KASI (Korea Astronomy and Space Science Institute) has developed an SLR (Satellite Laser Ranging) system since 2008. The name of the development program is ARGO (Accurate Ranging system for Geodetic Observation). ARGO has a wide range of applications in the satellite precise orbit determination and space geodesy research using SLR with mm-level accuracy. ARGO-M (Mobile, bistatic 10 cm transmitting/40 cm receiving telescopes) and ARGO-F (Fixed stationary, about 1 m transmitting/receiving integrated telescope) SLR systems development will be completed by 2014. In 2011, ARGO-M system integration was completed. At present ARGO-M is in the course of system calibration, functionality, and performance tests. It consists of six subsystems, OPS (Optics System), TMS (Tracking Mount System), OES (Opto-Electronic System), CDS (Container-Dome System), LAS (Laser System) and AOS (ARGO Operation System). In this paper, ARGO-M system structure and integration status are introduced and described.
Proceedings of the Korean Society of Propulsion Engineers Conference
/
2017.05a
/
pp.99-103
/
2017
As a development test of the 75-tonf LOx/Kerosene liquid rocket engine for KSLV-II first Stage Engine, hot firing test of 75-tonf engine are performed. The current status of development test on first stage 75-tonf engine system including combustion chamber, turbopump, gas generator, propellant supply system are presented. During the 75tonf engine test campaign, the development of startup sequence of LOx-Kerosene engine system, engine startup using pyrostarter, ignition of gas generator, steady operation and engine shutdown is successfully performed. As a passenger test during engine hot firing tests, Thrust Vector Control system (TVC) of the engine are also evaluated during engine hot firing test. The results of hot firing test of 75-tonf thrust engine system will be used for the design confirmation and performance evaluation of 75 tonf engine system for KSLV-II first Stage.
Violanti, John M.;Ma, Claudia C.;Fekedulegn, Desta;Andrew, Michael E.;Gu, Ja K.;Hartley, Tara A.;Charles, Luenda E.;Burchfiel, Cecil M.
Safety and Health at Work
/
v.8
no.1
/
pp.36-41
/
2017
Background: Police work is generally sedentary although there may be situations that require physical endurance and strength, such as foot chases and arresting suspects. Factors such as excessive body fat can impede an officer's physical ability to deal with such occurrences. Our objective was to examine associations between officers' body fat percentage (BF%) and performance on a standardized fitness protocol. Methods: Data were obtained from fitness screening among 1,826 male and 115 female officers in a large US police agency. The screening consisted of a 2.4-km run, push-ups, sit-ups, and sit-and-reach test. Sex-specific body fat percentages were estimated from skinfold thickness measured using calipers. Linear regression models were used to examine unadjusted and adjusted mean scores of fitness tests across BF% tertiles. Results: The prevalence of overall fitness was 4.3 times greater in male officers and 3.6 times greater in female officers having the lowest BF% tertile compared with the highest tertile (30.3% vs 7.1% and 46.0% vs 12.8%, respectively). BF% was linearly and positively associated with the time of 2.4-km run (p < 0.001), and linearly and inversely associated with the number of push-ups (p < 0.001), sit-ups (p < 0.001), and the distance of sit-and-reach (p < 0.001) in men. Similar associations were observed in women with the exception of sit-and-reach (p = 0.122). Associations were independent of age, race/ethnicity, rank, and duty station. Conclusion: Overall, BF% was inversely associated with fitness levels in male and female officers. Future longitudinal studies should be initiated to explore the potentially causal relationship between BF% and fitness in law enforcement officers.
The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA), the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility-the advanced core-cooling mechanism experiment (ACME)-was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA) transient. Two comparison test groups-a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI) line break-were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the potential negative effects on the passive core cooling performance caused by nitrogen injection during the SBLOCA transient.
