• Title/Summary/Keyword: Perfluorocarbons

Search Result 12, Processing Time 0.026 seconds

Determination of Atmospheric Perfluorocarbon Background Concentrations of fL/L Range at the Western Coastal Area of Korea

  • Kim, Hye-Kyeong;Yea, Sun-Kyung;Ro, Chul-Un;Lee, Chong-Bum;Jang, Meong-Do;Lee, Gang-Woong;Yoo, Eun-Jin;Han, Jin-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.2
    • /
    • pp.301-308
    • /
    • 2002
  • As part of perfluorocarbon (PFC) tracer release experiment conducted at the western coastal area of Korea in February 2001, the background concentration level of perfluorocarbons (PFCs) in the atmosphere was determined by gas chromatography with electron capture detector. Prior to the PFC tracer release experiment in the field, air samples were collected using active samplers and the background concentrations of PFCs were determined. The concentrations of perfluoromethylcyclohexane ($C_7F_{14}$, PMCH) in the western coastal area of Korea were in the range of 5.8-8.7 fL/L. The mean concentration of the PMCH in the region exhibited no significant spatial and temporal variations. This concentration level is somewhat higher and has larger standard deviation than those of studies previously conducted in USA and Europe on the background concentration levels of PFCs. Because the background concentration of PMCH in Korea is still very low and consistent temporally and spatially, the PMCH tracer can be used suitably for the studies of long-range atmospheric transport.

Separation and Recovery of F-gases (불화 온실 가스 저감 및 분리회수 기술의 연구개발 동향)

  • Nam, Seung-Eun;Park, Ahrumi;Park, You-In
    • Membrane Journal
    • /
    • v.23 no.3
    • /
    • pp.189-203
    • /
    • 2013
  • F-gases, gases containing fluorine such as perfluorocarbons (PFCs), sulfurhexafluoride ($SF_6$), nitrogen trifluoride ($NF_3$) are known to have green house effects. Although the net emission rates of gases containing fluorine are much lower than those of $CO_2$, their contribution to global warming cannot be ignored because of their extremely high global warming potential (GWP). F-gases mainly have been used for a variaty of applications in the semiconductor/LCD processes and in the electric power distribution industry of the national key industry. One of practical solutions of controlling the emission rates of F-gases is to reuse by separation and recovery of F-gases of low concentration from the gases mixtures with nitrogen or air. This work investigates some methods for F-gases recovery and separation around the membrane-based process.

A study on the emission of fluorine-based chemicals and the detection of perfluorooctane sulfonic acids(PFOS) and perfluorooctanoic acids(PFOA) in domestic main rivers (국내 불소계 화학물질 배출 현황 및 주요 수계의 과불화화합물(PFOS, PFOA) 검출 특성에 관한 연구)

  • Sam-Bae Park;Yoon-Young Chang
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.2
    • /
    • pp.5-18
    • /
    • 2023
  • As a result of the survey on the emission status of fluorine-based chemicals in Korea, 13 kinds of substances, including hydrogen fluoride (91%) and perfluorocarbons (5%), were emitted in workplaces. By regional groups, about 98% was emitted in the Gyeongbuk, Gyeonggi and Chungcheong regions, and about 98% in three sectors of industry related to manufacture of electronic parts, chemicals and non-metallic mineral products. The detection status of PFOS and PFOA in domestic main rivers was continuously detected in the Nakdong River, the Geum River and the Anseong Stream estuary with high fluorine-related chemical emissions, and four sites of PFOS and two sites of PFOA were detected for the first time in 2021. PFOS and PFOA were continuously detected in relatively high concentrations in the rivers where there were many semiconductor and display related sectors of industry.

Characteristics of a Bioreactor Using Perfluorocarbons and a New Impeller (과불소탄소화물과 새로운 임펠러를 사용한 생물반응기의 특성)

  • 조무환;김용락정재학김정목
    • KSBB Journal
    • /
    • v.6 no.3
    • /
    • pp.231-240
    • /
    • 1991
  • Recently, developments of large scale and high density cell culture methods have been the objects of many researches, because the demand of various pharmaceutical products produced by animal cell culture has been rapidly increasing. The cell culture equipment should have the requirements such as sufficient oxygen transfer and mixing, low shear stress and surface tension, and small foaming. In order to develop a proper bioreactor meeting these requirements simultaneously, a perfluorocarbon having high solubility of oxygen was sprayed into the medium as an oxygen carrier instead of air. Also, a new impeller was developed and combined together with the perfluorocarbon spraying system so as to design a new bioreartor for cell cultivation. The new impeller had better characteristics of mixing and oxygen transfer than the paddle and cell-lift impellers based on the same, shear rate. But, it was observed that the volumetric oxygen transfer coefficient of the new bioreactor decreased with increasing cell density during E. coli fermentation.

