• Title/Summary/Keyword: Performance rate

Search Result 16,744, Processing Time 0.035 seconds

Effects of Cooling Flow Rate on Gas Foil Thrust Bearing Performance (냉각 유량이 가스 포일 스러스트 베어링의 성능에 미치는 영향)

  • Sung Ho Hwnag;Dae Yeon Kim;Tae Ho Kim
    • Tribology and Lubricants
    • /
    • v.39 no.2
    • /
    • pp.76-80
    • /
    • 2023
  • This paper describes an experimental investigation of the effect of cooling flow rate on gas foil thrust bearing (GFTB) performance. In a newly developed GFTB test rig, a non-contact type pneumatic cylinder provides static loads to the test GFTB and a high-speed motor rotates a thrust runner up to the maximum speed of 80 krpm. Force sensor, torque arm connected to another force sensor, and thermocouples measures the applied static load, drag torque, and bearing temperature, respectively, for cooling flow rates of 0, 25, and 50 LPM at static loads of 50, 100, and 150 N. The test GFTB with the outer radius of 31.5 mm has six top foils supported on bump foil structures. During the series of tests, the transient responses of the bearing drag torque and bearing temperature are recorded until the bearing temperature converges with time for each cooling flow rate and static load. The test data show that the converged temperature decreases with increasing cooling flow rate and increases with increasing static load. The drag torque and friction coefficient decrease with increasing cooling flow rate, which may be attributed to the decrease in viscosity and lubricant (air) temperature. These test results suggest that an increase in cooling flow rate improves GFTB performance.

Relationship between Normal Measurement and Error Rate of Output Voltage Linear Ratio of Seismic Accelerometer in Use (사용 중 지진 가속도계의 정상 측정과 출력전압 선형비 오차율 관계 분석)

  • Min-Jun Kim;Seong-Cheol Cho;Yong-Hun Jung;Jeong-Hun Won
    • Journal of the Korean Society of Safety
    • /
    • v.39 no.2
    • /
    • pp.65-74
    • /
    • 2024
  • We analyzed the relationship between the normal measurement of the seismic accelerometer (SA) and the error rate of the output voltage linear ratio to propose an evaluation method to determine whether the SA in use is measuring normally. Utilizing a test bed, the regular operation of SA in use was evaluated using acceleration data measured through impact tests since there are no regulations regarding performance testing of SA in use. For the used SA, the error rate of the output voltage linear ratio, which is a major performance criterion, was evaluated. We analyzed common characteristics of the SA that satisfied the impact test and the performance criteria of the output voltage linear ratio error rate. The results indicated that we must consider the decreasing trend and convergence of the error rate as the measurement angle increases, ensuring that the average value of the output voltage linear ratio error rate is within 1%.

A Study on the Engine Performance and Combustion Characteristics of Fish Oil in a Diesel Engine (디젤기관에서의 어유의 연소특성과 기관성능에 관한 연구)

  • 서정주;왕우경;안수길
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.3
    • /
    • pp.85-93
    • /
    • 1994
  • The engine performance and combustion characteristics of diesel oil and fish oil blended with diesel oils were investigated at various blending rate of fish oil in a diesel engine. The maximum pressure showed no significant difference among test fuels at low load, but it was higher as the blending rate of fish oil increases at high load. Increasing the blending rate of fish oil, the rate of heat release and burned fraction were higher than those of diesel oil. The ignition delay became longer than that of diesel oil as the blending rate of fish oil increases, and its differences were larger at different loads. The combustion duration and density of smoke were shorter and lower as the blending rate of fish oil increases. The rate of fuel consumption showed no significant difference between diesel oil and fish blended with diesel oils.

