• Title/Summary/Keyword: Pedicle screw fixation

Search Result 83, Processing Time 0.019 seconds

Short Segment Pedicle Screw Fixation with Augmented Intra-Operative Vertebroplasty in Unstable Thoraco-Lumbar Fracture - Preliminary Report - (불안정성 흉·요추부 골절에 대한 단 분절 척추경 나사못 고정술 및 추체 보강 성형술 - 예 비 보 고 -)

  • Kim, Young Woo;Oh, Sung Han;Yoon, Do Heum;Chin, Dong Kyu;Cho, Yong Eun;Kim, Young Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1271-1277
    • /
    • 2001
  • Objectives : Since vertebroplasty has been introduced, we performed short segment pedicle screw fixation with augmented intra-operative vertebroplasty in patients with unstable thoraco-lumbar fracture. Our intentions are to demonstrate the efficacy and indication of this new technique compare to conventional methods. Material and Methods : The surgery comprised of pedicle screw fixations on one level above and below the fracture site, and the fractured level itself, if pedicle is intact, and intra-operative vertebroplasty under the fluoroscopic guide with in-situ postero-lateral bone graft. Also, in cases of bone apposition, we removed those with small impactor through a transfascetal route. During the last 2 years, we performed in seven(7) unstable thoraco-lumbar fracture patients who consisted of two different characteristics, those four(4) with primary or secondary osteoporosis and three(3) of young and very healthy. All patients were followed clinically by A.S.I.A. score and radiography. Results : Mean follow up period was 14 months. We observed well decompressed state via transfascetal route in cases of bone fragments apposition and no hardware pullout in osteoporotic cases, no poly-methyl-methacrylate (PMMA) leakage through the fracture sites into the spinal canal, and no kyphotic deformities in both cases during follow-up periods. All patients demonstrated solid bony fusion except one following osteoporotic compression fracture on other sites. Conclusions : In the management of unstable thoraco-lumbar fracture, we believe that this short segment pedicle screw fixation with augmented intra-operative vertebroplasty reduce the total length or levels of pedicle screw fixation without post-operative kyphotic deformity.

  • PDF

Posterior Interspinous Fusion Device for One-Level Fusion in Degenerative Lumbar Spine Disease : Comparison with Pedicle Screw Fixation - Preliminary Report of at Least One Year Follow Up

  • Kim, Ho Jung;Bak, Koang Hum;Chun, Hyoung Joon;Oh, Suck Jun;Kang, Tae Hoon;Yang, Moon Sool
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.359-364
    • /
    • 2012
  • Objective : Transpedicular screw fixation has some disadvantages such as postoperative back pain through wide muscle dissection, long operative time, and cephalad adjacent segmental degeneration (ASD). The purposes of this study are investigation and comparison of radiological and clinical results between interspinous fusion device (IFD) and pedicle screw. Methods : From Jan. 2008 to Aug. 2009, 40 patients underwent spinal fusion with IFD combined with posterior lumbar interbody fusion (PLIF). In same study period, 36 patients underwent spinal fusion with pedicle screw fixation as control group. Dynamic lateral radiographs, visual analogue scale (VAS), and Korean version of the Oswestry disability index (K-ODI) scores were evaluated in both groups. Results : The lumbar spine diseases in the IFD group were as followings; spinal stenosis in 26, degenerative spondylolisthesis in 12, and intervertebral disc herniation in 2. The mean follow up period was 14.24 months (range; 12 to 22 months) in the IFD group and 18.3 months (range; 12 to 28 months) in pedicle screw group. The mean VAS scores was preoperatively $7.16{\pm}2.1$ and $8.03{\pm}2.3$ in the IFD and pedicle screw groups, respectively, and improved postoperatively to $1.3{\pm}2.9$ and $1.2{\pm}3.2$ in 1-year follow ups (p<0.05). The K-ODI was decreased significantly in an equal amount in both groups one year postoperatively (p<0.05). The statistics revealed a higher incidence of ASD in pedicle screw group than the IFD group (p=0.029) Conclusion : Posterior IFD has several advantages over the pedicle screw fixation in terms of skin incision, muscle dissection and short operative time and less intraoperative estimated blood loss. The IFD with PLIF may be a favorable technique to replace the pedicle screw fixation in selective case.

