• Title/Summary/Keyword: Performance Test Equipment

Search Result 998, Processing Time 0.028 seconds

An Experimental Study on the Characteristic of Thermal Performance according to Feed Water Conditions to of Vacuum Membrane Distillation Module using PVDF Hollow Fiber (PVDF 중공사막을 이용한 진공 막 증류 모듈의 공급수 조건에 따른 열성능 특성에 관한 실험적 연구)

  • Joo, Hongjin;Kwak, Heeyoul
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.339-346
    • /
    • 2017
  • In this study, thermal performance test of VMD module was performed, prior to the construction of the demonstration plant using the vacuum membrane distillation (VMD) module of the capacity of $400m^3/day$ and to the commercialization of the VMD module. For the thermal performance test, the experimental equipment of capacity of $2m^3/day$ was constructed. The permeate flux test and thermal performance test according to feed water conditions such as temperature and flow rate were conducted. The VMD module used in the study was manufactured by ECONITY Co., LTD with PVDF hollow fiber membrane. As a result, the Performance Ratio (PR) of the VMD module showed the maximum value of 0.904 under the condition of feed water temperature of $75^{\circ}C$ and flow rate of $8m^3/h$. PR value of the VMD module using PVDF hollow fiber membrane showed linearly increasing relationship with feed water temperature and flow rate. Also, The permeate flux of the VMD module was analyzed to have maximum value of 18.25 LMH and the salt rejection was 99.99%.

Performance improvement of serial communication converter of train control computer (열차제어컴퓨터 시리얼통신변환장치(HADAX)의 성능개선에 관한 연구)

  • Cho, Bong-Kwan
    • Journal of The Korean Society For Urban Railway
    • /
    • v.6 no.4
    • /
    • pp.427-436
    • /
    • 2018
  • HADAX is a serial communication converter of train control computer. It is connected with various signal equipments such as wayside signal equipments, station signal equipments, train control computers, and transmits control information and signal condition information for train control. And transmits information to several electronic interlocking devices through a splitter interface. Since HADAX interfaces with many signaling devices through serial communication, frequent communication connection faults necessitate improvement of performance such as dual system configuration, integration of external splitter, and multi-channelization of communication card. The improved HADAX device should have compatibility with the dimensions of existing enclosure and enclosure, and verify the performance of dual system and splitter integration. Therefore, we verified the performance of HADAX through the route control test, dual system test, and multi-channel communication test with splitter integrated connection by connecting with the existing signal equipment.

A comparative investigation of infection control perception and performance of occupational therapists before and after the outbreak of COVID-19 (COVID-19 발생 전후 작업치료사의 감염관리 인식 및 수행도 비교 조사)

  • Joo, HoYeon;Cha, Tae-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.13 no.3
    • /
    • pp.91-103
    • /
    • 2022
  • This study surveyed 101 occupational therapists who were performing occupational therapy before and after the COVID-19 outbreak to compare their perceptions and performance of hand washing, use of personal protective equipment, and infection control of surrounding environment. Mann-Whitney U test, Kruskal wallis H test, Wilcoxon signed-rank test, Pearson's correlation coefficient were used analyzed. As a result, it was confirmed that they received better infection control education after the outbreak compared to before the outbreak of COVID-19, and their experience with infectious diseases was lower. In addition, it was found that the perception and performance of infection control in hand washing, personal protective equipment, and surrounding environment cleaning were improved after the outbreak compared to before the outbreak of COVID-19. However, to this day, hand washing for more than 40 seconds in running water recommended by the Korea Centers for Disease Control and Prevention, cleaning the treatment room, and disinfection of treatment tools are still in need of improvement. Through this study, infection control education should be repeated regularly to minimize the occurrence of infectious diseases, and It will be a basic data that can be used in infection control education and follow-up studies for occupational therapists in the future.

Fracture Behavior of the Cut Surface of a Flat Panel Glass according to Vibration Input (진동 인가에 따른 평판 유리 절단면의 파괴거동)

  • Choi, Seong-Dae;Cheong, Seon-Hwan;Kim, Gi-Man;Kweon, Hyun-Kyu;Jeon, Jae-Mock;Rho, Young-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.4 no.3
    • /
    • pp.51-56
    • /
    • 2005
  • This research presents a modeling and a manufacturing method of screw flow meter. This paper introduces the efficient design and manufacturing method of screw type flow meter using reverse engineering and test technology. The methods introduced this paper utilize the reverse engineering that is increasing accuracy of modeling and manufacturing of reverse model. And then it can be used in performance test with hydraulic test equipment. Hence this can be used in the basic document for development of the quite accurate flowmeter.

  • PDF

A characteristic test of Auxiliary power supply for High Speed Rolling stock 350 experimental (HSR-350x) (한국형고속열차 보조전원장치 특성시험)

  • Jeong, Sang-Hun;Kim, Dong-Hwan;Lee, Byung-Song;Lee, Tae-Hyung
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.185-191
    • /
    • 2006
  • Auxiliary power supply developed by domestic technology has very important function that not only effect on main power converter & inverter system, traction motor and train control system which are related to performance of train, but also influence on power supply for HVAC(Heat, Ventilation, Air-conditioning) and lighting device which are related to comfort of passengers. This paper shows characteristic test results of auxiliary power supply such as working condition and performance, which is associated with velocity of train, operating mode and surrounding equipment, through test running. Also it shows the results deduced from comparison analysis between designed data and manufactory test data as measuring in put voltage of auxiliary power supply. And, it propose a modification of design parameter for stabilizing operation and improving reliability.

