• Title/Summary/Keyword: Performance of protecting

검색결과 292건 처리시간 0.021초

Development and Cyclic Behavior of U-Shaped Steel Dampers with Perforated and Nonparallel Arm Configurations

  • Atasever, Kurtulus;Celik, Oguz C.;Yuksel, Ercan
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1741-1753
    • /
    • 2018
  • Metallic dampers are sacrificial devices (fuses) that dissipate significant energy during earthquakes while protecting other parts of structures from possible damage. In addition to numerous implementation opportunities of other base isolation systems, U-shaped dampers (UD) are one of the widely investigated and used devices in practice especially in Japan. The present study focuses on enhancing seismic performance of these types of dampers by changing their geometric properties. UDs with perforated (i.e. with holes) and/or nonparallel arms are developed for this purpose. For a better comparison, the criterion of equal material volume (or mass) has been utilized. Three dimensional finite element models of the new type of UDs are formed and investigated numerically under selected displacement histories. Based on the obtained hysteretic curves; dissipated energy intensities, effective stiffness ratios, reaction forces, effective damping ratios are evaluated in this parametric study. It is found that both damper types have merits in use of seismic applications and that the selection of the damper configuration is dependent on the design specific issues.

A Cost-Effective, Single-Phase Line-Interactive UPS System that Eliminates Inrush Current Phenomenon for Transformer-Coupled Loads

  • Bukhari, Syed Sabir Hussain;Atiq, Shahid;Lipo, Thomas A.;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.675-682
    • /
    • 2016
  • Sudden voltage drops and outages frequently disturb the operation of sensitive loads for domestic, commercial, and industrial use. In some cases, these events may even impair the functioning of relevant equipment. To maintain power under such conditions, a UPS system is usually installed. Once a disturbance happens at the grid side, the line-interactive UPS system takes over the load to prevent an interruption. But, due to magnetic saturation of the transformer, a significant inrush current may occur for the transformer-coupled loads during this transition. The generation of such transient currents may in turn decrease the line voltage and activates over-current protecting devices of the system. In this work, a cost-effective, line-interactive UPS system is proposed that eliminates the inrush current phenomenon associated with transformer-coupled loads. The strategy was implemented by connecting a standard current-regulated voltage source inverter (CRVSI) to the secondary winding of the load transformer. During any transient condition at the grid side, the load current is monitored and regulated to achieve either seamless compensation of the load current or complete transferal of load from grid to the inverter. Experimental results were obtained for a prototype under all possible operating conditions so as to validate the performance of the proposed topology.

전기자동차용 배터리 관리 시스템에 관한 연구 (A Study on developing the Battery Management System for Electric Vehicle)

  • 한아군;박재현;추연규
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 추계학술대회
    • /
    • pp.882-883
    • /
    • 2013
  • With the development of the society, pure electric vehicles will be surely important of the future. Electric vehicle requires various technology like motor driving, battery management, operational efficiencies and so on. Battery management is indeed the most important to enhance battery's performance and life. This paper has deeply discussed and studied on the lithium-polymer battery management system of pure electric vehicle. First of all we have analyzed the characteristic of the lithium-polymer batteries and the factors influenced on the state of charge. Then a logical SOC measuring method has been raised, which is the combination of open circuit voltage and Ah integration. The next we will introduce the design of battery management system, the battery management system performs many functions, such as inspecting the whole process, when it's running cell equalization protecting and diagnosing the battery, estimating the state of charge. The module design style including microcontroller, data aquisition module, charging control module and serial communication module. To arrive at conclusions, the battery management system which this paper has introduced is reliable and economical.

