• Title/Summary/Keyword: Peak to peak amplitude

Search Result 507, Processing Time 0.031 seconds

DWT-Based Parameter and Iteration Algorithm for Preventing Arc False Detection in PV DC Arc Fault Detector (태양광 직렬 아크 검출기의 오검출 방지를 위한 DWT 기반 파라미터 및 반복 알고리즘)

  • Ahn, Jae-Beom;Lee, Jin-Han;Lee, Jin;Ryoo, Hong-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.100-105
    • /
    • 2022
  • This paper applies the arc detection algorithm to prevent the false detection in photo voltaic series arc detection circuit, which is required not only to detect the series arc quickly, but also not falsely detect the arc for the non-arc noise. For this purpose, this study proposes a rapid and preventive false detection method of single peak noise and short noise signals. First, to prevent false detection by single peak noise, Discrete wavelet transform (DWT)-based characteristic parameters are applied to determine the shape and the amplitude of the noise. In addition, arc fault detection within a few milliseconds is performed with the DWT iterative algorithm to quickly prevent false detection for short noise signals, considering the continuity of serial arc noise. Thus, the method operates not only to detect series arc, but also to avoid false arc detection for peak and short noises. The proposed algorithm is applied to real-time serial arc detection circuit based on the TMS320F28335 DSP. The serial arc detection and peak noise filtering performances are verified in the built simulated arc test facility. Furthermore, the filtering performance of short noise generated through DC switch operation is confirmed.

Pharmacodynamic Interactions of Diazepam and Flumazenil on Cortical Eeg in Rats (흰쥐 대뇌피질의 뇌파에 대한 diazepam 및 flumazenil의 약력학적 상호작용)

  • 이만기
    • Biomolecules & Therapeutics
    • /
    • v.7 no.3
    • /
    • pp.242-248
    • /
    • 1999
  • Diazepam, a benzodiazepine (BDZ) agonist, produces sedation and flumazenil, a BDZ antagonist, blocks these actions. The aim of this study was to examine the effects of BDZs on cortical electroencephalogram (EEG) in rats. The recording electrodes were implanted over the frontal and parietal cortices bilaterally, and the reference and ground electrodes over cerebellum under ketamine anesthesia. To assess the effects of diazepam and flumazenil, rats were injected with diazepam (1 mgHg, i.p.) and/or flumazenil ( 1 mg/kg, i.p.), and the EEG was recorded before and after drugs. Normal awake had theta peak in the spectrum and low amplitude waves, while normal sleep showed large amplitude of slow waves. The powers of delta, theta and alpha bands were increased during sleep compared with during awake. Diazepam reduced the mobility of the rat and induced sleep with intermittent fast spindles and large amplitude of slow activity, and it produced broad peak over betaL band and increased the power of gamma band, which were different from EEG patterns in normal sleep. Saline injection awakened rats and abolished fast spindles for a short period about 2-5 min from EEG pattern during diazepam-induced sleep. Flumazenil blocked both diazepam-induced sleep and decreased the slow activities of delta, theta, alpha and betaL, but not of gamma activity for about 10 min or more. This study may indicate that decrease in power of betaL and betaH bands can be used as the measure of central action of benzodiazepines, and that the EEG parameters of benzodiazepines have to be measured without control over the behavioral state by experimenter.

  • PDF

Statistical Properties of Electric Fields Produced by Cloud-to-Ground Lightning Return Strokes

