• Title/Summary/Keyword: Performance isolation

Search Result 1,070, Processing Time 0.034 seconds

Fault Detection and Isolation Performance Analysis of Modified SPRT with respect to Inertial Sensor Errors

  • Kim, Jeong-Yong;Yang, Cheol-Kwan;Shim, Duk-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.32.3-32
    • /
    • 2002
  • We analyze the effect of main inertial sensor errors such as, misalignment, scale factor error and bias on the performance of modified sequential probability ratio test (SPRT) for sequential fault detection and isolation (FDI). The inertial sensor errors cause the modified SPRT method to give false alarm. We use a two-stage KF to obtain a modified parity vector with which the inertial sensor errors can be removed and thus modified SPRT method can be used regardless of inertial sensor errors.

  • PDF

Experiment of an ABS-type control strategy for semi-active friction isolation systems

  • Lu, Lyan-Ywan;Lin, Ging-Long;Lin, Chen-Yu
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.501-524
    • /
    • 2011
  • Recent studies have discovered that a conventional passive isolation system may suffer from an excessive isolator displacement when subjected to a near-fault earthquake that usually has a long-period velocity pulse waveform. Semi-active isolation using variable friction dampers (VFD), which requires a suitable control law, may provide a solution to this problem. To control the VFD in a semi-active isolation system more efficiently, this paper investigates experimentally the possible use of a control law whose control logic is similar to that of the anti-lock braking systems (ABS) widely used in the automobile industry. This ABS-type controller has the advantages of being simple and easily implemented, because it only requires the measurement of the isolation-layer velocity and does not require system modeling for gain design. Most importantly, it does not interfere with the isolation period, which usually decides the isolation efficiency. In order to verify its feasibility and effectiveness, the ABS-type controller was implemented on a variable-friction isolation system whose slip force is regulated by an embedded piezoelectric actuator, and a seismic simulation test was conducted for this isolation system. The experimental results demonstrate that, as compared to a passive isolation system with various levels of added damping, the semi-active isolation system using the ABS-type controller has the better overall performance when both the far-field and the near-fault earthquakes with different PGA levels are considered.

Vertical equipment isolation using piezoelectric inertial-type isolation system

  • Lu, Lyan-Ywan;Lin, Ging-Long;Chen, Yi-Siang;Hsiao, Kun-An
    • Smart Structures and Systems
    • /
    • v.26 no.2
    • /
    • pp.195-211
    • /
    • 2020
  • Among anti-seismic technologies, base isolation is a very effective means of mitigating damage to structural and nonstructural components, such as equipment. However, most seismic isolation systems are designed for mitigating only horizontal seismic responses because the realization of a vertical isolation system (VIS) is difficult. The difficulty is primarily due to conflicting isolation stiffness demands in the static and dynamic states for a VIS, which requires sufficient rigidity to support the self-weight of the isolated object in the static state, but sufficient flexibility to lengthen the isolation period and uncouple the ground motion in the dynamic state. To overcome this problem, a semi-active VIS, called the piezoelectric inertia-type vertical isolation system (PIVIS), is proposed in this study. PIVIS is composed of a piezoelectric friction damper (PFD) and a leverage mechanism with a counterweight. The counterweight provides an uplifting force in the static state and an extra inertial force in the dynamic state; therefore, the effective vertical stiffness of PIVIS is higher in the static state and lower in the dynamic state. The PFD provides a controllable friction force for PIVIS to further prevent its excessive displacement. For experimental verification, a shaking table test was conducted on a prototype PIVIS controlled by a simple controller. The experimental results well agree with the theoretical results. To further investigate the isolation performance of PIVIS, the seismic responses of PIVIS were simulated numerically by considering 14 vertical ground motions with different characteristics. The responses of PIVIS were compared with those of a traditional VIS and a passive system (PIVIS without control). The numerical results demonstrate that compared with the traditional and passive systems, PIVIS can effectively suppress isolation displacement in all kinds of earthquake with various peak ground accelerations and frequency content while maintaining its isolation efficiency. The proposed system is particularly effective for near-fault earthquakes with long-period components, for which it prevents resonant-like motion.

