• Title/Summary/Keyword: Peak to Peak Analysis

Search Result 4,798, Processing Time 0.032 seconds

A Study on the Optimal Operation of 2010 Summer Peak in Korea Power System (2010년 여름철 전력계통 최적 운영에 관한 연구)

  • Lee, Sung-Moo;Cho, Jong-Man;Kim, Kyu-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1733-1740
    • /
    • 2010
  • KPX(Korea Power Exchange) predicts that summer peak load will be 70,700MW and system overload will be 150% from contingency analysis. This paper presents a method to operate power system at 2010 summer peak. about equipment variation, power system variation, analysis results of voltage stability, and the method to relief overload by comparing 2009 and 2010. Especially, transmission constraints to prevent global contingency in Korea power system and the role of SPS(Special Protection System) to prevent voltage collapse when fault occurs are introduced.

Assessing Unit Hydrograph Parameters and Peak Runoff Responses from Storm Rainfall Events: A Case Study in Hancheon Basin of Jeju Island

  • Kar, Kanak Kanti;Yang, Sung-Kee;Lee, Jun-Ho
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.437-447
    • /
    • 2015
  • Estimation of runoff peak is needed to assess water availability, in order to support the multifaceted water uses and functions, hence to underscore the modalities for efficient water utilization. The magnitude of storm rainfall acts as a primary input for basin level runoff computation. The rainfall-runoff linkage plays a pivotal role in water resource system management and feasibility level planning for resource distribution. Considering this importance, a case study has been carried out in the Hancheon basin of Jeju Island where distinctive hydrological characteristics are investigated for continuous storm rainfall and high permeable geological features. The study aims to estimate unit hydrograph parameters, peak runoff and peak time of storm rainfalls based on Clark unit hydrograph method. For analyzing observed runoff, five storm rainfall events were selected randomly from recent years' rainfall and HEC-hydrologic modeling system (HMS) model was used for rainfall-runoff data processing. The simulation results showed that the peak runoff varies from 164 to 548 m3/sec and peak time (onset) varies from 8 to 27 hours. A comprehensive relationship between Clark unit hydrograph parameters (time of concentration and storage coefficient) has also been derived in this study. The optimized values of the two parameters were verified by the analysis of variance (ANOVA) and runoff comparison performance were analyzed by root mean square error (RMSE) and Nash-Sutcliffe efficiency (NSE) estimation. After statistical analysis of the Clark parameters significance level was found in 5% and runoff performances were found as 3.97 RMSE and 0.99 NSE, respectively. The calibration and validation results indicated strong coherence of unit hydrograph model responses to the actual situation of historical storm runoff events.

Prediction of Peak Back Compressive Forces as a Function of Lifting Speed and Compressive Forces at Lift Origin and Destination - A Pilot Study

  • Greenland, Kasey O.;Merryweather, Andrew S.;Bloswick, Donald S.
    • Safety and Health at Work
    • /
    • v.2 no.3
    • /
    • pp.236-242
    • /
    • 2011
  • Objectives: To determine the feasibility of predicting static and dynamic peak back-compressive forces based on (1) static back compressive force values at the lift origin and destination and (2) lifting speed. Methods: Ten male subjects performed symmetric mid-sagittal floor-to-shoulder, floor-to-waist, and waist-to-shoulder lifts at three different speeds (slow, medium, and fast), and with two different loads (light and heavy). Two-dimensional kinematics and kinetics were captured. Linear regression analyses were used to develop prediction equations, the amount of predictability, and significance for static and dynamic peak back-compressive forces based on a static origin and destination average (SODA) backcompressive force. Results: Static and dynamic peak back-compressive forces were highly predicted by the SODA, with R2 values ranging from 0.830 to 0.947. Slopes were significantly different between slow and fast lifting speeds (p < 0.05) for the dynamic peak prediction equations. The slope of the regression line for static prediction was significantly greater than one with a significant positive intercept value. Conclusion: SODA under-predict both static and dynamic peak back-compressive force values. Peak values are highly predictable and could be readily determined using back-compressive force assessments at the origin and destination of a lifting task. This could be valuable for enhancing job design and analysis in the workplace and for large-scale studies where a full analysis of each lifting task is not feasible.

Changes in Peak Expiratory Flow, Forced Expiratory Volume in 1 Second and Peak Cough Flow Related to Functional Level and Measurement Position in Patients With Duchenne Muscular Dystrophy (뒤시엔느 근 이영양증 환자에서 기능 수준과 측정 자세에 따른 최대호기유량, 1초간노력성호기량 및 최대기침유량의 변화)

