• Title/Summary/Keyword: Peak reduction

Search Result 1,254, Processing Time 0.028 seconds

Effect of Peak Temperatures on Hydrogen Attack Susceptibility in Simulated Weld Heat Affected Zone of 3Cr-1Mo-V Steel (3Cr-1Mo-V강의 재현 열영향부에서 최고가열온도가 수소침식감수성에 미치는 영향)

  • 김동진;김병훈;공병욱;김정태;권용형;박화순;강정윤
    • Journal of Welding and Joining
    • /
    • v.18 no.2
    • /
    • pp.232-232
    • /
    • 2000
  • The hydrogen attack characteristics of 3Cr-1Mo-V steel as simulated weld heat affected state were studied in this paper. The hydrogen attack susceptibility was evaluated by the ratios of Charpy impact absorbed energy at 0℃($vE_{0HA}$/$vE_{0}$) and reduction of area by tensile test ($RA_{HA}$/RA) before and after exposure to hydrogen at 600℃ under 450kgf/㎠ for 300hr. The values of $vE_{0HA}$/$vE_{0}$ and $RA_{HA}$/RA were aggravated as the peak temperature of the simulated heat affected zone(HAZ) raised. These results were due to the increase of the possession of bubbles along the grain boundaries, which were resulted in the reduction of grain boundary area to be precipitated carbides due to grain coarsening and the carbon dissolved in the martensite-austenite constituent near by the prior austenite grain boundary. The possession ratio of methane bubbles formed along prior austenite grain boundaries were increased with raising the peak temperature. (Received February 22, 2000)

Effect of Peak Temperatures on Hydrogen Attack Susceptibility in Simulated Weld Heat Affected Zone of 3Cr-1Mo-V Steel (3Cr-1Mo-V강의 재현 열영향부에서 최고가열온도가 수소침식감수성에 미치는 영향)

  • 김동진;김병훈;공병욱;김정태;권용형;박화순;강정윤
    • Journal of Welding and Joining
    • /
    • v.18 no.2
    • /
    • pp.105-111
    • /
    • 2000
  • The hydrogen attack characteristics of 3Cr-1Mo-V steel as simulated weld heat affected state were studied in this paper. The hydrogen attack susceptibility was evaluated by the ratios of Charpy impact absorbed energy at 0℃({TEX}$vE_{0} {HA}_/vE_{0}${/TEX}) and reduction of area by tensile test({TEX}$RA_{HA}/RA${/TEX}) before and after exposure to hydrogen at 600℃ under 450kgf/㎠ for 300hr. The values of {TEX}$vE_{0} {HA}_/vE_{0}${/TEX} and {TEX}$RA_{HA}/RA${/TEX} were aggravated as the peak temperature of the simulated heat affected zone(HAZ) raised. These results were due to the increase of the possession of bubbles along the grain boundaries, which were resulted in the reduction of grain boundary area to be precipitated carbides due to grain coarsening and the carbon dissolved in the martensite-austenite constituent near by the prior austenite grain boundary. The possession ratio of methane bubbles formed along prior austenite grain boundaries were increased with raising the peak temperature.

  • PDF

Two Modified Z-Source Inverter Topologies - Solutions to Start-Up Dc-Link Voltage Overshoot and Source Current Ripple

  • Bharatkumar, Dave Heema;Singh, Dheerendra;Bansal, Hari Om
    • Journal of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.1351-1365
    • /
    • 2019
  • This paper proposes two modified Z-source inverter topologies, namely an embedded L-Z-source inverter (EL-ZSI) and a coupled inductor L-Z source inverter (CL-ZSI). The proposed topologies offer a high voltage gain with a reduced passive component count and reduction in source current ripple when compared to conventional ZSI topologies. Additionally, they prevent overshoot in the dc-link voltage by suppressing heavy inrush currents. This feature reduces the transition time to reach the peak value of the dc-link voltage, and reduces the risk of component failure and overrating due to the inrush current. EL-ZSI and CL-ZSI possess all of the inherent advantages of the conventional L-ZSI topology while eliminating its drawbacks. To verify the effectiveness of the proposed topologies, MATLAB/Simulink models and scaled down laboratory prototypes were constructed. Experiments were performed at a low shoot through duty ratio of 0.1 and a modulation index as high as 0.9 to obtain a peak dc-link voltage of 53 V. This paper demonstrates the superiority of the proposed topologies over conventional ZSI topologies through a detailed comparative analysis. Moreover, experimental results verify that the proposed topologies would be advantageous for renewable energy source applications since they provide voltage gain enhancement, inrush current, dc-link voltage overshoot suppression and a reduction of the peak to peak source current ripple.

