• Title/Summary/Keyword: Performance index(PI)

Search Result 66, Processing Time 0.029 seconds

Optimun number of Fuzzy Labeling and Control Performance for Fuzzy Control.

  • Kankubo, Kouichi;Murakami, Shuta
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1191-1194
    • /
    • 1993
  • We consider a fuzzy controller corresponding to PI controller. This controller is applied to a controlled object which is a first order lag system with dead time. An antecedent part is divided into 3, 5, and 7 parts ( membership function of triangle shape ), and a consequent part into 3, 5, and 7 parts ( membership function of singleton ). In each combination of an antecedent part and a consequent one. We compare control efficiency under the performance criteria such that the overshoot is kept 20% and the ITAE index is minimized.

  • PDF

Factors for Speech Signal Time Delay Estimation (음성 신호를 이용한 시간지연 추정에 미치는 영향들에 관한 연구)

  • Kwon, Byoung-Ho;Park, Young-Jin;Park, Youn-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.823-831
    • /
    • 2008
  • Since it needs the light computational load and small database, sound source localization method using time delay of arrival(TDOA method) is applied at many research fields such as a robot auditory system, teleconferencing and so on. Researches for time delay estimation, which is the most important thing of TDOA method, had been studied broadly. However studies about factors for time delay estimation are insufficient, especially in case of real environment application. In 1997, Brandstein and Silverman announced that performance of time delay estimation deteriorates as reverberant time of room increases. Even though reverberant time of room is same, performance of estimation is different as the specific part of signals. In order to know that reason, we studied and analyzed the factors for time delay estimation using speech signal and room impulse response. In result, we can know that performance of time delay estimation is changed by different R/D ratio and signal characteristics in spite of same reverberant time. Also, we define the performance index(PI) to show a similar tendency to R/D ratio, and propose the method to improve the performance of time delay estimation with PI.

Generalized Sub-optimum Decoding for Space-Time Trellis Codes in Quasistatic Flat Fading Channel (준정적 플랫 페이딩 채널에서 시공간 트렐리스 부호의 일반화된 부최적 복호법)

  • Kim Young Ju;Shin Sang Sup;Kang Hyun-Soo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.1 s.343
    • /
    • pp.89-94
    • /
    • 2006
  • We present a generalized version of principal ratio combining (PRC)[1], which is a near-optimum decoding scheme for space-time trellis codes in quasi-static flat fading environments. In [1], the performance penalty increases as the number of receive antennas increases. In the proposed scheme, receive antennas are divided into K groups, and the PRC decoding method is applied to each group. This shows a flexible tradeoff between performance and decoding complexity by choosing the appropriate K. Moreover, we also propose the performance index(PI) to easily predict the decoding performance among the possible different(receive antenna) configurations.

The Relationship Between the Pyknosis of Granulosa Cell and the Change of Steroid Concentration in Porcine Ovarian Follicles (돼지 난소내 과립세포의 염색질이상응축과 여포액내 스테로이드호르몬의 농도 변화와의 상관관계)

  • Lee, Chang-Joo;Yoon, Yong-Dal;Kim, Jong-Heup;Kim, Moon-Kyoo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.16 no.1
    • /
    • pp.35-40
    • /
    • 1989
  • In order to study the follicular atretic mechanism in mammalian ovary, the relationship between pyknotic index (PI) of granulosa cells and the steroid concentrations in the follicular fluid of atretic follicle was investigated. Follicles were isolated from porcine ovary according to their sizes and the reproductive phases. Steroid concentrations were quantified by high-performance liquid chromatography. As PI increased, the concentration of progesterone was significantly increased(p<0.05), whereas testosterone and estradiol showed no significant changes in their concentration. As follicular size was increased, PI of follicular GC in the luteal phase was increased significantly(p<0.05) and the molar ratio of progesterone to testosterone was increased in the follicles of follicular phase. It can be concluded that progesterone accumulated in the follicular fluid as atresia of the follicles was progressed, and that PI of granulosa cells could be used as one of convenient and pratical criteria for the identification of follicular atresia.

