• Title/Summary/Keyword: Performance Tests

Search Result 6,830, Processing Time 0.041 seconds

The Factors Affecting Attitudes Toward HSDPA Service and Intention to Use: A Cross-Cultural Comparison between Asia and Europe (대영향(对影响)HSDPA복무적태도화사용의도적인소적연구(服务的态度和使用意图的因素的研究): 재아주화구주지간적(在亚洲和欧洲之间的)-개과문화비교(个跨文化比较))

  • Jung, Hae-Sung;Shin, Jong-Kuk;Park, Min-Sook;Jung, Hong-Seob;Hooley, Graham;Lee, Nick;Kwak, Hyok-Jin;Kim, Sung-Hyun
    • Journal of Global Scholars of Marketing Science
    • /
    • v.19 no.4
    • /
    • pp.11-23
    • /
    • 2009
  • HSDPA (High-Speed Downlink Packet Access) is a 3.5-generation asynchronous mobile communications service based on the third generation of W-CDMA. In Korea, it is mainly provided in through videophone service. Because of the diffusion of more powerful and diversified services, along with steep advances in mobile communications technology, consumers demand a wide range of choices. However, because of the variety of technologies, which tend to overflow the market regardless of consumer preferences, consumers feel increasingly confused. Therefore, we should not adopt strategies that focus only on developing new technology on the assumption that new technologies are next-generation projects. Instead, we should understand the process by which consumers accept new forms of technology and devise schemes to lower market entry barriers through strategies that enable developers to understand and provide what consumers really want. In the Technology Acceptance Model (TAM), perceived usefulness and perceived ease of use are suggested as the most important factors affecting the attitudes of people adopting new technologies (Davis, 1989; Taylor and Todd, 1995; Venkatesh, 2000; Lee et al., 2004). Perceived usefulness is the degree to which a person believes that a particular technology will enhance his or her job performance. Perceived ease of use is the degree of subjective belief that using a particular technology will require little physical and mental effort (Davis, 1989; Morris and Dillon, 1997; Venkatesh, 2000). Perceived pleasure and perceived usefulness have been shown to clearly affect attitudes toward accepting technology (Davis et al., 1992). For example, pleasure in online shopping has been shown to positively impact consumers' attitudes toward online sellers (Eighmey and McCord, 1998; Mathwick, 2002; Jarvenpaa and Todd, 1997). The perceived risk of customers is a subjective risk, which is distinguished from an objective probabilistic risk. Perceived risk includes a psychological risk that consumers perceive when they choose brands, stores, and methods of purchase to obtain a particular item. The ability of an enterprise to revolutionize products depends on the effective acquisition of knowledge about new products (Bierly and Chakrabarti, 1996; Rothwell and Dodgson, 1991). Knowledge acquisition is the ability of a company to perceive the value of novelty and technology of the outside (Cohen and Levinthal, 1990), to evaluate the outside technology that has newly appeared (Arora and Gambaradella, 1994), and to predict the future evolution of technology accurately (Cohen and Levinthal, 1990). Consumer innovativeness is the degree to which an individual adopts innovation earlier than others in the social system (Lee, Ahn, and Ha, 2001; Gatignon and Robertson, 1985). That is, it shows how fast and how easily consumers adopt new ideas. Innovativeness is regarded as important because it has a significant effect on whether consumers adopt new products and on how fast they accept new products (Midgley and Dowling, 1978; Foxall, 1988; Hirschman, 1980). We conducted cross-national comparative research using the TAM model, which empirically verified the relationship between the factors that affect attitudes - perceived usefulness, ease of use, perceived pleasure, perceived risk, innovativeness, and perceived level of knowledge management - and attitudes toward HSDPA service. We also verified the relationship between attitudes and usage intention for the purpose of developing more effective methods of management for HSDPA service providers. For this research, 346 questionnaires were distributed among 350 students in the Republic of Korea. Because 26 of the returned questionnaires were inconsistent or had missing data, 320 questionnaires were used in the hypothesis tests. In UK, 192 of the total 200 questionnaires were retrieved, and two incomplete ones were discarded, bringing the total to 190 questionnaires used for statistical analysis. The results of the overall model analysis are as follows: Republic of Korea x2=333.27(p=0.0), NFI=0.88, NNFI=0.88, CFI=0.91, IFI=0.91, RMR=0.054, GFI=0.90, AGFI=0.84, UK x2=176.57(p=0.0), NFI=0.88, NNFI=0.90, CFI=0.93, IFI=0.93, RMR=0.062, GFI=0.90, AGFI=0.84. From the results of the hypothesis tests of Korean consumers about the relationship between factors that affect intention to use HSDPA services and attitudes, we can conclude that perceived usefulness, ease of use, pleasure, a high level of knowledge management, and innovativeness promote positive attitudes toward HSDPA mobile phones. However, ease of use and perceived pleasure did not have a direct effect on intention to use HSDPA service. This may have resulted from the fact that the use of video phones is not necessary for everyday life yet. Moreover, it has been shown that attitudes toward HSDPA video phones are directly correlated with usage intention, which means that perceived usefulness, ease of use, pleasure, a high level of knowledge management, and innovativeness. These relationships form the basis of the intention to buy, contributing to a situation in which consumers decide to choose carefully. A summary of the results of the hypothesis tests of European consumers revealed that perceived usefulness, pleasure, risk, and the level of knowledge management are factors that affect the formation of attitudes, while ease of use and innovativeness do not have an effect on attitudes. In particular, with regard to the effect value, perceived usefulness has the largest effect on attitudes, followed by pleasure and knowledge management. On the contrary, perceived risk has a smaller effect on attitudes. In the Asian model, ease of use and perceived pleasure were found not to have a direct effect on intention to use. However, because attitudes generally affect the intention to use, perceived usefulness, pleasure, risk, and knowledge management may be considered key factors in attitude development from which usage intention arises. In conclusion, perceived usefulness, pleasure, and the level of knowledge management have an effect on attitude formation in both Asian and European consumers, and such attitudes shape these consumers' intention to use. Furthermore, the hypotheses that ease of use and perceived pleasure affect usage intention are rejected. However, ease of use, perceived risk, and innovativeness showed different results. Perceived risk had no effect on attitude formation among Asians, while ease of use and innovativeness had no effect on attitudes among Europeans.

