• Title/Summary/Keyword: Performance Recovery

Search Result 2,196, Processing Time 0.035 seconds

Recovery Methods in Main Memory DBMS

  • Kim, Jeong-Joon;Kang, Jeong-Jin;Lee, Ki-Young
    • International journal of advanced smart convergence
    • /
    • v.1 no.2
    • /
    • pp.26-29
    • /
    • 2012
  • Recently, to efficiently support the real-time requirements of RTLS( Real Time Location System) services, interest in the main memory DBMS is rising. In the main memory DBMS, because all data can be lost when the system failure happens, the recovery method is very important for the stability of the database. Especially, disk I/O in executing the log and the checkpoint becomes the bottleneck of letting down the total system performance. Therefore, it is urgently necessary to research about the recovery method to reduce disk I/O in the main memory DBMS. Therefore, In this paper, we analyzed existing log techniques and check point techniques and existing main memory DBMSs' recovery techniques for recovery techniques research for main memory DBMS.

TQM Factors and Their Impact on Service Recovery and Service Performance - In restaurant settings - (TQM 특성이 서비스 회복 및 서비스 성과에 미치는 영향 - 외식산업을 중심으로 -)

  • Suk, Jong Bae;Chung, Soong Hwan;Choi, Kanghwa
    • Journal of Korean Society for Quality Management
    • /
    • v.41 no.1
    • /
    • pp.95-108
    • /
    • 2013
  • Purpose: The purpose of this study is to identify the impact of TQM dimensions through service recovery justice on service quality and customer satisfaction. Methods: This study employed structural equation modeling methodology analyzing 265 samples collected. Results: This study found that TQM related factors had positive influence on service recovery justice in general. In specific, top management leadership and employee participation are the most important factors for the service recovery justice. Conclusion: This study reveals that service recovery justice has the positive impact on both service quality and customer satisfaction.

Light Source Target Detection Algorithm for Vision-based UAV Recovery

  • Won, Dae-Yeon;Tahk, Min-Jea;Roh, Eun-Jung;Shin, Sung-Sik
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.9 no.2
    • /
    • pp.114-120
    • /
    • 2008
  • In the vision-based recovery phase, a terminal guidance for the blended-wing UAV requires visual information of high accuracy. This paper presents the light source target design and detection algorithm for vision-based UAV recovery. We propose a recovery target design with red and green LEDs. This frame provides the relative position between the target and the UAV. The target detection algorithm includes HSV-based segmentation, morphology, and blob processing. These techniques are employed to give efficient detection results in day and night net recovery operations. The performance of the proposed target design and detection algorithm are evaluated through ground-based experiments.

A Study on Operating Method by Energy Evaluation and Performance Evaluation of Heat Recovery Ventilator According to Outdoor Conditions (전열교환 환기시스템의 외기변화에 따른 성능평가 및 에너지평가를 통한 운전방안에 관한 연구)

  • Kim, Kwang-Hyun;Yee, Jurng-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.1
    • /
    • pp.57-64
    • /
    • 2008
  • Recently, regulation of ventilator installation and its details has been revised and the establishment of heat recovery ventilator in newly built apartments has been obligated. This study was done to offer the method of operation and design of heat recovery ventilator to save energy by measuring its efficiency and comparing with the results of experiment. This paper confirmed that it is desirable to operate heat recovery ventilator by using "by-pass mode" within $60{\sim}80%$ scope of the difference indoor absolute humidity in spring and autumn and outdoor absolute humidity and heat recovery ventilator of energy saving effect is better than constant air volume system.

Hybrid Data Recovery Technique of RAID Level 5 Architecture (RAID 레벨 5 구조의 혼합형 데이타 복구 기법)

  • Jeon, Sang-Hoon;Ahn, Byung-Chul
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.27 no.7
    • /
    • pp.675-683
    • /
    • 2000
  • For real time services of multimedia applications, storage systems should provide data without degrading their performance. Since it is very important to recover data immediately at a disk failure, the disk recovery system is required. This paper presents a hybrid recovery scheme which prevents degraded the performance on a single disk failure at RAID level 5 architecture until the failed disk is replaced with a new disk. The proposed scheme is very economical compared to previous spare disk schemes because it does not use extra disks. The performance of the proposed scheme is evaluated and analyzed with that of the RAID level 5 for various requested sizes through the simulation. The results show that the performance of the proposed scheme is improved up to 20 percents at the failure mode and 80 percents at the reconfigured mode. After a multimedia server system has been built with a RAID controller and hard disks, the data recovery performance of the propose scheme are compared with the results of simulation.