Isolation Effectiveness by Progressive Space Organization in Negative Pressured Isolation Unit (음압격리병실에 있어서 단계별 공간구성의 격리효과)

  • Kwon, Soonjung;Sung, Minki
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.4
    • /
    • pp.79-86
    • /
    • 2016
  • Purpose: The purpose of this study is to identify the effect of Progressive Space Organization (ante-rooms) in Negative Pressured Isolation Unit(NPIU) such as National and Regional Isolation Units in Korea in order to build basic data for the evidence based design of Airborne Infection Isolation Units which should prepare and respond effectively to the public health crisis due to the hazardous airborne infectious disease. Methods: 1) Gas(SF6) test and analysis on the 23 Korean Isolation Units under operation. 2) Assessment of the isolation level of the space components by checking the Gas concentration. 3) Analysis of the Isolation Effectiveness according to Space Organizational levels. Results: 1) The higher segregation level is, the lower Gas(SF6) concentration is. 2) Too many segregations(anterooms) of Isolation Unit are not efficient for the prevention of infectious bacillus spread. For example, 4 level of segregation has similar segregation effect to the 3 level of segregation. Implications: Many anterooms in front of the isolated patient bedroom will guarantee the safe environment against the danger of hazardous airborne nosocomial infection. On the other hand, too many segregations is inefficient, expensive, inconvenient, narrow(unflexible) and so on. This study can be used as basic data for further development of design guidelines of isolation units.

Evaluation of Vibration Reduction Performance of Operator Seat for Agricultural Tractors (트랙터 운전석의 진동 감쇠 성능 평가)

  • Shin, Chang-Seop;Kim, Kyeong-Uk
    • Journal of Biosystems Engineering
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • Six models of operator seat supplied to local tractor manufacturers were tested in the laboratory in accordance with ISO 5007 and 78/764/EEC. No models out of the six met the allowable damping and transmissibility performance criteria of both ISO 5007 and 78/764/EEC. From the ISO criterion standpoint, one model failed in damping performance and 4 models in isolation performance. From the 78/764/EEC criterion standpoint, 4 models failed in damping performance and 4 models in isolation performance. However none of them failed in all of the criteria, either. Each model met the one acceptance criterion but failed in another. This indicated that operator seat must be improved to meet the current ISO 5007 or 78/764/EEC and the exposure limit value that will be enforced in EU tractor market from 2014 by EU Directive 2002/44 EC.

Performance Test of C-shape Steel Base Isolation System (C형 강재 지진격리장치의 성능시험)

  • Jung, Dae-Yu;Shim, Chul-Hwan;Park, Hyung-Ghee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.25-35
    • /
    • 2009
  • This paper introduces the performance of a newly developed base isolation system made from the combination of a polyurethane disk - attached pot bearing and C-shape steel dampers. Ultimate compressive load tests, ultimate rotation tests, dynamic tests, and dynamic load repeat tests have been completed to determine dynamic characteristics and to verify performance characteristics. The experimental results are compared with the analytic results. It is determined that all requirements for bridge bearing in the specifications are satisfied, and that adequate energy dissipation has occurred. The EDC and effective stiffness estimated by tests are similar to the theoretical values.

A Study on the Active Vibration Isolator PID Auto-tuning Using PSO Algorithm (PSO알고리즘을 활용한 능동 제진 시스템 PID 오토 튜닝에 관한 연구)

  • An, Il Kyun;Huh, Heon;Kim, Hyo-Young;Kim, Kihyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.59-64
    • /
    • 2022
  • Vibration is one of the factors that degrades the performance of equipment and measurement equipment used in high-tech industries such as semiconductors and display. The vibration isolator is classified into passive type and active type. The passive vibration isolator has the weakness of insufficient vibration isolation performance in the low frequency band, so an active vibration control system that can overcome these problems is used recently. In this paper, PID controller is used to control the active vibration isolator. Methods for setting the gain of the PID controller include the Zeigler-Nichols method, the pole placement method. These methods have the disadvantage of requiring a lot of time or knowing the system model accurately. This paper proposes the gain auto tuning method of the active vibration isolator applied with the PSO algorithm, which is an optimization algorithm that is easy to implement and has stable convergence performance with low calculations. It is expected that it will be possible to improve vibration isolation performance and reduce the time required for gain tuning by applying the proposed PSO algorithm to the active vibration isolator.