  • PDF

Respiratory Gas Exchange and Ventilatory Functions at Maximal Exercise (최대운동시의 호흡성 가스교환 및 환기기능)

  • Cho, Yong-Keun;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.6
    • /
    • pp.900-912
    • /
    • 1995
  • Background: Although graded exercise stress tests are widely used for the evaluation of cardiorespiratory performance, normal standards on respiratory gas exchange and ventilatory functions at maximal exercise in Koreans have not been well established. The purpose of this study is to provide reference values on these by sex and age, along with derivation of some of their prediction equations. Method: Symptom-limited maximal exercise test was carried out by Bruce protocol in 1,000 healthy adults consisting of 603 males and 397 females, aged 20~66 years. Among them VC, $FEV_1$ and MVV were also determined in 885 cases. All the subjects were members of a health center, excluding athletes. During the exercise, subjects were allowed to hold on to front hand rail of the treadmill for safety purpose. Results: The $VO_2\;max/m^2$, $VCO_2\;max/m^2$ and $V_E\;max/m^2$ were greater in males than in females and decreased with age. The RR max in men and women was similar but decreased slightly with age. The $V_T$ max was markedly greater in men but showed no significant changes with age in either gender. The mean of $V_T$ max/VC, $V_E$ max/MVV and BR revealed that there were considerable ventilatory reserves at maximal exercise even in older females. The regression equations of the cardinal parameters obtained using exercise time(ET, min), age(A, yr), height(Ht, cm), weight(W, kg), sex(S, 0=male; 1=female), VC(L), $FEV_1$(L) and $V_E$ max(L) as variables are as follows: $VO_2\;max/m^2$(L/min)=1.449+0.073 ET-0.007A+0.010W-0.006Ht-0.209S, $VCO_2\;max/m^2$(L/min)=1.672+0.063ET-0.008A+0.010W-0.005Ht-0.319S, VE max/$m^2$(L/min)=58.161+1.503ET-0.315A-9.871S or VE max/$m^2$(L/min)=47.873+6.548 $FEV_1$-5.715 S, and VT max(L)=1.497+0.223VC-0.493S. Conclusion: Respiratory gas exchange and ventilatory variables at maximal exercise were studied in 1,000 non-athletes by Bruce protocol. During exercise, the subjects were allowed to hold on to hand rail of the treadmill for safety purpose. We feel that our results would provide ideal target values for patients and healthy individuals to be achieved, since our study subjects were members of a health center whose physical fitness levels were presumably higher than ordinary population.

