• 제목/요약/키워드: Performance monitoring

검색결과 3,638건 처리시간 0.03초

A Study of Performance Monitoring and Diagnosis Method for Multivariable MPC Systems

  • Lee, Seung-Yong;Youm, Seung-Hun;Lee, Kwang-Soon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2612-2616
    • /
    • 2003
  • Method for performance monitoring and diagnosis of a MIMO control system has been studied aiming at application to model predictive control (MPC) for industrial processes. The performance monitoring part is designed on the basis of the traditional SPC/SQC method. To meet the underlying premise of Schwart chart observation that the observed variable should be univariate and independent, the process variables are decorrelated temporally as well as spatially before monitoring. The diagnosis part was designed to identify the root of performance degradation among the controller, process, and disturbance. For this, a method to estimate the model-error and disturbance signal has been devised. The proposed methods were evaluated through numerical examples.

  • PDF

전자메일 서버의 웹 기반 성능 모니터링 시스템 구현 (Implementation of Web-based Performance Monitoring System for E-Mail Server)

  • 이승섭;황민태
    • 한국정보통신학회논문지
    • /
    • 제17권9호
    • /
    • pp.2105-2112
    • /
    • 2013
  • 본 논문에서는 대용량 전자메일 서버의 성능 데이터를 수집해 그 분석 결과를 웹 기반으로 관리자에게 제공하는 모니터링 시스템을 구현하였다. 이를 위해 전자메일 서버의 성능 데이터 수집 항목을 도출하고, 각 항목별 측정 임계치를 설정하여 전자메일 서버의 성능을 객관적인 수치로 표현될 수 있도록 하였다. 전자메일 서버의 성능 데이터 수집은 SCOM 2007 서버 모니터링 도구를 이용하였으며, 성능 분석 파라미터 설정은 마이크로소프트사에서 제공하는 Exchange 서버 관리 팩과 SCOM 2007에서 제공하는 모니터링 규칙을 이용하였다. ASP.NET 프레임워크 기반의 C# 프로그래밍을 통해 웹 기반의 성능 모니터링 프로그램을 개발했으며, 성능 분석 결과는 관리자에게 웹 기반의 성능보고서, 장애 보고서 및 가용성 보고서 형태로 제공된다. 장애 요소를 사전에 효율적으로 감지할 수 있어 본 시스템 적용 전후 비교시 60% 이상 장애 건수를 줄일 수 있었으며, 장애 발생시에도 복구에 소요되는 시간을 획기적으로 단축할 수 있었다.

기계시각을 이용한 고단 직립식 산란계 케이지의 무선 감시시스템 개발 (Development of Wireless Monitoring System for Layers Rearing in Multi-tier Layers Battery by Machine Vision)

  • 임송수;장동일;이승주;소재광
    • Journal of Biosystems Engineering
    • /
    • 제32권3호
    • /
    • pp.173-178
    • /
    • 2007
  • This research was conducted to develop and analyze a wireless monitoring system for judging if sick or dead layers (SDL) exist in multi-tier layers battery (MLB) by machine vision, and to evaluate the performance between a wired monitoring system and it. This study used the AP (Access Point), the RS-285 to RS-232 converter, RS-232 to Ethernet converter, PICBASIC board and upgraded lump image processing method to change wired monitoring system into wireless monitoring system. The system was tested at a pilot farm and farm layer house. Results showed that monitoring judgement success rate at a pilot farm on normal cage (without SDL) was 82.3% and that on abnormal cage (with SDL) was 87.5%, respectively. And communication performance test results showed at farm layer house was $700{\sim}900$ kbps while equipments operated. There were dropped slightly than performance of wired monitoring system, however, the quantity was too small to make a significant difference of performance of the controling system developed for wireless communication.

