• Title/Summary/Keyword: Perfect

Search Result 2,753, Processing Time 0.027 seconds

Image of Perfect Gentlemen in Fashion (의상에 나타난 Perfect Gentlemen의 이미지 연구 - 19세기 영국을 중심으로 -)

  • 이의정;양숙희
    • The Research Journal of the Costume Culture
    • /
    • v.8 no.3
    • /
    • pp.411-421
    • /
    • 2000
  • Black froak coat, white shirts, top hat and cane has been the symbol of gentlemen in 19th and early of 20th century. The pattern invented by Savile Row in London prevailed whole England. Such a pattern has been the standard form for two hundred years all over the word, although it was replaced with a functionalism which developed in Italy and America at the end of 20th century. The clothes of gentlemen was developed by several factors ; English people respect a tradition. The clothes was practical, since the weather in England was bad. The success of Industrial Revolution made England wealthy. Various special clothes in sports, for example, riding, criket, golf and tennis also contribute the modern gentlemen clothes with advance tailoring technique. The change of gentlemenship with social environment, from Regency dandy, Romantic gentlemen to Muscular Christianity, was studied. Idial gentlemenship and development its clothes which is now the standard of modern men's wear also studied.

  • PDF

Effects of Slip for Interface on Behavior and Capacity in Hybrid Structure (합성구조체의 경계면 슬립이 거동과 성능에 미치는 영향)

  • 정연주;정광회;김병석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.385-390
    • /
    • 2001
  • This paper presents a nonlinear analysis technique with slip, the effects of slip modulus and composite action by shear connector on behavior and capacity in composite structure of sandwich system. As a results of this study, it proved that the slip modulus, in case of shear behavior, seldom influence load-resistance capacity such as yield and ultimate load, but in case of flexural behavior, it appropriately influence load-resistance capacity because of stress redistribution by slip. In case of flexural behavior, analysis result for perfect-composite results in over-estimation and perfect-slip results in under-estimation on behavior and capacity. Therefore, it is desirable to model steel-concrete interface with partial-composite. The effects of slip on behavior and capacity are less in case of positive composite than loosely composite, and it proved that composite action by shear connector improve the load-resistance capacity of this system.

  • PDF

Transmission Electron Microscopy Study of Stacking Fault Pyramids Formed in Multiple Oxygen Implanted Silicon-on-Insulator Material

  • Park, Ju-Cheol;Lee, June-Dong;Krause, Steve J.
    • Applied Microscopy
    • /
    • v.42 no.3
    • /
    • pp.151-157
    • /
    • 2012
  • The microstructure of various shapes of stacking fault pyramids (SFPs) formed in multiple implant/anneal Separation by Implanted Oxygen (SIMOX) material were investigated by plan-view and cross-sectional transmission electron microscopy. In the multiple implant/anneal SIMOX, the defects in the top silicon layer are confined at the interface of the buried oxide layer at a density of ${\sim}10^6\;cm^{-2}$. The dominant defects are perfect and imperfect SFPs. The perfect SFPs were formed by the expansion and interaction of four dissociated dislocations on the {111} pyramidal planes. The imperfect SFPs show various shapes of SFPs, including I-, L-, and Y-shapes. The shape of imperfect SFPs may depend on the number of dissociated dislocations bounded to the top of the pyramid and the interaction of Shockley partial dislocations at each edge of {111} pyramidal planes.

Target Adaptive Guidance Using Near-Zone Information from IR Seeker (근접영역에서의 IR 탐색기 정보를 이용한 표적적응유도)

  • 엄태윤;김필성
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.113-119
    • /
    • 2002
  • A target adaptive guidance(TAG) algorithm is proposed employing the near-zone signal that can be measured from an infrared seeker. The guidance order is composed of a conventional PNG command and an additional command to be calculable from an additional LOS rate between a hot point of target and a required intercept point. The characteristic of the near-zone signal is similar to that of LOS rate that is inversely proportional to the square of time-to-go. Hence the proposed scheme can be applied to real systems with no estimator for time-to-go. From analysis results on the miss distance with perfect missile and perfect seeker, it follows that the proposed TAG algorithm guarantees missile to be ideally guided to the required intercept point. And it is less affected by the TAG start time and a proportional navigation ratio than other TAG schemes using a LOS rate such as a step bias or a ramp bias.

Bayesian Change-point Model for ARCH

  • Nam, Seung-Min;Kim, Ju-Won;Cho, Sin-Sup
    • Communications for Statistical Applications and Methods
    • /
    • v.13 no.3
    • /
    • pp.491-501
    • /
    • 2006
  • We consider a multiple change point model with autoregressive conditional heteroscedasticity (ARCH). The model assumes that all or the part of the parameters in the ARCH equation change over time. The occurrence of the change points is modelled as the discrete time Markov process with unknown transition probabilities. The model is estimated by Markov chain Monte Carlo methods based on the approach of Chib (1998). Simulation is performed using a variant of perfect sampling algorithm to achieve the accuracy and efficiency. We apply the proposed model to the simulated data for verifying the usefulness of the model.

