• Title/Summary/Keyword: Performance isolation

Search Result 1,070, Processing Time 0.026 seconds

A Study on the Design of the Directional Coupler using Three Layer Microstrip Substrate (세 층 마이크로스트립 유전체 기판을 이용한 방향성 결합기 설계에 관한 연구)

  • 천동완;김원기;박정훈;김상태;신철재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.4
    • /
    • pp.513-520
    • /
    • 2001
  • In this paper, the directional coupler using three layer microstrip substrate is proposed and the design method is notified. Modified re-entrant mode coupler is the proposed structure that one layer is added on upper plane of coupled transmission lines and the floating conductor is placed on added layer's upper planes. This structure has high coupling for the increase of odd mode capacitance and also has good performance in VSWR, isolation, phase difference because the difference of effective permittivity is small in each mode. We have designed the coupler from the calculation of impedance, effective permittivity, coupling coefficient using even, odd mode analysis method. From the simulation and measurement, proposed coupler has about 2 dB more tighter coupling than conventional coupler and also has good performance in VSWR, isolation, phase difference.

  • PDF

Design of UWB MIMO Antenna for On-Body Application (인체 부착형 UWB MIMO 안테나 설계)

  • Joo, Eunman;Kwon, Kyeol;Jeon, Jaesung;Kim, Sunwoo;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.137-148
    • /
    • 2014
  • In this paper, design of a UWB MIMO antenna for an on-body application is proposed and antenna performance with body effect and the impact on the human body are investigated. The proposed MIMO antenna is composed of UWB antenna above ground plane and an additional plunger shaped isolator located between the two monopole antennas to enhance the isolation characteristic. The simulation and measurement are performed to analyze the effect of the human body on antenna performance when the human body is located in the near field of the antenna. According to the measurement results, the measured SAR values for antennas 1 and 2 are 0.132 W/kg and 0.08 W/kg, respectively when 0.5 mW input power is delivered. These values satisfy the FCC guideline which ragulates that the 1-g average SAR should be lower than 1.6 W/kg.

A Study on Real Time Fault Diagnosis and Health Estimation of Turbojet Engine through Gas Path Analysis (가스경로해석을 통한 터보제트엔진의 실시간 고장 진단 및 건전성 추정에 관한 연구)

  • Han, Dong-Ju
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.4
    • /
    • pp.311-320
    • /
    • 2021
  • A study is performed for the real time fault diagnosis during operation and health estimation relating to performance deterioration in a turbojet engine used for an unmanned air vehicle. For this study the real time dynamic model is derived from the transient thermodynamic gas path analysis. For real fault conditions which are manipulated for the simulation, the detection techniques are applied such as Kalman filter and probabilistic decision-making approach based on statistical hypothesis test. Thereby the effectiveness is verified by showing good fault detection and isolation performances. For the health estimation with measurement parameters, it shows using an assumed performance degradation that the method by adaptive Kalman filter is feasible in practice for a condition based diagnosis and maintenance.

Extending the OPRCB Seismic isolation system's governing equations of motion to 3D state and its application in multi-story buildings

  • M. Hosseini;S. Azhari;R. Shafie Panah
    • Earthquakes and Structures
    • /
    • v.24 no.3
    • /
    • pp.217-235
    • /
    • 2023
  • Orthogonal pairs of rollers on concave beds (OPRCB) are a low-cost, low-tech rolling-based isolating system, whose high efficiency has been shown in a previous study. However, seismic performance of OPRCB isolators has only been studied in the two-dimensional (2D) state so far. This is while their performance in the three-dimensional (3D) state differs from that of the 2D state, mainly since the vertical accelerations due to rollers' motion in their beds, simultaneously in two orthogonal horizontal directions, are added up and resulting in bigger vertical inertia forces and higher rolling resistance. In this study, first, Lagrange equations were used to derive the governing equations of motion of the OPRCB-isolated buildings in 3D. Then, some regular shear-type OPRCB-isolated buildings were considered subjected to three-component excitations of far- and near-source earthquakes, and their responses were compared to those of their fixed-base counterparts. Finally, the effects of more realistic modeling and analysis were examined by comparing the responses of isolated buildings in 2D and 3D states. Response histories were obtained by the fourth-order Runge-Kutta-Nystrom method, considering the geometrical nonlinearity of isolators. Results reveal that utilizing the OPRCB isolators effectively reduces the acceleration response, however, depending on the system specifications and earthquake characteristics, the maximum responses of isolated buildings in the 3D state can be up to 40% higher than those in the 2D state.

Effect of nonlinear soil-structure interaction on the seismic performance of 3D isolated transformers when scaling the response spectra using the improved wavelet method

  • Mohammad Mahmoudi;Abbas Ghasemi;Shahriar Tavousi Tafreshi
    • Structural Engineering and Mechanics
    • /
    • v.91 no.5
    • /
    • pp.469-486
    • /
    • 2024
  • Electric transformers are major components of electrical systems, and damage to them caused by earthquakes can result in significant financial loss. The current study modeled a three-dimensional (3D) isolated electrical transformer under horizontal and vertical records from different earthquakes. Instead of using fixed coefficients, an improved wavelet method has been used to create the greatest compatibility between the response spectra and the target spectrum. This method has primarily been used for dynamic analysis of isolated structures with spring-damper devices because it has shown greater accuracy in predicting the response of such structures. The effect of the nonlinear soil-structure interaction on the probability of transformer failure also has been investigated. Soil and structure interaction modeling was carried out using a beam on a nonlinear Winkler foundation. The effect of the nonlinear soil-structure interaction during dynamic analysis of transformers revealed that the greatest increase in the probability of transformer failure was in the fixed-base condition when the structure was located on soft soil. This intensified the response of the structure and increased the probability of transformer failure by up to 27% for far-field and up to 95% for near-field ground motions. A comparison of the results indicates that the use of 3D isolation systems in transformers in areas with soft clay that are subject to near-field ground motions can strongly reduce the probability of failure and improve the seismic performance of the transformer.