Influence line- model correction approach for the assessment of engineering structures using novel monitoring techniques

  • Strauss, Alfred;Wendner, Roman;Frangopol, Dan M.;Bergmeister, Konrad
    • Smart Structures and Systems
    • /
    • 제9권1호
    • /
    • pp.1-20
    • /
    • 2012
  • In bridge engineering, maintenance strategies and thus budgetary demands are highly influenced by construction type and quality of design. Nowadays bridge owners and planners tend to include life-cycle cost analyses in their decision processes regarding the overall design trying to optimize structural reliability and durability within financial constraints. Smart permanent and short term monitoring can reduce the associated risk of new design concepts by observing the performance of structural components during prescribed time periods. The objectives of this paper are the discussion and analysis of influence line or influence field approaches in terms of (a) an efficient incorporation of monitoring information in the structural performance assessment, (b) an efficient characterization of performance indicators for the assessment of structures, (c) the ability of optimizing the positions of sensors of a monitoring system, and (d) the ability of checking the robustness of the monitoring systems applied to a structure. The proposed influence line- model correction approach has been applied to an integrative monitoring system that has been installed for the performance assessment of an existing three-span jointless bridge.

Structural performance monitoring of an urban footbridge

  • Xi, P.S.;Ye, X.W.;Jin, T.;Chen, B.
    • Structural Monitoring and Maintenance
    • /
    • 제5권1호
    • /
    • pp.129-150
    • /
    • 2018
  • This paper presents the structural performance monitoring of an urban footbridge located in Hangzhou, China. The structural health monitoring (SHM) system is designed and implemented for the footbridge to monitor the structural responses of the footbridge and to ensure the structural safety during the period of operation. The monitoring data of stress and displacement measured by the fiber Bragg grating (FBG)-based sensors installed at the critical locations are used to analyze and assess the operation performance of the footbridge. A linear regression method is applied to separate the temperature effect from the stress monitoring data measured by the FBG-based strain sensors. In addition, the static vertical displacement of the footbridge measured by the FBG-based hydrostatic level gauges are presented and compared with the dynamic displacement remotely measured by a machine vision-based measurement system. Based on the examination of the monitored stress and displacement data, the structural safety evaluation is executed in combination with the defined condition index.

센서기반 교량 유지관리 시스템 (Sensor Based Bridge Monitoring System)

  • 장정환;김완종;안호현;이세호;정태영
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.602-607
    • /
    • 2003
  • Sensors based bridge monitoring system (SBBMS) is designed to perform real-time monitoring and to store the performance history of in-service bridges. In general, visual inspections play a major role in maintenance of in-service bridges; however, they are not adequate to document the behavior of a bridge. Therefore, visual inspections and sensor based monitoring systems complement each other. Sensor based bridge monitoring systems consist of hardware and software systems. The hardware system contains the sensors and data-loggers to measure the behavior of a structure, the communicational equipment to transmit the measured data from the site to the monitoring center, and the computers to arrange and analyze the data. The software system controls data-loggers, arranges and analyzes the measured data, makes real-time display, stores the performance history.