  • PDF

Survey for the Recognition and Performance rate in the Hospital Pharmacists on the Safety Rules about Hazardous Drugs (병원 약사들의 위해약물 안전 수칙의 인지도 및 수행도에 대한 조사연구)

  • Seo, In-Young;Kim, Young-Joo;Lee, Byoung-Koo
    • Korean Journal of Clinical Pharmacy
    • /
    • v.21 no.2
    • /
    • pp.66-73
    • /
    • 2011
  • The objective of this study was to evaluate the recognition and performance rates about the safety rules on hazardous drugs among the selected pharmacists. The 160 pharmacists working in 4 general hospitals and in the other 4 institutions specialized in the oncology division were surveyed through mail. Among the 137 respondents to the survey (response rate 85.6%), 111 pharmacists (81%) had recognized the terms of 'hazardous drugs'. In categories of vaccines and hormones, the degrees of the recognition rate were much lower than the cytotoxic medications. It was surveyed that the degree of recognition and performance of safety rules on injectable drugs were higher than the disposal and noninjectable medications. The higher recognition rate of the safety rules made the higher degree of performance. These results were expected to provide the incentive for guidelines on handling hazardous drugs based on Korean healthcare system.

A Study on Marketing Strategic Types and Performance in the Korea Apparel Firms

  • Chun Tae-Yoo
    • International Journal of Costume and Fashion
    • /
    • v.5 no.1
    • /
    • pp.75-89
    • /
    • 2005
  • The purpose of this study is to empirically ascertain how the fitness between marketing strategy each firm chooses and environment facing each firm affects the performance of firms measured by the growth rate of market share and the growth rate of profit/sales ratio. In doing so, firms are divided into three groups. With regard to the marketing strategy, firms are classified into three groups based on marketing strategy type; prospector, analyzer, and defender. The main result of this study are as follows: First, responding firms are classified into prospector, analyzer, and defender following Miles & Snow's marketing strategy types. This classification is made using a self typing method and further confirmed by a factor analysis using a number of variables relating marketing objectives and marketing mix. Second, the results show that there are significant differences across marketing strategies in the performance measures of the growth rate of market share and profit/sales ratio. It seems, however, that there is no straight forward relationship between the marketing strategy and the performance measures. This strongly implies that the type of marketing strategy to be adopted by each firm should depend on the environment facing each firm. Third, the result indicates that the growth rate of market share tends to depend only on the marketing strategy type regardless of sufficiency and variation of environment, but profit/sales ratio tends to depend on the fitness between marketing strategy type and environment. It implies that a firm should adopt different marketing strategies for different environment characteristics, in order to enhance the efficiency of resources used reflected in the profit/sales ratio.

Numerical Simulation of Ventilation Performance in a Dry Room (극저습 공조실의 환기성능에 대한 수치적 모사)

  • Choe, Seok-Ho;Lee, Gwan-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.594-603
    • /
    • 2002
  • The characteristics of moisture ventilation in a dry room were studied numerically The effect of three important parameters: position of outlets, aspect ratio($\beta$) of horizontal plane and air exchange rate(N), was analyzed by using the scales of ventilation efficiency. The ventilation performance was evaluated by varying the aspect ratio and air exchange rate in the four types of outlet position. It was shown that the ventilation performance was improved by decreasing the aspect ratio in the longitudinal arrangement of outlet. The highest ventilation performance was determined when $\beta$ was 4 in the transverse arrangement of outlet. Regardless of the aspect ratio, the ceiling arrangement of outlet played more dominant effect on the ventilation efficiency than the floor arrangement. In every type and aspect ratio, the increase of air exchange rate to improve ventilation performance was appropriate up to N=60 /h.

