformed $AUC_t\;and\;C_{max}$ and log-untransformed $T_{max}$ values for two formulations were compared by statistical tests and analysis of variation. $AUC_t$ was determined to be $63.30{\pm}25.57{\mu}g.hr/ml$ for the test formulation and $64.02{\pm}29.27mg.hr/ml$ for the reference formulation. The mean values of $C_{max}$ for the test and reference formulations were $5.07{\pm}2.14\;and\;5.53{\pm}2.60{\mu}g/ml$, respectively. The $AUC_t,\;and\;C_{max}$ ratios of the test $Rozid^{TM}$ Tablet to the reference $Rulid^{TM}$ Tablet were -1.12% and -8.32%, respectively, showing that the mean differences were satisfied the acceptance criteria within 20%. The results from analysis of variance for log-transformed $AUC_t,\;and\;C_{max}$ indicated that sequence effects between groups were not exerted and 90% confidence limits of the mean differences for $AUC_t,\;and\;C_{max}$ were located in ranges from log 0.80 and log 1.25, satisfying the acceptance criteria of the KFDA bioequivalence. The RozidTM Tablet as the test formulation was considered to be bioequivalent to the RulidTM Tablet used as its reference formulation, based on $AUC_t,\;and\;C_{max}$ values.

Study of Characterization for Lean NOx Trap Catalysts Utilizing a Bench-Flow Reactor System (Bench-Flow Reactor System을 이용한 Lean NOx Trap 촉매의 특성 연구)

  • Yoon, Cheon-Seog;Kim, Hak-Yong;Nguyen, Ke
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.179-189
    • /
    • 2008
  • The performance of Lean NOx Trap (LNT) based on the catalysts of Pt/K/Ba/$\gamma-Al_2O_3$ with proprietary washcoat formulation is studied using a bench flow reactor system. To investigate the effect of temperature and gas hourly space velocity (GHSV) on the nitrogen oxides (NOx) trapping capacity as well as NOx breakthrough time and final ratio of $NO_2$ to NO of LNT, series of adsorption isotherms are carried out with simulated exhaust gases of the lean burn engines. Since typical operation of LNT requires periodic regeneration with a short rich excursion, where the stored or trapped NOx is released and subsequently reduced to $N_2$, the effect of the duration of lean and rich phase and type of reductants on the NOx conversion is investigated. NOx storage capacity and breakthrough time obtained from adsorption isotherms shows a volcano-type dependence on the temperature with a maximum NOx storage capacity occurring $350^{\circ}C$ and with a maximum breakthrough time occurring $400^{\circ}C$ at all GHSVs investigated in this study. Also, maximum ratio of $NO_2$ to NO is obtained at $400^{\circ}C$ with a GHSV of $75,000\;hr^{-1}$ Lean/rich cycle of 100 s lean and 5 s rich used with a concentration of 1.33% of $H_2$ and 4% of CO in the rich phase is found to be optimum at operating temperature of $350^{\circ}C$ and a GHSV of $50,000\;hr^{-1}$.

Investigation of the Performance of Spectral Domain Optical Doppler Tomography with High-speed Line Scanning CMOS Camera and Its Application to the Blood Flow Measurement in a Micro-tube

  • Park, Cheol Woo;Lee, Changho;Lim, SooHee;Ni, Aleksey;An, Jin Hyo;Lee, Ho;Bae, Jae Sung;Kim, Jeehyun
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.174-180
    • /
    • 2012
  • In this study, the feasibility of spectral domain optical Doppler tomography for measuring blood flow characteristics in a micro-tube was demonstrated through several experiments. The use of an SD-ODT system in blood flow measurement can provide high resolution images (5 microns resolution). We prepared three capillary tubes to reveal the effect of different concentrations of hematocrit ratio (HR). One tube serves as the control. The two other tubes contained different concentrations of HR (5%, 25%). Three different capillary tube inlet flow velocities were tested in the present study. The Reynolds number (Re) which is based on the capillary tube inner diameter ranges from Re=6 to 48. We calculated a Doppler shift of the power spectrum of the temporal interference fringes with Kasai autocorrelation function to achieve the velocity profile of the flow. As a result, SD-ODT systems could not detect the cell depletion layer in the present study due to the limitation of spatial resolution. Nevertheless, these systems were proven to be capable of observing the RBCs of blood.