• Title/Summary/Keyword: Performance rate

Search Result 16,830, Processing Time 0.04 seconds

A Study on Measuring the Speaking Rate of Speaking Signal by Using Line Spectrum Pair Coefficients

  • Jang, Kyung-A;Bae, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.3E
    • /
    • pp.18-24
    • /
    • 2001
  • Speaking rate represents how many phonemes in speech signal have in limited time. It is various and changeable depending on the speakers and the characters of each phoneme. The preprocessing to remove the effect of variety of speaking rate is necessary before recognizing the speech in the present speech recognition systems. So if it is possible to estimate the speaking rate in advance, the performance of speech recognition can be higher. However, the conventional speech vocoder decides the transmission rate for analyzing the fixed period no regardless of the variety rate of phoneme but if the speaking rate can be estimated in advance, it is very important information of speech to use in speech coding part as well. It increases the quality of sound in vocoder as well as applies the variable transmission rate. In this paper, we propose the method for presenting the speaking rate as parameter in speech vocoder. To estimate the speaking rate, the variety of phoneme is estimated and the Line Spectrum Pairs is used to estimate it. As a result of comparing the speaking rate performance with the proposed algorithm and passivity method worked by eye, error between two methods is 5.38% about fast utterance and 1.78% about slow utterance and the accuracy between two methods is 98% about slow utterance and 94% about fast utterances in 30 dB SNR and 10 dB SNR respectively.

  • PDF

Investigation of Performance Characteristics in a Welded Plate Heat Exchanger according to Mass flow rate and Temperature (용접식 판형열교환기에서 작동유체의 유량과 온도변화에 따른 성능특성 고찰)

  • Ham, Jeonggyun;Kim, Min-Jun;An, Sungkook;Cho, Honghyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.20-26
    • /
    • 2018
  • In this study, the performance characteristics of a welded plate heat exchanger was investigated experimentally. Performance tests were carried out according to the flow rate and inlet temperature of working fluid. As a result, the heat transfer capacity increased by 335.5 kW with an increasing the flow rate and temperature difference between hot and cold side. However, the overall heat transfer coefficient was increased with the increase of flow rate, and it was not effected significantly from inlet temperature difference between hot and cold working fluid. The pressure drop was increased by 55.78 kPa with an increasing the frow rate when the flow rate ratio between hot and cold side 1:1. However, the tendency of pressure drop was difference when flow rate ratio wasn't 1:1. In case that the flow rate ratio between hot and cold side was not 1:1, the pressure drop at the low flow rate side was higher than that when the flow rate ratio was 1:1, while pressure drop of the other side was decreased compared to that when the flow rate ratio was 1:1.

Development of an Evaluation Method for the Flow Rate Performance of Gas Sampling Pumps Using Adsorbent Tubes (흡착튜브를 이용한 가스상물질 채취용 펌프의 유량성능 평가방법)

  • Kim, Nam Hee;Song, Ho June;Kim, Ki Youn;Ma, Hye Lan;Yi, Gwang Yong;Jeong, Jee Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.201-207
    • /
    • 2014
  • Objectives: Flow rate stability is very important for obtaining reliable measurements. However there is no easily used method for checking whether the flow rate set at the initial stage is sustained during sampling. The purpose of this study was to develop a method to evaluate the flow rate performance of gas sampling pumps with adsorbents commonly used to sample gases. Materials and methods: We tested the back pressure of gas sampling pumps commonly used in Korea with adsorbents such as charcoal and silica tubes and attempted to discover the combination conditions of adsorbents in accordance with back pressure required by ISO standard 13137. Results: We found the combination of sampling adsorbents to be applicable to the pressure drop required by the ISO standard for evaluating flow rate stability under increasing pressure drop and long term (eight-hour) performance. Conclusions: This evaluation method of using a sampling media matrix for checking flow rate stability as proposed by this study could be a highly useful tool for determining the reliability of the performance pumps before sampling.