  • PDF

APPLICATION OF MONITORING, DIAGNOSIS, AND PROGNOSIS IN THERMAL PERFORMANCE ANALYSIS FOR NUCLEAR POWER PLANTS

  • Kim, Hyeonmin;Na, Man Gyun;Heo, Gyunyoung
    • Nuclear Engineering and Technology
    • /
    • 제46권6호
    • /
    • pp.737-752
    • /
    • 2014
  • As condition-based maintenance (CBM) has risen as a new trend, there has been an active movement to apply information technology for effective implementation of CBM in power plants. This motivation is widespread in operations and maintenance, including monitoring, diagnosis, prognosis, and decision-making on asset management. Thermal efficiency analysis in nuclear power plants (NPPs) is a longstanding concern being updated with new methodologies in an advanced IT environment. It is also a prominent way to differentiate competitiveness in terms of operations and maintenance costs. Although thermal performance tests implemented using industrial codes and standards can provide officially trustworthy results, they are essentially resource-consuming and maybe even a hind-sighted technique rather than a foresighted one, considering their periodicity. Therefore, if more accurate performance monitoring can be achieved using advanced data analysis techniques, we can expect more optimized operations and maintenance. This paper proposes a framework and describes associated methodologies for in-situ thermal performance analysis, which differs from conventional performance monitoring. The methodologies are effective for monitoring, diagnosis, and prognosis in pursuit of CBM. Our enabling techniques cover the intelligent removal of random and systematic errors, deviation detection between a best condition and a currently measured condition, degradation diagnosis using a structured knowledge base, and prognosis for decision-making about maintenance tasks. We also discuss how our new methods can be incorporated with existing performance tests. We provide guidance and directions for developers and end-users interested in in-situ thermal performance management, particularly in NPPs with large steam turbines.

Performance Analysis of Adaptive Partition Cache Replacement using Various Monitoring Ratios for Non-volatile Memory Systems

  • Hwang, Sang-Ho;Kwak, Jong Wook
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권4호
    • /
    • pp.1-8
    • /
    • 2018
  • In this paper, we propose an adaptive partition cache replacement policy and evaluate the performance of our scheme using various monitoring ratios to help lifetime extension of non-volatile main memory systems without performance degradation. The proposal combines conventional LRU (Least Recently Used) replacement policy and Early Eviction Zone (E2Z), which considers a dirty bit as well as LRU bits to select a candidate block. In particular, this paper shows the performance of non-volatile memory using various monitoring ratios and determines optimized monitoring ratio and partition size of E2Z for reducing the number of writebacks using cache hit counter logic and hit predictor. In the experiment evaluation, we showed that 1:128 combination provided the best results of writebacks and runtime, in terms of performance and complexity trade-off relation, and our proposal yielded up to 42% reduction of writebacks, compared with others.

A Study on Performance Analysis of Articulated Robot System for Smart Factory Based on Monitoring Simulator

  • Kim, Hee Jin;Kim, Dong-ho;Jung, Kum-jun;Han, Sung-Hyun
    • 한국산업융합학회 논문집
    • /
    • 제23권6_1호
    • /
    • pp.889-896
    • /
    • 2020
  • We describe a new approach to the analyze the control performance of robotic manipulator based on the monitoring system. The structure of monitoring simulator is consist of seven modes such as control state mode, coordinate mode, input/output mode, program mode, parameters mode, and track mode. The applied control algorithme consists of an time varying feed-forward and feedback controller. The proposed scheme is simple in structure, fast in computation, and suitable for real-time implimemtation. Moreover, this scheme does not require any accurate dynamic modeling and values of parameters. Performance of the proposed monitoring system is illustrated by simulation and experiment for robot manipulator with six degrees of freedom.

LabView를 이용한 풍력발전 성능평가용 모니터링 시스템 개발 (The Development of the Monitoring System for Power performance using the Lab View)

  • 고석환;장문석;주영철;이윤섭
    • 한국태양에너지학회 논문집
    • /
    • 제29권6호
    • /
    • pp.69-74
    • /
    • 2009
  • Monitoring system is an absolutely-required system for assessing a performance and fatigue load of the wind turbine in an on-shore wind energy experimental research complex. It was implemented for the purpose of monitoring the wind information measured from a meteorological tower at the monitoring house, and of utilizing the measured data(fatigue data and electric analyzing data of wind turbine)for the performance assessment, by using the LabVIEW program. Then, by adding the performance assessment-related data acquired from the wind turbine during the performance assessment and the data recorder for synchronizing the data of meteorological tower, the system(BusDAQ) was implemented. Because it transmitted the data by converting the output 'RS-232' of data logger which measures the wind condition into CAN protocol, the data error rate was minimized. Also, This paper is introduced to make the best use of the developed monitoring system and to explain about construct of the system and detailed data communication of its system.