  • PDF

Study on Performance Prediction and Energy Saving of Indirect Evaporative Cooling System (간접식 증발냉각장치의 성능예측과 에너지절약에 관한 연구)

  • Yoo, Seong Yeon;Kim, Tae Ho;Kim, Myung Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.9
    • /
    • pp.743-749
    • /
    • 2015
  • The purpose of this study is to predict the performance of an indirect evaporative cooling system, and to evaluate its energy saving effect when applied to the exhaust heat recovery system of an air-handling unit. We derive the performance correlation of the indirect evaporative cooling system using a plastic heat exchanger based on experimental data obtained in various conditions. We predict the variations in the performance of the system for various return and outdoor air conditioning systems using the obtained correlation. We also analyze the energy saving of the system realized by the exhaust heat recovery using the typical meteorological data for several cities in Korea. The average utilization rate of the sensible cooling system for the exhaust heat recovery is 44.3% during summer, while that of the evaporative cooling system is 96.7%. The energy saving of the evaporative cooling system is much higher compared to the sensible cooling system, and was about 3.89 times the value obtained in Seoul.

The Performance of a Simultaneous Heat and Cooling Heat Pump at Various Charging Conditions (동시냉난방 히트펌프의 냉매 충전량과 운전모드 변화에 따른 성능특성에 관한 연구)

  • Song, In-Sik;Choi, Jong-Min;Joo, Young-Ju;Chung, Hyun-Joon;Kang, Hoon;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.492-499
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

Delta-Operator-Based Digital Redesign of Linear Time-Invariant Systems

  • Lee, Ho-Jae;Park, Jin-Bae;Lee, Yeun-Woo;Joo, Young-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.942-944
    • /
    • 2004
  • This paper proposes a delta-operator-based digital redesign (DR) technique. An asymptotic property of the delta-operator-based DR is analyzed. The performance recovery is proved as a sampling time approaches zero.

  • PDF

Design of burst receiver with symbol timing and carrier synchronization (심벌동기와 반송파동기를 가진 버스트 수신기의 설계)

  • 남옥우
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.44-48
    • /
    • 2001
  • In this paper we describe the design of symbol timing and carrier synchronization algorithms for burst receiver. The demodulator consists of digital down converter, matched filter and synchronization circuits. For symbol timing recovery we use modified Gardner algorithm. And we use decision directed method for carrier phase recovery. For the sake of performance analysis, we compare simulation results with the board implemented by FPGA which is APEX20KE series chip for Alter. The performance results show it works quite well up to the condition that a frequency offset equal to 0.1% of symbol rate.

  • PDF

Performance of Heat Recovery System using Evaporative Cooling (증발냉각을 이용한 배기열 회수장치의 성능에 관한 연구)

  • Yoo, Seong Yeon;Kim, Tae Ho;Kim, Myung Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Evaporative cooling is a very effective way for exhaust heat recovery that uses both latent heat and sensible heat. This study investigated the performance of a heat recovery system using evaporative cooling. The experimental apparatus comprised a plastic heat exchanger, a water spray nozzle, an air blowing fan, a water circulation pump, and measuring sensors for the temperature, humidity, and flow rate. The effectiveness of the sensible heat recovery without evaporation was measured and compared with that of the total heat recovery with evaporation. The effectiveness of the sensible and total heat recoveries decreased as the air flow rate increased, and a much higher effectiveness was obtained with the counterflow arrangement in both cases. For total heat recovery, the effectiveness increased with the water flow rate, and the parallel flow arrangement was found to be more sensitive to the water flow rate than the counterflow arrangement.