Development of an Evaluation Method for Flow Rate Performance of Particulate Sampling Pump using Three-pieces Cassette Holder Containing Filters (여과지가 장착된 3단 카세트를 이용한 입자상물질 채취용 펌프의 유량성능 평가방법)

  • Song, Ho-June;Kim, Nam-Hee;Kim, Ki-Youn;Ma, Hye-Lan;Lee, Kwang-Young;Jeong, Jee-Yeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.4
    • /
    • pp.348-355
    • /
    • 2013
  • Objectives: In working environment measurement, sampling is an important stage for obtaining reliable result as analysis. A personal air sampling pump is one of the most fundamental and important element in the work environment measurement, but it remains at the level of calibrating the flow rate of the pump before and after sampling. There is no checking whether the flow rate set at the initial stage would be hold during sampling. The purpose of this study was to develop a method to evaluate the flow rate performance of particulate sampling pump with three-pieces cassette holder containing filters commonly used to sample particulate. Materials and methods: We tested back pressure of particulate sampling pumps commonly used in Korea with three-pieces cassette holder containing various filters, and tried to find out the combination conditions of filters in accordance with back pressure required by ISO standard 13137. Results: We found out the matrix of sampling media such as three-pieces cassette holder containing filters applicable to the pressure drop required by the ISO standard for evaluating the flow rate stability under increasing pressure drop and long term(8 hour) performance. Conclusions: This evaluation method using sampling media matrix for checking flow rate stability proposed by this study could be very useful tool to find out good performance pumps before sampling.

Power and Rate Adaptations in Multi-carrier DS/CDMA Communications over Rayleigh Fading Channel (레일레이 패이딩 채널에서 다중 반송자 DS/CDMA 통신 시스템의 전력-전송율 적응 방식)

  • Ah Heejune;Lee Ye Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.6C
    • /
    • pp.423-433
    • /
    • 2005
  • We present power(in frequency domain) and rate adaptation(in time domain) schemes in multicarrier (MC) direct-sequence code-division multiple-access(DS/CDMA) communications. Utilizing channel state information from the receiver, the adaptation schemes allocate power the user's sub-band with the largest channel gain. In the time domain, the transmission data rate is adapted for a desired transmission quality. In the case of single-user channels, a closed-form expression is derived for an optimal time domain power adaptation that minimizes the average bit error rate(BER). Channel inversion power adaptation is found to provide nearly optimal performance in this case, as the number of sub-bands or available average transmission power increase. Analysis and simulation results show the BER performance of the proposed power and rate adaptations with fixed average transmission power significantly improves the performance over the power allocation in the frequency domain only. Also, we compare the performance of the proposed power and rate adaptation schemes in MC-DS/CDMA systems with that of power and rate adapted single carrier DS/CDMA systems with RAKE receiver.

An Experimental Study on Engine Performance of LPG/Gasoline Bi-Fuel (LPG/가솔린 Bi-Fuel 엔진성능에 관한 실험적 고찰)

  • Jun, Bong-Jun;Park, Myung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1433-1438
    • /
    • 2009
  • The purpose of this study is to investigate how the ignition spark timing conversion influences the engine performance of LPG/Gasoline Bi-Fuel engine. We propose the control system which can advance the ignition spark timing in LPG fuel mode more than used in gasoline fuel mode. In order to investigate the engine performance during combustion, engine performance are sampled by data acquisition system, for example cylinder pressure, pressure rise rate and heat release rate, while change of the rpm(1500, 2000) and the ignition timing advance($5^{\circ}$,$10^{\circ}$,$15^{\circ}$,$20^{\circ}$) As the result, between 1500rpm and 2000rpm, the cylinder pressure and pressure rise rate was increased when the spark ignition was advanced but pressure rise rate at $20^{\circ}$was smaller value. Also, the heat release rate at 1500rpm was increased but it was lower around $20^{\circ}$at 2000rpm.

Performance of Adaptive array antenna system under the Multi-Rate Service Environment (Multi Rate Service 환경 하에서의 adaptive array antenna system의 성능 분석)

  • 박현화;김정호
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.396-402
    • /
    • 2003
  • 본 논문에서는 multi-media service를 제공하는데 smart antenna system을 적용했을 때의 performance 를 각 서비스별 특성에 따라 평가한다. 서로 다른 다중 rate 의 신호가 각각의 안테나를 통해서 수신되는 환경 하에서 adaptive smart antenna를 적용함으로써 보다 고속이고 향상된 용량의 서비스를 제공할 수 있도록 하기 위해서는 사용자의 지리적 분포 또는 간섭 전력에 따라서 성능 특성이 달라지므로 이에 대한 성능 분석을 시뮬레이션을 통해서 수행한다.

