• Title/Summary/Keyword: Performance degree

Search Result 3,686, Processing Time 0.029 seconds

A Novel Multi-link Integrated Factor Algorithm Considering Node Trust Degree for Blockchain-based Communication

  • Li, Jiao;Liang, Gongqian;Liu, Tianshi
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.8
    • /
    • pp.3766-3788
    • /
    • 2017
  • A blockchain is an underlying technology and basic infrastructure of the Bitcoin system. At present, blockchains and their applications are developing rapidly. However, the basic research of blockchain technology is still in the early stages. The efficiency and reliability of blockchain communication is one of the research problems that urgently need to be studied and addressed. Existing algorithms may be less feasible for blockchain-based communication because they only consider a single communication factor (node communication capability or node trust degree) and only focus on a single communication performance parameter(communication time or communication reliability). In this paper, to shorten the validation time of blockchain transactions and improve the reliability of blockchain-based communication, we first establish a multi-link concurrent communication model based on trust degree, and then we propose a novel integrated factor communication tree algorithm (IFT). This algorithm comprehensively considers the node communication link number and the node trust degree and selects several nodes with powerful communication capacity and high trust as the communication sources to improve the concurrency and communication efficiency. Simulation results indicate that the IFT algorithm outperforms existing algorithms. A blockchain communication routing scheme based on the IFT algorithm can increase communication efficiency by ensuring communication reliability.

Use of UHPC slab for continuous composite steel-concrete girders

  • Sharif, Alfarabi M.;Assi, Nizar A.;Al-Osta, Mohammed A.
    • Steel and Composite Structures
    • /
    • v.34 no.3
    • /
    • pp.321-332
    • /
    • 2020
  • The loss of composite action at the hogging moment zone for a continuous composite girder reduces the girder stiffness and strength. This paper presents an experimental investigation of the use of an ultra-high performance concrete (UHPC) slab at the hogging moment zone and a normal concrete (NC) slab at the sagging moment zone. The testing was conducted to verify the level of loading at which composite action is maintained at the hogging moment zone. Four two-span continuous composite girders were tested. The thickness of the UHPC varied between a half and a full depth of slab. The degree of shear connection at the hogging moment zone varied between full and partial. The experimental results confirmed the effectiveness of the UHPC slab to enhance the girder stiffness and maintain the composite action at the hogging moment zone at a load level much higher than the upper service load limit. To a lesser degree enhanced performance was also noted for the smaller thickness of the UHPC slab and partial shear connection at the hogging moment zone. Plastic analysis was conducted to evaluate the ultimate capacity of the girder which yielded a conservative estimation. Finite element (FE) modeling evaluated the girder performance numerically and yielded satisfactory results. The results indicated that composite action at the hogging moment zone is maintained for the degree of shear connection taken as 50% of the full composite action and use of UHPC as half depth of slab thickness.

Performance Evaluation of Multi-Degree-of-Freedom Robotic Mixer using Discrete Element Mixing Simulations (이산요소법 교반 시뮬레이션을 이용한 다자유도 로봇 믹서 성능 평가)

  • Son, Kwon Joong
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.219-224
    • /
    • 2020
  • Industrial mixers to homogeneously blend particulate materials have been developed and widely used in various industries. However, most industrial mixers have at most two-degree-of-freedom for the operation, which limits the range of operation parameter selection for optimal blending. This paper proposes a multi-degree-of-freedom robotic mixer designed by converging a conventional drum blender and a robotic manipulator and evaluated its performance in a virtual operating environment. Discrete element simulations were conducted for mixing performance evaluation. The numerical results showed that the proposed mixer design exhibits a better mixing performance than conventional ones.

Differential Evolution Approach for Performance Enhancement of Field-Oriented PMSMs

  • Yun, Hong Min;Kim, Yong;Choi, Han Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2301-2309
    • /
    • 2018
  • In a field-oriented vector-controlled permanent magnet synchronous motor (PMSM) control system, the d-axis current control loop can offer a free degree of freedom which can be used to improve control performances. However, in the industry the desired d-axis current command is usually set as zero without using the free degree of freedom. This paper proposes a method to use the degree of freedom for control performance improvement. It is assumed that both the inner loop proportional-integral (PI) current controller and the q-axis outer loop PI speed controller are tuned by the well-known tuning rules. This paper gives an optimal d-axis reference current command generator such that some useful performance indexes are minimized and/or a tradeoff between conflicting performance criteria is made. This paper uses a differential evolution algorithm to autotune the parameter values of the optimal d-axis reference current command generator. This paper implements the proposed control system in real time on a Texas Instruments TMS320F28335 floating-point DSP. This paper also gives experimental results showing the practicality and feasibility of the proposed control system, along with simulation results.

