• Title/Summary/Keyword: Performance Test Equipment

Search Result 998, Processing Time 0.028 seconds

Voltage Measurement Accuracy Assessment System for Distribution Equipment of Smart Distribution Network

  • Cho, Jintae;Kwon, Seong-chul;Kim, Jae-Han;Won, Jong-Nam;Cho, Seong-Soo;Kim, Juyong
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1328-1334
    • /
    • 2015
  • A new system for evaluating the voltage management errors of distribution equipment is presented in this paper. The main concept of the new system is to use real distribution live-line voltage to evaluate and correct the voltage measurement data from distribution equipment. This new approach is suitable for a new Distribution Management System (DMS) which has been developed for a distribution power system due to the connection of distributed generation growth. The data from distribution equipment that is installed at distribution lines must be accurate for the performance of the DMS. The proposed system is expected to provide a solution for voltage measurement accuracy assessment for the reliable and efficient operation of the DMS. An experimental study on actual distribution equipment verifies that this voltage measurement accuracy assessment system can assess and calibrate the voltage measurement data from distribution equipment installed at the distribution line.

The Experimental Study of SPM(Selectively Permeable Membrane Materials) by using Aerosol Test Instrument (에어로졸 시험장비를 이용한 방호 의복 소재의 여과 효율에 대한 연구)

  • Kwon, Tae Geun;Seo, Hyeon Kwan;Kim, Jin Won;Kang, Jae Sung;Kang, Ki Tae;Ahn, Kang Ho;Choi, Jin Soo;Cho, Jae Ho;Kwon, Yong Taek;Park, Hyen Bae
    • Particle and aerosol research
    • /
    • v.10 no.3
    • /
    • pp.109-117
    • /
    • 2014
  • In Korea, permeable protection clothes for chemical agent is being developed and distributed. But permeable protection clothes are vulnerable for biological agent of particle type. Therefore selective permeable membranes are being developed to protect chemical agent and biological agent simultaneously. In this study, aerosol collection efficiency test was performed to validate the protection performance of permeable clothes and selective permeable membranes. Aerosol collection efficiency test was performed by using the aerosol test equipment that could test aerosol particle diameter from $0.005{\mu}m$ to $3.0{\mu}m$. This study shows the test method and performance test results for collection efficiency by using the aerosol test equipment.

The test methods of Lifting performance and Environmental resistance tests using power assist device for a fireman to rescue humans (인명구조용 소방대원 근력지원장치의 양중성능 및 내환경 시험 방법)

  • Lee, Minsu;Park, Chan;Lee, Seonmin;Lee, Dongeun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.3
    • /
    • pp.358-365
    • /
    • 2017
  • As the damage caused by disasters increases rapidly around the world, it is necessary to develop the technology for equipment to reduce human injury. Therefore in the support of fire safety and 119 rescue and rescue technology research and development project, in the "Development of a power assist device for a fireman to rescue humans(2015 ~ 2018)" for life saving restoration, we are developing equipment that satisfies the lifting performance considering the disaster environment and the disaster response scenario(Amount of load over 100 kg, height of over 1 m, height over middle 60 cm, speed over 0.2 m/s). In this study, we propose a lifting performance and environmental test method to evaluate the usefulness of the power-assisted device and analyze and verify detailed specifications of the device through dynamics analysis of the lifting performance test. This study suggests that the proposed test method can be applied practically to evaluate whether a stable performance of a power-assisted device is achieved.

A study on the development of life test equipment for eco-robot for collecting recycling products (재활용품 회수용 환경로봇 수명시험 장치 구성에 관한 연구)

  • Kang, B.S.
    • Journal of Applied Reliability
    • /
    • v.11 no.4
    • /
    • pp.357-369
    • /
    • 2011
  • Eco-robot for collecting recycling products is the machine which collects non-industrial wastes such as cans, PET bottles and etc. to reuse them as recycling resources. This eco-robot is operated in the condition that it should compress and hold various products without knowing their geometric shapes and material properties. For this reason reliability problems like malfunction or failure. comes to emerge, but the reliability test conditions to assess its performance and durability have not been founded yet. Therefore in this research failure mechanism of the eco-robot was analyzed and life test equipment which can reproduce actual usage conditions was developed. The compression levels in the life test were determined by measuring the crushing force acting on test products and Furthermore the test specimens which have equivalent shape and material properties with those of cans and PET bottles were proposed by simulating the deformation characteristics so that the actual compression conditions were set up in the test.

Flow Characteristics of Hydraulic Driven Super-Charger for Heavy Equipment (중장비용 유압구동형 수퍼차져의 유동특성)

  • Kim, B.H.;MOON, C.J.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.37-42
    • /
    • 2011
  • The purpose of this study is to investigate the actual field application of the super-charger for heavy equipment. In this paper, the numerical analysis and performance evaluating experiments were performed. ANSYS CFX program has been used to obtain the solutions for the problems of three-dimensional turbulent air flow in the super-charger. To evaluate the flow performance of the super-charger, the performance test facility and data acquisition system were manufactured. We obtained satisfactory results from CFD analysis and flow experiment.

