• 제목/요약/키워드: Performance-base

검색결과 3,272건 처리시간 0.03초

Wavelet analysis of soil-structure interaction effects on seismic responses of base-isolated nuclear power plants

  • Ali, Shafayat Bin;Kim, Dookie
    • Earthquakes and Structures
    • /
    • 제13권6호
    • /
    • pp.561-572
    • /
    • 2017
  • Seismic base isolation has been accepted as one of the most popular design procedures to protect important structures against earthquakes. However, due to lack of information and experimental data the application of base isolation is quite limited to nuclear power plant (NPP) industry. Moreover, the effects of inelastic behavior of soil beneath base-isolated NPP have raised questions to the effectiveness of isolation device. This study applies the wavelet analysis to investigate the effects of soil-structure interaction (SSI) on the seismic response of a base-isolated NPP structure. To evaluate the SSI effects, the NPP structure is modelled as a lumped mass stick model and combined with a soil model using the concept of cone models. The lead rubber bearing (LRB) base isolator is used to adopt the base isolation system. The shear wave velocity of soil is varied to reflect the real rock site conditions of structure. The comparison between seismic performance of isolated structure and non-isolated structure has drawn. The results show that the wavelet analysis proves to be an efficient tool to evaluate the SSI effects on the seismic response of base-isolated structure and the seismic performance of base-isolated NPP is not sensitive to the effects in this case.

Self-centering passive base isolation system incorporating shape memory alloy wires for reduction in base drift

  • Sania Dawood;Muhammad Usman;Mati Ullah Shah;Muhammad Rizwan
    • Smart Structures and Systems
    • /
    • 제31권5호
    • /
    • pp.531-543
    • /
    • 2023
  • Base isolation is one of the most widely implemented and well-known technique to reduce structural vibration and damages during an earthquake. However, while the base-isolated structure reduces storey drift significantly, it also increases the base drifts causing many practical problems. This study proposes the use of Shape Memory Alloys (SMA) wires for the reduction in base drift while controlling the overall structure vibrations. A multi-degree-of-freedom (MDOF) structure along with base isolators and Shape-Memory-Alloys (SMA) wires in diagonal is tested experimentally and analytically. The isolation bearing considered in this study consists of laminates of steel and silicon rubber. The performance of the proposed structure is evaluated and studied under different loadings including harmonic loading and seismic excitation. To assess the seismic performance of the proposed structure, shake table tests are conducted on base-isolated MDOF frame structure incorporating SMA wires, which is subjected to incremental harmonic and historic seismic loadings. Root mean square acceleration, displacement and drift are analyzed and discussed in detail for each story. To better understand the structure response, the percentage reduction of displacement is also determined for each story. The result shows that the reduction in the response of the proposed structure is much better than conventional base-isolated structure.

L형 갈고리 앵커볼트를 사용한 약축방향 노출형 주각부의 내진성능 평가 (Seismic Evaluation of Exposed Column-base Plate Weak-axis Connections Using L-shaped Hooked Anchor Bolts)

  • 임우영;유영찬
    • 한국강구조학회 논문집
    • /
    • 제29권4호
    • /
    • pp.269-280
    • /
    • 2017
  • 본 연구에서는 기존 소규모 철골조에서 나타나는 현장상세 노출형 주각부와 이를 보완한 상세를 가진 약축방향 주각부에 대한 반복 가력 실험을 통해 다양한 상세를 가진 약축방향 노출형 주각부의 내진성능을 평가하였다. 실험변수는 베이스 플레이트의 두께, 앵커볼트의 개수와 매립깊이, 그리고 리브 플레이트의 유무이다. 앵커볼트의 부착성능이 주각부 내진성능에 미치는 영향을 알아보기 위해 본 연구에서는 원형강봉과 나사산이 있는 L형 갈고리 앵커볼트를 사용하였다. 실험결과, 앵커볼트의 부착성능과 베이스 플레이트의 항복유무는 주각부의 에너지 소산능력에 영향을 끼치는 것으로 나타났다. 특히, 베이스 플레이트가 현행 기준에서 제시하고 있는 최소 두께를 만족하더라도 강재 기둥이 소성모멘트에 도달하기 전 베이스 플레이트가 항복할 경우, 주각부의 구조성능이 저하될 수 있는 소지가 있는 것으로 나타났다. 하지만, 현행 구조기준에 따라 접합부 성능을 조사한 결과, 제안된 약축방향 주각부 상세는 부분 강접합으로 가정할 수 있는 것으로 나타났다. 기존의 원형강봉에 비해 부착성능이 우수한 나사산이 있는 L형 갈고리 앵커볼트는 반강접 노출형 주각부에 사용가능할 것으로 판단된다.

