• Title/Summary/Keyword: Performance measurement index

Search Result 329, Processing Time 0.026 seconds

A Study on the Retrieval of River Turbidity Based on KOMPSAT-3/3A Images (KOMPSAT-3/3A 영상 기반 하천의 탁도 산출 연구)

  • Kim, Dahui;Won, You Jun;Han, Sangmyung;Han, Hyangsun
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_1
    • /
    • pp.1285-1300
    • /
    • 2022
  • Turbidity, the measure of the cloudiness of water, is used as an important index for water quality management. The turbidity can vary greatly in small river systems, which affects water quality in national rivers. Therefore, the generation of high-resolution spatial information on turbidity is very important. In this study, a turbidity retrieval model using the Korea Multi-Purpose Satellite-3 and -3A (KOMPSAT-3/3A) images was developed for high-resolution turbidity mapping of Han River system based on eXtreme Gradient Boosting (XGBoost) algorithm. To this end, the top of atmosphere (TOA) spectral reflectance was calculated from a total of 24 KOMPSAT-3/3A images and 150 Landsat-8 images. The Landsat-8 TOA spectral reflectance was cross-calibrated to the KOMPSAT-3/3A bands. The turbidity measured by the National Water Quality Monitoring Network was used as a reference dataset, and as input variables, the TOA spectral reflectance at the locations of in situ turbidity measurement, the spectral indices (the normalized difference vegetation index, normalized difference water index, and normalized difference turbidity index), and the Moderate Resolution Imaging Spectroradiometer (MODIS)-derived atmospheric products(the atmospheric optical thickness, water vapor, and ozone) were used. Furthermore, by analyzing the KOMPSAT-3/3A TOA spectral reflectance of different turbidities, a new spectral index, new normalized difference turbidity index (nNDTI), was proposed, and it was added as an input variable to the turbidity retrieval model. The XGBoost model showed excellent performance for the retrieval of turbidity with a root mean square error (RMSE) of 2.70 NTU and a normalized RMSE (NRMSE) of 14.70% compared to in situ turbidity, in which the nNDTI proposed in this study was used as the most important variable. The developed turbidity retrieval model was applied to the KOMPSAT-3/3A images to map high-resolution river turbidity, and it was possible to analyze the spatiotemporal variations of turbidity. Through this study, we could confirm that the KOMPSAT-3/3A images are very useful for retrieving high-resolution and accurate spatial information on the river turbidity.

Measurement of the Device Properties of Fixed Temperature Heat Detectors for the Fire Modeling (화재모델링을 위한 정온식 열감지기의 장치물성 측정)

  • Park, Hee-Won;Cho, Jae-Ho;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Kim, Sung-Chan;Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.37-43
    • /
    • 2014
  • The high predictive performance of fire detector models is essentially needed to assure the reliability of fire and evacuation modeling in the process of Performance-Based fire safety Design (PBD). The main objective of the present study is to measure input information in order to predictive the accurate activation time of fixed temperature heat detectors adopted in Fire Dynamics Simulator (FDS) as a representative fire model. To end this, Fire Detector Evaluator (FDE) which could be measured the device properties of detector was used, and the spot-type fixed temperature heat detectors of two thermistor types and one bimetal type were considered as research objectors. Activation temperature and Response Time Index (RTI) of detectors required for the fire modeling were measured, and then the RTI was measured for ceiling jet flow and vertical jet flow in consideration of the install location of detectors. The results of fire modeling using measured device properties were compared and validated with the experimental results of full-scale compartment fires. It was confirmed that, in result, the numerically predicted activation time of detector showed reasonable agreement with the measured activation time.