  • Kim, Ki-Song;Cynn, Heon-Seock
    • Physical Therapy Korea
    • /
    • v.16 no.3
    • /
    • pp.1-8
    • /
    • 2009
  • It is important to find the effective position for cough and sputum clearance in respiratory physical therapy. The purpose of this study was to compare the changes in peak expiratory flow (PEF), forced expiratory volume in 1 second ($FEV_1$), and peak cough flow (PCF) related to functional level and measurement position in patients with Duchenne muscular dystrophy. Twenty one subjects were classified into three functional levels, and measurements was undertaken in three different measurement positions (upright sitting, $45^{\circ}$ reclining and supine). Vitalograph PEF/FEV DIARY was used to measure PEF and $FEV_1$, and Ferraris Pocket Peak was used to measure PCF. Mixed two-way analysis of variance and Bonferroni post-hoc test were used for statistical analysis. The results of the study were as follows: 1) Significant main effects for measurement position were found. 2) PEF was the highest in upright sitting, followed by $45^{\circ}$ reclining, and supine in order. 3) $FEV_1$ in upright sitting and $45^{\circ}$ reclining were significantly greater compared with that in supine. 4) PCF in upright sitting and $45^{\circ}$ reclining were significantly greater compared with that in supine. 5) No significant main effects for functional level were found in PEF, $FEV_1$, and PCF. 6) No significant functional level by measurement position interactions were found in PEF, $FEV_1$, and PCF. Therefore, it is concluded that upright sitting and $45^{\circ}$ degree reclining positions are recommended for effective cough and sputum clearance.

  • PDF

A Study on the Peak Discharge and Soil Loss Variation due to the New Town Development - In the Case of Namak New Town Development Area - (신도시 개발에 따른 첨두유출량과 토양유실량 변화에 관한 연구 -목포시 남악 신도시 개발지를 대상으로-)

  • Woo, Chang-Ho;Cho, Nam-Yul
    • Journal of Environmental Impact Assessment
    • /
    • v.11 no.4
    • /
    • pp.271-280
    • /
    • 2002
  • The purpose of this study is to explore the hydrological impacts and soil loss variation due to the land use change of Namak New Town development area. The analysis of hydrological effects and soil loss variation has been carried out using GIS in this study. In order to estimate the peak runoff volume, the Rational Method which is the most popular technique to predict runoff amounts is used. To estimate the soil loss in the study area, Universal Soil Loss Equation(USLE), which is one of the most comprehensive and useful technique to predict soil erosion is adopted. The result of this study has shown that the peak runoff volume and the total soil loss increase according to the land use change. The peak runoff volume and the total soil loss have been increased about 2 times and about 48 times more than that of pre development. The increasing of the peak runoff volume can be effective erosion, flooding and so on. A careful city planning is the first essential step to minimize the environmental impacts and to construct the ecological city.

Effects of knee flexor isokinetic training on Knee muscles strength and walking speed in hemiplegia (뇌졸중 환자에서 슬관절 굴근의 등속성운동이 슬관절 근력 및 보행에 미치는 영향)

  • Jang, Moon-Heon
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.711-725
    • /
    • 2000
  • The purpose of this study was to determine the effects of knee flexor isokinetic training on the mean peak torque of knee muscles and hamstrings-to-quadriceps ratio(H/Q ratio) in hemiplegia able to walk independently for more than 10 meters, to analyze the effect of torque increasing on functional aspects; fatigability and ambulation times, also. Forty-one adult subjects with hemiplegia secondary to a stroke partipated in this study. All participants were in/out patients at the College of Medicine, Pocheon CHA University, Pundang CHA General Hospital. The patients were allocated to two groups: one group exclusively for isokinetic maximal voluntary knee flexor training at $150^{\circ}$/sec(n=20) and the other exclusively for isokinetic maximal voluntary knee flexor training from $30^{\circ}$/sec to $150^{\circ}$/sec (n=21) gradually. The allocation was performed according to patient age, sex, affected side to minimize imbalance between the two training groups. Training was carried out from February 14th, 2000 to April 15th, 2000. Analysis of the data was done by means of t-test, x2-test, paired t-test, ANOVA, and multiple regression analysis. The results of this study were as follows: 1. There were no significant differences between the two groups in mean peak torque of knee muscles and relative decreases in knee extensor mean peak torque with increased knee flexor velocities before training (P<.05). 2.There was no significant differences between the two groups in the H/Q ratio, and no relative increases with increased knee flexor velocities before training. 3. there were significant changes in mean peak torque in group A after training(P<.05), but no significant differences as the velocity increased 4.there were significant changes in mean peak torque in group B after training(P<.05), but no significant differences as the velocity increased 5.there were no significant differences between the two groups, and no significant differences in mean peak torque increase rate between the groups with increased knee flexor velocities after training 6.H/Q ratio increased with increased knee flexor velocities between the two groups, but not statistically And there was no significant differences between the groups with increased knee flexor velocities 7.After training, Ambulation time and its decreasing rate decreased significantly in group B (P<.05) 8Before and after training, there was no significant differences between the groups in the fatiguability 9. In the multiple regression analysis, mean peak torque increase rate of the knee extensor and flexor were higher in group B than A(P<.05), and significantly higher with increased knee flexor velocities (P<.05) Also, training method influenced on Ambulation times decreases significantly(P<.05). Results indicated that knee flexor isokinetic training was effective to knee extensor and flexor mean peak torque increase in the hemiplegia able to walk independently for more than 10 meters. Therefore, we were able to conclude that gradual training from low to high velocity was more effective in the increase of mean peak torque of knee joint and decrease of Ambulation times than training only at high velocity.