Effect of cover depth and rebar diameter on shrinkage behavior of ultra-high-performance fiber-reinforced concrete slabs

  • Yoo, Doo-Yeol;Kwon, Ki-Yeon;Yang, Jun-Mo;Yoon, Young-Soo
    • Structural Engineering and Mechanics
    • /
    • v.61 no.6
    • /
    • pp.711-719
    • /
    • 2017
  • This study investigates the effects of reinforcing bar diameter and cover depth on the shrinkage behavior of restrained ultra-high-performance fiber-reinforced concrete (UHPFRC) slabs. For this, twelve large-sized UHPFRC slabs with three different rebar diameters ($d_b=9.5$, 15.9, and 22.2 mm) and four different cover depths (h=5, 10, 20, and 30 mm) were fabricated. In addition, a large-sized UHPFRC slab without steel rebar was fabricated for evaluating degree of restraint. Test results revealed that the uses of steel rebar with a large diameter, leading to a larger reinforcement ratio, and a low cover depth are unfavorable regarding the restrained shrinkage performance of UHPFRC slabs, since a larger rebar diameter and a lower cover depth result in a higher degree of restraint. The shrinkage strain near the exposed surface was high because of water evaporation. However, below a depth of 18 mm, the shrinkage strain was seldom influenced by the cover depth; this was because of the very dense microstructure of UHPFRC. Finally, owing to their superior tensile strength, all UHPFRC slabs with steel rebars tested in this study showed no shrinkage cracks until 30 days.

Study on Consumer Counselors' Work Performance, Satisfaction and Willingness to Sustain the Work (소비자상담사의 업무수행, 만족도 및 업무지속의사에 대한 연구)

  • Huh, Kyung-Ok
    • Korean Journal of Human Ecology
    • /
    • v.12 no.5
    • /
    • pp.669-685
    • /
    • 2003
  • This research examined the work performance by consumer counselors, evaluations of their counseling work, the level of their satisfaction, and willingness to sustain consumer counseling work among Consumer Agencies and also identified the variables influencing the evaluation scores on those. The results were summarized as follows. First, the evaluation scores on the work performance of consumer counseling were generally high and they turned out to be generally satisfied with their work. On the other hand, most counselors responded that they would continue their counseling work. Second, there were differences in evaluation scores about speed and specialized area of counseling among Consumer Agencies. Counselors who worked for the Korea Consumer Protection Board recorded high scores in those both criteria. There were differences in the willingness of counselors to continue their counseling work among Consumer Agencies, too. Third, the evaluation scores in six areas of counseling tasks were high when the degree of satisfaction of counselors were high or when agencies treated the counseling important. Fourth, when counselors earned more salaries and owned the experience of in-firm training and when the Consumer Agencies highly valued counseling as consumer tasks, the degree of satisfaction among counselors increased. Finally, when counselors were old, major in consumer science, and held regular work-schedule, they exhibited high degree of satisfaction in their counseling work and they showed greater willingness to sustain their counseling work.

  • PDF

Study on Performance Comparison for Solar Collectors with Single Evacuated Tube using Surface Treatment and Commercial Double Evacuated Tube (표면처리를 이용한 단일진공관과 기존 이중진공관 태양열집열기의 성능비교 연구)

  • Chun, Tae-Kyu;Yang, Young-Joon;Lee, Kyung-Hee;Ahn, Young-Chull
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.149-156
    • /
    • 2013
  • The performances of solar collectors with single and double evacuated tube were experimentally compared. The solar collector with single evacuated tube using surface treatment in this study consists of radiation fin, heat pipe, absorber plate, glass tube, cap and regulating valve, and so on. Surface treatment was conducted for heat pipe and absorber plate with black chrome plating and copper black coating. As the results, the performance of solar collector with single evacuated tube using surface treatment showed good results compared that of double evacuated tube. Absorber plate played a positive role in performance and showed increase of about 28%. Further performance depends on vacuum degree and vacuum degree has to be considered economical efficiency in solar collector.