The Impact of Neurocognitive Rehabilitation Therapy on Upper Limb Functions and Activity of Daily Living of Patients with Stroke (신경인지재활치료가 뇌졸중 환자의 상지기능과 일상생활동작에 미치는 영향)

  • Kim, Sun Hee;Kim, Kwang kee;Jeong, Won Mee;Lee, Jeong Weon
    • 재활복지
    • /
    • v.17 no.4
    • /
    • pp.401-420
    • /
    • 2013
  • This study was performed to investigate the impact of the Neurocognitive Rehabilitation Therapy on the upper limb function recovery of patients with stroke and their abilities to perform daily activities and to provide basic data for a long-term treatment. A total of 30 patients with hemiplegia that occurred due to stroke were recruited as subjects of the present study, and 15 patients were randomly assigned to a Neurocognitive Rehabilitation Therapy group and a conventional treatment group, respectively. And, tests were performed over four weeks, five times a week, and 30 minutes a session. Manual Function Test(MFT), Fugl-Meyer Assessment Scale(FMA), and Korean-Modified Bathel Index(K-MBI) were used to measure the degree of the functional recovery before and after the experiment. According to the data of this study, in the upper limb function test, the Neurocognitive Rehabilitation Therapy group showed significant increase of the measurement values of MFT and FMA(p <.05), and when the difference between the two groups were compared, the upper limb function showed a statistically significant difference. In the daily activity performance test, only the Neurocognitive Rehabilitation Therapy group showed a significant improvement of K-MBI value(p <.05). Based on the results of the present study, it was demonstrated that the Neurocognitive Rehabilitation Therapy was effective in enhancing the upper limb functions and daily activity performance of patients with stroke.

Developing Measurement Items for the Service Quality of Clinical Trials based on the Brady & Cronin Model (Brady & Cronin의 모델에 기반한 임상시험 서비스 질 측정 문항 개발)

  • Go-Eun Lee;Sanghee Kim;Sue Kim;Sang Hui Chu;Jeong-Ho Seok;So Yoon Kim
    • The Journal of KAIRB
    • /
    • v.6 no.1
    • /
    • pp.17-31
    • /
    • 2024
  • Purpose: This study aims to develop preliminary items for measuring the perceived service quality of clinical trials among participants and to verify content validity. Methods: This study was designed as a methodological study. A conceptual framework was established based on Brady and Cronin's hierarchical model, and preliminary items were prepared through translation-back-translation, a review of existing instruments, and in-depth interviews with clinical trial participants and clinical research coordinators. The final items were completed through content validity testing by experts and a review of items by clinical trial participants for the prepared preliminary items. Results: Through this study, a set of 58 items across four domains (quality of interaction with researchers, the physical environment, performance procedures, and performance results) and 9 components (information·education·communication, trust, respect for participant preferences, securing facilities and space, accessibility, comfortability, informed consent, coordination of care, subjective understanding of clinical trials) on the service quality of clinical trials were completed. The scale content validity index of all preliminary items was 0.96, meeting the recommended standards. The individual-item content validity index also meets the recommended criteria for most items, excluding four items. Conclusion: This study holds significance in developing items to measure the quality of clinical trial execution from the perspective of participants. By verifying the reliability and validity of these items through subsequent research, it is expected that they can be utilized as a valuable instrument to devise strategies for improving the quality of clinical trials.

  • PDF

The Assessment Tools in Palliative Medicine (완화 의학에서의 평가도구)

  • Gwak, Jung-Im;Suh, Sang-Yeon
    • Journal of Hospice and Palliative Care
    • /
    • v.12 no.4
    • /
    • pp.177-193
    • /
    • 2009
  • The assessment of patient status in palliative medicine is essential for determining treatments and for clinical outcomes. The objective of assessment tools is to raise the quality of care for individual patients and their families. There are a number of tools available to assess pain, non-pain symptoms and quality of life. The tools are either uni-dimensional or multi-dimensional measures. Unfortunately, however, no single tool is recommended to be a superior to others in symptoms or quality of life assessment. Therefore, to select an appropriate assessment tool, one should consider the time frame and unique characteristics of tools depending on purpose and setting. The combination of prognostic index is highly recommended in prognostication, and web-based prognostic tools are available. Recently, a new objective prognostic score has been constructed through multicenter study in Korea. It does not include clinicalestimates of survival, but includes new objective prognostic factors, therefore, anyone can easily use it. For beginners in palliative medicine, relatively easy-to-use tools would be convenient. We recommend Eastern Cooperative Oncology Group performance status to assess functional status, numeric rating scale for pain assessment and the Korean version of brief pain inventory for initial pain assessment. Asking directly with numeric rating scale or the Korean version of MD Anderson Symptom Inventory would be desirable to assess various symptoms together. We think that European Organization Research and Treatment Quality of Life Questionnaire Core 15 for Palliative Care is good to assess the quality of life, while Objective Prognostic Score is convenient as prognostic index for beginners.

