• 제목/요약/키워드: Performance Tester

검색결과 302건 처리시간 0.025초

LED 프로젝터 방열용 히트싱크의 성능평가 (Performance Evaluation of Heat Sink for Cooling of LED Projector)

  • 이경용;최영석;전동순;김선창;손광은
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1167-1171
    • /
    • 2008
  • The flow and thermal performance of the skiving and louver fin type heat sinks for the cooling system of the small LED projector were experimentally evaluated. A small fan tester based on AMCA standards was used to control and measure the air flow rate into the heat sink. Three heat blocks were used to simulate the heat and light sources(red, green and blue) of the small LED projector. We measured the pressure drop, temperatures and input power at the specific air flow rate and discussed those results. As a result, it is found that the louver fin type heat sink has higher pressure drop and lower thermal resistance than the skiving type. From the comparison of the temperature of the heat block between skiving and louver fin type, the louver fin type heat sink was found to be more suitable for cooling the high power heat source than skiving type. The thermal performance of the fan-sink(louver fin type) system was discussed with the picture taken by a thermal video.

  • PDF

신한옥 침실 공간의 기밀성능 평가 연구 (A Study on the Airtightness Performance of New Han-ok Bedrooms)

  • 이주엽;장현충;이태강;송민정;김선우
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.79-89
    • /
    • 2013
  • The purpose of this study is to evaluate the airtightness performance of New Han-ok and to supply fundamental data for standards establishment. Air leakage testings were accomplished by means of blower door test in 26 bedrooms of 16 Han-oks located in Jeonnam happy villages. Followings are results. 1) Air change per hour at 50 Pa(ACH50) is located on 8.42~78.38. 2) No correlation between ACH50 and volumes, floor area, above grade surface area. 3) The more wood structural elements are exposed, attached spaces, wooden sliding and casement windows, the less airtightness performance. 4) An Airtightness with ACH50/20(NL, Normalized leakage) is located on 0.42~3.92 and building leakage class following F(4%), G(11%, sufficiently leaky, No need mechanical ventilation), H(4%, Need of cost-effective tightening), I(31%), J(50%) by a single-story house the normalized leakage of ASHRAE.

토사지반 EPB TBM의 굴진성능 및 커팅툴 마모량에 관한 실험장비 개발 및 기초연구 (Development of testing apparatus and fundamental study for performance and cutting tool wear of EPB TBM in soft ground)

  • 김대영;강한별;신영진;정재훈;이재원
    • 한국터널지하공간학회 논문집
    • /
    • 제20권2호
    • /
    • pp.453-467
    • /
    • 2018
  • 쉴드 TBM 공사에서 굴진율 예측과 마모량 예측은 설계 및 시공 단계에서 공사비와 공기를 추정하는데 매우 중요한 요소이다. 암반지반용 TBM의 경우 실험이나 축적된 현장 data를 기반으로 CSM 모델, NTNU 모델 등이 커터 마모량부터 굴진율 예측까지 널리 사용되고 있으나, 토사지반용 TBM은 지반의 복잡성과 정확한 실험방법의 부재로 인해 이를 정확하게 예측할 수 있는 모델이 없는 실정이다. 본 연구에서는 기존에 존재하는 토사지반용 TBM 실험장치들의 단점을 개선하여 TBM 굴착과정을 모사한 실험 장치(Soil Abrasivity Penetration Test, SAPT)를 개발하였다. 회전당 관입 깊이, RPM, 첨가재(foam) 배합비 및 농도 등의 TBM 굴진에 영향을 미치는 주요 변수들에 대한 시험을 실시하여 추력, 토크 등의 변화를 살펴보고 마모량을 측정하였다. 모래(규사) 70%와 점토(일라이트) 30%로 조성된 인공시료에 대한 실험 결과 foam 배합비가 굴진성능과 마모량에 주요한 영향을 끼치는 것으로 나타났다.

