• Title/Summary/Keyword: Penetration Reduction

Search Result 287, Processing Time 0.027 seconds

Aperture Cut-off Filter for Reduction of Electromagnetic Field Penetration through a Slot in Conducting Screens (도체평판의 슬롯 침투 전자파 저감을 위한 개구면 차단필터)

  • Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.12
    • /
    • pp.1201-1211
    • /
    • 2014
  • The purpose of this paper is to present the aperture cut-off filter for reduction of electromagnetic field penetration through a slot in conducting screen. The reduction characteristics of electric field penetration by the aperture cut-off filter are considered. In order to establish the concept of the aperture cut-off filter, the integral equation on the slot aperture field distribution is derived and solved by method of moments, and the reduction characteristics of penetration electric fields for the incident plane wave are calculated. The numerical results showed that the aperture cut-off filter for reduction of electric field penetration through the slot can be realized. To check the validity of the concept of an aperture cut-off filter and the theoretical analysis, the calculated electric field penetration of the metallic wall with narrow slot were compared with the experimental results.

A Study on the Effect of Lateral Vibration of Sheet Pile on Vibratory Driving Force (널말뚝의 횡방향진동이 진동타입력에 미치는 영향에 대한 연구)

  • Lee, Seung-Hyun;Kim, Byoung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.848-852
    • /
    • 2007
  • Many numerical analysis tools for predicting penetration speed of sheet pile are thought to be unreliable because they overestimate penetration speed for shallow depth of penetration. In order to overcome the defects of numerical analysis, lateral vibration model of sheet pile was suggested and energy consumption due to lateral vibration of sheet pile was estimated. Also, load reduction factor which explains reduction of vibratory driving force due to lateral vibration was introduced.

  • PDF

Environmental Friendly Characteristics of CRM Asphalt Concrete and Optimal Mixing Ratio (CRM 아스팔트의 최적 혼합비와 환경친화적 특성)

  • Ryu, Byeong-Ro;Han, Yang-Su
    • Journal of Environmental Science International
    • /
    • v.10 no.4
    • /
    • pp.311-314
    • /
    • 2001
  • The asphalt mixture with CRM(Crumb Rubber Modifier) is known to show a better performance in resisting thermal cracking, fatigue cracking and rutting compared with the conventional mixture. The laboratory tests on the physical characteristics of indirect tensile strength, density, flow and Marshall value of the CRM asphalt were conducted. The test results show that CRM asphalt has better physical characteristics than that of conventional asphalts. And the analysis on the noise reduction effect, penetration capacity from the field test on the national road in Haksan of Chungbuk, and recycling of tire waste were conducted. From this study, the results show that 1% CRM asphalt has higher the noise reduction effect and penetration capacity that those of conventional asphalts. And, optimal contents of crumb rubber modifier in the asphalt binder is one percent. In this case, crumb rubber modifier were used 10 kg to make the asphalt binder of one cubic meter. So it was named as Eco-asphalt.

  • PDF

Reduction Characteristics of Electromagnetic Penetration through Narrow Slots in Conducting Screen by Loading Parallel Wire Arrays

  • Kim Ki-Chai;Lim Sung-Min
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.2
    • /
    • pp.123-129
    • /
    • 2006
  • This paper presents a method of reducing penetration of penetrated electromagnetic fields through a narrow slot with parallel wire arrays in a planar conducting screen of infinite extent. An integral equation for the aperture electric field on the narrow slot is derived and solved by applying Galerkin's method of moments. When a plane wave is excited to the narrow slot, the aperture electric field is easily controlled by the parallel wire arrays connected on the slot and therefore the magnitude of the penetrated electric field is effectively reduced by loading the parallel wire arrays. The numerical results show that the magnitude of the penetrated electromagnetic field can be effectively reduced by installing the parallel wire arrays on the slot. The results of the calculated penetration electric fields are in good agreement with that of the measured results.

Reduction Effect of liquefaction by Vibro-Replacement Stone Columns (진동치환 스톤칼럼공법에 의한 액상화 저감 효과)

  • Lee, Song;Chae, Jum-Sik;Park, Sang-Kuk
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.443-450
    • /
    • 2001
  • This paper shows the reduction effect of tile earthquake-induced liquefaction potential of soils that improved by Vibro-Replacement Stone Columns. The Vibro-Replacement Stone Columns method transforms soft cohesive soils into a composite mass of compacted granular or crushed stone columns by using vibrating equipment and water jets. This study investigated and analyzed the behavior of the stone columns and composite ground using the results of in situ test and measurement at the job-site. This paper shows the evaluation of the earthquake-induced liquefaction potential of soils using in situ test. There are different types of in situ test used in the evaluation the liquefaction potential. In the particular study the Standard penetration test, and Cone penetration test were used. The N value of Standard Penetration test has been used all over for a very long time. The evaluation of the liquefaction of soil was performed using the worldwide renewed Cone penetration test

