• Title/Summary/Keyword: Performance Diagnostic Program

Search Result 61, Processing Time 0.024 seconds

A Study on GUI type On-line Condition Monitoring Program for A Turboprop Engine Using LabVIEW$^{(R)}$ (LabVIEW를 이용한 터보프롭 엔진의 GUI기반 온라인 상태감시 프로그램에 관한 연구)

  • Kong, Chang-Duk;Kim, Keon-Woo;Kim, Ji-Hyun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.3
    • /
    • pp.86-93
    • /
    • 2011
  • Recently, development and application of condition monitoring and diagnostic system for improvement of durability and reliability and reduction of operating cost is generalized in the aircraft propulsion system. Expecially, for reliable operation of the high altitude and a long time and condition monitoring system to identify faults and degradations of its propulsion system should be needed. This work proposed a GUI-based On-line condition monitoring program using LabVIEW by PT6A-67 turboprop engine. The proposed on-line condition program can monitor the real engine performance as well as the trend through precise comparison between performance results calculated by the base performance simulation program and measuring engine performance signals. In the development phase of this monitoring system, a signal generation module is proposed to evaluate the proposed on-line monitoring system.

A Study on Automotive Diagnostic System using CAN, CAN FD, FlexRay (CAN, CAN FD, FlexRay를 이용한 자동차용 진단시스템에 관한 연구)

  • Son, Chang-Koan;Oh, Se-Chun;Kim, Eui-Ryong;Kim, Sin-Ryeong;Kim, Young-Gon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.6
    • /
    • pp.311-318
    • /
    • 2016
  • Recent vehicles are using car internal network for various purposes such as vehicle control, diagnostic functions, and ECU program upgrade. Currently CAN and FlexRay are the most representative networks. In the next-generation network, the use of CAN FD and car ethernet is actively studied. In this paper, we aimed to compare and evaluate the diagnostic function and the program of the ECU from the upgrade view on characteristics related to download time for each network when CAN, CAN FD, and FlexRay network are applied. As a result of the simulation, it was possible to determine that the CAN FD network is currently the most suitable for the next-generation network by suppressing other networks in terms of cost performance even under conditions of 500 Kbps and 2 Mbps which are practically usable speeds.

GUI Environmental Controller Design with USB IF (USB IF를 이용한 GUI환경의 제어기 개발)

  • Sun-Hag Hong
    • Journal of the Korea Computer Industry Society
    • /
    • v.4 no.4
    • /
    • pp.449-454
    • /
    • 2003
  • In this paper, GU environmental controller is implemented with USB(Universal serial bus) IF(interface). Especially, the performance examination of ultrasound diagnostic device which connects external USB port with front panel is automatically inspected by VC++ examination program. The test program minimizes the operation of inspector with making the examined result audible or visible, and maximizes the productivity of custom device. The GUI environmental controller controls a standard keyboard, a track ball with dedicated buttons to emulate a standard two-button mouse, switches, rotary encoders, an analog potentiometer group, two alpha-numeric displays. and a touch screen; all of which generate events for the host.

  • PDF

A Design Approach to Concurrent Self-Diagnosable Microprocessor (동시자기진단이 적용한 마이크로푸로세서의 하드웨어 구성에 관한연구)

  • 하경재;신명철
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.1
    • /
    • pp.68-77
    • /
    • 1989
  • In this paper, a design approch is presented for a concurrent self-diagnosable microprocessor. An efficient diagnostic procedure to dynamically test the processor functional units decomposed by each insturction, concurrently with a program under execution is suggested. The basic goals of the proposed design approach are the low hardware overhead, no increase in the pin count and the minimal change of the initial design concepts on conventional microprocessors. The results of the performance of the suggested self-diagnosing hardware for an 8080 type microprocessor show that the suggested diagnosis scheme would be efficiently applicable, since diagnosing the processor functional units can be completed in a reasonably short time with the execution of an arbitrarily chosen sample program.

  • PDF

A Study on Intelligent Performance Diagnostics of a Gas Turbine Engine Using Neural Networks (신경회로망을 이용한 가스터빈 엔진의 지능형 성능진단에 관한 연구)

  • Kong, Chang-Duk;Kho, Seong-Hee;Ki, Ja-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.3
    • /
    • pp.51-57
    • /
    • 2004
  • An intelligent performance diagnostic computer program of a gas turbine using the NN(Neural Network) was developed. Recently on-condition performance monitoring of major gas path components using the GPA(Gas Path Analysis) method has been performed in analyzing of engine faults. However because the types and severities of engine faults are various and complex, it is not easy that all fault conditions of the engine would be monitored only by the GPA approach Therefore in order to solve this problem, application of using the NNs for learning and diagnosis would be required. Among then, a BPN (Back Propagation Neural Network) with one hidden layer, which can use an updating learning rate, was proposed for diagnostics of PT6A-62 turboprop engine in this work.