  • PDF

Effects of Percutaneous Balloon Mitral Valvuloplasty on Static Lung Function and Exercise Performance (승모판협착증 환자에서 경피적 풍선확장판막성형술의 폐기능 및 운동부하 검사에 대한 효과)

  • Kim, Yong-Tae;Kim, Woo-Sung;Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Kim, Jae-Joong;Park, Seong-Wook;Park, Seung-Jung;Lee, Jong-Koo;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.1
    • /
    • pp.1-10
    • /
    • 1994
  • Background: Patients with mitral stenosis(MS) have been demonstrated to have a variable degree of pulmonary dysfunction and exercise impairment. The hemodynamic changes of MS can be reversed after percutaneous mitral balloon valvuloplasty(PMV), but the extent and time course of the imporvement in pulmonary function and exercise capacity are not defined. Methods: In order to investigate the early(3 weeks or less)and late(3 months or more) effects of PMV on pulmonary function and determine if the pulmonary dysfunction is reversible even in patients with moderate to severe pulmonary hypertension, we performed the spirometry, measurements of diffusing capacity and lung volumes, and incremental exercise tests in patients with MS before and after PMV. Results: In 46 patients with MS(age: $40{\pm}12$years, male to female ratio: 1:2, mitral valve area: $0.8{\pm}0.2cm^2$) there was a significant increase in FVC(P<0.0025), $FEV_1$(P<0.001), $FEF_{25-75%}$(P<0.001, $FEF_{50%}$(P<0.001), PEF(P<0.0005), MVV(P<0.005), $\dot{V}O_2$max (P<0.0001), and AT(P<0.0001) after average 10 days of PMV. Also there was a significant decrease in DLco(P<0.0001) and DL/VA(P<0.0001). At later($5{\pm}2$months) follow-up in 11 patients, there was no further improvement in any parameters of pulmonary function and exercise test. Twenty nine patients with sinus rhythm were divided into 16 patients with pulmonary arterial pressure(PAP) more than 35mmHg and/or tricuspid regurgitation grade n or more(group A) and 13 patients with PAP less than 35mmHg(group B). Group A Patients had significantly lower FVC(P<0.001), $FEV_1$(P<0.001), DLco(P<0.05), $\dot{V}O_2$ max(P<0.025) and mitral valve area(P<0.025) than group B patients. Group A patients after PMV, showed significant increase in FVC(P<0.001), maximum $O_2$ pulse(P<0.00001) and $\dot{V}O_2$ max(P<0.00025). Both group showed an increase in AT(P<0.0001, P<0.005), but group A showed greater decrease in $\dot{V}E/\dot{V}O_2$ and $\dot{V}E/\dot{V}CO_2$ both at AT(P<0.001, P<0.001) and $\dot{V}O_2$ max(P<0.0001, P<0.0001) after PMV compared with group B. Conclusion: These data suggest that patients with MS can show increased pulmonary function and exercise performance within 1 month after PMV. Patients with moderate to severe pulmonary hypertension had a significant increase in exercise performance compared with those with mild to no pulmonary hypertension and it is thought to be related to a significat decrease of ventilation for a given oxygen consumption at maximum exercise.