Lyapunov-based Semi-active Control of Adaptive Base Isolation System employing Magnetorheological Elastomer base isolators

  • Chen, Xi;Li, Jianchun;Li, Yancheng;Gu, Xiaoyu
    • Earthquakes and Structures
    • /
    • 제11권6호
    • /
    • pp.1077-1099
    • /
    • 2016
  • One of the main shortcomings in the current passive base isolation system is lack of adaptability. The recent research and development of a novel adaptive seismic isolator based on magnetorheological elastomer (MRE) material has created an opportunity to add adaptability to base isolation systems for civil structures. The new MRE based base isolator is able to significantly alter its shear modulus or lateral stiffness with the applied magnetic field or electric current, which makes it a competitive candidate to develop an adaptive base isolation system. This paper aims at exploring suitable control algorithms for such adaptive base isolation system by developing a close-loop semi-active control system for a building structure equipped with MRE base isolators. The MRE base isolator is simulated by a numerical model derived from experimental characterization based on the Bouc-Wen Model, which is able to describe the force-displacement response of the device accurately. The parameters of Bouc-Wen Model such as the stiffness and the damping coefficients are described as functions of the applied current. The state-space model is built by analyzing the dynamic property of the structure embedded with MRE base isolators. A Lyapunov-based controller is designed to adaptively vary the current applied to MRE base isolator to suppress the quake-induced vibrations. The proposed control method is applied to a widely used benchmark base-isolated structure by numerical simulation. The performance of the adaptive base isolation system was evaluated through comparison with optimal passive base isolation system and a passive base isolation system with optimized base shear. It is concluded that the adaptive base isolation system with proposed Lyapunov-based semi-active control surpasses the performance of other two passive systems in protecting the civil structures under seismic events.

기기면진 기반 원전 내진성능 상향 타당성 검토 (Feasibility Study for Seismic Performance Enhancement of NPP Based on Equipment Base Isolation)

  • 이진형;신태명;구경회
    • 한국압력기기공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.88-95
    • /
    • 2018
  • In this study, to enhance the seismic performance of nuclear power plants (NPP), a small laminated rubber bearing (LRB) is chosen as a seismic design option of the vulnerable equipment. Prior to the application of equipment base isolation, it is necessary to review the feasibility that the technique contributes enough to the seismic performance of NPP by analysis. At first, some preliminary design of small LRBs for equipment is carried out. Design parameters such as horizontal and vertical stiffnesses, design natural frequencies are checked by calculation and analysis for the four design options considering various upper weights. Performance test of small LRB is to be carried out to verify static performance using the results.

An experimental study on different socket base connections under cyclic loading

  • Pul, Selim;Husem, Metin;Arslan, Mehmet Emin;Hamzacebi, Sertac
    • Computers and Concrete
    • /
    • 제13권3호
    • /
    • pp.377-387
    • /
    • 2014
  • This paper presents an experimental study on socket base connections of precast reinforced concrete columns. The main purpose of this study is to determine socket base connection which has the closest behavior to monolithic casted column-base joints. For this purpose, six specimens having different column-socket base connection details were tested under cyclic loading. For each test, strength, stiffness, ductility and drift ratios of the specimens were determined. Test results indicated that a suggested connection type is 10%-30% stronger than the other type of connections under lateral loading. The welded connection (PC-5) had better lateral load carrying capacity and ductility. On the other hand, performance of standard connection (PC-1) which is commonly used in construction was weaker than other connections. Thus, decision of connection type should be referred not only performance but also applicability.