The Study on Development of Performance in Cryogenic Piston Pump (초저온 피스톤 펌프의 성능 향상에 관한 연구)

  • Lee, Jongmin;Lee, Jonggoo;Lee, Kwangju;Lee, Jongtai
    • Journal of Hydrogen and New Energy
    • /
    • v.25 no.3
    • /
    • pp.240-246
    • /
    • 2014
  • In order to develop a universal cryogenic piston pump of small size for increasing utilization of liquid hydrogen, dynamic compression performance of piston pump were evaluated and improvements were also discussed for piston rod and piston tip. The cryogenic piston pump has crosshead structure and inclined cup shape piston tip. As the results, it was found that i) insulation of heat flow from piston-rod part is required for stable operation ii) improving the self-clearance adjustment effect of piston tip and reducing piston eccentricity were desirable to promote pumping pressure and operating range.

Analysis of the Reduction of Light-weight Imapct Noise for Load Condition of Floating Floor (뜬바닥층의 하중조건에 따른 경량충격음 저감량 분석)

  • Kim, Myung-Jun;Lee, Sung-Ho;Yang, Jae-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.356-360
    • /
    • 2006
  • Recently, for the purpose of improving the isolation performance of impact noise, many resilient materials have been installed in a residential building. As one of the reduction method for improving the performance of light-weight impact noise, this study is focused on the load condition of floating layer over resilient material. We studied the correlation between the mass or load of the floating layer and the reduction of light-weight impact noise by experiments in reverberation chamber for testing the impact noise. The results show that the reduction of impact noise is improved by increasing the mass per unit area of floating layer until about $140kg/m^2$. But the reduction is not obvious by adding extra mass on the floating layer.

  • PDF

Further Evidence in Support of Psychotropic Action on Red Ginseng (인삼사포닌의 정신약리)

  • Hiroyuki Yoshimura;Kimura, Naoto
    • Journal of Ginseng Research
    • /
    • v.14 no.2
    • /
    • pp.171-177
    • /
    • 1990
  • Using an ethopharmacological technique, we demonstrated that saponin fraction from red ginseng root possessed a potent psychotropic actions on either intermale or maternal aggression models. A series of experiments clearly indicated that one of psychoactive ingredient is ginsenoside Rbl. Although a drug-induced debilitation of motor performance remains a possible cause of the antiaggressive affect of the drug. ginsenoside Rbl did not alter the locomotor activity of the mice during agonistic confrontations. Thus. one can eliminate the possibility that the psychotropic effect of ginsenoside Rbl might be concealed by a drug-induced impairment of motor performance. More recently, we developed a nevi model for copulatory disorder and introduced into the behavioral analysis of drug action. Male mice which has been housed individually from weaning for 5 weeks failed to manifest copulatory behavior when they encountered with the sexually receptive females. Daily administration of crude ginseng saponin during isolation housing period prevented the development of copulatory disorder, whereas both ginsenoside Rbl and Rgl were ineffective. A further experiment may be needed to explore active ingredient of ginseng saponins.

  • PDF

Control Performance for Semi-active Mount Featuring Magneto-Rheological Fluid (반능동형 MR유체 마운트의 성능제어)

  • Kim, O.S.;Park, W.C.;Lee, H.C.
    • Journal of Power System Engineering
    • /
    • v.8 no.2
    • /
    • pp.53-58
    • /
    • 2004
  • In this paper, the semi active mount featuring Magneto rheological fluid(MR Fluid) is proposed. MR fluid is suspension of micro sized magnetizable particles in a fluid medium, and its apparent viscosity can be varied by the applied strength of magnetic field. When the controllable MR fluid is applied to mechanical devices, the devices provide simple, rapid response interfaces between electronic controls and mechanical systems. The MR fluid is applied in the conventional fluid mount for improving its performance of the mount's isolation effect. A appropriate size of the MR mount is designed and manufactured on the basis of Bingham model of MR fluid. In addition, the field dependent damping forces of MR mount are evaluated with respect to the input frequency variation.

  • PDF

Real-Time Model-Based Fault Diagnosis System for EHB System (EHB 시스템을 위한 실시간 모델 기반 고장 진단 시스템)

  • Han, Kwang-Jin;Huh, Kun-Soo;Hong, Dae-Gun;Kim, Joo-Gon;Kang, Hyung-Jin;Yoon, Pal-Joo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.4
    • /
    • pp.173-178
    • /
    • 2008
  • Electro-hydraulic brake system has many advantages. It provides improved braking performance and stability functions. It also removes complex mechanical parts for freedom of design, improves maintenance requirements and reduces unit weight. However, the EHB system should be dependable and have back-up redundancy in case of a failure. In this paper, the model-based fault diagnosis system is developed to monitor the brake status using the analytical redundancy method. The performance of the model-based fault diagnosis system is verified in real-time simulation. It demonstrates the effectiveness of the proposed system in various faulty cases.