• 제목/요약/키워드: Percent flicker

검색결과 5건 처리시간 0.017초

3상 교류전원 LED 램프의 광 플리커 (Light Flicker of Three-Phase AC-powered LED Lamp)

  • 이동원;김병철
    • 한국전기전자재료학회논문지
    • /
    • 제27권4호
    • /
    • pp.262-267
    • /
    • 2014
  • This study describes that light flicker of LED lamp is improved by placing an AC-powered LED block in each phase of three-phase AC power. Rectified current is considered as an instantaneous luminous flux because the current flowing through the LED block is proportional to the amount of light emitted by the LED block. Percent flicker is calculated simply by modeling the rectified current flowing through the LED block to a triangular wave current. Percent flicker is 100% in single-phase AC powered LED lamp. Percent flicker of the same level as that in an incandescent lamp (6%~14%) is however, achieved if light emission starts before $40^{\circ}$ in each voltage phase of three-phase AC power.

국내 LED 조명등에서 플리커 현상에 관한 연구 (A Study on the Condition of LED Lights Flicker)

  • 허민;고재준;김충혁
    • 한국전기전자재료학회논문지
    • /
    • 제29권11호
    • /
    • pp.729-735
    • /
    • 2016
  • It is highly important issue to use an energy efficiently for sustainable prosperity of mankind. From this point of view, using LED lighting can be a good alternative because it has a lot of advantages such as high efficiency, long life time and eco-friendly manufacturing process. That is the reason why using LED lighting has been encouraged worldwide. However, in situations that LED lighting is replacing traditional lighting quickly, the problem of the flicker of LED lighting has emerged as an important issue. Therefore, in foreign countries like US or Japan in order to ensure the reliability of LED lighting, study for flickering effects of the human body and test methods are have been actively conducted. But related research in domestic situation is an insufficient condition. In this study, a flicker characteristic was measured conventional lamps such as incandescent lamps or fluorescent lamp and 81 items of LED lightings which are distributed in domestic markets.

환기(換氣)가 불량(不良)한 실내(室內)에서의 간접흡연(間接吸煙)에 관(關)하여 (Passive Smoking in Poorly Ventilated Room Space)

  • 이정애
    • Journal of Preventive Medicine and Public Health
    • /
    • 제14권1호
    • /
    • pp.23-31
    • /
    • 1981
  • This study was conducted to investigate the effects of passive inhalation of cigarette smoke and the correlation between change of flicker value and active or passive smoking in poorly ventilated room. Forty five male students were tested by divided into four experimental groups composed of active and passive smokers and three control groups. Each four experimental groups were exposed to smoke for Two hours in enclosed room. Vital capacities, flicker values, blood carboxyhemoglobin levels and carbon monoxide concentration in room air were estimated before, during and after the exposure, and amounts of smoking or smoke exposure during two hours were also noted. The results obtained were as follows; 1. Concentration of carbon monoxide in air and increase of blood carboxyhemoglobin level (% COHb) were positively correlated with smoking amount. 2. Increase of blood carboxyhemoglobin in passive smokeres, in average, were about seventy six percent of that in smokers, as 2.2% vs. 2.9%. 3. Comparison with published data showed that Peterson's equation gave most similar result to this study in estimation of increase of blood carboxyhemoglobin level. 4. During the exposure, flicker values fell steadily in both experimental groups and control groups as time passed. Flicker values were, however, elevated again in experimental groups after exposure, despite the fact that values still fell in control groups. 5. Blood carboxyhemoglobin and flicker value were negatively correlated and this correlationship was stronger in passive smoker than in active smoker. 6. Multiple regression equation between flicker value and exposure time and blood carboxyhemoglobin level was expressed as: Flicker value=41.6-0.2 COHb%-0.9Hour, 7. In general, it is suggested that biological criteria would be more preferrable than chemical criteria in establishment of statutory limitation of smoking in enclosed spaces.

  • PDF

낙뢰로부터 전력설비 보호를 위한 한전의 절연설계 기준 (Insulation Design Standards for Protection of Power System against Lightning in Korea Electric Power Corporation)

  • 우정욱;문재덕
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.555-560
    • /
    • 2006
  • As it has been reported that more than 60% of transmission line faults occurs due to lightning strokes, lighting is one of concerned issues in electric power utility company. Most of transmission line is double circuit in Korea. Double circuit outages account for 33.7 percent of total lightning faults from 1996 to 2004. Even though transmission fault might be cleared shortly by protective system, it could deteriorate the power quality accompanied with sag or flicker. Moreover, double circuit fault may lead to more aggravated situation, for instance, blackout. To Protect transmission lines from lightning stroke, reduction of tower footing resistance, multiple ground wires and unbalanced insulation in double circuit lines have been adopted. In this paper, we would like to introduce insulation design standards for lightning protection of Korea Electric Power Corporation.

비콘메세지를 이용한 반응형 녹색점멸 신호시스템 설계 및 구현 (Design and Implementation of Response type of Flickering Green Signal System using Beacon Message)

  • 안효인;문형진;김창근
    • 디지털융복합연구
    • /
    • 제14권11호
    • /
    • pp.241-247
    • /
    • 2016
  • 국내 교통제어신호는 주기적인 간격으로 녹색신호로 바뀌는 시스템과 차량의 수가 많지 않은 심야 또는 통행량이 적은 지방도로에서 황색, 적색 점멸신호를 사용하고 있다. 그러나 차량의 수가 많지 않은 심야의 한적한 도로에서 주기적인 신호체계를 사용할 경우 지체 및 정체를 발생하게 된다. 또한 점멸신호를 사용할 경우 충돌사고의 위험성이 크다. 본 논문은 센서 데이터를 포함한 비콘메세지를 분석한 후 신호체계를 재배치하는 반응형 녹색점멸 신호시스템을 제안한다. 제안 시스템은 심야에 간선 도로 및 하위 도로에서 신호가 녹색점멸을 유지하고 있다가 차량이 무선 커버리지 RSE내에 진입하면 비콘메세지를 주기적으로 전송하고 Agent System이 메세지를 분석해 신호를 변경한다. 차량은 변경한 신호 시스템을 따라 차량이 이동하는 시스템이며, 이는 통행량이 적은 도로에서 원활한 흐름과 차량 간 충돌 사고를 예방할 수 있다. 시뮬레이션 결과 성능 면에서 교통 처리량과 평균 대기시간이 기존 신호 시스템보다 10~30%향상되었다.