  • PDF

프로그램 공정계획을 위한 주기적 버퍼 설치에 관한 고찰 (A Study on Periodic Buffer Allocation for Program Master Schedule)

  • 구교진
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2001년도 학술대회지
    • /
    • pp.81-87
    • /
    • 2001
  • 동적 변화가 상존하는 건설환경에서, 보수·리모델링 프로그램의 관리자는 자원하의 복수 프로젝트를 조정·관리하는데 어려움을 겪게 된다. 프로그램에 내재하는 불확실성과 상호종속성으로 인해, 단위작업의 지연과 그로 인한 연쇄적인 공정계획의 동요는 프로그램 전체의 안정성과 관리가능성을 저해한다. 본 논문은 먼저 건설관리에 적용되었던 생산관리기법들이 프로그램관리에 적용될 수 있는가를 살펴본 후, 프로그램 내부의 자원유동의 흐름에 주기적으로 버퍼를 설치하는 공정 안정화 모델을 제안하고자 한다. 몬테-칼로 시뮬레이션에 의한 비교실험으로 제안된 버퍼 관리모델의 성능을 프로그램의 생산성, 유연성, 그리고 안정성의 관점에서 분석하였다.

  • PDF

해수전해설비의 화학세정 최적화 방안에 관한 연구 (A Study on Chemical Cleaning of Electrolytic Facilities with Sea Water)

  • 이한철;이창우;현성호
    • 한국안전학회지
    • /
    • 제14권4호
    • /
    • pp.114-119
    • /
    • 1999
  • When NaOCl was generated and put into sea-water cooling machine in order to overcome the biological hindrances against sea-water cooling machine, it was converted into metallic ion, particularly Ca and Mg, as a hydrate in sea-water and is to stick to electrolyte as a side reaction. This phenomena make the distance between the electrolytes narrow to decrease the flow rate, which induces the local vortex flow which erodes the pole plate. Moreover, this increases the resistance of the electrolyte as well as voltage to decrease the electrolytic efficiency, which has curtailed a chlorine yield and caused a pole plate cut. We are able to overcome these problems by chemical cleaning and intend to extend the life-time of electrolyte and to increase output of the sea-water electrolysis facilities by studying optimal policy regarding chemical cleaning of electrolytic cell. Cleaning time of electrolytic facilities is determined when both increase in electrolytic efficiency and decrease in pole-plate voltage are 10%. At this time as operating current of electrolytic facilities is high, operating time is diminished. Whereas, parameter of end point determination according to cleaning is Mg ionic concentration in solution. When we use Cleaner as a 7wt% HCl, cleaning time is about 80min proper. We are able to maintain pole plate performance by protecting against pole plate cut by means of electrolytic by-product, improve operating rate of facilities, and cut down on maintenance expenditure after acidic cleaning.

  • PDF

전기적 피로하중을 받는 압전 작동기의 손상 메커니즘 (Damage Mechanisms of a Piezoelectric Actuator under Electric Fatigue Loading)

  • 우성충;구남서
    • 대한기계학회논문집A
    • /
    • 제32권10호
    • /
    • pp.856-865
    • /
    • 2008
  • Damage mechanisms in bending piezoelectric actuators under electric fatigue loading are addressed in this work with the aid of an acoustic emission (AE) technique. Electric cyclic fatigue tests have been performed up to $10^7$ cycles on the fabricated bending piezoelectric actuators. An applied electric loading range is from -6 kV/cm to +6 kV/cm, which is below the coercive field strength of the PZT ceramic. To confirm the fatigue damage onset and its pathway, the source location and distributions of the AE behavior in terms of count rate and amplitude are analyzed over the fatigue range. It is concluded that electric cyclic loading leads to fatigue damages such as transgranular damages and intergranular cracking in the surface of the PZT ceramic layer, and intergranular cracking even develops into the PZ inner layer, thereby degrading the displacement performance. However, this fatigue damage and cracking do not cause the final failure of the bending piezoelectric actuator loaded up to $10^7$ cycles. Investigations of the AE behavior and the linear AE source location reveal that the onset time of the fatigue damage varies considerably depending on the existence of a glass-epoxy protecting layer.

Efficient secret sharing scheme with cheater identification based on QR code

  • Huang, Peng-Cheng;Chang, Chin-Chen;Li, Yung-Hui;Liu, Yanjun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권10호
    • /
    • pp.5144-5160
    • /
    • 2019
  • Secret sharing is an effective way of protecting secret messages. However, the traditional secret sharing schemes are considered meaningless due to malicious people attention which might raise risks. To overcome the weakness, this paper presents an effective secret sharing scheme with the functionality of cheater identification, based on meaningful QR code. The secret message will be split and concealed in the padding region of cover QR codes with the assistance of Latin square and it can be completely restored when all the involved participants cooperate. The concealing strategy exploits the characteristic of Reed-Solomon (RS) code to ensure the strong robustness of generated QR code pseudo-shares. The meaningful QR code pseudo-shares help to reduce the curious of unrelated persons. Some experiments were done to evaluate the performance of proposed scheme. The results showed that the proposed scheme is feasible, efficient and secure compared to the other existing schemes. It also achieves a higher secret payload and maintains stronger robustness.

