• 제목/요약/키워드: Perforated Tube

검색결과 68건 처리시간 0.022초

선천성 낭포성 유선종 기형 (Congenital Cystic Adenomatoid Malformation(CCAM))

  • 김수원
    • Journal of Chest Surgery
    • /
    • 제21권6호
    • /
    • pp.1084-1094
    • /
    • 1988
  • Conservative management of 3 iatrogenic perforations of intrathoracic esophagus was reviewed. The primary disorders were achalasia in 2 patients and congenital tracheoesophageal fistula in 1 patient. Perforation occurred after treatment of the primary disorders in the distal esophagus in 2 patients and mid-thoracic esophagus in 1 patient. All the perforations appeared late after the previous treatments and the inflammation spread to mediastinum and pleural cavity in all the 3 patients. Conservative management of esophageal perforation was carried out with intraluminal drainage from the perforated site of esophagus[insertion of Levin`s tube and continuous suction], pleural drainage and feeding of liquid diet through gastrostomy tube with Fowler`s position. The patients revealed spontaneous closure of perforated sites about 3 to 4 weeks after this conservative management without open thoracotomy. This result suggests that this conservative management may be accepted as therapeutic method in the thoracic esophageal perforations regardless of cause and time of the perforation.

  • PDF

배기 소음기 구조가 삽입손실에 미치는 영향 (The Effect of Insertion Loss on the Element of Exhaust Muffler)

  • 강동림;김영호;전현부기;김의간
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권5호
    • /
    • pp.42-51
    • /
    • 2000
  • The performances of the simple expansion, perforated tube, and conical-connector type as an exhaust muffler are shown in this study. Applying a model in which the method of four-pole parameter is used makes theoretical estimation of the insertion loss. Experiment is performed for the measurement of the insertion loss under four cases according to the variation of the tail pipe length. By comparing the theoretical prediction with the experimental results, the validity of the modeling using the method of four-pole parameter is verified. The personal computer simulation programs for the above mentioned theory on the muffler design have been developed and exhaust sound level measurements have been carried out for simple expansion muffler, conical-connector muffler, perforated tube mufflers and the combined type of conical-connector and simple expansion muffler. The measured results for attenuation characteristics of noise for each muffler are compared with the computed theoretical results to verity the confidence and applicable limits of the theoretical equation derived.

  • PDF

다공관 출구로부터 방사된 충격성 소음의 전파특성 (Propagation Characteristics of the Impulse Noise Emitted from the Exit of a Perforated Pipe)

  • 제현수;양수영;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.168-173
    • /
    • 2003
  • This experimental study describes the propagation characteristics of the impulse noise emitted from the exit of a perforated pipe attached to the open end of a simple shock tube. The pressure amplitudes and directivities of the impulse wave propagating from the exit of perforated pipe with several different configurations are measured and analyzed fur the range of the incident shock wave Mach number between 1.02 and 1.2. In the experiments, the impulse waves are visualized by a Schlieren optical system for the purpose of investigating their propagation pattern. The results obtained show that for the near sound field the impulse noise strongly propagates toward to the pipe axis, but for the far sound field the impulse noise uniformly propagates toward to the all directions, indicating that the directivity pattern is almost same regardless of the pipe type. Moreover, it is shown that for the far sound field the perforated pipe has little performance to suppress the impulse noise.

  • PDF

병렬 다공판 시스템의 흡음성능에 관한 연구 (A Study on the Sound Absorbing Performance of Parallel Perforated Plate Systems)

  • Hur, Sung-Chun;Im, Jung-Bin;Lee, Dong-Hoon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.388.2-388
    • /
    • 2002
  • An equivalent electroacoustic circuit approach of estimating the sound absorption coefficient for parallel perforated plate system is proposed. The proposed approach is validated by comparing the calculated absorption coefficients of a parallel single layer perforated plate system with the values measured by the two-microphone impedance tube method for various porosity and cavity depth. (omitted)

  • PDF

Analysis of non-uniformly perforated muffler in concentric resonator type

  • Delaigue Antoine;Ih Jeong-Guon;Guyader Jean L.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2001년도 추계학술발표대회 논문집 제20권 2호
    • /
    • pp.379-382
    • /
    • 2001
  • In the muffler industry, the main purpose of the research works is to determine a way to increase the TL (Transmission Loss) properties of the muffler, without deteriorating the back pressure influence. In order to obtain better results, several works have been done by changing the geometrical characteristics of the muffler or the type of the muffler. This work will focus on the perforated muffler components with concentric chamber, to investigate the effect of a non-uniform porosity along the inner perforated tube of the muffler on the TL. It is noted that varying the perforation ratio affects the peaks frequencies of the TL, especially fer $2\pi < kL < 4\pi$ (in the case of L : 200mm for the concentric resonator). The magnitudes of the TL, for this range of frequencies, vary noticeably by changing the porosity distribution.

