• Title/Summary/Keyword: Performance testing

Search Result 3,498, Processing Time 0.031 seconds

A study on railway performance test management program building based on X-internet (X- 인터넷 기반의 철도성능시험관리 프로그램 구축에 관한 연구)

  • Ohn, Jung-Ghun;Kim, Myung-Ryoung;Yang, Doh-Chul
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.2096-2100
    • /
    • 2008
  • This research project management, building systems to test the performance requirements of a user to accept the plan and schedule management, personnel management, and test results, and the status of testing and reporting procedures to handle the process of implementation of Java-based X - Under the Internet environment, the default network, remote process research and development program as a test automation, structure and each module of the software analysis, design, analysis and clean-up and structure of the modules, each module and the GUI structure, performance, testing integration DB The present system is to study the system.

  • PDF

Long-term Mechanical Behavior of CFRP-strengthened Steel Members for a Truss Tower

  • Nakamoto, Daiki;Yoresta, Fengky Satria;Matsui, Takayoshi;Mieda, Genki;Matsuno, Kazunari;Matsumoto, Yukihiro
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.4
    • /
    • pp.343-349
    • /
    • 2020
  • This research aimed to clarify the long-term mechanical performance of a steel truss member strengthened by a carbon fiber-reinforced polymer (CFRP) without protective coating through exposure testing. Strengthening and repair methods using CFRP have been developed in recent years; however, there is a lack of durability research for CFRP-strengthened members, especially mechanical performance investigation according to actual exposure testing. In this study, 10 CFRP-strengthening steel specimens were created in 2015, and elastic bending tests were conducted biannually. Eventually, although resin loss occurred due to environmental effects, the mechanical performance of CFRP-strengthened steel was not degraded, and we propose a calculation method of bending stiffness to evaluate the lower value of stiffness for design.

Wind-lens turbine design for low wind speed

  • Takeyeldein, Mohamed M.;Ishak, I.S.;Lazim, Tholudin M.
    • Wind and Structures
    • /
    • v.35 no.3
    • /
    • pp.147-155
    • /
    • 2022
  • This research proposes a wind-lens turbine design that can startup and operate at a low wind speed (< 5m/s). The performance of the wind-lens turbine was investigated using CFD and wind tunnel testing. The wind-lens turbine consists of a 3-bladed horizontal axis wind turbine with a diameter of 0.6m and a diffuser-shaped shroud that uses the suction side of the thin airfoil SD2030 as a cross-section profile. The performance of the 3-bladed wind-lens turbine was then compared to the two-bladed rotor configuration while keeping the blade geometry the same. The 3-bladed wind-lens turbine successfully startup at 1m/s and produced a torque of 66% higher than the bare turbine, while the two-bladed wind-lens turbine startup at less than 4m/s and produced a torque of 186 % higher than the two-bladed bare turbine at the design point. Findings testify that adding the wind-lens could improve the bare turbine's performance at low wind speed.

A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems (이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰)

  • Park, Jun-Hyun;Kang, Tae-Seok;Kim, Jae-Hwan;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.26-32
    • /
    • 2015
  • Carbon dioxide principally extinguishes fires by smothering, but an acceptable amount of extinguishing agent is needed. To assure the performance of carbon dioxide systems in Korea, computer programs certified by NEMA are being applied in system design. But the design errors can occur because the geometry of a model test facility is not the same as that of the actual fire area. Since the discharge rate tends to vary considerably with the flow pattern in a pipe, an on-site discharge test is necessary to ensure the performance of the system, especially with low pressure carbon dioxide. Technical standards for carbon dioxide systems do not give detailed guidelines for discharge tests at present. Based on comparative analysis of standards and practical tests, this paper suggests a methodology for on-site discharge tests.