  • PDF

Reduction Characteristics of Electromagnetic Penetration through a Slit in a Conducting Screen by a Loaded Triangle Plate (삼각형 도체판 장하에 의한 무한 도체 평판 슬릿의 침투 전자파 저감 특성)

  • Cho, Byung-Ho;Lee, Seung-Ik;Kim, Hyo-Kyun;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.7
    • /
    • pp.767-773
    • /
    • 2014
  • This paper presents the reduction characteristics of electromagnetic penetration through a slit in conducting screen by loaded plate. The FDTD method is used in theoretical analysis. And the characteristics of penetrated electric fields are calculated in terms of length, width, shape, position, and height of the loaded plate to find out how the geometry of plate influences the reduction characteristics of the electromagnetic penetration and shielding effectiveness. The results show that the characteristics of penetrated electric field and shielding effectiveness depend on the geometry of loaded plate. In particular, the optimal geometry of loaded plate which minimize penetrated electric field are verified.

Reduction Characteristics of Electromagnetic Penetration through a Slot in a Conducting Screen by a Loaded Plate (도체판을 부가한 무한 도체 평판 슬롯의 침투 전자파 저감 특성)

  • Cho, Byung-Ho;Jung, Sung-Woo;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1094-1099
    • /
    • 2012
  • This paper presents the reduction characteristics of electromagnetic penetration through a slot in conducting screen by loaded plate. The FDTD method is used in theoretical analysis. And the characteristics of penetrated electric fields are calculated in terms of length, width, position, and height of the loaded plate to find out how the geometry of plate influences the reduction characteristics of the electromagnetic penetration. The results show that the characteristics of penetrated electric field depend on the geometry of loaded plate. In particular, the optimal geometry of loaded plate which minimize penetrated electric field are verified.

Spray Characteristics of a Liquid-fueled Ramjet Engine under High Pressure Air-stream Conditions

  • Lee, Choong-Won;Youn, Hyun-Jin;Lee, Tae-Hee;Lee, Geun-sun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.749-752
    • /
    • 2004
  • In a liquid-fueled ramjet engine, the insufficient mixing and evaporation result in the low combustion efficiency and combustion instability. Improving its spray characteristics and devising a means of mixing fuel droplets with air may compensate these disadvantages of liquid fuel ramjet engine. The jet penetrations of various fuel injectors were measured to investigate the spray characteristics of a liquid-fueled ramjet engine under high pressure air-stream conditions. The penetrations in high pressure conditions are smaller than the values calculated from Inamura's or Lee's equations, and, in the high pressure conditions, the jet penetrations are similar each other. In the dual hole injectors, the jet penetrations of rear orifice is rapidly increased due to the reduction of the drag, which is created by the jet column of front orifice. The jet penetration of rear orifice is increased because of the drag reduction created by the jet column of the front orifice. And, because of the drag reduction formed by the column of jet, the jet penetration in the rear orifice of dual hole injector is much larger than the jet penetration of single hole injector. As the distances of the orifice are increased, the jet penetrations of the rear orifice decrease.

  • PDF

Prediction of chloride penetration into hardening concrete (경화중 콘크리트의 염해 침투성능에 관한 연구)

  • Fan, Wei-Jie;Wang, Xiao-Yong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.50-51
    • /
    • 2015
  • In marine and coastal environments, penetration of chloride ions is one of the main mechanisms causing concrete reinforcement corrosion. Currently, most of experimental investigations about submerged penetration of chloride ions are started after the four weeks standard curing of concrete. The further hydration of cement and reduction of chloride diffusivity during submerged penetration period are ignored. To overcome this weak point, this paper presents a numerical procedure to analyze simultaneously cement hydration reaction and chloride ion penetration process. First, using a cement hydration model, degree of hydration and phase volume fractions of hardening concrete are determined. Second, the dependences of chloride diffusivity and chloride binding capacity on age of concrete are clarified. Third, chloride profiles in hardening concrete are calculated. The proposed numerical procedure is verified by using chloride penetration test results of concrete with different mixing proportions.

  • PDF

Reduction of Grid Size Dependency in DME Spray Modeling with Gas-jet Model (가스 제트 모델을 이용한 DME 분무 해석의 격자 의존성 저감)

  • Oh, Yun-Jung;Kim, Sa-Yop;Lee, Chang-Sik;Park, Sung-Wook
    • Journal of ILASS-Korea
    • /
    • v.15 no.4
    • /
    • pp.170-176
    • /
    • 2010
  • This paper describes the grid-size dependency of the conventional Eulerian-Lagrangian method to spray characteristics such as spray penetration and SMD in modeling DME sprays. In addition, the reduction of the grid-size dependency of the present Gas-jet model was investigated. The calculations were performed using the KIVA code and the calculated results were compared to those of experimental result. The results showed that the conventional Eulerian-Laglangian model predicts shorter spray penetration for large cell because of inaccurate calculation of momentum exchange between liquid and gas phase. However, it was shown that the gas-jet model reduced grid-size dependency to spray penetration by calculating relative velocity between liquid and ambient gas based on gas jet velocity.