  • PDF

UV Absorbent-added Polymerization and its Application as Ophthalmological Material (자외선 흡수제를 첨가한 고분자 중합 및 안 의료용 소재로의 적용)

  • Sung, A-Young;Kim, Tae-Hun;Ye, Ki-Hun
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.1
    • /
    • pp.98-103
    • /
    • 2011
  • This study was done for the preparation of macromolecular material with UV-blocking features by adding the benzophenone group that is commonly used as a UV-absorbent and $TiO_2$ which is known to be a very stable material in chemical and physical aspects. Also, we compared the level of UV absorbency of the polymer produced from polymerization with previous materials and measured basic properties such as water content, refractive index and optical transmittance of produced contact lenses. The results of the measurement showed that the refractive index and water content of the contact lens with added UV-absorbent was 1.430~1.440 and 35.0~45.0% respectively, which was similar to that of previous contact lenses. Also, for optical transmittances of each wave length, contact lenses without the UV-absorbent was 89%, 88% and 89% respectively for UV-A, UV-B and visible light, indicating that the UV transmittance is very high though contrary with cases of contact lenses with added 2-hydroxy-4-methoxy-benzophenone and 2,4-dihydroxy-benzophenone which showed transmittances of 0% and 6% respectively for UV-A and UV-B showing a UV-blocking effect. Meanwhile, contact lenses with added $TiO_2$ showed transmittance of 6% and 51% respectively for UV-A and UV-B also showing a UV-blocking effect. The visible transmittance was 77~89% showing that it satisfies the visible transmittance required for ophthalmological materials.

Analysis of dental hygiene assessment data of recall patients (mainly 20s age)

  • Choi, Hye-Jung;Woo, Hee-Sun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.6
    • /
    • pp.131-137
    • /
    • 2022
  • As the age increases, the oral cavity, that is, the teeth and periodontium, also begin to age, and accordingly, a preparation process is required. The preparation process is an important period for oral health management to start continuously with oral health education consisting of knowledge, attitude, and behavior from the 20s. Therefore, to design a clinical dental hygiene course for patients who visited a dental clinic in Gyeonggi-do and received continuous care in an oral health care room after treatment, we tried to analyze the data of the dental hygiene assessment. As a dental hygiene assessment tool, based on personal information and general medical history, dental visit experience, bleeding on probing(BOP), bad breath measurement, phase contrast microscopy, and O'Leary index were performed. The number of subjects who had dental visits was 75.4% and those without experience were 24.6%, and as a result of the periodontal examination, generally bleeding was found in 76.3%. In preventive oral care, the stage of dental hygiene assessment in the 20s is an important first step. From this point on, it is an important time to be systematically habituated so that you can take responsibility for your own oral condition. Therefore, in this study, the results of dental hygiene assessment through oral examinations of subjects in their 20s are derived and presented as basic data for the development of dental hygiene performance competency of dental hygienists during the clinical dental hygiene process in oral health education and oral health management.

A study on the standard for determining airborne sound insulation performance of sound barrier panels (방음판의 음향투과손실 측정규격에 관한 연구)

  • Oh, Yang Ki
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.302-311
    • /
    • 2022
  • Sound barrier walls are one of the most effective alternatives for reducing environmental noise on roads and railways in the city center. The insertion loss of the sound barrier against road traffic noise is the sum of the sound transmission loss, sound absorption loss, and sound energy reduction due to the diffraction attenuation of the sound barrier. The sound transmission loss of the sound barrier is one of the important factors that determine the insertion loss of the sound barrier and is a basic indicator that determines the performance of the sound barrier. Nevertheless, there is not a separate standard in Korea for measuring the acoustic transmission loss of sound barrier panels. There are only a few conditions in KS F 4770 series that stipulates on the general material of sound barrier panels. This thesis examines the necessity of the acoustic transmission loss measurement and evaluation standards of sound barrier walls, and seeks a measurement method in a free sound field (anechoic chamber) sound receiving room considering the characteristics of sound barrier walls installed in external spaces, unlike indoor building materials. In addition, a single number evaluation method using a reference spectrum was proposed so that the sound insulation effect according to various installation places such as roadside or railroad side can be easily displayed.