Experimental Study on Seismic Performance of Base-Isolated Bridge

  • Chung, Woo Jung;Yun, Chung Bang;Kim, Nam Sik;Seo, Ju Won
    • 한국지진공학회논문집
    • /
    • 제2권3호
    • /
    • pp.51-60
    • /
    • 1998
  • Base isolation is an innovative design strategy that provides a practical alternative for the seismic design of structures. Base isolators, mainly employed to isolate large structures subjected to earthquake ground excitations and to rehabilitate structures damaged by past earthquakes, deflect and absorb the seismic energy horizontally transmitted to the structures. This study demonstrated that the base isolation system may offer effective performance for bridges during severe seismic events through shaking table tests. Two base isolation systems using laminated rubber bearings with and without hydraulic dampers are tested. The test results strongly show that the laminate rubber bearings cause the natural period of the bridge structure increased considerably, which results in the deck acceleration and the shear forces on the deck acceleratino and the shear forces on the piers reduced significantly. The results also demonstrate that the hydraulic dampers enhance the system's capacity in dissipating energy to reduce the relative displacement between the bridge deck and the pier.

  • PDF

표준 탄도모델 기반 항력감소탄의 모터 자료 결정에 관한 연구 (A Study on Determination of Motor Data of a Base-Bleed Projectile based on Standard Ballistic Model)

  • 박용인;이치훈;고영성
    • 한국군사과학기술학회지
    • /
    • 제27권1호
    • /
    • pp.31-42
    • /
    • 2024
  • In this study, the methodology of determination of base bleed motor data for base bleed projectile based on the NATO standard trajectory model, especially STANAG 4355 Method 2 were presented. Ground combustion experiments and aerodynamic performance firing tests were conducted to determine the drag reduction motor data of the base bleed projectile and this data was described based on the NATO standard ballistic model. The derived drag reduction motor data were input into the ballistic equations to complete the ballistic model and it was confirmed that the calculated predicted trajectory from the ballistic model matched well with the measured trajectory from the aerodynamic performance firing tests.

Seismic isolation performance sensitivity to potential deviations from design values

  • Alhan, Cenk;Hisman, Kemal
    • Smart Structures and Systems
    • /
    • 제18권2호
    • /
    • pp.293-315
    • /
    • 2016
  • Seismic isolation is often used in protecting mission-critical structures including hospitals, data centers, telecommunication buildings, etc. Such structures typically house vibration-sensitive equipment which has to provide continued service but may fail in case sustained accelerations during earthquakes exceed threshold limit values. Thus, peak floor acceleration is one of the two main parameters that control the design of such structures while the other one is peak base displacement since the overall safety of the structure depends on the safety of the isolation system. And in case peak base displacement exceeds the design base displacement during an earthquake, rupture and/or buckling of isolators as well as bumping against stops around the seismic gap may occur. Therefore, obtaining accurate peak floor accelerations and peak base displacement is vital. However, although nominal design values for isolation system and superstructure parameters are calculated in order to meet target peak design base displacement and peak floor accelerations, their actual values may potentially deviate from these nominal design values. In this study, the sensitivity of the seismic performance of structures equipped with linear and nonlinear seismic isolation systems to the aforementioned potential deviations is assessed in the context of a benchmark shear building under different earthquake records with near-fault and far-fault characteristics. The results put forth the degree of sensitivity of peak top floor acceleration and peak base displacement to superstructure parameters including mass, stiffness, and damping and isolation system parameters including stiffness, damping, yield strength, yield displacement, and post-yield to pre-yield stiffness ratio.

Polyolester base oils과의 상호작용에 의한 Organic Phosphates계 내하중첨가제의 마모방지 성능 (The antiwear performance of several organic phosphates from the aspect of interaction between polyolester base oil and additive)

  • 한두희
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.189-194
    • /
    • 1999
  • The antiwear performance of several organic phosphates ,such as tricrecylphosphate(TCP), tributylphosphate(TBP), diphenylhydrogenphosphate(DPHP) ,dissolved in polyol ester based oils is studied. These organic phosphates are well known for antiwear additive for lubricating oil that produce reacted surface protective film. These antiwear additives can drastically reduce wear with their concentration increasing, because the amount of additive adsorbed on metal sur(ace increases. But in the higher concentration region, the wear is increased by excessive and corrosive reaction of the metal surface with these additives. That is to say, there is an optimum concentration for minimum wear. The optimum concentration was different with the kinds of base oils and additives. Different polyolesters showed different optimum concentrations of the additive. The order of optimum concentration among the polyolesters was different with different phosphates. The order of the optimum concentration is shown that the effect of the concentration of additives on the antiwear performance. It can be explained by the interaction between additives and base oils using the solubility parameter.

  • PDF