  • PDF

The Comparison of Results Among Hepatitis B Test Reagents Using National Standard Substance (국가 표준물질을 이용한 B형 간염 검사 시약 간의 결과 비교)

  • Lee, Young-Ji;Sim, Seong-Jae;Back, Song-Ran;Seo, Mee-Hye;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.203-207
    • /
    • 2010
  • Purpose: Hepatitis B is infection caused by Hepatitis B virus (HBV). Currently, there are several methods, Kits and equipments for conducting Hepatitis B test. Due to ununiformed methods, it would cause some differences. To manage these differences, it needs process evaluating function of test system and reagent using particular standard substance. The aim of this study is to investigate tendency of RIA method's reagent used in Asan Medical Center through comparing several other test reagents using national standard substance. Materials and Methods: The standard substance in National Institute of Food and Drug Safety Evaluation's biology medicine consists of 5 things, 4 antigens and 1 antibody. We tested reagents using A, B company's Kits according to each test method. All tests are measured repeatedly to obtain accurate results. Results: Test result of "HBs Ag Mixed titer Performance panel" is obtained match rate compared S/CO unit standard with RIA method and EIA 3 reagents, CIA 2 reagents is that company A's reagent is 94.4% (17/18), 83.3% (15/18), B is 88.9% (16/18), 77.8% (14/18). Test result of "HBs Ag Low titer Performance panel" is obtain that EIA 2 reagents is shown 7 posive results, CIA 3 reagents is 11, and RIA method's company A's reagent is 3, B is 2 of 13 in low panel. "HBV surface antigen 86.76 IU/vial" tested dilution. A is obtain positive results to 600 times(0.14 IU/mL), B is 300 times (0.29 IU/mL). Case of "HBV human immunoglobulin 95.45 IU/vial", A is shown positive result to 10,000 times (9.5 mIU/mL) and B is 4,000 times (24 mIU/mL). Test result of "HBs Ag Working Standards 0.02~11.52 IU/mL" is shown that Company A's kit concentration level was 0.38IU/mL, company B was 2.23 IU/mL and higher level of concentration was positive results. Conclusion: When comparing various test reagents and RIA method according to National Standard substances for Hepatitis B test, we recognized that there were no significant trends between reagents. For hepatitis B virus antigen-antibody titers even in parts of the test up to 600 times the antigen, antibodies to 10,000 times the maximum positive results could be obtained. Therefore, we confirmed that results from Asan Medical Center are performed smoothly by reagents and system for hepatitis B virus test.

  • PDF

Gender Differences in Pain in Cancer Patients (성별에 따른 암환자의 통증 차이)

  • Kim, Hyun-Sook;Lee, So-Woo;Yun, Young-Ho;Yu, Su-Jeong;Heo, Dae-Seog
    • Journal of Hospice and Palliative Care
    • /
    • v.4 no.1
    • /
    • pp.14-25
    • /
    • 2001
  • Purpose : To determine whether there exist gender differences in pain in Korean cancer patients and whether the depression and performance that are often expressed differently between men and women with cancer interact with pain. Method : The results of survey were collected from 140 in- and out-patients (78 male and 62 female) who had cancer treatment at one of the university hospital in Seoul for four months from February of 1999. The severity and interference of pain were examined with the self-reported survey based on Korean version of Brief Pain Inventory (BPI-K). Demographic and clinical information for all patient were compiled by reviewing their medical records, and the level of depression was examined with the Korean version of Beck Depression Inventory (BDI-K). Usual statistical methods, e.g., frequences, means and SDs were used to characterize the sample. The chi-square tests for categorical data and t-test for numerical data were used for group comparison. And the correlation between variables were performed using Pearson correlation coefficient. Resuts : 1) The mean scores of the worst pain for last 24-hours measured with the pain severity of BPI-K were 5.77 in male and 6.45 in female. The pain interference of BPI-K in men was in the order of mood (5.49), enjoy (5.36), and work (5.00), and in women were work (7.48), enjoy (7.16), and mood (6.53). 2) In pain severity, significant difference was found between men and women in the average pain for last 24-hours (t=-2.130, P=.035). In pain interference, significant difference was found between men and women in activity (t=-2.450, P=.015), mood (t=-2,321, P=.022), walk (t=-2.762, P=.007), work (t=-4.946, P=.000), relate (t=-2.595, P=.010), sleep (t=-2.071, P=.040), enjoy (t=-3.198, P=.001). 3) It was found that the items of pain and depression are significantly correlated in men but not in women. Men also exhibited higher correlation in the items of pain and performance status than women. Conclusions : Women report significantly greater average pain for last 24-hours and for all items of pain interference than men. Pain and depression are significantly correlated in men. The results of this study suggest that gender differences in pain should be considered for planning effective pain management program.