분진의 인체내 유입을 차단하기 위한 송기 마스크의 개발 및 성능평가 (Development and Performance Evaluation of Air-Supplied Mask)

  • 김민철;김현태;이규원
    • 청정기술
    • /
    • 제4권1호
    • /
    • pp.60-67
    • /
    • 1998
  • 환경문제에 대한 사회적 관심이 높아지면서 작업환경의 개선에 대한 필요성이 증가하고 있으며, 특히 부유분진으로부터 작업자들을 보호하는 것은 중요하다. 현재 산업체에서 가장 많이 사용되고 있는 분진 제거 방법은 면체 마스크이다. 면체 마스크는 1회용이어서 비용이 많이 들고 그 편리성에 비해 인체에 유해한 입자에 대해서는 낮은 여과 효율을 가지고 있다. 본 연구에서는 기존 면체 마스크를 대체할 수 있는 새로운 형태의 흡 배기판을 가진 반면형 송기 마스크를 개발하였다. 마스크는 HEPA 휠터가 장착된 송풍기를 통과한 깨끗한 공기를 안면에 공급하게된다. 개발된 송기 마스크는 성능 테스트와 현장 테스트를 실시하였고, 매우 양호한 결과를 얻었다.

  • PDF

Special Protection and Control Scheme for Transmission Line Overloading Elimination Based on Hybrid Differential Evolution/Electromagnetism-Like Algorithm

  • Hadi, Mahmood Khalid;Othman, Mohammad Lutfi;Wahab, Noor Izzri Abd
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1729-1742
    • /
    • 2017
  • In designing System Protection Schemes (SPSs) in power systems, protecting transmission network against extreme undesired conditions becomes a significant challenge in mitigating the transmission line overloading. This paper presents an intelligent Special Protection and Control Scheme (SPCS) using of Differential Evolution with Adaptive Mutation (DEAM) approach to obtain the optimum generation rescheduling to solve the transmission line overloading problem in system contingency conditions. DEAM algorithm employs the attraction-repulsion idea that is applied in the electromagnetism-like algorithm to support the mutation process of the conventional Differential Evolution (DE) algorithm. Different N-1 contingency conditions under base and increase load demand are considered in this paper. Simulation results have been compared with those acquired from Genetic Algorithm (GA) application. Minimum severity index has been considered as the objective function. The final results show that the presented DEAM method offers better performance than GA in terms of faster convergence and less generation fuel cost. IEEE 30-bus test system has been used to prove the effectiveness and robustness of the proposed algorithm.

굽힘 압전 복합재료 작동기의 전기적 피로 거동 (Electric Fatigue Behavior of a Bending Piezoelectric Composite Actuator)

  • 우성충;구남서
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.362-367
    • /
    • 2008
  • In the present work, we address electric fatigue behavior in bending piezoelectric actuators using an acoustic emission technique. Electric cyclic fatigue tests have been performed up to ten million cycles on the fabricated specimens. To confirm the fatigue damage onset and its pathway, the source location and distributions of the AE behavior in terms of count rate are analyzed over the fatigue range. It is concluded that electric cyclic loading leads to fatigue damages such as transgranular damages and intergranular cracking in the surface of the PZT ceramic layer, and intergranular cracking even develops into the PZT inner layer, thereby degrading the displacement performance. The electric-induced fatigue behavior seems to show not a continuous process but a step-by-step process because of the brittleness of PZT ceramic. Nevertheless, this fatigue damage and cracking do not cause the final failure of the bending piezoelectric actuator loaded up to 107 cycles. Investigations of the AE behavior and the linear AE source location reveal that the onset time of the fatigue damage varies considerably depending on the existence of a glass-epoxy protecting layer.

  • PDF