Diagnostic Performance of Combined Single Photon Emission Computed Tomographic Scintimammography and Ultrasonography Based on Computer-Aided Diagnosis for Breast Cancer (유방 SPECT 및 초음파 컴퓨터진단시스템 결합의 유방암 진단성능)

  • Hwang, Kyung-Hoon;Lee, Jun-Gu;Kim, Jong-Hyo;Lee, Hyung-Ji;Om, Kyong-Sik;Lee, Byeong-Il;Choi, Duck-Joo;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.201-208
    • /
    • 2007
  • Purpose: We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). Materials and methods: We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors). The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Results: Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve = 0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve =0.860), but there was no statistical differerence in sensitivity, specificity and accuracy between the combined method and a single modality. Conclusion: It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer.

Common positioning errors in panoramic radiography: A review

  • Rondon, Rafael Henrique Nunes;Pereira, Yamba Carla Lara;do Nascimento, Glauce Crivelaro
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

A Sampling Strategy for Estimating Infection Rate in Vector Mosquitoes of Mosquito-borne Bovine Viral Diseases (소 모기매개 바이러스성 질병의 Vector 감염률 추정을 위한 표본추출 전략)

  • Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.63-67
    • /
    • 2012
  • Mosquitoes are the vectors of a number of viral diseases in cattle, such as Akabane disease, bovine ephemeral fever, Ainovirus infection, Chuzan virus infection, and Ibaraki disease. These diseases are transmitted from an infected animal to a non-infected host via the blood feeding of the vector. In Korea, the National Veterinary Research and Quarantine Services, Ministry for Food, Agriculture, Forestry and Fisheries is responsible for planning, implementation, laboratory investigations and reporting the results of the national surveillance program for mosquito-borne bovine diseases (MBD). The surveillance program, which was started in 1993, focused to determine the seroprevalence of each disease in cattle herds in space and time. From the epidemiological point of view, more important component of the surveillance program is to monitor infection rates in vectors for specific pathogens because this information is essential for a more precise understanding the dynamics of these diseases in a given environment and for determining risk of transmission. The aim of this study was to describe and compare methods for estimation of vector infection rates using maximum likelihood (MLE) and minimum infection rate in pooled samples. Factors affecting MLE such as number of pools, pooling size and diagnostic test performance are also discussed, assuming some hypothetical sampling scenarios for MBD.

Optical Coherence Tomography Applications for Dental Diagnostic Imaging: Prototype System Performance and Preclinical Trial

  • Eun Seo Choi;Won-Jin Yi;Chang-Seok Kim;Woosub Song;Byeong-il Lee
    • Current Optics and Photonics
    • /
    • v.7 no.3
    • /
    • pp.283-296
    • /
    • 2023
  • An intraoral spectral domain optical coherence tomography (SD-OCT) system has been developed, using a custom-built hand-held scanner and spectrometer. The hand-held OCT probe, based on a microelectromechanical systems scanner and a self-built miniaturized drive circuit, had a field of view sufficient for dental diagnosis. The spectrometer using a fabricated f-theta lens provided the image depth required for dental diagnosis. The axial and transverse resolutions of the OCT system in air were 7.5 ㎛ and 12 ㎛ respectively. The hand-held probe could scan an area of 10 × 10 mm2, and the spectrometer could image along a depth of 2.5 mm. To verify the utility of the developed OCT system, OCT images of tooth hard and soft tissues were acquired, and a user-interface program for diagnosis was developed. Early caries and microcracks that were difficult to diagnose with existing methods could be found, and the state of restoration could be observed. Measuring the depth of the gingival sulcus, distinguishing subgingival calculus, and detecting an implant under the gingiva suggested the possibility of the SD-OCT system as a diagnostic for dental soft tissues. Through the presented OCT images, the capability of the developed SD-OCT system for dental diagnosis was demonstrated.

Development of In-House Multiplex Real Time PCR for Human Papillomavirus Genotyping in Iranian Women with Cervical Cancer and Cervical Intraepithelial Neoplasia

  • Sohrabi, Amir;Mirab-Samiee, Siamak;Modarressi, Mohammad Hossein;Izadimood, Narge;Azadmanesh, Kayhan;Rahnamaye-Farzami, Marjan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6257-6261
    • /
    • 2014
  • Background: HPV related cervical cancer as one of the most common women cancers in developing countries. Regarding accessibility of commercial vaccines, any long or short term modality for integrating preventive immunization against HPV in a national program needs comprehensive information about HPV prevalence and its genotypes. The important role of selecting most accurate diagnostic technologies for obtaining relevant data is underlined by different assays proposed in the literature. The main objective of the present study was to introduce an in-house HPV typing assay using multiplex real time PCR with reliable results and affordable cost for molecular epidemiology surveys and diagnosis. MATERIALS AND METHODS: 112 samples of formalin fixed paraffin embedded tissues and liquid based cytology specimens from patients with known different grades of cervical dysplasia and invasive cancer, were examined by this method and the result were verified by WHO HPV LabNet proficiency program in 2013. RESULTS: HPV was detected in 105 (93.7%) out of 112 samples. The dominant types were HPV 18 (61.6%) and HPV 16 (42.9%). Among the mixed genotypes, HPV 16 and 18 in combination were seen in 12.4% of specimens. CONCLUSIONS: According to acceptable performance, easy access to primers, probes and other consumables, affordable cost per test, this method can be used as a diagnostic assay in molecular laboratories and for further planning of cervical carcinoma prevention programs.