Clinical and Computed Tomography Evaluation of Plate and Screw on the Cervical Lateral Mass : A Modified Magerl's Technique

  • Lee, Dong-Chan;Yoon, Seung-Hwan;Park, Hyung-Chun;Park, Jong-Oon;Hyun, Dong-Keun;Park, Heon-Seon
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.251-255
    • /
    • 2006
  • Objective : To determine the clinical and radiological safety of 15 consecutive patients managed with plate and screw fixation systems applied to the cervical lateral mass. Methods : 15 patients who underwent posterior cervical and T1 arthrodesis were reviewed from Jan 2002 to Dec 2004. Posterior cervical screw and plate fixation was applied on the lateral mass of the cervical spine. The authors have tried lateral mass screw fixation using a modified Magerl's technique [$20^{\circ}$ lateral and $20{\sim}30^{\circ}$ rostral screw trajectory] under preliminary radiological study. The average patient age was $39.73^{\circ}{\pm}11.00\;years$, and the average follow-up period was $9.73^{\circ}{\pm}6.77\;months$. Computed tomography scans taken after surgery were reviewed to confirm the attempted screw trajectory correct and safety. Results : Three of 93 lateral mass screws were malpositioned but clinical damage was not noted. Two of 8 pedicle screws on the T1 vertebrae were not placed on the correct pedicle area. Screw and plate loosening was observed in one case but was not subjected to an additional procedure because of maintained screw position observed during follow-up periods. Conclusion : The results of this study indicate that lateral mass screw fixation using the Modified Magerl's technique on the cervical lateral mass may provide safe and effective application on the patients. In addition, the chance of incorrectly placed screws was higher in T1 pedicle screw fixation than in lateral mass screw fixation of the cervical area.

Pedicle Morphometry for Thoracic Screw Fixation in Ethnic Koreans : Radiological Assessment Using Computed Tomographic Myelography

  • Choi, Yang-Soo;Kim, Young-Jin;Yi, Hyeong-Joong;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.317-321
    • /
    • 2009
  • Objective : In the thoracic spine, insertion of a pedicle screw is annoying due to small pedicle size and wide morphological variation between different levels of the spine and between individuals. The aim of our study was to analyze radiologic parameters of the pedicle morphometry from T1 to T8 using computed tomographic myelography (CTM) in Korean population. Methods : For evaluation of the thoracic pedicle morphometry, the authors prospectively analyzed a consecutive series of 26 patients with stable thoracic spines. With the consent of patients, thoracic CTM were performed, from T1 to T8. We calculated the transverse outer diameters and the transverse angles of the pedicle, distance from the cord to the inner cortical wall of the pedicle, and distance from the cord to the dura. Results : Transverse outer pedicle diameter was widest at T1 ($7.66{\pm}2.14\;mm$) and narrowest at T4 ($4.38{\pm}1.55\;mm$). Transverse pedicle angle was widest at T1 ($30.2{\pm}12.0^{\circ}$ and it became less than $9.0^{\circ}$ below T6 level. Theoretical safety zone of the medial perforation of the pedicle screw, namely, distance from the cord to inner cortical wall of the pedicle was more than 4.5 mm. Conclusion : Based on this study, we suggest that the current pedicle screw system is not always suitable for Korean patients. Computed tomography is required before performing a transpedicular screw fixation at the thoracic levels.

Limited Unilateral Decompression and Pedicle Screw Fixation with Fusion for Lumbar Spinal Stenosis with Unilateral Radiculopathy : A Retrospective Analysis of 25 Cases