  • PDF

Analysis of Dynamic Model and Design of Optimized Fuzzy PID Controller for Constant Pressure Control (정압제어를 위한 동적모델 해석 및 최적 퍼지 PID 제어기설계)

  • Oh, Sung-Kwun;Cho, Se-Hee;Lee, Seung-Joo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.303-311
    • /
    • 2012
  • In this study, we introduce a dynamic process model as well as the design methodology of optimized fuzzy controller for its efficient application to vacuum production system to produce a semiconductor, solar module and display and so on. In a vacuum control field, PID control method is widely used from the viewpoint of simple structure and preferred performance. But, PID control method is very sensitive to the change of environment of control system as well as the change of control parameters. Therefore, it's difficult to get a preferred performance results from target system which has a complicated structure and lots of nonlinear factors. To solve such problem, we propose the design methodology of an optimized fuzzy PID controller through a following series of steps. First a dynamic characteristic of the target system is analyzed through a series of experiments. Second the process model is built up and its characteristic is compared with real process. Third, the optimized fuzzy PID controller is designed using genetic algorithms. Finally, the fuzzy controller is applied to target system and then its performance is compared with that of other conventional controllers(PID, PI, and Fuzzy PI controller). The performance of the proposed fuzzy controller is evaluated in terms of auto-tuned control parameters and output responses considered by ITAE index, overshoot, rise time and steady state time.

Development of Borough Road Pavement Condition Evaluation Criteria and Prediction Index (자치구 포장상태평가등급 기준 개선 및 포장상태 예측지수 개발)

  • Lee, Sang Yum;Jeon, Jin Ho
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.115-122
    • /
    • 2016
  • OBJECTIVES : This study develops an evaluation method, which is useful to inspect pavement condition of specific boroughs. This is because pavement condition is broadly divided into five grades via visual inspection, which does not consider the types of deteriorations, and is decided by an investigator having a subjective viewpoint. This visual inspection method is not a satisfactory method for accurate maintenance when various deteriorations occur. METHODS : The performance model considers several factors such as crack, rutting, and IRI. This method is also modified from borough SPI based on SPI (Seoul Pavement Index). Considering limited budget of borough, PI (prediction index) is suggested, which is related to the grade of pavement condition evaluation and type of materials. Practical correlation review is also conducted with statistical verification by using the Monte Carlo simulation. RESULTS : The results of the study show that modified criteria are reasonable. First, the comparison between the visual inspection result and the SPI result indicates that the R-square value is sufficiently high. Second, through the common section, each evaluation method could be compared, and the result shows considerable similarity, which increases when the range is modified. Finally, PI for predicting remaining life and the random number SPI have common parts, which means that each indicator would be adequate to be used as an evaluation method. CONCLUSIONS : Comparison and analysis results show that the developed evaluation method is reasonable for specific boroughs where financial support is inadequate for the evaluation process by using the newer equipment. Moreover, for more accurate evaluation method, previous visual inspection data should be utilized, and the database of inspection equipment have to be collected.

Maximization of Transmission System Loadability with Optimal FACTS Installation Strategy

  • Chang, Ya-Chin;Chang, Rung-Fang
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.991-1001
    • /
    • 2013
  • Instead of building new substations or transmission lines, proper installation of flexible AC transmission systems (FACTS) devices can make the transmission networks accommodate more power transfers with less expansion cost. In this paper, the problem to maximize power system loadability by optimally installing two types of FACTS devices, namely static var compensator (SVC) and thyristor controlled series compensator (TCSC), is formulated as a mixed discrete-continuous nonlinear optimization problem (MDCP). To reduce the complexity of the problem, the locations suitable for SVC and TCSC installations are first investigated with tangent vector technique and real power flow performance index (PI) sensitivity factor and, with the specified locations for SVC and TCSC installations, a set of schemes is formed. For each scheme with the specific locations for SVC and TCSC installations, the MDCP is reduced to a continuous nonlinear optimization problem and the computing efficiency can be largely improved. Finally, to cope with the technical and economic concerns simultaneously, the scheme with the biggest utilization index value is recommended. The IEEE-14 bus system and a practical power system are used to validate the proposed method.