Journal of the Society of Naval Architects of Korea
/
v.34
no.1
/
pp.11-23
/
1997
This paper contains a new approach to blade section design method for marine propellers. The hydrodynamic characteristics of 2-D section are highly influenced by its geometrical parameters i.e., thickness and camber distributions and leading edge radius etc. To consider fully turbulent flow field near 2-D section. the finite volume method with k-${\varepsilon}$ turbulent model which solve Reynolds time averaged Navier-Stokes(RANS) equation is applied. In this study, O-type grid system that can provide many calculation points on blade surface is used. The results were compared with those of the experiment of NACA0012 to confirm the accuracy of the developed codes. The goal of this study is the development of a blade section with high efficiency and low drag. To achieve this, we carried out the tests of lift, drag and cavitation characteristics in cavitation tunnel. The results of experiment were compared with numerical results in order to validate the proposed blades design method. By comparing the numerical results with the experiments, we found that the new blade section, KH28 allows superior performance in efficiency and cavitation avoidance characteristics. We further investigated the blade section design method and an application study of this section, KH28 to apply to the marine propeller. In order to improve the accuracy of numerical results on prediction of lift and drag, we conclude here that the 2-layer boundary model must be used.
The dissolution test method and an analytical procedure by HPLC were developed and validated for nafronyl oxalate capsules and tramadol hydrochloride capsules. These drugs were not yet characterized by the dissolution specifications in the Korean Pharmaceutical Codex. So, with each reference and test drugs, we did the preliminary and standard experiments based on the Korean Pharmacopeia Guideline of dissolution testing for solid oral dosage forms. The dissolution test for nafronyl oxalate capsules was carried out under sink conditions as follows: dissolution medium phosphate buffer pH 6.8, paddle rotation speed 100 rpm and vessel volume 900 ml. More than 80% of its label amount was released within 30 min in this method. Also the dissolution test for tramadol hydrochloride capsules was carried out under sink conditions as follows: dissolution medium water, paddle rotation speed 50 rpm and vessel volume 900 ml. More than 90% of its label amount was released within 15 min in this method. The dissolution samples were analyzed with a validated HPLC analytical procedure. The analytical methodology showed acceptable values in terms of specificity, linearity, precision and accuracy. The dissolution test methods described above were adequate for the purpose and may be proposed as a pharmacopeial standard to assess the performance of nafronyl oxalate capsules and tramadol hydrochloride capsules. Furthermore, the outcomes of this study were expected to help create an environment where safe and high quality drugs would be distributed on the domestic market making contributions to advancing public health.
Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
/
v.32
no.2
/
pp.163-171
/
2014
Based on the GPS/IMU integration, the car navigation has unstable conditions as well as drastically reduces accuracies in urban region. Nowadays, many cars mounted the camera to record driving states. If the ground coordinates of street furniture are known, the position and attitude of camera can be determined through SPR(Single Photo Resection). Therefore, an estimated position and attitude from SPR can be applied measurements in Kalman filter for updating errors of navigation solutions from GPS/IMU integration. In this study, the GPS/IMU/SPR integration algorithm was developed in loosely coupled modes through extended Kalman filters. Also, in order to analyze performances of GPS/IMU/SPR, simulation tests were conducted in GPS signal reception environments and the GCPs (Ground Control Points) distributions. In fact, the position and attitude gathered from GPS/IMU/SPR integration are more precise than the position and attitude from GPS/IMU integration. When IPs (image points), corresponded to GCPs, were concentrated in the center of image, the position error in the optical axis respectively increased. To understand effects from SPR, we plan to carry additional test on the magnitude of GCP, IP and initial exterior orientation errors.