Performance Enhancement of SBC for Voice Signal Using Adaptive Postfiltering at the Medium Bit Rate (중간 전송율에서 적응 포스트 필터링을 이용한 음성용 SBC의 성능 향상)

  • 김원구;이남걸;윤대희;차일환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.2
    • /
    • pp.121-131
    • /
    • 1992
  • In this paper, three methods are studied to enhance the performance of SBC ( Sub-Band Coding )schemes for voice signal at the medium bit rate between 12 kbps and If; kbps, and adaptive postfilteritng using human auditory characteristics Is (Bone at the decoder out put. First, GQMF(Generalized Quadrature Mirror Filter ) Is used instead of QME'((Quadrature MirrorFiltcr ) to have better performance. Second, by adaptive bit allocation to each sub-band, speech quality is enhanced and valuable rate ceding If possible. Third, corriparlson study oS thr: coder performance using APCM(Adaptive Pulse Code ModulatioTi) and ADPCM( Adaptive Differentiai Pulse Code Modulatiori) , Indicates that SB AfCM performance better than the other. Adaptive postfiltering at the decoder output enhances the quality of the coded speech. The two proposed postfiltering methods decrease the noise sufficiently at the expense of the low computational load.

  • PDF

Performance and Flow Condition of Contra-rotating Small-sized Axial Fan at Partial Flow Rate

  • Shigemitsu, Toru;Fukutomi, Junichiro;Okabe, Yuki;Iuchi, Kazuhiro
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.271-278
    • /
    • 2010
  • Small-sized axial fans are used as air cooler for electric equipments. But there is a strong demand for higher power of fans according to the increase of quantity of heat from electric devices. Therefore, higher rotational speed design is conducted, although, it causes the deterioration of efficiency and the increase of noise. Then the adoption of contrarotating rotors for the small-sized axial fan is proposed for the improvement of performance. In the present paper, the performance curves of the contra-rotating small-sized axial fan with 100mm diameter are shown and the velocity distributions at a partial flow rate at the inlet and the outlet of each front and rear rotor are clarified with experimental results. Furthermore, the flow conditions between front and rear rotors of the contra-rotating small-sized axial fan are investigated by numerical analysis results and causes of the performance deterioration of the contra-rotating small-sized axial fan at the partial flow rate is discussed.

A Study on Engine Performance of the Ignition Spark Timing Conversion for LPG/Gasoline Bi-fuel Vehicle (LPG / 가솔린 겸용차량의 점화시기 변환에 의한 엔진성능고찰)

  • Chun, Bongjun;Park, Myungho
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.39-47
    • /
    • 2011
  • In a bi-fuel engine using gasoline and LPG fuel, with the current ignition timing for gasoline being used, the optimum performance could not be taken in LPG fuel supply mode. The ignition timing in LPG fuel mode must be advanced much more than that of gasoline mode for the compensation of its higher ignition temperature. The purpose of this study is to investigate how the ignition spark timing conversion influences the engine performance of LPG/Gasoline Bi-Fuel engine. In order to investigate the engine performance during combustion, engine performance are sampled by data acquisition system, for example cylinder pressure, pressure rise rate and heat release rate, while change of the rpm(1500, 2000, 2500) and the ignition timing advance($5^{\circ}$, $10^{\circ}$, $15^{\circ}$, $20^{\circ}$). As the result, between 1500rpm, 2000rpm and 2500rpm, the cylinder pressure and pressure rise rate was increased when the spark ignition was advanced but pressure rise rate at $20^{\circ}$ was smaller value.

Web-Based On-Line Thermal Performance Analysis System for Turbine Cycle of Nuclear Power Plant (온라인 웹기반 원전 터빈 사이클 열성능 분석 시스템)

  • Choi KiSang;Choi KwangHee;Ji MoonHak;Hong SeungYeol;Kim SeongKun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.3 s.234
    • /
    • pp.409-416
    • /
    • 2005
  • We need to develop a on-line thermal performance analysis system for nuclear power plant to determine performance status and heat rate of turbine cycle. We have developed PERUPS(PERformance Upgrade System) to aid the effective performance analysis of turbine cycle. Procedures of performance calculation are improved using several adaptations from standard calculation algorithms based on PTC(Performance Test Code). Robustness in the on-line performance analysis is increased by verification & validation scheme for measured input data. The system also provides useful web interfaces for performance analysis such as graphic heat balance of turbine cycle and components, turbine expansion lines, automatic generation of analysis report. The system was successfully applied for YongGwang nuclear plant unit #3,4.