  • PDF

Performance degradation due to compressor fouling of an industrial gas turbine operating at design point condition (막오염에 의한 압축기 성능 저하가 발전용 가스터빈 설계점 성능에 미치는 영향에 관한 연구)

  • Seo, J.S.;Sohn, J.L.;Kim, J.H.;Kim, T.S.;Ro, S.T.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.3 s.20
    • /
    • pp.36-43
    • /
    • 2003
  • Operating performance of industrial gas turbines in combined cycle power plants depends upon atmospheric conditions. Compressor fouling caused by airborne particles in the atmosphere and their adhesions on compressor blades is one of critical phenomena related to the performance degradation of industrial gas turbines. Compressor fouling provokes increase of pressure loss in inlet duct, decrease of mass flow rate of intake air and decrease of compressor stage efficiency. In this study, impacts of compressor fouling on the performance of an industrial gas turbine operating at design point condition are investigated analytically. As results, it is found that the reduction of produced power with decreased mass flow rate of intake air caused by narrowed flow area by the adhesion of airborne particles on compressor blades is the most dominant impact on the gas turbine performance by the compressor fouling phenomena.

Experimental Study on the Cold Storage of Spherical Capsules in the Cylindrical Tank (원통형 축냉조내 구형캡슐들의 축냉에 관한 실험 연구)

  • ;;Jung, Gab Yong
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.10
    • /
    • pp.2647-2656
    • /
    • 1995
  • The present work was performed to axially and radially investigate the local cold storage performance in the cylindrical tank with the spherical capsules inserted n-Tetradecane as a new cold storage material. The local cold storage performance of the capsules in the tank was experimentally investigated for the inlet temperature of -7, -5, -3, 0.deg. C, for the flow rate of 0.95, 1.89, 2.84, 6.00 l/min, and for the diameter ratio of 4.9, 9.0, 13.1. The local cold storage performance in the case of using water applied for the commercial ice-ball system was axially investigated by changing the flow rate only with the inlet temperature of -7.deg. C and the diameter ratio of 9.0 in order to compare with the performance in the case of using n-Tetradecane. For the case of using n-Tetradecane, the difference of cold storage period between the first and the seventh story was increased as the inlet temperature was increased and the flow rate was decreased. The capsules at the center of the tank showed the supercooling and the increased cold storage period compared with the capsules at the wall of the tank due to the small porosity and insufficient cold storage performance at the center of the tank as the diameter ratio is increased. The case using water showed worse cold storage performance due to comparatively large supercooling than the case using n-Tetradecane.

Wetland Performance for Wastewater Treatment in Growing and Winter Seasons (생장기와 동절기의 인공습지 오수처리 성능)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.4
    • /
    • pp.37-46
    • /
    • 1999
  • Field experimnet of constructed wetland for rural wastewater treatment was performed from July 1998 to April 1999 including winter to examine the seasonal effect on the wetland performance. The system worked without freezing even under $-10^{\circ}C$ of air temperature as long as watewater was flowing. BOD removal rates varied in similar pattern as the air temperature, and winter performance was relatively lower than that in the growing season. However, removing performance during winter was still significant, and BOD removal rates were almost the the same as in the growing season. SS removal rate was relativelyless affected by temmperature, but lower decay rate during the winter can result in accumulation of the SS in the system, which releases constituents in the next spring and can affect whole system performance. The winter removal rates of nutrients like T-N and T-P were decreased about half compared to the growing season and low temperature. To maintain stabilized wetland performanced including winter time, supplying minimum heating for plants could be an alternative in field application. Experimental data was compared with NADB(North Americal Wetlands for Water Quality treatment database), and general performance of the system was within the reasonable range. The pollutant loading and effluent concentration of the experimented system were in high margin. Base on the experiment and databases, the required effluent water quality could be achieved if loading rate adjusted as ilulstrated in the database.

  • PDF