  • PDF

알루미늄칩과 타공판을 이용한 방음벽 충진재의 흡음특성 (Absorption Characteristics of Sound Proof Wall by Scrap Aluminum and Perforated Plate)

  • 이영중;김대건;박경화;김영도
    • 한국재료학회지
    • /
    • 제19권7호
    • /
    • pp.382-385
    • /
    • 2009
  • Efforts to reduce noise in industrial application fields, such as automobiles, aircrafts, and plants have been gaining considerable attention while a sound proof wall to protect people from the noise has been intensively investigated by many researchers. In this study, our research group suggested creating a new sound proof wall composed of scrap aluminum chips and perforated plates in a commercial polyester sound proof wall, which was then successfully fabricated. This wall's sound absorption characteristics were measured by an impedance tube method. The sound absorption property was evaluated by measuring the Noise Reduction Coefficient (NRC) to the standard, ASTM C 423-90a. The noise reduction coefficient of the sound proof wall composed of 3.5 vol.% and 7.5 vol.% of scrap aluminum chips relatively increased to 5% and 8% compared to the commercial polyester sound proof wall. The scrap aluminum perforated plate also relatively increased to 13% compared to the commercial polyester sound proof wall.

Floated Wafer Motion Modeling of Clean Tube system

  • Shin, Dong-Hun;Yun, Chung-Yong;Jeong, Kyoo-Sik;Choi, Chul-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1264-1268
    • /
    • 2004
  • This paper presents a wafer motion modeling of the transfer unit and the control unit in the clean tube system, which was developed as a means for transferring the air-floated wafers inside the closed tube filled with the super clean airs. The motion in the transfer unit is modeled as a mass-spring-damper system where the recovering force by air jets issued from the perforated plate is modeled as a linear spring. The motion in the control unit is also modeled as another mass-spring-damper system, but in two dimensional systems. Experiments with a clean tube system built for 12-inch wafers show the validity of the presented force and motion models.

  • PDF

클린 튜브 시스템 이송 유닛의 웨이퍼 운동 역학 모델링 (Wafer Motion Modeling of Transfer Unit in Clean Tube System)

  • 신동헌;정규식;윤정용
    • 한국정밀공학회지
    • /
    • 제21권3호
    • /
    • pp.66-73
    • /
    • 2004
  • This paper presents wafer motion modeling of transfer unit in clean tube system, which was developed as a means for transferring the air-floated wafers inside the closed tube filled with the super clean airs. When the wafer is transferred in x direction with an initial velocity the motion along x direction can be modeled as a simple decaying motion due to viscous friction of the fluid. But, the motion in y direction is modeled as a mass-spring-damper system where the recovering force by air jets issued from the perforated is modeled as a linear spring. Experiments with a clean tube system built fur 12 wafer show the validity of the presented force and motion models.

원통형 임피던스 튜브 내 다중 미세천공 판의 음향투과 (Sound transmission of multi-layered micro-perforated plates in a cylindrical impedance tube)

  • 김현실;마평식;김봉기;이성현;서윤호
    • 한국음향학회지
    • /
    • 제39권4호
    • /
    • pp.270-278
    • /
    • 2020
  • 본 논문은 원통형 임피던스 튜브내에 설치된 다중 미세천공판(Micro-Perforated Plate, MPP)의 음향투과를 해석적으로 구하는 방법을 다루었다. 판의 진동을 무한 급수의 합으로 전개하였는데 반경방향으로는 Bessel 함수를 포함한다. 평면파 가정하에서 저주파수 대역의 근사식을 유도하였으며 전달함수법을 이용하여 다중 MPP에 대한 음향투과율 공식을 제시하였다. 단일과 이중 MPP의 음향투과손실(Sound Transmission Loss, STL)을 본 논문에서 제안한 공식을 이용하여 계산하였으며 유한요소법(Finite Element Method, FEM)을 사용한 결과와 잘 일치 하였다. 천공율이 증가할수록 STL은 감소하는데 이는 판의 진동보다는 천공율이 더 큰 영향을 주기 때문이다. STL은 판의 공진주파수에서 골(dip)을 보이며 이중 MPP의 STL은 질량-스프링-질량 진동에 해당하는 공진주파수에서 골을 보인다. 본 연구에서 제안한 STL 예측 모델은 임의의 개수의 다중 MPP에 적용이 가능하며 각각의 판은 미세천공을 포함하거나 포함하지 않는 두 가지 경우가 모두 가능하다.