저온 성능이 향상된 Calcium Sulfonate 그리스의 합성 및 트라이볼로지 특성 연구 (A Study on the Synthesis and Tribological Characteristics of Calcium Sulfonate Grease with Improved Low-temperature Performance)

  • 김광태;박현호;이창섭
    • 공업화학
    • /
    • 제34권4호
    • /
    • pp.434-443
    • /
    • 2023
  • 세계적으로 가장 많이 사용되고 있는 리튬 그리스의 대체 물질로서 calcium sulfonate 그리스를 합성하여 성능을 개선하였다. Calcium sulfonate 그리스의 저온성 문제를 해결하기 위하여 PAO (poly alpha olefin) 기반의 기유와 증주제를 도입하였다. 본 연구에서는 파라핀 오일과 PAO 기반의 기유와 증주제로 calcium sulfonate 그리스 3종을 합성하였으며, PAO 기반의 기유와 수산화 리튬, 12-hydroxy stearic acid, sebacic acid의 비누화 반응으로 리튬 그리스 1종을 합성하였다. 합성한 calcium sulfonate 그리스 3종과 리튬 그리스의 형태, 미세 구조 및 작용기는 SEM 및 FT-IR로 분석하였다. 저온 특성은 rheometer, low temperature torque로 측정하였고, 트라이볼로지 특성은 four ball lubricant tester, SRV로 측정하였다. 그 결과, PAO 기반의 기유와 증주제로 합성된 calcium sulfonate 그리스는 -40℃에서도 유동할 수 있었으며, 기존 calcium sulfonate 그리스의 저온 특성의 한계점을 극복하였다. 또한 합성한 calcium sulfonate 그리스는 PAO 기유로 합성된 리튬 그리스보다 우수한 내마모성, 내하중성, 마찰계수, 내열성, 점착성 및 내부식성을 보였으므로 상업적으로 기존의 리튬 그리스를 대체할 수 있을 것으로 기대된다.

ATM 망에서 셀 레벨 및 프레임 레벨 성능 시험 프레임워크에 대한 연구 (A Study on Framework for Cell-level and Frame-level Performance Testing in ATM Network)

  • 안성수;최영복;이준원;김성운
    • 한국정보처리학회논문지
    • /
    • 제6권6호
    • /
    • pp.1598-1608
    • /
    • 1999
  • ATM 망의 성능시험은 다양한 성능 인자를 측정하고 이를 분석함으로써 이를 분석함으로써 수행 가능한 망의 최대 수율, 즉 망의 성능을 평가함으로써 수행된다. 그러나, 지금까지 ATM 망에 대한 성능시험 방법 및 체계의 부재로 같은 시험 대상물에 대해서도 시험수행자에 따라 성능 측정의 결과가 크게 좌우되었다. 본 논문에서는 ATM 망을 대상으로 수행되는 성능 시험의 개념을 셀 레벨 및 프레임 레벨로 나누어 설명하며, 각각에 대해 성능 파라미터 및 성능 측정 방법론을 정의하고 성능 측정을 위한 시험 환경과 성능 평가시의 고려 사항을 기술함으로써 ATM 성능 시험의 전반적인 프레임워크를 제안한다.

  • PDF

제연댐퍼 누설량 시험에 관한 연구 - 제연시스템의 성능위주설계를 위하여 - (A Study on Leaking amount Test of Control Damper - For a Performance Based Designed of Smoke Control System -)

  • 최규출;송윤석;차종호
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.131-137
    • /
    • 2009
  • 본 연구에서는 AMCA Standard 500-D-98과 관련하여 여러 시험의 조건 중 제연댐퍼의 누설량을 측정하고자 한다. 이에 본 연구의 결과로서 설계, 도면검토, 성능검사에 공학적 시험자료를 이용한 제연댐퍼의 누설량 성능곡선도 등을 적용하여 제연시스템의 올바른 설계법과 검사법을 정립하여 기술에 대한 이해와 성능이 확보되도록 한다. 또한 성능곡선도의 성능판단에 의한 댐퍼의 선정으로 댐퍼의 품질 개선을 유도하여 제연시스템의 성능을 향상시켜 신뢰성 있는 성능위주설계의 제연시스템을 구축하고자 한다. 제연댐퍼 누설량 시험을 한 결과 시험장치의 크기는 시험하는 제품의 규격, 성능에 따라 결정되므로 먼저 제품의 성능 등급을 설정하여 크기를 결정하여야 하며, 모든 시스템의 성능은 계측에 의하여 판단되므로 측정 값의 신뢰도 확보는 최우선 되어야 하며, 제연댐퍼의 시험방법에 따라 신뢰도를 부여할 수 있는 시험횟수와 시험해야 할 수량에 대하여 충분한 검토 결과에 따른 설정이 필요하다.