Mixed Integer Programming (MIP)-based Energy Storage System Scheduling Method for Reducing the Electricity Purchasing Cost in an Urban Railroad System (도시철도 시스템 전기요금 절감을 위한 혼합정수계획법 기반 ESS(에너지저장장치) 스케줄링 기법)

  • Ko, Rakkyung;Kong, Seongbae;Joo, Sung-Kwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.1125-1129
    • /
    • 2015
  • Increasing peak load is one of the major concerns about operation of urban railroad systems. Since ESSs (Energy Storage Systems) have a great potential for shaving the peak load, there has been a growing interest in the use of ESS for peak load reduction. Also, ESS can be optimally scheduled to minimize the electricity purchasing cost under a given ToU (Time-of-Use) tariff by taking advantage of electricity price difference between peak and off-peak time. This paper presents a Mixed Integer Programming (MIP)-based ESS scheduling method to minimize the electricity purchasing cost under a ToU tariff for an urban railroad system.

Characteristics of Negative Peak Wind Pressure acting on Tall Buildings with Step on Wall Surface

  • Yoshida, Akihito;Masuyama, Yuka;Katsumura, Akira
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.4
    • /
    • pp.283-290
    • /
    • 2019
  • Corner cut, corner chamfered or a building shape change are adopted in the design of tall buildings to achieve aerodynamic superiority as well as response reduction. Kikuchi et.al pointed out that large negative peak external pressures can appear near the inside corner of set-back low rise buildings. It is therefore necessary to pay attention to facade design around steps in building surfaces. Peak wind pressures for corner cut or corner chamfered configurations are given in the AIJ code. However, they cannot be applied where there are many variations of vertical and horizontal steps. There has been no previous systematic research on peak wind pressures around steps in building surfaces. In this study, detailed phenomenon of peak wind pressures around steps in buildings are investigated focusing on vertical and horizontal distances from the building's corner.

PAPR Reduction Method Using SLM-based WHT and DSI (SLM 기반 Walsh Hadamard 변환 및 DSI 기법을 이용한 PAPR 저감 기법)

  • Kim Sang-Woo;Kim Namil;Ryu Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.11 s.102
    • /
    • pp.1147-1154
    • /
    • 2005
  • In this paper, we propose some PAPR(Peak to Average Power Ratio) reduction methods using WHT(Walsh Hadamard Transform) to reduce high PAPR generated in OFDM system because of multi carrier modulation. These proposed methods are the methods which has additional PAPR reduction performance without a loss of bandwidth efficiency and a large increment of calculation complexity than common PAPR reduction methods by combining the WHT with some common methods. In this paper, we propose two PAPR reduction methods made by combining a SLM(Selective Mapping) and DSI(Dummy Sequence Insertion) with a WHT. From simulation result, we can find that the PAPR reduction methods using a WHT can get about 1 dB additional PAPR reduction performance than common PAPR reduction methods; they are SLM and DSI. And, because our proposed methods have not only PAPR reduction effect, but also frequency diversity effect, more stabile data transmission is possible in nonlinear HPA and multipath fading channel.