  • Lee, Bok-Hee;Lee, Dong-Moon;Lee, Seung-Chil;Ahn, Chang-Hwan
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.11C no.4
    • /
    • pp.120-126
    • /
    • 2001
  • For the past five years, Inha University has been observing the electric fields produced by cloud-to-ground return strokes. This paper presents the summary of most recent results. Statistics on the zero-to-peak rise time, the zero-to-zero crossing time and the amplitude ratio of the second peak in the opposite polarity to the first peak were examined. The radiation electric fields produced by distant cloud-to-ground return strokes were substantially same pattern. The first return stroke field starts with a slowly increasing front and rises abruptly to peak. The rising portions of the electric fields produced by cloud-to-ground return strokes last 1 $mutextrm{s}$ to a few $mutextrm{s}$. The mean values of the zero-to-peak rise times of electric fields were 5.72 $mutextrm{s}$ and 4.12 $mutextrm{s}$ for the positive and the negative cloud-to-ground return strokes, respectively. The mean of the zero-to-zero crossing time for the positive return strokes was 29.48 $mutextrm{s}$ compared with 38.54 $mutextrm{s}$ for the negative return strokes. The depths of the dip after the peak of return stroke electric fields also have the dependence on the polarity of cloud-to-ground return stroke, and the mean values for the positive and negative cloud-to-ground return strokes were 33.55 and 28.19%, respectively.

  • PDF

Automated structural modal analysis method using long short-term memory network

  • Jaehyung Park;Jongwon Jung;Seunghee Park;Hyungchul Yoon
    • Smart Structures and Systems
    • /
    • v.31 no.1
    • /
    • pp.45-56
    • /
    • 2023
  • Vibration-based structural health monitoring is used to ensure the safety of structures by installing sensors in structures. The peak picking method, one of the applications of vibration-based structural health monitoring, is a method that analyze the dynamic characteristics of a structure using the peaks of the frequency response function. However, the results may vary depending on the person predicting the peak point; further, the method does not predict the exact peak point in the presence of noise. To overcome the limitations of the existing peak picking methods, this study proposes a new method to automate the modal analysis process by utilizing long short-term memory, a type of recurrent neural network. The method proposed in this study uses the time series data of the frequency response function directly as the input of the LSTM network. In addition, the proposed method improved the accuracy by using the phase as well as amplitude information of the frequency response function. Simulation experiments and lab-scale model experiments are performed to verify the performance of the LSTM network developed in this study. The result reported a modal assurance criterion of 0.8107, and it is expected that the dynamic characteristics of a civil structure can be predicted with high accuracy using data without experts.

Electrochemical Behavior and Differential Pulse Polarographic Determination of Rifampicin in the Pharmaceutical Preparations

  • Hahn, Young-Hee;Shin, Sun-Mi
    • Archives of Pharmacal Research
    • /
    • v.24 no.2
    • /
    • pp.100-104
    • /
    • 2001
  • Differential pulse polarographic(DPP) analytical procedure for the rifampicin antibiotic, which can be applied to monitor its synthetic process from the starting antibiotic of rifamycin B or rifamycin SV has been developed based on the electrochemical reduction of an azomethine group. Rifampicin exhibited a cathodic peak due to the azomethine group in the side chain of 3-[(4-methyl-1-piperazinyl)imino]methyl moiety and another cathodic peak due to the carbonyl group in rifamycin SV by DPP. The experimental peak potential shift of an azomethine reduction was -73 mV/pH in the pH range between 3.0 and 7.5, agreeing with involvement of 4 e-and 5 $H^5$ in its reduction. By the cyclic voltammetric(CV) studies, the azomethine and the carbonyl reductions in rifampicin were processed irreversibly on the mercury electrode. The plot of peak currents vs. concentrations of rifampicin ranging $1.0{\times}10^{-7} M~$1.0{\times}10^{-5} M yielded a straight line with a correlation coefficient of 0.9996. The detection limit was $1.0{\times}10^{-8} M with a modulation amplitude of 50 mV DPP has been successfully applied for the determination of rifampicin in the pharmaceutical preparations.