  • PDF

A Study on the Establishment of Acceptable Range for Internal Quality Control of Radioimmunoassay (핵의학 검체검사 내부정도관리 허용범위 설정에 관한 고찰)

  • Young Ji, LEE;So Young, LEE;Sun Ho, LEE
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.2
    • /
    • pp.43-47
    • /
    • 2022
  • Purpose Radioimmunoassay implement quality control by systematizing the internal quality control system for quality assurance of test results. This study aims to contribute to the quality assurance of radioimmunoassay results and to implement systematic quality control by measuring the average CV of internal quality control and external quality control by plenty of institutions for reference when setting the laboratory's own acceptable range. Materials and Methods We measured the average CV of internal quality control and the bounce rate of more than 10.0% for a total of 42 items from October 2020 to December 2021. According to the CV result, we classified and compared the upper group (5.0% or less), the middle group (5.0~10.0%) and the lower group (10.0% or more). The bounce rate of 10.0% or more was compared by classifying the item of five or more institutions into tumor markers, thyroid hormones and other hormones. The average CV was measured by the overall average and standard deviation of the external quality control results for 28 items from the first quarter to the fourth quarter of 2021. In addition, the average CV was measured by the overall average and standard deviation of the proficiency results between institutions for 13 items in the first half and the second half of 2021. The average CV of internal quality control and external quality control was compared by item so we compared and analyzed the items that implement well to quality control and the items that require attention to quality control. Results As a result of measuring the precision average of internal quality control for 42 items of six institutions, the top group (5.0% or less) are Ferritin, HGH, SHBG, and 25-OH-VitD, while the bottom group (≤10.0%) are cortisol, ATA, AMA, renin, and estradiol. When comparing more than 10.0% bounce rate of CV for tumor markers, CA-125 (6.7%), CA-19-9 (9.8%) implemented well, while SCC-Ag (24.3%), CA-15-3 (26.7%) were among the items that require attention to control. As a result of comparing the bounce rate of more than 10.0% of CV for thyroid hormones examination, free T4 (2.1%), T3 (9.3%) showed excellent performance and AMA (39.6%), ATA (51.6%) required attention to control. When comparing the bounce rate of 10.0% or more of CV for other hormones, IGF-1 (8.8%), FSH (9.1%), prolactin (9.2%) showed excellent performance, however estradiol (37.3%), testosterone (37.7%), cortisol (44.4%) required attention to control. As a result of measuring the average CV of the whole institutions participating at external quality control for 28 items, HGH and SCC-Ag were included in the top group (≤10.0%), however ATA, estradiol, TSI, and thyroglobulin included in bottom group (≥30.0%). Conclusion As a result of evaluating 42 items of six institutions, the average CV was 3.7~12.2% showing a 3.3 times difference between the upper group and the lower group. Cortisol, ATA, AMA, Renin and estradiol tests with high CV will require continuous improvement activities to improve precision. In addition, we measured and compared the overall average CV of the internal quality control, the external quality control and the proficiency between institutions participating of six institutions for 41 items excluding HBs-Ab. As a result, ATA, AMA, Renin and estradiol belong to the same subgroup so we require attention to control and consider setting a higher acceptable range. It is recommended to set and control the acceptable range standard of internal quality control CV in consideration of many things in the laboratory due to the different reagents and instruments, and the results vary depending on the test's proficiency and quality control materials. It is thought that the accuracy and reliability of radioimmunoassay results can be improved if systematic quality control is implemented based on the set acceptable range.