Development of a Multi-Channel Ultrasonic Testing System for Automated Ultrasonic Pipe Inspection of Nuclear Power Plant (원전 배관 자동 초음파 검사를 위한 다채널 초음파 시스템 개발)

  • Lee, Hee-Jong;Cho, Chan-Hee;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.145-152
    • /
    • 2009
  • Currently almost all in-service-inspection techniques, applied in domestic nuclear power plants, are partial to field inspection technique. These kinds of techniques are related to managing nuclear power plants by the operation of foreign-produced inspection devices. There have been so many needsfor development of native in-service-inspection device because there is no native diagnosis device for nuclear power plant inspection yet in Korea. In this research, we developed several core techniques to make an automated ultrasonic pipe inspection system for nuclear power plants. A high performance multi-channel ultrasonic pulser/receiver module, an A/D converter module and a digital main CPU module were developed and the performance of the developed modules was verified. The S/N ratio, noise level and signal acquisition performance of the developed modules showed proper level as we designed in the beginning.

Developing a Drug Information Leaflet of Antihypertensives for Senior Citizens; Employing Performance-based User-testing (수행능력 기반 사용자 평가를 활용한 노인용 고혈압치료제 안전사용설명서 개발)

  • Kim, Jin;Lee, Iyn-Hyang
    • Korean Journal of Clinical Pharmacy
    • /
    • v.26 no.3
    • /
    • pp.254-263
    • /
    • 2016
  • Objective: Written information could be helpful for senior population to adhere to complex medication therapies, but must be well prepared and empirically assessed to achieve such end. We purposed to develop a drug information leaflet for senior citizens by applying 'performance-based user-testing.' Methods: We employed a user-testing, a mixed method to figure difficulties out with patients' leaflets from the user perspective. The cycle made of test and revision can be repeated as necessary. We recruited senior citizens with age of 65 or above who were taking antihypertensive medications at the point of participating and excluded the elderly who suffered illiteracy. We firstly rectified a drug information leaflet of antihypertensive medications for the general public distributed by the Korean authority based on focus group interviews (9 participants). The revised leaflets were tested four times with 8~12 participants in each round (40 seniors in total). We targeted to develop a leaflet which more than 80% of participants understood 10 key information. Main outcomes measures were to be able to find information and be able to understand information. This study was approved by the Yeungnam University Research Ethics Committee. Results: Focus group interviews identified difficulties with small font of words, professional language, long information, and a poor structure. The leaflet was revised and in the first round questionnaire found problems with 4/10 information points; interviews disclosed all but one (normal blood pressure range) were ill-understood. The second round questionnaire and interview found fewer problems but the comprehensiveness of participants was still poor in several points. For the third and fourth rounds we revised the leaflets in the individual-targeted manner. Finally, the fourth round showed all key information found and understood by at least 80% of participants except one question about drug name. Conclusion: The drug leaflets need to be developed in a personalized mode for the seniors. There was a limit for Korean seniors to understand nonproprietary name of their drugs because they used to producers' trade names which the Korean health system predominantly works with.

E-Isolation : High-performance Dynamic Testing Installation for Seismic Isolation Bearings and Damping Devices

  • Yoshikazu Takahashi;Toru Takeuchi;Shoichi Kishiki;Yozo Shinozaki;Masako Yoneda;Koichi Kajiwara;Akira Wada
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.1
    • /
    • pp.93-105
    • /
    • 2023
  • Seismic isolation and vibration control techniques have been developed and put into practical use by challenging researchers and engineers worldwide since the latter half of the 20th century, and after more than 40 years, they are now used in thousands of buildings, private residences, highways in many seismic areas in the world. Seismic isolation and vibration control structures can keep the structures undamaged even in a major earthquake and realize continuous occupancy. This performance has come to be recognized not only by engineers but also by ordinary people, becoming indispensable for the formation of a resilient society. However, the dynamic characteristics of seismically isolated bearings, the key elements, are highly dependent on the size effect and rate-of-loading, especially under extreme loading conditions. Therefore, confirming the actual properties and performance of these bearings with full-scale specimens under prescribed dynamic loading protocols is essential. The number of testing facilities with such capacity is still limited and even though the existing labs in the US, China, Taiwan, Italy, etc. are conducting these tests, their dynamic loading test setups are subjected to friction generated by the large vertical loads and inertial force of the heavy table which affect the accuracy of measured forces. To solve this problem, the authors have proposed a direct reaction force measuring system that can eliminate the effects of friction and inertia forces, and a seismic isolation testing facility with the proposed system (E-isolation) will be completed on March 2023 in Japan. This test facility is designed to conduct not only dynamic loading tests of seismic isolation bearings and dampers but also to perform hybrid simulations of seismically isolated structures. In this paper, design details and the realization of this system into an actual dynamic testing facility are presented and the outcomes are discussed.

