• Title/Summary/Keyword: Performance Rate

Search Result 16,811, Processing Time 0.04 seconds

The Optimal Composing the Filter-Bed for Coping with Daily Flow-Rate Fluctuation for the Performance of Sand Filtration Process (일유량 변동에 따른 여과수질 악화에 대처하기 위한 최적 여재구성에 관한 연구)

  • Park, Dong-Hak;Park, No-Suk;Kim, Seong-Su;Bae, Cheol-Ho;Jung, Nahm-Chung;Cjoi, Seung-II
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.485-491
    • /
    • 2007
  • The fluctuation of inlet flow to a water treatment plant makes a serious problem that it can change the filtration rate abruptly, and ultimately occur the breakthrough of the detained particles inside filter media. Also, since it takes very short time (about 10 minutes) for the surface wave occurred from the fluctuation of inlet flow to reach the filtration process, it is impossible to control the filtration rate stably. Therefore, this study was conducted to evaluate the effect of daily flow-rate fluctuation on the performance of sand filtration process, and to suggest the dual media composition for coping with that effect. Comparative column tests have been carried out for various dual media (sand and anthracite) compositions. From the results of column tests, dual media, especially in the case of sand 45cm/anthracite 30cm, is more effective to cope with the effect of flow-rate fluctuation on the performance of filtration than single media (only sand). In addition, irrespective of dual media composition, managing ability to cope with that fluctuation tends to be weak at the end of allowable filtration duration time,

Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Type Ground Source Heat Pump with a Variation of Compressor Speed and Water Flow Rate (용량 가변 및 유량변화에 따른 지열원 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성)

  • Cho, Chan-Yong;Choi, Jong-Min
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.30-36
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWTs of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system was optimized at higher refrigerant charge amount conditions.

A Study on the Performance Improvement of Uplink in Multi-rate Mobile Communication System Using Adaptive Parallel Interference Canceller (적응 PIC를 이용한 다중전송률 이동통신시스템의 상향채널 성능 개선 연구)

  • 안정근;진용옥
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.230-236
    • /
    • 2002
  • A study on architecture of new parallel interference canceller which can be applied for reverse link of next generation mobile communication system supporting multi-rate is performed on this paper. The proposed method adopts new algorithm which can be applied for multi-rate system to reduce multiple access interference (MAI) which cause performance degradation of CDMA system and limit of channel capacity. The proposed system is evaluated by simulation results under various conditions. As a result, performance enhancement is achieved compared to existing conventional interference cancellers. Although the amount of calculation is increased, we can find that the performance is improved generally.

MXTM-CFAR Processor and Its Performance Analysis (MXTM-CFAR 처리기와 그 성능분석)

  • 김재곤;김응태;송익호;김형명
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.7
    • /
    • pp.719-729
    • /
    • 1992
  • An improved MXTM (maximum trimmed mean) -CFAR (constant false alarm rate) processor is proposed to reduce false alarm rates In detecting radar targets and Its performance character is ticsare analyzed to be compared with those of other CFAR processors. The proposed MXTM-CFAR processor is obtained by combining the GO (greatest of ) -CFAR processor reducing excessive falsealarm rate at riutter edges with the TM-CFAR processor showing good performances In homo-geneous Jnonhornog eneous background. Performance analyses have been done by computing detection probability, constant false alarm rate and detection thresholds under the homogeneous or multiple target environments and at the clutter edges. Analysis results how that the proposed CFAR processor maintains its performance as good as those of,05(order statistics) and TM-CFAR inhomogeneous and multiple target environments and Can reduce the false alarm rate at clutter edges. Overall computing time hfs been also reduced.

  • PDF

Double TR Prefilter for High Data Rate and Minimum ISI in Multi-user Indoor Communication System (다중 사용자 실내 통신 시스템에서의 데이터 고속 전송 및 심볼 간 간섭 최소화를 위한 이중 시역전 전처리 필터)

  • Yoon, Mi-Sun;Lee, Chung-Yong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.8
    • /
    • pp.58-64
    • /
    • 2012
  • We propose a double time reversal (TR) prefilter for high data rate and minimum interference in multi-user indoor communication system. A conventional TR prefilter degrades bit error rate (BER) performance significantly because it cannot remove the interference perfectly. As the symbol duration is close, the BER performance is deteriorated. Since the proposed scheme aims to minimize interference, high data rate is realized without the performance degradation and the complexity of receiver is reduced through an additional prefilter design. Simulation results show that the performance of the proposed scheme is improved as the number of users is increased or the data rate becomes high.

Rejection Scheme of Nearest Neighbor Classifier for Diagnosis of Rotating Machine Fault (회전 기계 고장 진단을 위한 최근접 이웃 분류기의 기각 전략)

  • Choe, Yeong-Il;Park, Gwang-Ho;Gi, Chang-Du
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.3
    • /
    • pp.52-58
    • /
    • 2002
  • The purpose of condition monitoring and fault diagnosis is to detect faults occurring in machinery in order to improve the level of safety in plants and reduce operational and maintenance costs. The recognition performance is important not only to gain a high recognition rate bur a1so to minimize the diagnosis failures error rate by using off effective rejection module. We examined the problem of performance evaluation for the rejection scheme considering the accuracy of individual c1asses in order to increase the recognition performance. We use the Smith's method among the previous studies related to rejection method. Nearest neighbor classifier is used for classifying the machine conditions from the vibration signals. The experiment results for the performance evaluation of rejection show the modified optimum rejection method is superior to others.