  • PDF

Development of continuous blood pressure measurement system using ECG and PPG (ECG와 PPG를 이용한 실시간 연속 혈압 측정 시스템)

  • Kim, Jong-Hwa;Whang, Min-Cheol;Nam, Ki-Chang
    • Science of Emotion and Sensibility
    • /
    • v.11 no.2
    • /
    • pp.235-244
    • /
    • 2008
  • This study is to develop automatic extraction system of continuous blood pressure using ECG (Electrocardiogram) and PPG(Photoplethysmography) for u-health care technology. PTT (Pulse Transit Time) was determined from peak difference between ECG and PPG and its inverse made to get blood pressure. Since the peaks were vulnerable to be contaminated from noise and variation of amplitude, this study developed the adaptive algorithm for peak calculation in any noise condition. The developed method of the adaptive peak calculation was proven to make the standard deviations of PPT decrease to 28% and the detection of noise increase to 18%. Also, the correlation model such as blood pressure = -0.044 $\cdot$ PTT + 133.592 has successfully been determined for predicting the continuous pressure measured without using cuff but with using PPG and ECG, only.

  • PDF

Multi-stage and Variable-length Peak Windowing Techniques for PAPR Reduction of OFDMA Downlink Systems (OFDMA 하향링크 시스템에서의 PAPR 저감을 위한 다단계 및 가변길이 첨두 윈도윙 기법들)

  • Lee, Sung-Eun;Min, Hyun-Kee;Bang, Keuk-Joon;Hong, Dae-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.2
    • /
    • pp.67-74
    • /
    • 2008
  • This paper proposes two peak-windowing algorithms for peak-to-average power reduction(PAPR) of orthogonal frequency division multiple access(OFDMA) downlink systems. The Proposed algorithms mitigate the effect of excessive suppression due to successive peaks or relatively high peaks of the signal. First, multi-stage peak windowing algorithm is proposed, which exploits multiple threshold of target PAPR in order to step down the peaks gradually. Secondary, variable-length peak windowing algorithm is proposed, which adapts the window length with respect to the existence of successive peaks within a half of window length. Therefore, the proposed method reduces the distortion of signal amplitude caused by window overlapping. The proposed algorithms outperform the conventional peak windowing with the aid of window-length adaptation or sequential peak power reduction. Simulation results show the efficiency of the proposed algorithms over OFDMA downlink systems, especially WiBro systems.

Effects of stimulus similarity on P300 amplitude in P300-based concealed information test (P300-기반 숨긴정보검사에서 자극유사성이 P300의 진폭에 미치는 영향)

  • Eom, Jin-Sup;Han, Yu-Hwa;Sohn, Jin-Hun;Park, Kwang-Bai
    • Science of Emotion and Sensibility
    • /
    • v.13 no.3
    • /
    • pp.541-550
    • /
    • 2010
  • The present study examined whether the physical similarity of test stimuli affects P300 amplitude and detection accuracy for the P300-based concealed information test (P300 CIT). As the participant pretended suffering from memory impairment by an accident, own name was used as a concealed information to be probed by the P300 CIT in which the participant discriminated between a target and other (probe, irrelevant) stimuli. One group of participants was tested in the easy task condition with low physical similarity among stimuli, the other group was tested in the difficult task condition with high physical similarity among stimuli. Using the base-to-peak P300 amplitude, the interaction effect of task difficulty and stimulus type was significant at $\alpha$=.1 level (p=.052). In the easy task condition the difference of P300 amplitude between the probe and the irrelevant stimuli was significant, while in the difficult task condition the difference was not significant. Using peak-to-peak P300 amplitude, on the other hand, the interaction effect of task difficulty and stimulus type was not significant with significant differences of P300 amplitude between the probe and the irrelevant stimuli in both task difficulty conditions. The difference of detection accuracy between task conditions was not significant with both measures of P300 amplitude although the difference was much smaller when peak-to-peak P300 amplitude was used. The results suggest that the efficiency of P300 CIT would not decrease even when the perceptual similarity among test stimuli is high.