  • PDF

Improvement of Migration Fastness of Perfluorocarbons-free Synthetic Suede by Chitosan Pretreatment (키토산 전처리를 통한 과불화탄소 무함유 합성 스웨이드의 이염성 견뢰도 향상)

  • Lee, Hye Mi;Kim, Ah Rong;Kim, Dae Geun
    • Textile Coloration and Finishing
    • /
    • v.31 no.4
    • /
    • pp.258-267
    • /
    • 2019
  • Synthetic suede without PFCs(perfluorinated compounds) are followed by subsequent high temperature treatment. But migration fastness of synthetic suede may be reduced due to sublimation of disperse dyes that results from the high temperature treatment. Therefore, in this study, chitosan treatment was used to improve the migration fastness before polyurethane dipping process. Polyester fiber was treated with sodium hydroxide aqueous solution before chitosan processing. This samples treated with a chitosan concentration upto 0.5% were dyed and coated with PUD(polyurethane dispersion). The migration fastness was most improved at 0.35% application. This is presumably due to the fact that the chitosan may increase the dye-binding capability through intermolecular hydrogen bonding.

The Investigation of CF4 Decomposition in Methane Premixed Flames on Oxygen Enrichment (산소부화된 메탄 예혼합 화염에서 CF4 분해에 대한 연구)

  • Lee, Ki Yong
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.4
    • /
    • pp.51-56
    • /
    • 2017
  • The decomposition of tetrafluoromethane has been investigated with the reaction mechanism proposed for freely propagating $CH_4/CF_4/O_2/N_2$ premixed flames on the oxygen enrichment. The factors affecting on the removal efficiency of tetrafluoromethane were analyzed. The increase in flame temperature due to oxygen enrichment has a great influence on the removal efficiency of tetrafluoromethane. At the same oxygen enrichment condition, the removal efficiency in the rich flame is higher than one in the lean flame. The increase of the F/H ratio leads to decrease the flame temperature and the removal efficiency of tetrafluoromethan is decreased at the flame temperature of 2600 K or lower, The elementary reactions that dominate the consumption of tetrafluoromethane are (R1) $CF_4+M=CF_3+F+M$ and (R2) $CF_4+H=CF_3+HF$. (R1) has the greatest effect on the consumption of tetrafluoromethane under the oxygen enhanced flames.

Development of a Plasma Waterjet Scrubber for the Reduction of PFCs (과불화탄소 제거를 위한 플라즈마 워터젯 스크러버 개발)

  • Lee, Chae-Hong;Chun, Young-Nam
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.6
    • /
    • pp.624-632
    • /
    • 2010
  • Perfluorocarbons (PFCs) are widely used in semiconductor industry. These gases need to be removed efficiently because of their strong absorption of infrared radiation and long atmospheric lifetimes which cause the global warming effect. To destruct $CF_4$, a waterjet gliding arc plasma was designed and manufactured. The highest $CF_4$ destruction showed at waterjet plasma case, compared to plasma discharge only or water scrubber only, respectively. In addition, it could be known that the $CF_4$ destruction should be associated with the electron and OH radicals. The operating conditions such as waterjet flow rate, initial $CF_4$ concentration, total gas flow rate, specific energy input were investigated experimentally using a plasma waterjet scrubber. Through the parametric studies, the highest $CF_4$ destruction of 94.5% was achieved at 0.2% $CF_4$, 2.1 kJ/L SEI, 20 L/min total gas flow rate and 18.5 mL/min waterjet flow rate.