The effect of supplementation with docosahexaenoic acid into n-3 fatty acid deficient diet on improvement of loaming related brain function was investigated. On the second day after conception, Sprague Dawley strain dams were subjected to a diet containing either n-3 fatty acid deficient (Def) or n-3 fatty acid deficient + docosahexaenoic acid (Def+DHA). After weaning, male pups were fed on the same diet of their respective dams until adulthood. Motor activity and Morris water maze tests were measured at 10 weeks old. In motor activity test, there were no statistically significant differences in moving time and moving distance between the Def and Def+DHA diet groups. The n-3 fatty acid deficient with DHA (Def+DHA) group exhibited a shorter escape latency, swimming time and swimming distance (P<0.05) compared to the n-3 fatty acid deficient group (Def) but there was no difference in resting time and swimming speed between the experimental diet groups. In memory retention trial, the number of crossing of the platform position (region A) was significantly greater than those of other regions for the Def+DHA group. However, the Def group swam randomly without preference for the provisions platform location, indicating poorer memory retention. From those results, supplementation with DHA into the n-3 fatty acid deficient diet improved the spatial loaming ability in rats as assessed by Morris water maze test.
The effect of adding docosahexaenoic acid into an n-3 fatty acid adequate diet on the improvement of learning related brain function was investigated. On the second day after conception, Sprague Dawley strain dams were subjected to a diet containing either n-3 fatty acid adequate (Adq, 3.4% linolenic acid) or n-3 fatty acid adequate+docosahexaenoic acid (Adq+DHA, 3.31%linolenic acid plus 9.65% DHA). After weaning, male pups were fed on the same diet of their respective dams until adulthood. Motor activity and Morris water maze tests were measured at 10 weeks. In the motor activity test, there were no statistically significant differences in moving time and moving distance between the Adq and Adq+DHA diet groups. The n-3 fatty acid adequate with DHA (Adq+DHA) group tended to show a shorter escape latency, swimming time and swimming distance compared to the n-3 fatty acid adequate group (Adq), but the differences were not statistically significant. There was no difference in resting time, but the Adq+DHA group showed a higher swimming speed compared to the Adq group. In memory retention trials, the numbers of crossing of the platform position (region A), in which the hidden platform was placed, were significantly greater than those of other regions for both Adq and Adq+DHA groups. Based on these results, adding DHA into the n-3 fatty acid adequate diet from gestation to adulthood tended to induce better spatial learning performance in Sprague Dawley rats as assessed by the Morris water maze test, although the difference was not significant.
The purpose of this study was to test whether Yoga exercise, one of muscle relaxation, helps to relieve chronic low back paln. Sample were selected from nurses who were worked at K medical center in the period from March 18 to April 23, 1996. The sample size was fifteen. The research design was one-group pretest-posttest design. To test the major research question, this study had the following procedure. The pretest included measuring individuals' degree of pain and discomfort depending on the scope and types of an range of motion, and their pain by their activity of daily living(ADL). The treatment was conducted twice every other week. The reason why this study had twice observations was to control history effect and maturation which treat internal validity in the research design of this study. In this research design, a treatment was to expose Yoga exercise to samples. The exercise was taken in 30 minutes per day for four days in a week (Two consecutive days and twice every other day). The posttest included re-measuring the individuals' the degree of pain and discomfort, and their pain by their ADL. Several hypotheses concerning effect of Yoga exercise was analyzed by the paired t-test, comparing the difference scores between pre and post tests. The results of this study was as follows. The first hypothesis that the post-treatment group taking the Yoga exercise had the pain score lower than the pre-treatment group was supported(t=3.31, p=.005). The second hypothesis that the discomfort score of the post-treatment group had lower than does that of the pre-treatment group was supported(t=2.75, p=.016). The third hypothesis that the post-treatment group had the pain score by ADL lower than does the pre-treatment group was supported(t=5.52, p=.000). In summary, this study examined the effect of a yoga exercise, one of muscle relaxation, on those who were suffered from chronic low back pain. The effect measured by the degree of pain and discomfort with a visual analog scale was statistically significant. The degree of pain according to postures in ADL also showed statistical significance. These findings showed that a yoga exercise was effective to alleviation of chronic low back pain. A pretest-posttest control group design, however, needs to get more accurate results since the design satisfies Internal validity. Consequently, yoga as an exercise cure improves an interaction between muscles and articulations, and performance of ADL for those suffered from chronic low back pain. Furthermore, this positive impact may be an effective method as nursing intervention for their physical, mental, emotional, social, and psychological recovery.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.