• 제목/요약/키워드: Penetration Test

검색결과 1,526건 처리시간 0.144초

Analysis of load-settlement behaviour of shallow foundations in saturated clays based on CPT and DPT tests

  • Mir, Mouna;Bouafia, Ali;Rahmani, Khaled;Aouali, Nawel
    • Geomechanics and Engineering
    • /
    • 제13권1호
    • /
    • pp.119-139
    • /
    • 2017
  • Static Penetration Test (CPT) and Dynamic Penetration Test (DPT) are commonly used in-situ tests in a routine geotechnical investigation. Besides their use for qualitative investigation (lithology, homogeneity and spatial variability), they are used as practical tools of geotechnical characterization (resistance to the penetration, soil rigidity) and modern foundation design as well. The paper aims at presenting the results of an extensive research work on the evaluation of the 1D primary consolidation settlement of saturated clayey soils on the basis of the CPT or DPT tests. The work is based on an analysis of the correlations between the tip resistance to penetration measured in these tests and the parameters of compressibility measured by the compressibility oedometer test, through a local geotechnical database in the northern Algeria. Such an analysis led to the proposal of two methods of calculation of the settlement, one based on the CPT test and the other one on the DPT. The comparison between the predicted settlements and those computed on the basis of the oedometer test showed a good agreement which demonstrate the possbility to use the CPT and DPT tests as reliable tools of computation of foundation settlements in clayey soils.

석탄가스화 용융 슬래그 치환 콘크리트의 염화이온 침투 저항성 검토 (Evaluation of Chloride Ion Penetration Resistance of Coal Gasification Slag Replaced Concrete)

  • 조현서;김민혁;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.166-167
    • /
    • 2019
  • In this study, to test the performance of concrete used as a concrete admixture as a recycling method of CGS, gypsum was mixed and the chloride ion penetration resistance test of CGS and BFS substituted concrete was conducted. As a result, it was found that without gypsum type test specimen, the CGS sustituted test specimens had lower chloride ion penetration resistance than the BFS substituted specimens. When gypsum was added, it was confirmed that the chloride ion penetration resistance was poor regardless of the type of admixture. In addition, it was confirmed that both admixtures were less resistant to chloride ion penetration than OPC, regardless of the presence of gypsum. However, considering the uneven quality variation of coal, which greatly affects the quality of CGS, further research is needed.

  • PDF

공내재하시험을 이용한 지반정수 평가 (Evaluation of Soil Properties using Pressuremeter Test)

  • 한상연;장서만;전성곤;이종규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.175-182
    • /
    • 2001
  • The PMT test results are compared with other in situ test such as Standard Penetration Test (SPT), Cone Penetration Test (CPT), Field Vane Test (FVT) and the laboratory test in order to investigate the correlationships for the strength parameters obtained from Busan and Incheon areas. Many proposed correlation formulas also make a comparative study and new correlation formulas for domestic soils are introduced. Limit pressure ( $P_1$) could be determined by P-log($\Delta$V/V) and Relative volume Method. PMT for the granular soils showed relatively high correlation with SPT, while CPT has good correlation with PMT for cohesive soil. The predicted undrained shear test ( $S_{u}$) by the PMT test results for Incheon and Busan samples showed low correlativity with proposed equations, therefore, new correlation formulas are proposed for domestic soils.s.

  • PDF

PVD처리한 티타늄 합금의 고속충격 거동에 관한 연구 (A Study on the high velocity impact behavior of titanium alloy by PVD method)

  • 손세원;이두성;홍성희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.567-572
    • /
    • 2001
  • In order to investigate the fracture behaviors(penetration modes) and resistance to penetration during ballistic impact of Titanium alloy laminates and nitrified Titanium alloy laminates which were treated by PVD(Physical Vapor Deposition) method, ballistic tests were conducted. Evaporation, sputtering, and ion plating are three kinds of PVD method. In this research, Ion plating was used to achieve higher surface hardness and surface hardness test were conducted using a Micro vicker's hardness tester. Resistance to penetration is determined by the protection ballistic limit($V_{50}$), a statistical velocity with 50% probability for complete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are respectfully observed at and above ballistic limit velocities, as a result of $V_{50}$ test and Projectile Through Plates (PTP) test methods. PTP tests were conducted with $0^{\circ}$ obliquity at room temperature using 5.56mm ball projectile. $V_{50}$ test with $0^{\circ}$ obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during PTP tests. Surface hardness, resistance to penetration, and penetration modes of Titanium alloy laminates are compared to those of nitrified Titanium alloy laminates.