Measurement of Electron Beam Output for the Prototype Compact Linac (콤팩트 전자 선형가속기 시작품의 출력측정에 관한 연구)

  • Kim, Sung-Woo;Kang, Sang Koo;Rhee, Dong Joo;Lim, Heuijin;Lee, Manwoo;Yi, Jungyu;Lee, Mujin;Yang, Kwangmo;Ro, Tae Ik;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.1-5
    • /
    • 2015
  • The C-band compact linear accelerator (linac) is being developed at Dongnam Institute of radiological & Medical Sciences (DIRAMS) for medical and industrial applications. This paper was focused on the output measurement of the electron beam generated from the prototype electron linac. The dose rate was measured in unit of cGy/min per unit pulse frequency according to the IAEA TRS-398 protocol. Exradin-A10 Markus type plane parallel chamber used for the measurement was calibrated in terms of dose to water at the reference depth in water. The beam quality index ($R_{50}$) was determined by the radiochromic film with a solid water phantom approximately due to low energy electrons. As a result, the determined electron beam output was $17.0cGy/(min{\cdot}Hz$. The results were used to monitor the accelerator performance during the development procedure.

Development of Management Guidelines and Procedure for Anthropometric Suitability Assessment: Control Room Design Factors in Nuclear Power Plants

  • Lee, Kyung-Sun;Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.29-43
    • /
    • 2015
  • Objective: The aim of this study is to develop management guidelines and a procedure for an anthropometric suitability assessment of the main control room (MCR) in nuclear power plants (NPPs). Background: The condition of the MCR should be suitable for the work crews in NPPs. The suitability of the MCR depends closely on the anthropometric dimensions and ergonomic factors of the users. In particular, the MCR workspace design in NPPs is important due to the close relationship with operating crews and their work failures. Many documents and criteria have recommended that anthropometry dimensions and their studies are one of the foremost processes of the MCR design in NPPs. If these factors are not properly considered, users can feel burdened about their work and the human errors that might occur. Method: The procedure for the anthropometric suitability assessment consists of 5 phases: 1) selection of the anthropometric suitability evaluation dimensions, 2) establishment of a measurement method according to the evaluation dimensions, 3) establishment of criteria for suitability evaluation dimensions, 4) establishment of rating scale and improvement methods according to the evaluation dimensions, and 5) assessment of the final grade for evaluation dimensions. The management guidelines for an anthropometric suitability assessment were completed using 10 factors: 1) director, 2) subject, 3) evaluation period, 4) measurement method and criteria, 5) selection of equipment, 6) measurement and evaluation, 7) suitability evaluation, 8) data sharing, 9) data storage, and 10) management according to the suitability grade. Results: We propose a set of 17 anthropometric dimensions for the size, cognition/perception action/behavior, and their relationships with human errors regarding the MCR design variables through a case study. The 17 selected dimensions are height, sitting height, eye height from floor, eye height above seat, arm length, functional reach, extended functional reach, radius reach, visual field, peripheral perception, hyperopia/myopia/astigmatism, color blindness, auditory acuity, finger dexterity, hand function, body angle, and manual muscle test. We proposed criteria on these 17 anthropometric dimensions for a suitability evaluation and suggested an improvement method according to the evaluation dimensions. Conclusion: The results of this study can improve the human performance of the crew in an MCR. These management guidelines and a procedure for an anthropometric suitability assessment will be able to prevent human errors due to inadequate anthropometric dimensions. Application: The proposed set of anthropometric dimensions can be integrated into a managerial index for the anthropometric suitability of the operating crews for more careful countermeasures to human errors in NPPs.