• Title/Summary/Keyword: Perfect Switch

Search Result 15, Processing Time 0.019 seconds

Design of $Ti:LiNbO_3$ Three-Waveguide Optical Switch with Outer-Waveguide Fed (바깥도파로 입사된 $Ti:LiNbO_3$ 세 도파로 광스위치의 설계 및 제작)

  • Kim, Young-Moon;Seo, Jung-Hoon;Huh, Chang-Yul;Kim, Chang-Min
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.6
    • /
    • pp.61-70
    • /
    • 1999
  • An optical switch composed of three-identical, equally-spaced $Ti:LinbO_3$ waveguides and overlaid Al electrodes of CPW structure was designed and fabricated. Patterned Ti was diffused into z-cut $LinbO_3$ substrates at $1025^{\circ}C$ for 6 hours to make a three-waveguide directional coupler. $SiO_2$ buffer layer of $1.2{\mu}m$ was grown by the PECVD to reduce the propagation loss of TM mode, and Al electrodes were built on the layer for switching the guided beam. For an incident beam of ${\lambda}=1.3{\mu}m$, almost perfect optical coupling between two outer waveguides was observed. When an electric field was applied to detune the three waveguides anti-symmetrically, the optical switching phenomenon was successfully confirmed.

  • PDF

LMI-Based Robust Controllers for DC-DC Cascade Boost Converters

  • Torres-Pinzon, Carlos Andres;Giral, Roberto;Leyva, Ramon
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.538-547
    • /
    • 2012
  • This paper presents two different robust controllers for boost converters with two stages in a cascade. The first robust controller is monovariable; that is, the duty-cycle is the same for the two switches. The monovariable controller ensures that some prescribed constraints on pole placement and control effort are met, and optimizes the load disturbance rejection, while takes into account the uncertainty in certain parameters. The first controller is then compared with a multivariable robust controller; that is, with independent duty cycles in each switch. The multivariable controller takes into account the same uncertainty, constraints and optimization function. The comparison shows that the multivariable controller performs better at the expense of a slightly more complex implementation; that is, the multivariable controller provides a better rejection of the load disturbance. The paper also describes simulations and experimental results that are in perfect agreement with theoretical derivations.

Study of Selective Cell Drop Scheme using Fuzzy Logic on TCP/IP (TCP/IP에서 퍼지 논리를 사용한 선택적 셀 제거 방식에 관한 연구)

  • 조미령;양성현;이상훈;강준길
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.1
    • /
    • pp.95-104
    • /
    • 2002
  • This paper presents some studies on the Internet TCP/IP(Transmission Control Protocol-Internet Protocol) traffic over ATM(Asynchronous Transfer Mode) UBR(Unspecified Bit Rate) and ABR(Available Bit Rate) classes of service. Fuzzy logic prediction has been used to improve the efficiency and fairness of traffic throughput. For TCP/IP over UBR, a novel fuzzy logic based cell dropping scheme is presented. This is referred to as fuzzy logic selective cell drop (FSCD). A key feature of the scheme is its ability to accept or drop a new incoming packet dynamically based on the predicted future buffer condition in the switch. This is achieved by using fuzzy logic prediction for the production of a drop factor. Packet dropping decision is then based on this drop factor and a predefined threshold value. Simulation results show that the proposed scheme significantly improves TCP/IP efficiency and fairness. To study TCP/IP over ABR, we applied the fuzzy logic ABR service buffer management scheme from our previous work to both approximate and exact fair rate computation ER(Explicit cell Rate) switch algorithms. We then compared the performance of the fuzzy logic control with conventional schemes. Simulation results show that on zero TCP packet loss, the fuzzy logic control scheme achieves maximum efficiency and perfect fairness with a smaller buffer size. When mixed with VBR traffic, the fuzzy logic control scheme achieves higher efficiency with lower cell loss.

  • PDF

Implementations of Hypercube Networks based on TCP/IP for PC Clusters (PC 클러스터를 위한 TCP/IP 기반 하이퍼큐브 네트워크 구현)

  • Lee, Hyung-Bong;Hong, Joon-Pyo;Kim, Young-Tae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.2
    • /
    • pp.221-233
    • /
    • 2008
  • In general, we use a Parallel processing computer manufactured specially for the purpose of parallel processing to do high performance computings. But we can depoly and use a PC cluster composed of several common PCs instead of the very expensive parallel processing computer. A common way to get a PC cluster is to adopt the star topology network connected by a switch hub. But in this paper, we grope efficient implementations of hypercube networks based on TCP/IP to connect 8 PCs directly for more useful parallel processing environment, and make evaluations on functionality and efficiency of them using ping, netperf, MPICH. The two proposed methods of implementation are IP configuration based on link and IP configuration based on node. The results of comparison between them show that there is not obvious difference in performance but the latter is more efficient in simplicity of routing table. For verification of functionality, we compare the parallel processing results of an application in them with the same in a star network based PC cluster. These results also show that the proposed hypercube networks support a perfect parallel processing environment respectively.

  • PDF

Fundamental Studies for the Automatic Control System in the Greenhouse Using Microcomputer(II) -A Development of a Controller for an Automatic Control System- (마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(II) -자동화 시스템의 종합제어기 개발-)

  • 김진현;김철수
    • Journal of Biosystems Engineering
    • /
    • v.20 no.1
    • /
    • pp.73-86
    • /
    • 1995
  • The automatic control system in the greenhouse have to be developed to the direction of considering various factors the variables such as condition of the cultivation and greenhouse, the properties and types of products. Therefore, it is more important to set up variables appropriately than the problems of automatic control system itself, and the automatic control system which satisfy these problems should be simplified in the aspect of operation. In addition, even the individual automations are not perfect yet, so more studies are required for the development of comprehensive automatic system in korea. This study was carried out to automatize environment control systems for greenhouse, especially from most intensive labor requiring parts such as watering, irrigating liquefied fertilizer, spraying chemicals, mixing and ventilation system, etc. The results are summarized as follows. 1. Control type tensiometer was expected to be desirable in the automation of watering system, therefore, a new tensiometer was designed and developed through this study. 2. The chemical spraying system developed through this study was found to be excellent in the aspect of operation. 3. When pulse type water discharge meter was used in the mixing of liquefied fertilizer and chemical solution, the error of mixing were range $\pm$0.1~0.15%. 4. The water level switch of electrod type used for controlling water level was found to be affective in both control performance and operation cost. 5. The water and level control system can be omitted if each tank size are standardized in accordance with greenhouse size, therefore, the installation cost might be significantly reduced. 6. The developed general controller was excellent in hardware parts, but still remained to be improved in software parts.

  • PDF