  • PDF

Applicability of Mini-Cone Penetration Test Used in a Soil Box

  • Sugeun Jeong;Minseo Moon;Daehyeon Kim
    • 한국지반신소재학회논문집
    • /
    • 제22권4호
    • /
    • pp.83-92
    • /
    • 2023
  • In this study, we conducted verification of key influencing factors during cone penetration testing using the developed Mini Cone Penetration Tester (Mini-CPT), and compared the experimental results with empirical formulas to validate the equipment. The Mini-CPT was designed to measure cone penetration resistance through a Strain Gauge, and the resistance values were calibrated using a Load Cell. Moreover, the influencing factors were verified using a model ground constituted in a soil box. The primary influencing factors examined were the boundary effect of the soil box, the distance between cone penetration points, and the cone penetration speed. For the verification of these factors, the experiment was conducted with the model ground having a relative density of 63.76% in the soil box. It was observed that the sidewall effect was considerably significant, and the cone penetration resistance measured at subsequent penetration points was higher due to the influence between penetration points. However, within the speed range considered, the effect of penetration speed was almost negligible. The measured cone penetration resistance was compared with predicted values obtained from literature research, and the results were found to be similar. It is anticipated that using the developed Mini-CPT for constructing model grounds in the laboratory will lead to more accurate geotechnical property data.

제체 상태 평가를 위한 동적 콘 관입시험과 평판재하시험 결과의 상관관계 분석 (The Correlation Analysis between Dynamic Cone Penetration Test and Plate Loading Test Results for Evaluation of Dam Conditions)

  • 정영훈;김성민;임정열
    • 한국지반환경공학회 논문집
    • /
    • 제19권4호
    • /
    • pp.33-38
    • /
    • 2018
  • 제체 재료의 다짐 불량에 의한 내부 침식은 국내 제방의 주요 붕괴 원인으로, 제방의 안전진단에 있어서 제체의 다짐 상태 평가는 매우 중요한 점검 사항이다. 본 연구에서는 제체의 다짐상태 평가 시 동적 콘 관입시험의 현장 적용성을 검증하기 위해 대표적인 다짐평가 기법인 평판재하시험에 대해 상관관계를 분석하였다. 시험 부지의 지반 특성 및 토층 심도를 파악하기 위해 표준관입시험을 6회 수행하였다. 평판재하시험 15회, 동적 콘 관입시험 47회 수행 후 크리깅(Kriging) 기법으로 공간분포를 얻었다. 평판재하시험의 공간분포와 일정 관입깊이에서의 동적 콘 관입시험 공간분포 간의 피어슨 상관 계수를 계산하였다. 평판재하시험의 지지력과 관입 깊이 5cm, 10cm, 15cm에서의 동적 콘 관입시험의 타격횟수는 약한 양의 상관관계를 갖는 것으로 나타났다.

함수비를 고려한 모래의 상대밀도 추정을 위한 Fall Cone 관입량의 적용 (Application of Penetration in Fall Cone Test to Estimate Relative Density with Variation of Water Content for Sand)

  • 최우석;손영환;박재성;노수각;봉태호
    • 한국농공학회논문집
    • /
    • 제54권5호
    • /
    • pp.69-77
    • /
    • 2012
  • Relative density, used to express dynamics condition of sand quantitatively, is measured by RI Test, Standard Penetration Test and Cone Penetration Test. Each measurement method has demerits, which is complicated or needs a specific analysis instrument and an analysis of expert. Also the ground is in wet condition commonly because of an unsaturated zone between a saturated zone and a surface, so the behaviour of the ground has different engineering properties unlike the dry ground and it diminishes accuracy of measuring relative density. In this study, the correlation between relative density and penetration of fall cone test in dry condition and wet condition with variation of water content was analyzed and a simple measuring method for relative density was suggested. As a result, there were difference of penetration between dry sands and wet sands, the correlation between relative density and penetration showed linear expression and relative density could be measured by the linear relation.