  • PDF

Reproducibility of Electromyography Signal Amplitude during Repetitive Dynamic Contraction

  • Mo, Seung-Min;Kwag, Jong-Seon;Jung, Myung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.689-694
    • /
    • 2011
  • Objective: The aim of this study is to evaluate the fluctuation of signal amplitude during repetitive dynamic contraction based on surface electromyography(EMG). Background: The most previous studies were considered isometric muscle contraction and they were difference to smoothing window length by moving average filter. In practical, the human movement is dynamic state. Dynamic EMG signal which indicated as the nonstationary pattern should be analyzed differently compared with the static EMG signal. Method: Ten male subjects participated in this experiment, and EMG signal was recorded by biceps brachii, anterior/posterior deltoid, and upper/lower trapezius muscles. The subject was performed to repetitive right horizontal lifting task during ten cycles. This study was considered three independent variables(muscle, amplitude processing technique, and smoothing window length) as the within-subject experimental design. This study was estimated muscular activation by means of the linear envelope technique(LE). The dependent variable was set coefficient of variation(CV) of LE for each cycle. Results: The ANOVA results showed that the main and interaction effects between the amplitude processing technique and smoothing window length were significant difference. The CV value of peak LE was higher than mean LE. According to increase the smoothing window length, this study shows that the CV trend of peak LE was decreased. However, the CV of mean LE was analyzed constant fluctuation trend regardless of the smoothing window length. Conclusion: Based on these results, we expected that using the mean LE and 300ms window length increased reproducibility and signal noise ratio during repetitive dynamic muscle contraction. Application: These results can be used to provide fundamental information for repetitive dynamic EMG signal processing.

N100 Amplitude Slopes in Major Depressive Disorder, Bipolar Disorder, Schizophrenia and Normal Controls (주요 우울 장애, 정신분열병, 양극성 장애 및 정상 대조군에서의 N100 진폭경사)

  • Yang, Eunkyoung;Lee, Seung-Hwan;Oh, Sunghee;Kim, Sangrae
    • Korean Journal of Biological Psychiatry
    • /
    • v.16 no.3
    • /
    • pp.181-189
    • /
    • 2009
  • Objectives : N100 amplitude slope(the intensity dependence of the cortical auditory evoked potentials) is widely considered as an indirect indicator of central serotonergic neurotransmission. However, there are only a few studies about N100 amplitude slopes of major psychiatric disorders. In this study, we examined N100 amplitude slope differences among major depressive disorder(MDD), bipolar disorder(BD), schizophrenia (SCZ) and normal controls(NC). Methods : We measured the N100 amplitude slopes of 35 patients with MDD, 33 patients with BD, 27 patients with SCZ and 35 NC subjects. Amplitude differences from N1 to P2 at the five different sound intensities(55, 65, 75, 85 and 95dB) were examined at Cz electrode. The N100 amplitude slope was calculated as the linear regression of five N1/P2 peak-to-peak amplitudes across stimulus intensities. Results : BD patients showed significantly reduced N100 amplitude slope compared with NC(0.54${\pm}$0.70 vs. 0.96${\pm}$0.72, p=0.035). N100 amplitude slope of SCZ patients was significantly reduced compared with NC(0.50${\pm}$0.47 vs. 0.96${\pm}$0.72, p=0.027). N100 amplitude slope of BD patients was significantly lower than that of MDD patients(0.54${\pm}$0.70 vs. 0.94${\pm}$0.60, p=0.046). SCZ patients also showed significant reduction of N100 amplitude slope compared with MDD patients(0.50${\pm}$0.47 vs. 0.94${\pm}$0.60, p=0.036). There was no significant difference of N100 amplitude slope between MDD patients and NC(0.94${\pm}$0.60 vs. 0.96${\pm}$0.72, p=1.000). Conclusion : Interestingly, the N100 amplitude slopes of BD and SCZ were reduced compared to NC and MDD patients. Our results suggest the predictive use of N100 amplitude slope in making differential diagnoses of major psychiatric disorders. Clinical implications of N100 amplitude slope in major psychiatric disorders were discussed.

  • PDF