  • PDF

Comparison of the Earthquake Test Procedures for the Network Equipments (통신장비의 내진안전성 시험평가절차 비교)

  • Kim, Young-Joong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.887-890
    • /
    • 2005
  • The earthquake test Procedures specified in three international codes were reviewed and compared for the network equipments. As technical level on the electronics and networking is growing in Korea, many related equipments are required to export to abroad. The network equipments are now essential tools for communication among individuals as well as societies, especially at the hazard situation such as earthquake strike. The Korean network companies are trying to improve the earthquake resistance performance for their products to expand domestic and international markets. In this paper it is reviewed that most codes related on the earthquake tests can be performed with the facilities provided in Korea for the network equipments. However new facility is required to prepare for more performance and higher regulating codes expected.

  • PDF

Evaluation of high performance isolation spring mount by attached masses (부가질량 효과에 따른 고효율 방진마운트의 진동저감 성능평가)

  • Ho, Kyoung-Chan;Lee, Byoung-Chul;Lee, Yong-Hyun;Lee, Young-Je;Kim, Min-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1247-1252
    • /
    • 2007
  • The machine equipment of the building inside occurs the vibration. In order to reduce this vibration spring, rubber pad is used. But efficiency of this classical mount is restricted at specific frequency. Also maximum efficiency design is complicated. This paper proposes and examines a attached mass isolation system that is used to reduce transmitted vibrations from machines onto their floor support. With attached mass the low frequency performance is improved overall. The performance is showed in 2 degree of freedom model test. And the proposed isolator has been validated by dynamic test and good agreement between theoretical and experimental results has been obtained.

  • PDF

Study on Hull Form Development and Resistance Performance of High Speed Aluminum Leisure Boat (30피트급 고속 알루미늄 레저보트 선형개발과 저항성능에 관한 연구)

  • Jeong, Uh-Cheul;Kim, Do-Jung;Choi, Hong-Sik
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.6
    • /
    • pp.14-18
    • /
    • 2012
  • A 30ft class aluminum leisure boat is newly developed and the resistance performances are investigated by a model test at a high-speed circulating water channel. The effect of a fin attached to the side of the hull is studied at two different displacements. Wave patterns are observed to make clear the relationship between the resistance performance and wave characteristics. It can be found that a chine position at the draft line can have a strong effect on the resistance performance around a certain velocity range.

The Construction Work Completion of the Fuel Test Loop (핵연료 노내조사시험설비 설치공사 완료)

  • Park, Kook-Nam;Lee, Chung-Young;Chi, Dae-Young;Park, Su-Ki;Shim, Bong-Sik;Ahn, Sung-Ho;Kim, Hark-Rho;Lee, Jong-Min
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.291-295
    • /
    • 2007
  • FTL(Fuel Test Loop) is a facility that confirms performance of nuclear fuel at a similar irradiation condition with that of nuclear power plant. FTL consists of In-Pile Test Section (IPS) and Out-Pile System (OPS). FTL construction work began on August, 2006 and ended on March, 2007. During Construction, ensuring the worker's safety was the top priority and installation of the FTL without hampering the integrity of the HANARO was the next one. Task Force Team was organized to do a construction systematically and the communication between members of the task force team was done through the CoP(community of Practice) notice board provided by the Institute. The installation works were done successfully overcoming the difficulties such as on the limited space, on the radiation hazard inside the reactor pool, and finally on the shortening of the shut down period of the HANARO. Without a sweet of the workers of the participating company of HEC(Hyundae Engineering Co, Ltd), HDEC(HyunDai Engineering & Construction Co. Ltd), equipment manufacturer, and the task force team, it is not possible to install the FTL facility within the planned shutdown period. The Commissioning of the FTL is on due to check the function and the performance of the equipment and the overall system as well. The FTL shall start operation with high burn up test fuels in early 2008 if the commissioning and licensing progress on schedule.

  • PDF

The study on performance test of a city railroad power facilities detection device (도시철도 전력설비 이상검출용 장치 공장시험에 대한 고찰)

  • Im, Hyeong-Gil;Ryu, Ki-Seon;Jung, Ho-Sung;Choi, Kwang-Bum;Lee, Gi-Seung
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1930-1936
    • /
    • 2010
  • Because of the environmental matters the importance of the city railroad is as time goes by increasing. The case of obstacle of the power equipment which supplies electric power to city railroad will occur social and economical enormous loss. Thus, I studied on the preventing method in advance which makes it possible for us to maintain facilities efficiently. The main check points of the power facilities are voltage, current, humidity, partial discharge, move current. These points are gathered by sensor and transmitting to data acquisition device. These data are used to check equipment status in real time. In this paper I described in brief test process and results of the detection system.

  • PDF