모의 침투 테스트 방법 및 절차의 평가 방법에 관한 연구 (A Study on the Evaluation Method for Penetration Test Method and Procedures)

  • 강용석;최국현;신용태;김종희;김종배
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.230-233
    • /
    • 2014
  • 최근 보안 위협과 위험이 매우 빠른 속도로 변화하고 있어, 다각화 되는 공격기법에 대응하기 위한 필수 조건으로 기업 및 기관에서 모의 침투 테스트를 진행하고 있다. 침투 테스트(Penetration Test, PenTest)는 합법적이고 승인된 시도로 컴퓨터 시스템을 더 안전하게 하기 위해 시스템의 취약점을 찾아내고, 찾아낸 취약점에 대해 공격을 시도하는 것이다. 모의 해킹 테스트와 같은 용어로 사용되고 있으며 취약점이 어떻게 악용될 수 있는지 공격을 시도하여 보여준다. 한편, 현재 많은 보안업체에서 다양한 방법 및 절차로 침투 테스트를 수행하고 있으나, 실제로 이러한 테스트의 강도와 신뢰성에 대한 평가는 아직 이루어지지 않고 있다. 따라서, 본 연구에서는 이와 같은 침투 테스트에 대하여 검증되고 신뢰할 수 있는 평가 방법을 제시한다. 본 연구에서 제시한 침투 테스트 평가 정보를 활용하여 보다 신뢰할 수 있는 평가 결과를 얻을 수 있고, 결과적으로 효율적인 침투 테스트가 가능할 것으로 기대된다.

  • PDF

생태교량 적용을 위한 방수·방근공법의 Mock-up 시험 연구 (A Study on the Mock-up Test of Waterproofing/Root Penetration Resistance Technology for the Application to an Eco-bridge)

  • 선윤숙;최수영;김명지;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.230-231
    • /
    • 2014
  • This study is concerned with the root penetration resistance competence and constructability of a waterproofing and root penetration resistance layer of an eco-bridge which is applied with various types of seeding. For the review of root penetration resistance competence, the competence was tested using herbs, woody plants, and tall trees. As a result, there was no tear of or damage to the waterproofing and root penetration resistance layer as well as the sweeping-down phenomenon of a waterproofing and root penetration resistance layer by soil. Also, the effect of the root growth of herbs, woody plants, and tall trees on the root penetration resistance system was confirmed.

  • PDF

Effect of three different irrigation solutions applied by passive ultrasonic irrigation

  • Llena, Carmen;Forner, Leopoldo;Cambralla, Raquel;Lozano, Adrian
    • Restorative Dentistry and Endodontics
    • /
    • 제40권2호
    • /
    • pp.143-148
    • /
    • 2015
  • Objectives: This study evaluated the maximum depth and percentage of irrigant penetration into dentinal tubules by passive ultrasonic irrigation (PUI). Materials and Methods: Thirty extracted human teeth were instrumented and divided into three groups. According to final irrigation regimen, 5.25% sodium hypochlorite (Group A, NaOCl), 2% chlorhexidine (Group B, CHX) and saline solution (Group C, control group) were applied with Irrisafe 20 tips (Acteon) and PUI. Irrigant was mixed with 0.1% rhodamine B. Sections at 2 mm, 5 mm, and 8 mm from the apex were examined with confocal laser scanning microscopy (CLSM). The percentage and maximum depth of irrigant penetration were measured. Kruskal-Wallis test and Mann-Whitney test were performed for overall comparison between groups at each level and for pairwise comparison, respectively. Within a group, Wilcoxon test was performed among different levels. p values less than 0.05 were considered significant. Results: In all groups, highest penetration depth and percentage of penetration were observed at the 8 mm level. At 2 mm level, Groups A and B had significantly greater depths and percentages in penetration than Group C (p < 0.05), but there were no significant differences between Groups A and B. At 5 mm level, penetration depths and percentage of penetration was not significantly different among the groups. Conclusions: NaOCl and CHX applied by PUI showed similar depth and percentage of penetration at all evaluated levels.