Photochemical Index Analysis on Different Shading Level of Garden Plants (정원 식물의 차광 조건별 광화학적 생리지표 해석)

  • Kang, Hong Gyu;Kim, Tae Seong;Park, So Hyun;Kim, Tae Wan;Yoo, Sung Yung
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.4
    • /
    • pp.264-271
    • /
    • 2016
  • The objective of this study was to determine the growth and light utilization efficiency of garden plants in shade area through chlorophyll fluorescence reaction analysis. Ten garden plants was grown for 75 days under 50% and 80% shading conditions. Under shading, $ET2_O/RC$, the fluorescence parameter related to electron-transport in photosystem II, was effectively enhanced. However, the electron transport flux until PSI acceptors per reaction center ($RE1_O/RC$) was reduced. These changes in photochemical parameters evoked a decrease in performance index (PI) and driving force (DF) of electron transport flux. In addition, some photochemical parameters such as $F_V$, $FV/F_O$, $RE1_O/RC$, $ET2_O/RC$, $PI_{TOTAL\;ABS}$, and $DF_{TOTAL\;ABS}$ were found to be important for shade tolerance. Three species (Pachysandra terminalis Siebold & Zucc, Physostegia virginiana L., and Carex maculata Bott) were found to be shade tolerant. Based on these results, shading factor index (SFI) deduced from photochemical parameters is useful for evaluating of shading stress of garden plants.

Study on Following of Parmeter ${\alpha}$ of 2-DOF PID Controller Using Fuzzy Algorithm

  • Lee, Sang-Min;Cho, Yong-Sung;Park, Jong-Oh;Choo, Yeon-Gyu;Lim, Young-Do
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.307-311
    • /
    • 2003
  • 2-mass system is generally used as controller of the variable-speed to transfer electromotion power to mechanical load such as industrial robot, driving parts of electric vehicle, rolling machine system of steel plant and driving parts of elevator. In this case, PI controller is often used as a velocity controller because of simplicity of system. But PI control algorithm is not enough for obtaining the control characteristics required for this system. To solve this problem, 2-mass system based on the PID controller derives the optimum PID parameters by pole assignment and estimation of the ITAE performance index. In this case, the system have tenacious properties about disturbance, but it causes extreme overshoot and vibration because of rapidly output of controller in early transient response about desired value. And if speed control system is applied by 2-DOF parameter ${\alpha}$, a temporary value, we must induce most suitable parameter by complicate pole assignment and estimation of the ITAE performance index whenever ${\alpha}$ changes. In this paper, to solve this problem we suggest control algorithm to followed exactly value of ${\alpha}$ as 2-DOF parameter by using fuzzy algorithm . So, intelligence algorithm modeled by human knowledge, experience, teachability and judgment follow exact ${\alpha}$ value and it can compose the efficient 2-DOF PID controller to improve following performance, overshoot decrease.

  • PDF

Physical Charateristics of Elastomer Modified Asphalt (탄성체로 개질된 아스팔트의 물리적 특성)

  • Lee, S.J.;Lee, S.J.;Lee, J.K.
    • Elastomers and Composites
    • /
    • v.32 no.3
    • /
    • pp.166-172
    • /
    • 1997
  • The objective in this study was investigated temperature susceptibility and low temperature fracture of rubber modified asphalt. A chlorinated polyethylene elastomer, Tyrin CM0730, was added to 200/300 grade asphalt with 3.0 and 5.0wt% to improve campatibility. The elastomer modified asphalts were analyzed for temperature susceptibility relating to penetration index(PI) and penetration-viscosity number(PVN) as well as low temperature fracture relating to fracture energy $(G_{IC})$. These indices were obtained from the measurements of penetration, viscosity, failure load and modulus. The addition of small amounts of elastomer to the asphalt resulted in a significant increase of both the PI and PVN over an unmodified asphalt. Also, the fracture energy increased with the addition of elastomer to asphalt. These significant improvement at both the high and low temperature result in enhanced performance.

  • PDF