A Study on Integrated Quality Evaluation Model of Information System (정보시스템 종합품질평가 모형 연구)

  • Seo, Jang-Hoon;Lee, Gi-Jun;Park, Myeong-Kyu
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.4
    • /
    • pp.151-166
    • /
    • 2006
  • One of The standard issue in riding on the wave of the information system(IS) is records of performance, grow unprecedently fast, and has highly uncertain future. Within the framework of IS Evaluation, The main purpose of this study is to suggest performance quality evaluation system as follows, The Integrated Quality Evaluation Model Design(IQEMD) of Information System helps corporations to improve productivity, customer service and corporate competitive power. To respond flexibly this trend, we have to realize that the information system has to keep the most effective optimal information network at the proper time. The existing evaluation method has been concentrated on the evaluation of a degree of the information system maturity focused on static viewpoints. The evaluation of potential factors to affect the future-oriented performance, that can analyze both unit business being able to apply an information system base was used efficiently well and what performance evaluation item was obtained actually, was insufficient relatively. In this paper, An integrated quality evaluation method will analyze a degree of information system maturity in dynamic evaluation viewpoints rather than in static evaluation viewpoints. finally we estimated the relative degree of importance of each determinant using the AHP methodology The validity of the proposed model was also partially proved using two different methods, holistic and historical approach.

Spalling Properties of High Performance Concrete Designed with the Various Types of Coarse Aggregate (굵은골재 종류 변화에 따른 고성능 콘크리트의 폭렬특성)

  • Heo, Young-Sun;Park, Yong-Kyu;Jin, Hu-Lin;Jee, Suk-Won;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.95-98
    • /
    • 2006
  • This study investigates spalling properties of high performance concrete, 60MPa clan, made with the various types of coarse aggregate and adding ratio of polypropylene(PP) fiber. As experimental parameters, totally sixteen specimens of ${\phi}100{\times}200mm$ in size are prepared: one specimen for control without fiber, ten specimens with different coarse aggregate types, along with 0.05, 0.1, 0.15 percent of PP fiber in each. 1 hour fire test is conducted and then spalling appearance, spalling degree and residual compressive strength are examined. In addition, sit specimens made with two types of coarse aggregate site, along with same adding ratio of fiber are supplementally done, and only spalling properties is examined. Test results showed that control concrete and most specimens containing 0.05% of PP fiber exhibited 4 to 3 level of spalling degree, resulting severe explosive spalling, except for the specimen using basalt aggregate(Bc) showing 2 to 3 level of that. Especially, the Bc specimen containing 0.1% of the fiber exhibited that residual compressive strength value was 32%, which is 10% higher than other specimens using limestone or granite. Spalling resistance performance was also effective as aggregate size increase.

  • PDF

A study on the Preference of Material quality and the Demand Performance of Clothing for Underwear Materials (내의 소재에 대한 재질선호 및 요구 성능에 대한 연구)

  • Park, Young-Hee
    • Fashion & Textile Research Journal
    • /
    • v.11 no.1
    • /
    • pp.147-155
    • /
    • 2009
  • This study has been made to examine the basic information, the preferences of material quality, and the demand performance of clothing for underwear materials between atopic patients and non-patients. The measurement tool was a questionnaire. For statistical analysis of data, crosstabs, ${\chi}^2$-test, t-test and ANOVA through SPSS for Windows(version 14.0) were used. The results obtained are as follows. The degree of the basic knowledge about clothing materials indicated that women was higher than men. The material decision method and the most considering part in case of selecting underwear products showed difference between men and women. The preference factors for underwear material quality were drawn with the five factors of sense of weight/pliability, lustering/see-through, tactility, and sense of cold and warmth. The preferred underwear material showed difference according to gender, existence and nonexistence of atopic determatitis, and degree of strength of skin itching caused by clothing materials. The demand performances of clothing in case of selecting underwear were drawn with the four factors of hygiene/practicality, skin protection, quality of materials, and aesthetic attribute. The demand performance of underwear showed difference according to gender, existence and nonexistence of atopic determatitis, degree of strength of skin itching caused by clothing materials.