The Evaluation of Proficiency Test between Radioimmunoassay and Chemiluminescence Immunoassay (방사면역측정법과 화학발광면역측정법간의 숙련도 비교평가)

  • Noh, Gyeong-Woon;Kim, Tae-Hoon;Kim, Ji-Young;Kim, Hyun-Joo;Lee, Ho-Young;Choi, Joon-Young;Lee, Byoeng-Il;Choe, Jae-Gol;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.116-124
    • /
    • 2011
  • Purpose: To establish accurate external quality assurance (EQA) test, cross institutional and modality tests were performed using WHO certificated reference material (CRM) and same pooled patients serum. Materials and Methods: Accuracy and precision were evaluated using CRM and pooled patients' serum for AFP, CEA, PSA, CA 125, CA 19-9, T3, T4, Tg, TSH. To evaluate the accuracy and precision, recover test and coefficient variation were measured. RIA test were performed in major 5 RIA laboratory and EIA (CLIA) test were done in 5 major EIA laboratory. same sample of CRM and pooled serum were delivered to each laboratory. Results: In 2009, mean precision of total tumor marker of RIA was $14.8{\pm}4.2%$ and that of EIA(CLIA) was $19.2{\pm}6.9%$. In 2010, mean precision of 5 tumor marker and T3, T4, Tg, TSH was $13.8{\pm}6.1%$ in RIA and $15.5{\pm}7.7%$ in EIA (CLIA). There was no significant difference between RIA and EIA. In RIA, the coefficient variations (CV) of AFP, CEA, PSA, CA 125, T3, T4, TSH were within 20%. The CV of CA 19-9 was over 20% but there was no significant difference with EIA (CLIA) (p=0.345). In recovery test using CRM, AFP, PSA, T4, TSH showed 92~103% of recovery in RIA. In recovery test using commercial material, CEA, CA 125, CA 19-9 showed relatively lower recovery than CRM but there was no significant difference between RIA and EIA (CLIA). Conclusion: By evaluating the precision and accuracy of each test, EQA test could more accurately measured the quality of each test and performance of laboratory.

  • PDF

Assessment of nutritional status of patients with chronic obstructive pulmonary disease (만성 폐쇄성 폐질환 환자의 영양상태 평가)

  • Park, Kwang Joo;Ahn, Chul Min;Kim, Hyung Jung;Chang, Joon;Kim, Sung Kyu;Lee, Won Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.93-103
    • /
    • 1997
  • Background : Malnutrition is a common finding in patients with chronic obstructive pulmonary disease, especially in the emphysema group. Although the mechanism of malnutrition is not confirmed, it is believed to be a relative deficiency caused by hypermetabolism due to increased energy requirements of the respiratory muscles, rather than a dietary deficiency. Malnutrition in chronic obstructive pulmonary disease is not a merely coincidental finding. It is known that the nutritional status correlates with physiologic parameters including pulmonary function, muscular power, and exercise performance, and is one of the important and independent prognostic factors of the disease. Methods : Patients with chronic obstructive pulmonary disease Yongdong Severance Hospital from May, 1995 to March, 1996 and age-matched healthy control group were studied. Survey of nutritional intake, anthropometric measurements and biochemical tests were done to assess nutritional status. Relationship between nutritional status and FEV1 (forced expiratory volume at one second), which was a significant functional parameter, was assessed. Results : 1) The patient group was consisted of 25 males with mean age of 66.1years and FEV1 of $42{\pm}14%$ of predicted values. The control group was consisted of 26 healthy males with normal pulmonary function, whose mean age was 65.0 years. 2) The ratio of calorie intake/calorie requirement per day was $107{\pm}28%$ in the patient group, and $94{\pm}14%$ in the control group, showing a tendency of more nutritional intake in patient group(B=0.06). 3) There were significant differences between the patient group and control group in percent ideal body weight(92.8% vs 101.6%, p=0.024), body mass index($20.0kg/m^2$ VS $21.9kg/m^2$, p=0.015), and handgrip strength(29.0kg vs 34.3kg, p=0.003). However, there were no significant differences in triceps skinfold thickness, mid-arm muscle circumference, albumin, and total lymphocyte count between two groups. Percentage of underweight population was 40%(10/25) in the patient group, and 15%(4/26) in the control group. 4) The percent ideal body weight, triceps skinfold thickness, and mid-arm muscle circumference had significant correlation with FEV1. Conclusion : The patients with chronic obstructive pulmonary disease showed significant depletion in nutritional parameters such as body weight and peripheral muscle strength, while absolute amount of dietary intake was not insufficient. Nutritional parameters were well correlated with FEV1.