Stability Evaluation of Phased Isolation Intra-Clarifier Ditch Process on Short-Term Hydraulic Shock Loading (단기 수리학적 충격부하시 침전지 내장형 상분리 산화구공정의 처리 안정성 평가)

  • Hong, Ki-Ho;Chang, Duk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.791-799
    • /
    • 2005
  • The phased isolation intra-clarifier ditch system used in this study is a simplified novel process enhancing simultaneous removal of biological nitrogen and phosphorus in municipal wastewater in terms of elimination of additional pre-anaerobic reactor, external clarifier, recycle of sludge, and nitrified effluent recirculation by employing intrachannel clarifier. Laboratory-scale phased isolation ditch system was used to assess the treatability on municipal wastewater. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31days, and cycle times of 2~8hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 70~84%, and 65~90%, respectively. The rainfall in Korea is generally concentrated in summer because of site-specific characteristics. Especially, the wet season has set in on June to August. In combined sewers, seasonal variations are primarily a function of the amount of stormwater that enters the system. In order to investigate the effect of hydraulic shock loading on system performance, the laboratory-scale system was operated at an HRT of 6hours (two times of influent flowrate) during two cycles (8hours). The system performance slightly decreased by increasing of influent flowrate and decreasing of system HRT. Nitrification efficiency and TN removal were slightly decreased by increasing of influent flowrate (decreasing of system HRT), whereas, the denitrification was not affected by hydraulic shock loading. However, the higher system performance could be achieved again after four cycles. Thus, the phased isolation technology for enhanced biological nutrient removal in medium- and small-scale wastewater treatment plants suffering fluctuation of influent quality and flowrate.

Microvibration Control of High Technology Facilities Subjected to Train-induced Excitation using Smart Base Isolation (열차진동하중을 받는 첨단시설물의 스마트 면진시스템을 이용한 미진동제어)

  • Kim, Hyun-Su;Kang, Joo-Won;Kim, Young-Sik
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.2
    • /
    • pp.99-108
    • /
    • 2012
  • Microvibration problem of high-technology facilities, such as semi-conductor plants and TFT-LCD plants, has been considered as important factors that affects the performance of products and thus it is regarded as important in facilities with high precision equipments. In this paper, various base isolation control systems are used to investigate their microvibration control performance. To this end, train-induced ground acceleration is used for time history analysis and three-story example building structure is employed. Microvibration control performance of passive and smart base isolation systems have been investigated in this study. Based on numerical simulation results, it has been verified that smart base isolation system can control microvibration of a high-technology facility subjected to train-induced excitation.

A Study on Base Isolation Performance and Phenomenological Model of E-Shape Steel Hysteretic Damper (E-Shape 강재이력댐퍼의 수치모델과 기초격리구조물의 지진응답)

  • Hwang, Inho;Ju, Minkwan;Sim, Jongsung;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.685-690
    • /
    • 2008
  • Recently, as large structures become lighter and more flexible, the necessity of structural control for reducing excessive displacement and acceleration due to seismic excitation is increased. As a means to minimize seismic damages, various base isolation systems are adopted or considered for adoption. In this study, a base isolation system using hysteretic damper is shown to effectively protect structures against earthquakes. A mechanical model is determined that can effectively portray the behavior of a typical E-shape device. Comparison with experimental results for a hysteretic damper indicates that the model is accurate over a wide range of operating conditions and adequate for analysis. The seismic performance of hysteretic dampers are studied and compared with the conventional systems as a base isolation system. A five-story building is modeled and the seismic performance of the systems subjected to three different earthquake is compared. The results show that the hysteretic damper system can provide superior protection than the other systems for a wide range of ground motions.