A real-time hybrid testing based on restart-loading technology for viscous damper

  • Guoshan Xu;Lichang Zheng;Bin Wu;Zhuangzhuang Ji;Zhen Wang;Ge Yang
    • Smart Structures and Systems
    • /
    • v.32 no.6
    • /
    • pp.349-358
    • /
    • 2023
  • Real-Time Hybrid Testing (RTHT) requires the numerical substructure calculations to be completed within the defined integration time interval due to its real-time loading demands. For solving the problem, A Real-Time Hybrid Testing based on Restart-Loading Technology (RTHT-RLT) is proposed in this paper. In the proposed method, in case of the numerical substructure calculations cannot be completed within the defined integration time interval, the experimental substructure was returned back to the initial state statically. When the newest loading commands were calculated by the numerical substructure, the experimental substructure was restarted loading from the initial state to the newest loading commands so as to precisely disclosing the dynamic performance of the experimental substructure. Firstly, the methodology of the RTHT-RLT is proposed. Furthermore, the numerical simulations and experimental tests on one frame structure with a viscous damper are conducted for evaluating the feasibility and effectiveness of the proposed RTHT-RLT. It is shown that the proposed RTHT-RLT innovatively renders the nonreal-time refined calculation of the numerical substructure feasible for the RTHT. The numerical and experimental results show that the proposed RTHT-RLT exhibits excellent performance in terms of stability and accuracy. The proposed RTHT-RLT may have broad application prospects for precisely investigating the dynamic behavior of large and complex engineering structures with specific experimental substructure where a restarting procedure does not affect the relevant hysteretic response.

Research about the Effect that Taekwondo Shoes have on the Performance and Friction during the Turing and Turning Back Kick (태권도 돌려차기와 몸돌려 후려차기시 태권도화 착용에 따른 기계적 마찰력과 태권도 수행력 연구)

  • Park, Seung-Bum;Lee, Jung-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.1
    • /
    • pp.117-127
    • /
    • 2008
  • The purpose of this study was to investigate the relationship between research of mechanical friction and Taekwondo kick performance. For this a Taekwondo kick performance test, A.F.T.S.(Automated Footwear Testing System) and survey about fitting was used. There was a statistically significant difference between all the Taekwondo shoe types. While performing the roundhouse kick there were statistically significant differences in the peak free moment(p=.01) and peak plantar pressure between type A and B. Comfort testing revealed that there were statistically significant difference between type A and B in the five comfort variables tested but not between type B and Type C. There was statistically significant differences between each of the Taekwondo shoes but there was no relationship between the performance and the results of the survey.

Performance Evaluation of SG Tube Defect Size Estimation System in the Absence of Defect Type Classification (결함 형태 분류 과정이 필요없는 SG 세관 결함 크기 추정 시스템의 성능 평가)

  • Jo, Nam-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.13-19
    • /
    • 2010
  • In this paper, we study a new estimation system for the prediction of steam generator tube defects. In the previous research works, defect size estimators were independently designed for each defect types in order to estimate the defect size. As a result, the structure of estimation system is rather complex and the estimation performance gets worse if the classification performance is degraded for some reason. This paper studies a new estimation system that does not require the classification of defect types. Although the previous works are expected to achieve much better estimation performance than the proposed system since it uses the estimator specialized in each defect, the performance difference is not so large. Therefore, it is expected that the proposed estimator can be effectively used for the case where the defect type classification is imperfect.