  • PDF

Analysis of Volatile Components of a Chicken Model Food System in Retortable Pouches Using Multivariate Method (다변량 해석을 이용한 레토르트 파우치 계육 모형식품의 휘발성분 분석)

  • Choi, Jun-Bong;Kim, Jung-Hwan;Moon, Tae-Wha
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.1171-1176
    • /
    • 1996
  • The changes in volatiles of the model system were analyzed by GC and GC-MS before and after retorting. The GC data were analyzed statistically by applying the analysis of variance, and 42 peaks were selected at 5% significance level. Multivariate statistical analysis was performed with these 42 peaks as independent variables. Through the stepwise discriminant analysis, 8 peaks, which corresponded to the compounds such as 2-heptanone, cis-3-hexenal, 2-pentyl-furan, 1-methyl-trans-1,2-cyclohexanediol, 2-hexanone, 3-octanone, trans, trans-nona-2,4-dienal and 1-octen-3-ol, were obtained in sequence to distinguish the samples with and without retorting. The principal component analysis of a set of 8 independent variables resulted in 3 principal components which accounted for 96.1% of the variance, while the first principal component (PC 1) explained 76.5% of the total variance. In addition, through the factor analysis of the principal components, the peaks 11, 20 and 21 could be grouped togather in accordance with the direction and the size while the peaks 9, 33 and 39 constituted the second group in the direction.

  • PDF

Assessment of pushover-based method to a building with bidirectional setback

  • Fujii, Kenji
    • Earthquakes and Structures
    • /
    • v.11 no.3
    • /
    • pp.421-443
    • /
    • 2016
  • When conducting seismic assessment of an asymmetric building, it is essential to carry out three-dimensional analysis considering all the possible directions of seismic input. For this purpose, the author proposed a simplified procedure is to predict the largest peak seismic response of an asymmetric building subjected to horizontal bidirectional ground motion acting in an arbitrary angle of incidence in previous study. This simplified procedure has been applied to torsionally stiff (TS) asymmetric buildings with regular elevation. However, the suitability of this procedure to estimate the peak response of an asymmetric building with vertical irregularity, such as an asymmetric building with setback, has not been assessed. In this article, the pushover-based simplified procedure is applied to estimate the peak response of asymmetric buildings with bidirectional setback. Nonlinear dynamic (time-history) analysis of two six-storey asymmetric buildings with bidirectional setback and designed according to strong-column weak beam concept is carried out considering various directions of seismic input, and the results compared with those estimated by the proposed method. The largest peak displacement estimated by the simplified method agrees well with the envelope of the dynamic analysis response. The suitability assessment of the simplified procedure to analysed building models is made as well based on pushover analysis results.

Characterization of an Unconventional MALDI-MS Peak from DHB/pyridine Ionic Liquid Matrices

  • Hong, Jangmi;Kim, Jeongkwon
    • Mass Spectrometry Letters
    • /
    • v.11 no.1
    • /
    • pp.6-9
    • /
    • 2020
  • Matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) analysis of ionic liquid matrices (ILMs) prepared using pyridine and dihydroxybenzoic acid (DHB), such as 2,3-DHB and 2,5-DHB, displayed an unconventional peak at m/z 232.0, which was regarded as [DHB+pyridine-H]+. The peak at m/z 232.0 was not observed from other ILMs prepared using other DHB isomers, such as 2,4-DHB, 2,6-DHB, 3,4-DHB, and 3,5-DHB. Two requirements to observe the peak at m/z 232.0 in a DHB/pyridine ILM are suggested. First, carboxyl and hydroxyl groups must be located ortho to each other. Second, the secondary hydroxyl group must be located at a carbon with a high electron density. Based on these two requirements, a potential mechanism for the generation of the peak at m/z 232.0 is suggested.

Analysis on Current Limiting Characteristics of a Superconducting Fault Current Limiter (SFCL) with a Peak Currnt Limiting Function (피크전류제한 기능을 갖는 초전도한류기의 전류제한 특성분석)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.1
    • /
    • pp.47-51
    • /
    • 2011
  • The superconducting fault current limiter (SFCL) with a peak current limiting function according to the initial fault current with the different amplitudes was suggested. The proposed SFCL, which consists of two limiting components, causes only the first superconducting element among two limiting components to be quenched in case that the initial fault current with the lower peak amplitude happens. On the other hand, the initial fault current with the higher peak amplitude makes both the superconducting elements of two limiting components to be quenched, which contributes to the peak current limiting function of the SFCL. To confirm the fault current limiting operation of the proposed SFCL, the short-circuit tests of the SFCL according to the fault angle were carried out and its effective fault current limiting operations could be discussed.