  • Zhang, Li;Miao, Hai-xiong;Wang, Yong;Chen, An-fu;Zhang, Tao;Liu, Xiao-guang
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.1
    • /
    • pp.65-71
    • /
    • 2015
  • Objective : Lumbar spinal stenosis is conventionally treated with surgical decompression. However, bilateral decompression and laminectomy is more invasive and may not be necessary for lumbar stenosis patients with unilateral radiculopathy. We aimed to report the outcomes of unilateral laminectomy and bilateral pedicle screw fixation with fusion for patients with lumbar spinal stenosis and unilateral radiculopathy. Methods : Patients with lumbar spinal stenosis with unilateral lower extremity radiculopathy who received limited unilateral decompression and bilateral pedicle screw fixation were included and evaluated using visual analog scale (VAS) pain and the Oswestry Disability Index (ODI) scores preoperatively and at follow-up visits. Ligamentum flavum thickness of the involved segments was measured on axial magnetic resonance images. Results : Twenty-five patients were included. The mean preoperative VAS score was $6.6{\pm}1.6$ and $4.6{\pm}3.1$ for leg and back pain, respectively. Ligamentum flavum thickness was comparable between the symptomatic and asymptomatic side (p=0.554). The mean follow-up duration was 29.2 months. The pain in the symptomatic side lower extremity (VAS score, $1.32{\pm}1.2$) and the back (VAS score, $1.75{\pm}1.73$) significantly improved (p=0.000 vs. baseline for both). The ODI improved significantly postoperatively ($6.60{\pm}6.5$; p=0.000 vs. baseline). Significant improvement in VAS pain and ODI scores were observed in patients receiving single or multi-segment decompression fusion with fixation (p<0.01). Conclusion : Limited laminectomy and unilateral spinal decompression followed by bilateral pedicle screw fixation with fusion achieves satisfactory outcomes in patients with spinal stenosis and unilateral radiculopathy. This procedure is less damaging to structures that are important for maintaining posterior stability of the spine.

Pedicular and Extrapedicular Morphometric Analysis in the Korean Population : Computed Tomographic Assessment Relevance to Pedicle and Extrapedicle Screw Fixation in the Thoracic Spine

  • Kim, Jun-Hak;Choi, Gyeong-Mi;Chang, In-Bok;Ahn, Sung-Ki;Song, Joon-Ho;Choi, Hyun-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.3
    • /
    • pp.181-188
    • /
    • 2009
  • Objective : To evaluate the anatomical parameters that must be considered when performing thoracic transpedicular or extrapedicular screw fixation. Methods : We selected 958 vertebrae (1,916 pedicles) from 98 patients for analysis. Eight parameters were measured from CT scans : the transverse outer pedicular diameter, transverse inner pedicular diameter, length, angle, chord length of the pedicles and the transverse width, angle, and chord length of the pedicle-rib units. Results : The age of the patients ranged from 21 to 82 years (mean: 48.2 years) and there were 57 men and 41 women. The narrowest transverse outer pedicular diameter was at T5 (4.4 mm). The narrowest pedicle length was at T1 (15.9 mm). For pedicle angle, T1 was 31.6 degrees, which was the most convergent angle, and it showed the tendency of the lower the level, the lesser the convergent angle. The chord length showed a horizontal pattern with similar values at all levels. For the PRU width, T5 showed a similar pattern to the pedicle width at 13.4 mm. For the PRU angle, T1 was the largest angle at 46.2 degrees and the tendency was the lower the level. the narrower the angle. For chord length, T1 was the shortest at 46.9 mm and T8 was the longest at 60.1 mm. Conclusion : When transpedicular screw fixations carried out at the mid-thoracic level, special care must be taken because there is a high chance of danger of medial wall violation. In these circumstances, extrapedicular screw fixation may be considered as an alternative treatment.

Targeting a Safe Entry Point for C2 Pedicle Screw Fixation in Patients with Atlantoaxial Instability

  • Chun, Hyoung-Joon;Bak, Koang-Hum
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.6
    • /
    • pp.351-354
    • /
    • 2011
  • Objective : This investigation was conducted to evaluate a new, safe entry point for the C2 pedicle screw, determined using the anatomical landmarks of the C2 lateral mass, the lamina, and the isthmus of the pars interarticularis. Methods : Fifteen patients underwent bilateral C1 lateral mass-C2 pedicle screw fixation, combined with posterior wiring. The C2 pedicle screw was inserted at the entry point determined using the following method : 4 mm lateral to and 4 mm inferior to the transitional point (from the superior end line of the lamina to the isthmus of the pars interarticularis). After a small hole was made with a high-speed drill, the taper was inserted with a 30 degree convergence in the cephalad direction. Other surgical procedures were performed according to Harm's description. Preoperatively, careful evaluation was performed with a cervical X-ray for C1-C2 alignment, magnetic resonance imaging for spinal cord and ligamentous structures, and a contrast-enhanced 3-dimensional computed tomogram (3-D CT) for bony anatomy and the course of the vertebral artery. A 3-D CT was checked postoperatively to evaluate screw placement Results : Bone fusion was achieved in all 15 patients (100%) without screw violation into the spinal canal, vertebral artery injury, or hardware failure. Occipital neuralgia developed in one patient, but this subsided after a C2 ganglion block. Conclusion : C2 transpedicular screw fixation can be easily and safely performed using the entry point of the present study. However, careful preoperative radiographic evaluation, regardless of methods, is mandatory.