The Optimum Selection and Drawing Output Program Development of Shell & Tube Type Oil Cooler (원통다관 형 오일냉각기의 최적선정 및 도면 출력 프로그램 개발)

  • Lee, Y.B.;Ko, J.M.;Kim, T.S.
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2609-2614
    • /
    • 2007
  • Shell & Tube type Oil Cooler is widely used for hydraulic presses, die casting machines, generation equipments, machine tools and construction heavy machinery. Temperature of oil in the hydraulic system changes viscosity and thickness of oil film. They have a bad effect to performance and lubrication of hydraulic machinery, so it is important to know exactly the heat exchanging efficiency of oil cooler for controlling oil temperature. But most Korean manufacturers do not have test equipment for oil cooler, so they cannot carry out the efficiency test of oil cooler and it is impossible to verify its performance. This paper includes information of construction of necessary utilities for oil cooler test and design and manufacture of test equipment. One can select the optimum product by obtaining performance data through tests of various kinds of oil coolers. And also the paper developed a program which can be easily used for design of 2D and 3D drawings of oil cooler.

  • PDF

Presentation of Performance Test Criteria for Denuclearization Verification Equipment Considering North Korea Environment (북한 환경을 고려한 비핵화 검증 장비의 성능 시험 기준 제시)

  • Ji-Young, Han;Su-Hui, Park;Yong-Min, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.71-77
    • /
    • 2023
  • The issue of North Korea's denuclearization is an global issue that transcends the North and South. It is necessary to prepare for the denuclearization process in preparation for the situation in which North Korea reveals its intention to denuclearize. In the process of North Korea's denuclearization, it is required to guarantee the normal operation of the denuclearization verification equipment. If a performance test criteria that takes into account the North Korean environment is established, it is highly likely that it will be used in the future denuclearization process. For this purpose, basic materials related to performance test standards were established through analysis of test standards such as international standards. After that, we established a performance test criteria. This includes high temperature, low temperature, humidity, vibration and shock tests. Through follow-up studies, validity of test criteria will be established through actual device testing.

Nursing Students' Awareness and Performance on Standard Precautions of Infection Control in the Hospital (간호대학생의 병원감염관리 표준주의에 대한 인지도와 수행도)

  • Hong, Sun-Yung;Kwon, Young-Sook;Park, Hee-Ok
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.18 no.2
    • /
    • pp.293-302
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate nursing students' awareness and performance on standard precautions and to provide meaningful information for nursing students' education regarding hospital infection control. Method: Four hundred forty seven nursing students at 6 universities in D-city participated in this study. Data collection was conducted from March to April 2011. Students' awareness and performance on standard precautions of infection control in hospitals were measured using the modified 2007 CDC standard precautions guidelines. Data analysis was performed using the SPSS WIN 18.0 program, descriptive statistics, t-test, and ANOVA. Results: The level of students' awareness in the standard precautions was higher than performance. The higher levels of students' awareness and performance on standard precautions included patient care equipment, safe injection practices, and worker safety. The lower levels of students' awareness and performance on standard precautions included hand hygiene and personal protective equipment. There was no difference in the students' awareness and performance of standard precautions according to their characteristics. Conclusions: Based on the findings of this study, hand hygiene and personal protective equipment need to be stressed more within the program to improve nursing students' infection control techniques.

Factors associated with performance of infection control among some physical therapists

  • Seol, Yoon-Yee;Han, Mi Ah;Park, Jong;Ryu, So Yeon
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.2
    • /
    • pp.155-163
    • /
    • 2016
  • Purpose: Infection management is important for physical therapists in order to protect patients and themselves since they often provide patient care and have physical contact with patients. This study examined the performance of infection control and associated factors among physical therapists. Methods: The study subjects were 174 physical therapists working in the G metropolitan city. The performance of infection control according to general characteristics, job-related characteristics, and infection-related characteristics were compared using t-test and ANOVA. Associations between awareness and performance of infection control were tested by correlation. Finally, multiple linear regression analyses were performed to examine the factors associated with performance of infection control. Results: Overall performance scores for personal and therapy room were $87.47{\pm}11.70$ and $70.08{\pm}13.68$, respectively. Both personal and therapy room infection control were lower for the degree of performance than the degree of awareness. In multiple linear regression analysis, the degree of performance at a personal level was related to current smoking status, type of charge therapy, supply of protection equipment, and awareness of personal infection control. The degree of performance of therapy room was related to injury experience in the workplace, supply of protection equipment, and awareness of therapy room infection control. Conclusion: Performance of therapy room infection control was lower than that of personal infection control. The performance was associated with the supply of protection equipment and awareness. Therefore, the degree of performance for infection control will be increased with proper supply of protection equipment in the hospital and increase the degree of awareness with adequate prevention education.

Tasks for Development of Autogenous Pressurization System and Construction of Test Equipment (자가증기 가압시스템 개발과제 및 모사시험설비 구성)

  • Cheulwoong Kim;Jisung Yoo;Sangyeon Ji;Jae Sung Park
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.27 no.1
    • /
    • pp.49-57
    • /
    • 2023
  • The autogenous pressurization has been widely adopted for propulsion systems of next-generation reusable rockets due to its low cost and high reliability. The autogenous pressurization has a simple structure, but an understanding of the heat and mass transfer occurring inside the tank is essential. For this reason, a simulation test of the autogenous pressurization was conceived. The experiment equipment was constructed based on overseas pressurization test facilities cases and expert advice. Unlike the actual autogenous pressurization system, the propellant tank was insulated to exclude external influences. The pressurized gas supply line and the propellant pipe were separated. Using the manufactured autogenous pressure experiment equipment, it is possible to evaluate the condensation phenomenon of pressurants in cryogenic propellants, comparison of the efficiency of pressurization using helium and evaporated gas and the pressurization capacity according to the temperature of pressurant.