A Modified Product Code Over ℤ4 in Steganography with Large Embedding Rate

  • Zhang, Lingyu;Chen, Deyuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.7
    • /
    • pp.3353-3370
    • /
    • 2016
  • The way of combination of Product Perfect Codes (PPCs) is based on the theory of short codes constructing long codes. PPCs have larger embedding rate than Hamming codes by expending embedding columns in a coding block, and they have been proven to enhance the performance of the F5 steganographic method. In this paper, the proposed modified product codes called MPCs are introduced as an efficient way to embed more data than PPCs by increasing 2r2-1-r2 embedding columns. Unlike PPC, the generation of the check matrix H in MPC is random, and it is different from PPC. In addition a simple solving way of the linear algebraic equations is applied to figure out the problem of expending embedding columns or compensating cases. Furthermore, the MPCs over ℤ4 have been proposed to further enhance not only the performance but also the computation speed which reaches O(n1+σ). Finally, the proposed ℤ4-MPC intends to maximize the embedding rate with maintaining less distortion , and the performance surpasses the existing improved product perfect codes. The performance of large embedding rate should have the significance in the high-capacity of covert communication.

Treatment Study of the Turbid Water by High-Speed Synthetic Fiber Filter System (합성섬유 여재를 충진한 고속여과장치에 의한 탁수처리에 관한 연구)

  • Park, Kisoo;Cheng, Jing;Kim, Youngchul
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.3
    • /
    • pp.262-271
    • /
    • 2015
  • Laboratory study was undertaken to pursue the filter performance of a micro-filter module employing highly porous fiber media under a high filtration rate (over 1,500 m/day), faster than that of any conventional filter process. The effects of filtration rate, head loss, raw water turbidity, and filter aid chemicals on filter performance were analyzed. In spite of the extremely high filtration rate, the filter achieved an attractive efficiency, reducing the raw water turbidity by over 80%. As with other filter systems, the filter aid used (PAC in this study) greatly affected the performance of this particular fiber filter. Long term repetitive runs were additionally carried out to confirm the reproducibility of the filter performance. Finally, a comparison was carried out with other high rate filter systems which are either being tested for use in experimental studies, or are already commercially available.

The Study of Flow Rate Performance and Engine Application with LPG Composition Rate for LPi Fuel Supplying System Consisted of Turbine Type Pump (터빈방식 연료펌프로 구성된 LPi 연료공급 시스템의 LPG 조성비에 따른 토출성능 및 엔진적용성에 관한 연구)

  • Lim, Mu-Chang;Myung, Cha-Lee;Park, Sim-Soo;Park, Jeong-Nam;Kim, Sung-Kun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.99-105
    • /
    • 2007
  • Currently, BLDC fuel pump was applied on LPi vehicle using 3rd fuel supply system as liquified phase LPG injection method had already shown better performance than others. Its cost, however, is rather expensive because of drawbacks such as complicated structure, a fault of localization of system. In this work, demonstration system for a developed turbine type fuel pump to replace BLDC system was setup and investigated. This study results that fuel mass flow rate of turbine type pump and injection performance of injector were better compared to BLDC type. Comparing flow rate of summer LPG with that of winter LPG, the flow rate decreased about 25% using winter LPG. Performance applying turbine type LPi fuel pump to engine is confirmed.

Effects of Baffle Location on the Performance of a Super Compact Condenser in an Automotive Air Conditioning System (자동차용 에어컨의 고밀도 응축기(SCC)에서 배플의 위치 변화에 따른 성능향상에 관한 연구)

  • 이명재;박복춘;백병준;염동석;한창섭
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.6
    • /
    • pp.128-140
    • /
    • 1997
  • A new super compact condenser(SCC), which has been developed recently is especially suitable for an alternative refrigerant HFC-134a due to its high performance and compactness. The SCC is composed of two pipe headers, baffles, narrow multi-rectangular channels, and louvered fin arrays. Alternating inlet and outlet by the inserted baffles in pipe headers guide refrigerant to and from the narrow multi-rectangular channels. Since the flow rate and its lengh are changed depending on the number and location of baffles, the corresponding pressure drop and heat transfer rate are changed. The present study aims to theoretically and experimentally investigate the effects of baffle location and its number on the pressure drop and thermal performance of the SCC with 40 multi-rectangular channels. The results show that the present method provides an acceptable prediction of pressure drop and heat transfer rate for a 4 pass SCC. However, the model significantly under predicts the performance of a 3 pass SCC, which may be attributed to the phase separation of refrigerant flowing through header pipes. Pressure drop is more signifi- cantly influenced than heat transfer rate by the baffle location.

  • PDF