A study on the finite element analysis and machining methods for optimum design of pedicle screw system (척추경나사의 최적설계를 위한 유한요소해석과 형성가공에 관한 연구)

  • 남기우;장성민;이성희;조명우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.634-638
    • /
    • 1997
  • The objectives of this research are to develop lumber and lower-thoracic pedicle fixation system for Korean patients. To achieve the aimed goals, first, optimized shape design process is performed, and finite element methods are applied to evaluate the mechanical strength of the developed fixation system. Second, appropriate machining experiments are carried out to develop optimum machining conditions for titan~um alloys those are known as one of the most difficult-to-cut material. As the results of this research, new pedicle screw system, considering the morphological characteristics of Korean patients, is developed by applying the finite element analysis, optimum shape processing method and optimize design algorithm.

  • PDF

A Case of Pedicle Screw Loosening Treated by Modified Transpedicular Screw Augmentation with Polymethylmethacrylate

  • Kang, Suk-Hyung;Kim, Kyoung-Tae;Park, Seung-Won;Kim, Young-Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.1
    • /
    • pp.75-78
    • /
    • 2011
  • We report a case of pedicle screw loosening treated by modified transpedicular screw augmentation technique using polymethylmethacrylate(PMMA), which used the anchoring effect of hardened PMMA. A 56-year-old man who had an L3/4/5 fusion operation 3 years ago complained of continuous low back pain after this operation. The computerized tomography showed a radiolucent halo around the pedicle screw at L5. We augmented the L5 pedicle screw with modified pedicle screw augmentation technique using PMMA and performed an L3/4/5 pedicle screw fixation without hook or operation field extension. This modified technique is a kind of transpedicular stiffness augmentation using PMMA for the dead space around the loosed screw. After filling the dead space with 1-2 cc of PMMA, we inserted a small screw. Once the PMMA hardened, we removed the small screw and inserted a thicker screw along the existing screw threading to improve the pedicle screws' pullout strength. At 10 months' follow-up, x-ray showed strong fusion of L3/4/5. The visual analogue scale (VAS) of his back pain was improved from 9 to 5. This modified transpedicular screw augmentation with PMMA using anchoring effect is a Simple and effective surgical technique for pedicle screw loosening. However, clinical analyses of long-term follow-up and biomechanical studies are needed.

Short-segment Pedicle Instrumentation of Thoracolumbar Burst-compression Fractures; Short Term Follow-up Results

  • Shin, Tae-Sob;Kim, Hyun-Woo;Park, Keung-Suk;Kim, Jae-Myung;Jung, Chul-Ku
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.265-270
    • /
    • 2007
  • Objective : The current literature implies that the use of short-segment pedicle screw fixation for spinal fractures is dangerous and inappropriate because of its high failure rate, but favorable results have been reported. The purpose of this study is to report the short term results of thoracolumbar burst and compression fractures treated with short-segment pedicle instrumentation. Methods : A retrospective review of all surgically managed thoracolumbar fractures during six years were performed. The 19 surgically managed patients were instrumented by the short-segment technique. Patients' charts, operation notes, preoperative and postoperative radiographs (sagittal index, sagittal plane kyphosis, anterior body compression, vertebral kyphosis, regional kyphosis), computed tomography scans, neurological findings (Frankel functional classification), and follow-up records up to 12-month follow-up were reviewed. Results : No patients showed an increase in neurological deficit. A statistically significant difference existed between the patients preoperative, postoperative and follow-up sagittal index, sagittal plane kyphosis, anterior body compression, vertebral kyphosis and regional kyphosis. One screw pullout resulted in kyphotic angulation, one screw was misplaced and one patient suffered angulation of the proximal segment on follow-up, but these findings were not related to the radiographic findings. Significant bending of screws or hardware breakage were not encountered. Conclusion : Although long term follow-up evaluation needs to verified, the short term follow-up results suggest a favorable outcome for short-segment instrumentation. When applied to patients with isolated spinal fractures who were cooperative with 3-4 months of spinal bracing, short-segment pedicle screw fixation using the posterior approach seems to provide satisfactory result.