A Study on the Characteristics of the Imperfect Maintenance Models (불완전 보전모형의 특성에 관한 연구)

  • Yi, Jin-Shik;Lyu, Jeong-Mo
    • IE interfaces
    • /
    • v.14 no.3
    • /
    • pp.272-285
    • /
    • 2001
  • Proper maintenance techniques have been emphasized in recent years due to increased safety and reliability requirements of systems, increased complexity, and rising costs of material and labor. In the related literature, most studies assume that the system after cm or pm is 'as good as new'(perfect maintenance) or 'as bad as old'(minimal maintenance). But many maintenance activities may not result in these two extreme situations but in a complicated intermediate one. Therefore, perfect maintenance and minimal maintenance are not practical in many actual instances and so realistic imperfect maintenance should be modeled. For this study, various imperfect preventive maintenance models are investigated and analyzed. From the analysis of the imperfect maintenance models modeling methods and maintenance policies are arranged and presented some tables providing informations to the maintenance managers.

  • PDF

Image Reconstruction Using 2D M-ch Perfect Reconstruction Filter Bank with Optimized Adaptive interpolation kernel (최적 적응 보간 커널 기반 2차원 M-채널 완전 복원 Filter Bank를 이용한 이미지 재구성)

  • Kim, Jin-Young;Nam, Sang-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.4
    • /
    • pp.795-798
    • /
    • 2007
  • In this paper, we propose an image reconstruction method utilizing an optimized adaptive interpolation kernel along with a 2D M-channel perfect reconstruction filter bank (M-ch PR-FB) structure. In particular, the proposed approach leads to construction of a sharper image than a direct conversion, still preserving high frequency components of the original image through the subband processing of the 2D M-ch PR-FB. Finally, the image quality of the proposed approach is demonstrated by comparing with those of the direct methods using conventional interpolation kernels.

GORENSTEIN-INJECTORS, GORENSTEIN-FLATORS

  • Gu, Qinqin;Zhu, Xiaosheng;Zhou, Wenping
    • Journal of the Korean Mathematical Society
    • /
    • v.47 no.4
    • /
    • pp.691-704
    • /
    • 2010
  • Over a ring R, let $P_R$ be a finitely generated projective right R-module. Then we define the G-injector (G-projector) if $P_R$ preservers Gorenstein injective modules (Gorenstein projective modules), the Gflator if $P_R$ preservers Gorenstein flat modules. G-injector (G-flator) and G-injector are characterized focus primarily on the cases where R is a Gorenstein ring, and under this condition we also study the relations between the injector (projector, flator) and the G-injector (G-projector, G-flator). Over any ring we also give the characteristics of G-injector (G-flator) by the Gorenstein injective (Gorenstein flat) dimensions of modules.

PSEUDO PROJECTIVE RICCI SYMMETRIC SPACETIMES

  • De, Uday Chand;Majhi, Pradip;Mallick, Sahanous
    • Communications of the Korean Mathematical Society
    • /
    • v.33 no.2
    • /
    • pp.571-580
    • /
    • 2018
  • The object of the present paper is to prove the non-existence of pseudo projective Ricci symmetric spacetimes $(PW\;RS)_4$ with different types of energy momentum tensor. We also discuss whether a fluid $(PW\;RS)_4$ spacetime with the basic vector field as the velocity vector field of the fluid can admit heat flux. Next we consider perfect fluid and dust fluid $(PW\;RS)_4$ spacetimes respectively. Finally we construct an example of a $(PW\;RS)_4$ spacetime.

Highly Sensitive PNA Array Platform Technology for Single Nucleotide Mismatch Discrimination

  • Choi, Jae-Jin;Jang, Min-Jeong;Kim, Ji-Hyun;Park, Hee-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.2
    • /
    • pp.287-293
    • /
    • 2010
  • Reliable discrimination of a single nucleotide mismatch was demonstrated using arrays with peptide nucleic acid (PNA) probes. The newly developed PNA probes immobilization method and hybridization conditions for PNA arrays gave excellent specificity and sensitivity. In addition we compared the specificity, sensitivity, and stability obtained with the PNA and DNA arrays in discriminating single nucleotide mismatches. The PNA arrays had superior perfect match-to-mismatch signal ratios and sensitivities. The relative signal intensities of mismatch PNA probes ranged from 1.6% to 12.1% of the perfect-match PNA probes. These results demonstrated that the PNA arrays were 2.0 to 37.3 times more specific and about 10 times more sensitive than DNA arrays. The PNA array showed the same specificity and sensitivity after 12-month storage at room temperature.