최적합 구름 베어링용 Urea계 그리이스의 특성평가 연구 (A Study on Characteristics of the Optimum Urea Type Grease for Rolling Bearings)

  • 김상근;박창남;한종대
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.123-129
    • /
    • 2004
  • Rolling bearings are assorted one of the most important machine elements. The various functions of bearings are greatly influenced by grease, and higher performance of rolling bearing greases is required to improve rolling bearing lubrication. The two conditions for optimum grease synthesis were selected by SSRED (Six Sigma Robust Engineering Design) program by using dropping points and OIT values respectively. And the optimized two urea/ether oil greases were synthesized to compare the performance. The typical physical properties of grease were investigated. And life test of these greases was conducted by rolling bearing grease life tester The characteristics of the greases before and after life test were investigated using FTIR, microscope, SEM, TG/DSC, OIT and TAN meter The optimized two greases showed longer life time than typical urea/ether oil grease. The optimized grease by means of OIT value showed higher performance such as long life time. low TAN value and high oil bleeding amount in comparison with the optimized grease using dropping point.

  • PDF

최적합 구름 베어링용 Urea계 그리이스의 특성평가 연구 (A Study on Characteristics of the Optimum Urea Ope Grease for Rolling Bearings)

  • 한종대;김상근;박창남
    • Tribology and Lubricants
    • /
    • 제21권1호
    • /
    • pp.21-26
    • /
    • 2005
  • Rolling bearings are assorted one of the most important machine elements. The various functions of bearings are greatly influenced by grease, and higher performance of rolling bearing greases is required to improve rolling bearing lubrication. The two conditions for optimum grease synthesis were selected by SSRED (Six Sigma Robust Engineering Design) program by using dropping points and OIT values respectively. And the optimized two urea/ether oil greases were synthesized to compare the performance. The typical physical properties of grease were investigated. And life test of these greases was conducted by rolling bearing grease life tester. The characteristics of the greases before and after life test were investigated using FTIR, microscope, SEM, TG/DSC, OIT and TAN meter. The optimized two greases showed longer life time than typical urea/ether oil grease. The optimized grease by means of OIT value showed higher performance such as long life time, low TAN value and high oil bleeding amount in comparison with the optimized grease using dropping point.

리어가이더 형상변화에 따른 횡류홴 성능해석 (Analysis of Performance of Cross-Flow Fan with Various Rear Guiders)

  • 김동원;이준환;박성관;김윤제
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2076-2082
    • /
    • 2003
  • A cross-flow fan is widely used on many industrial fields: mining industry, automobile and home appliances, etc. The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between 30% and 40% because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the lower flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow field against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for investigating the flow characteristics in a cross-flow fan including the impeller, the rearguider and the stabilizer. Especially, various types of rearguiders are estimated by numerical and experimental methods to insure the stable operation in the region of lower flow rate. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard ${\kappa}-{\varepsilon}$ turbulence model. ASHRAE standard fan tester is also used to estimate the performance of the modeled crossflow fan.

  • PDF

비재하 가열시험 및 Stub 시험체를 활용한 CFT기둥의 역학적 특성평가에 관한 실험적 연구 (An Experimental Study on the Evaluation of Mechanical Properties of CFT Column by Unstressed Test and Stub Specimen)

  • 이대희;이태규;이의배;김영선;김규용;김무한
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.209-213
    • /
    • 2008
  • Recently, it increases in use of CFT(Concrete filled steel tube, below CFT) because material and method are required to be diversification and High-Performance according to increase the super-high structure. But, CFT column lose bearing capacity under fire because steel tube is exposed to outside. As a result, structure is collapsed and then it cause much damage. In case of the Europe, Japan and America, they have studied the fire-resistance performance of CFT under fire for a long time. However, it would have hardly studied it in domestic because it is much difficulty about experiment machine and cost. So it is needed base on fire-resist performance of CFT under fire. Therefore, this study dynamic specificity of stub column which made tester of stub column based on facts of strength and mixing fiber evaluated used heating and load testing machine. As a result, it is willing to propose fundamental data for quick and accurate diagnosis of deteriorated concrete structure by fire damage with experiment according to the design high strength concrete.

  • PDF