Comparative of Energy-Saving by Green Roof Type on Urban Office Building (도심 오피스건물의 옥상녹화 조성 유형별 건물에너지 절감 비교 연구)

  • Kim, Jeong-Ho;Kwon, Ki-Uk;Joo, Chang-Hun;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.23 no.8
    • /
    • pp.1437-1446
    • /
    • 2014
  • This study, the urban energy used office building green roof type composition of the target by analyze building energy reductions. Green roof is total 6 types(type A~F) were selected, EnergyPlus the energy simulation programs were used. Top floor of green roof types evaluation, the reduction of the cooling peak load type E(1.26%), type D(1.30%), type C(1.37%), type B(1.45%), type F(1.49%), and heating peak load is type D(1.32%), type E(1.40%), type C(1.47%), type F(1.69%), type B(2.13%) order. Annual cooling load of heating load is reduced more than about 1% effect. The heating load reduction ratio for a maximum of 9% respectively. Cooling peak load of the building energy performance evaluation of type F > type B > type C > type D > type E in the order and in the case of peak loads heating type B > type F > type D > type E>type C order. Annual total energy use reduction of 1.07 to 1.22% and earn, type B in the best good. In primary energy use reductions in the presence of a green roof were in the 4249~4876 kWh/yr. Annual $CO_2$ emissions reductions of unapplied type A were analyzed on average 469.78 kg.

Evaluation and Analysis of Scheduling Algorithms for Peak Power Reduction (전력 피크 감소를 위한 스케줄링 알고리즘의 성능 평가 및 분석)

  • Sung, Minyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2777-2783
    • /
    • 2015
  • Peak power reduction is becoming increasingly important not only for grid operators but also for residential users. The scheduling of electric loads tries to reduce the power peak by splitting the power-on period of an electric device into multiple smaller ones and by interleaving the on-periods of every device in a holistic way. This paper analyzes the performance of EDF, LSF, TCBM, and lazy scheduling algorithms and proposes the enhancement schemes. For analysis, we have implemented the scheduling policies in a simulation environment for distributed control systems. Through extensive experiments using real power traces, we discuss their performance characteristics in terms of power deviation, switch count, and temperature violation ratio. To prevent excessive switching, we propose to employ the concept of limited preemptibility and evaluate its effect on performance. It is found that the best performance is achieved when the scheduler capacity is dynamically adjusted to the actual power demand. The experiment results show that, by load scheduling, the probability of having a power deviation greater than 150W is reduced from 21.5% down to 3.2%.

An Adaptive Tone Injection Scheme using Clipping Noise for PAPR Reduction of OFDM Signals (OFDM 신호의 PAPR 감소를 위해 클리핑 잡음을 이용한 적응적 톤 삽입 기법)

  • Yang, Mo-Chan;Shin, Yo-An
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.11C
    • /
    • pp.1076-1084
    • /
    • 2009
  • We propose an ATI (Adaptive Tone Injection) scheme based on clipping noise for PAPR (Peak-to-Average Power Ratio) reduction of OFDM (Orthogonal Frequency Division Multiplexing) signals. The proposed scheme is composed of three steps: clipping, tone selection, and TI procedures. In the first step, the peak samples in the IFFT (Inverse Fast Fourier Transform) outputs are scaled down by clipping. In the second step, the sub-carrier position where the power of the clipping noise is the maximum, is selected. Finally, the generic TI procedure is performed. Simulation results show that the proposed scheme does not require all the possible combinations of the original TI procedures, while maintaining the PAPR reduction performance.

A Bit SLM Scheme for Peak to Average Power Ratio Reduction in OPDM Systems (직교 주파수 분할 다중화 시스템의 최대전력 대 평균전력의 비 감소를 위한 비트 선택사상 기법)

  • Kim, Kyu-Hong;Noh, Hyung-Suk;Heo, Seok-Joong;No, Jong-Seonh;Shin, Dong-Joon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.6C
    • /
    • pp.444-449
    • /
    • 2008
  • Selected mapping is well-known scheme for peak to average power ratio(PAPR) reduction in orthogonal frequency multiplexing(OFDM) systems. In this paper, we proposed a new scheme for generating a set of candidate transmission sequences. In conventional SLM, candidate sequences were generated by rotating the phases of the frequency domain OFDM M-ary symbols but in proposed scheme, candidate sequences are generated by multiplying the m-sequences with data in bit format of OFDM signals. Computer simulation results show that, as compared to the conventional SLM scheme, the proposed approach has better PAPR reduction performance and especially in case of OFDM systems which has small number of subcarriers has better performance than large ones.