  • PDF

Structural Analysis of Concrete-filled FRP Tube Dowel Bar for Jointed Concrete Pavements (콘크리트 포장에서 FRP 튜브 다웰바의 역학적 특성 분석)

  • Park, Jun-Young;Lee, Jae-Hoon;Sohn, Dueck-Su
    • International Journal of Highway Engineering
    • /
    • v.13 no.3
    • /
    • pp.21-30
    • /
    • 2011
  • As well known, dowel bars are used to transfer traffic load acting on one edge to another edge of concrete slab in concrete pavement system. The dowel bars widely used in South Korea are round shape steel bar and they shows satisfactory performance under bending stress which is developed by repetitive traffic loading and environment loading. However, they are not invulnerable to erosion that may be caused by moisture from masonry joint or bottom of the pavement system. Especially, the erosion could rapidly progress with saline to prevent frost of snow in winter time. The problem under this circumstance is that the erosion not only drops strength of the steel dower bar but also comes with volume expansion of the steel dowel bar which can reduce load transferring efficiency of the steel dowel bar. To avoid this erosion problem in reasonable expenses, dowers bars with various materials are being developed. Fiber reinforced plastic(FRP) dower that is presented in this paper is suggested as an alternative of the steel dowel bar and it shows competitive resistance against erosion and tensile stress. The FRP dowel bar is developed in tube shape and is filled with high strength no shrinkage. Several slab thickness designs with the FRP dowel bars are performed by evaluating bearing stress between the dowel bar and concrete slab. To calculated the bearing stresses, theoretical formulation and finite element method(FEM) are utilized with material properties measured from laboratory tests. The results show that both FRP tube dowel bars with diameters of 32mm and 40mm satisfy bearing stress requirement for dowel bars. Also, with consideration that lean concrete is typical material to support concrete slab in South Korea, which means low load transfer efficiency and, therefore, low bearing stress, the FRP tube dowel bar can be used as a replacement of round shape steel bar.

Application of Nano Fe°-impregnated Biochar for the Stabilization of As-contaminated Soil (비소 오염토양의 안정화를 위한 나노 Fe° 담지 바이오차 적용 연구)

  • Choi, Yu-Lim;Angaru, Ganesh Kumar Reddy;Ahn, Hye-Young;Park, Kwang-Jin;Joo, Wan-Ho;Yang, Jae-Kyu;Chang, Yoon-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.5
    • /
    • pp.350-362
    • /
    • 2020
  • In this study, nano Fe°-impregnated biochar (INPBC) was prepared using pruning residues and one-pot synthetic method and evaluated its performance as an amendment agent for the stabilization of arsenic-contaminated soil. For the preparation of INPBC, the mixture of pruning residue and Fe (III) solution was heated to 220℃ for 3hr in a teflon-sealed autoclave followed by calcination at 600℃ under N2 atmosphere for 1hr. As-prepared INPBC was characterized using FT-IR, XRD, BET, SEM. For the stabilization test of as-prepared INPBC, As-contaminated soils (Soil-E and Soil-S) sampled from agricultural sites located respectively near E-abandoned mine and S-abandoned mine in South Korea were mixed with different of dosage of INPBC and cultivated for 4 weeks. After treatment, TCLP and SPLP tests were conducted to determine the stabilization efficiency of As in soil and showed that the stabilization efficiency was increased with increasing the INPBC dosage and the concentration of As in SPLP extractant of Soil-E was lower than the drinking water standard level of Ministry of Environment of South Korea. The sequential fractionation of As in the stabilized soils indicated that the fractions of As in the 1st and 2nd stages that correspond liable and known as bioavailable fraction were decreased and the fractions of As in 3rd and 4th stages that correspond relatively non-liable fraction were increased. Such a stabilization of As shows that the abundant nano Fe° on the surface of INPBC mixed with As-contaminated soils played the co-precipitation of As leaching from soil by surface complexation with iron. The results of this study may imply that INPBC as a promising amendments for the stabilization of As-contaminated soil play an important role.