Density Functional Theory (DFT) Calculations for the Geometry, Energy, and Chemical Reaction Properties of $C_4F_8$

  • Choe, Hui-Cheol;Park, Yeong-Chun;Lee, Yun-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.193-193
    • /
    • 2013
  • Perfluorocarbons (PFCs) have been suggested as possible replacements for $SF_6$ and the fluorocarbons used in and emitted during technological plasma treatments because PFCs have significantly low greenhouse warming potentials. Of many PFCs, c-$C_4F_8$ and 2-$C_4F_8$ attract special attention because of their high CF2 radicallevels in commercial plasma treatments. Accordingly, several experimental and theoretical studies of these $C_4F_8$ species have been conducted, although only the geometries at their stationary states and their adiabatic electron affinities (EAs) have been determined. However, this information is not sufficient for a deep understanding of all the possible fates and roles of $C_4F_8$ species and their fragments in plasma phases. Although the performance and reliability ofeach DFT functional have been examined carefully by the development team of each functional form with respect to the training and test data sets of well-known molecular systems, no PFC was included in the data sets. So a careful additional assessment of the reliability of DFT functionals for the study of PFC systems is highly required. In order to find a DFT method appropriate to PFCs, the geometry, energy, and chemical reaction properties of $C_4F_8$ were calculated and compared with reference data.

  • PDF

A Study on Greenhouse Gas Emissions Characteristics of Local Government for the Achievement of the National Reduction Goal (국가 온실가스 감축목표 달성을 위한 지자체 온실가스 배출특성 연구)

  • Park, Ji Hui;Kim, Hyung Suk;Song, Kwon Bum;Yi, Sung Ju
    • Journal of Climate Change Research
    • /
    • v.8 no.3
    • /
    • pp.247-255
    • /
    • 2017
  • In this study, GHG inventory on 17 local government between 2005 and 2014 is build up using 'GHG emission estimation guideline (2016. 2) for local government' developed and distributed by KECO. This covers all the sectors should be included in national GHG inventory, which are energy, industrial process, agriculture, AFOLU, and waste. In addition, six GHGs, carbon dioxide, metane, nitrous oxide, hydrofluorocarbons, perfluorocarbons, sulphur hexafluoride declared in Kyoto protocol are estimated to reflect utmost precision. Indirect esissions, such as electricity, heat and waste generation are separately estimated as well as direct emissions to help local government to establish substantial and implementable reduction measures of GHGs.

Tracer Experiment for the Investigation of Urban Scale Dispersion of Air Pollutants - An Improved Method for the Release and Determination of Perfluorocarbon Tracers in the Urban Atmosphere (추적자 확산 실험에 의한 서울 도심 확산 현상 연구 - 도시규모 대기확산 실험을 위한 PFCs 추적자 방출 및 분석 시스템의 개발 및 적용 연구)

  • Yoo, Eun-Jin;Lee, Chong-Bum;Ro, Chul-Un;Kim, Hye-Kyeong;Lee, Gang-Woong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.5
    • /
    • pp.547-556
    • /
    • 2007
  • The release, sampling and analytical methods have been developed and tested for perfluorocarbons (PFCs) atmospheric tracers in order to gain insight into the atmospheric transport and dispersion over the urban conditions of Seoul, Korea. Although PFCs tracer experiments provide unique opportunities to test local and urban scale of transport and dispersion, no previous experiment with PFCs has been conducted in Korea. PMCH and PDCH were chosen as targeted tracers in our study due to their extreme low ambient concentrations and great sensitivities among various PFCs. For PFCs release system, a set of micro-metering pump, electronic balance, vaporizing furnace and high speed blower was constructed for precise and accurate release of tracers. The precision of released rate by this system was estimated to be 1%. Samplings of PFCs were carried out by fabricated portable air samplers with micro pumps and rotameters into glass tubes packed with 150 mg of Carboxen-569. The uncertainty of these sampling system was maintained below 14%. PMCH and PDCH were quantified in GC/ECD with preconditioned injection system to eliminate the interference compounds using traps and subsequent catalytic conversion system prior to column separation. Three intensive field test were undertaken during the springtime of 2002 to 2004 in eastern part of Seoul. Daily background samples were collected to characterize the background levels of PMCH and PDCH prior to their release. The observed background concentrations of PMCH ranged from 3.5 to 10.1 fL/L and varied randomly in location and time in this study. Its mean and standard variation of background concentration ($6.8{\pm}1.9\;fL/L$) are higher than those ($3.2{\sim}5.8\;fL/L$) of other historic tracer studies. Identified uncertainty for background PMCH was $1.7{\sim}2.0\;fL/L$ using this analytical system. Combined relative uncertainty in determining the tracer's concentrations was estimated as 17%. However, its background concentrations and uncertainty in concentration determination were found to be low and stable enough for tracer study.