• Title/Summary/Keyword: Peak of contrast sensitivity function

Search Result 6, Processing Time 0.021 seconds

Effects of Transmittance of Diffusive Blur on Visual Acuity and Contrast Sensitivity (확산적 흐림의 투과율이 시력과 대비감도에 미치는 영향)

  • Yang, Seok-Jun;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.355-362
    • /
    • 2015
  • Purpose: To investigate the effects of the transmittance of diffusive blurson visual acuity and contrast sensitivity. Methods: Visual acuity and contrast sensitivity were measured by using Optec$^{(R)}$ 6500 in Healthy 30 subjects aged $22.83{\pm}0.50$ (male 13, female 17) who were recruited from university students. Cataract simulator was used as a tool for diffusive blur. Visual acuity and contrast sensitivity were measured with varying the transmittance of diffusive blur in order to simulate progression of cataract and concentration in fog. Results: Visual acuity was reduced proportionally with decreasing the transmittance of the diffusive blur as follows: $VA(T)=1.84{\times}10^{-2}T-0.645$. Contrast sensitivity was decreased in all spatial frequencies. Contrast sensitivity in a high spatial frequency band was a greater effect and was off the normal range of contrast sensitivity. The peak of contrast sensitivity was moved in the direction to low frequency. From an intersection point of contrast sensitivity function, we could calculated the transmittance of the diffusive blur being off the normal range and the shift to peak spatial frequency. The peak of contrast sensitivity function was observed to move from 6 to 3 cpd at transmittance of about 78.70%, the contrast sensitivities for all frequencies at transmittance of about 69.71% were deviated from the normal range. Conclusions: The transmittance of diffusive blur causes a reduction in visual acuity and contrast sensitivity, a deviation of normal range of contrast sensitivity, and a shift of peak contrast sensitivity. Therefore the more attention is required when suffering from cataracts or driving in fog.

Effects of Induced Dioptric Blur on Visual Acuity and Contrast Sensitivity (유발된 광학적 흐림이 시력과 대비감도에 미치는 영향)

  • Kim, Chang-Jin;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.261-270
    • /
    • 2014
  • Purpose: To study the effect of an artificially induced dioptric blur on acuity and contrast sensitivity using the $Optec^{(R)}$ 6500. Methods: Healthy 31 subjects aged $22.90{\pm}1.92$ (male 16, female 15) who were recruited from university students with 6/6 (20/20) or better corrected visual acuity and normal binocularity. They were measured objective and subjective refraction for full correction and dioptric blur using 0.00 ~ +3.00 D (+0.50 D steps) trial lenses and trial frame. They were measured binocularly visual acuity and contrast sensitivity with the $Optec^{(R)}$ 6500 (Stereo Optical Co., Inc., Chicago, Illinois, USA) under day conditions (photopic condition, $85cd/m^2$). Results: The higher dioptric blur, the less distance visual acuity and decrease rate of visual acuity. The higher dioptric blur, the less contrast sensitivity at all frequencies, and the peak of contrast sensitivity was shifted from middle frequency (6 cpd) to low frequency (1.5 cpd). When the visual acuity was best visual acuity to 0.77, there was the peak point at 6 cpd which was normal contrast sensitivity peak point. Conclusions: If the low refractive error is uncorrected or the refractive error is inappropriate, the contrast sensitivity is decreased and the peak point of contrast sensitivity frequency is shifted abnormally though small uncorrected refractive error. So it will be considered that regular eye test and decision of refractive error correction is important.

Changes of Contrast Sensitivity with Decreasing Luminance in Photopic Conditions (명소시 상태에서 휘도 감소에 따른 대비감도 변화)

  • Lee, Eun Jin;Yoon, Moon Joo;Kim, Soo-Hyun;Yang, Gye Tak;Jeong, Ju-Hyun;Kim, Hyun Jung;Kim, Hyun Il;Choi, Eun Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.411-417
    • /
    • 2012
  • Purpose: To investigate changes of contrast sensitivity with decreasing luminance in photopic conditions. Methods: Contrast sensitivities for 63 university students were investigated at 5 different luminance levels using FACT chart. Results: All contrast sensitivities measured were in the normal range. The peak of contrast sensitivity function was observed to move from 6 to 3 cpd between 40 and $10cd/m^2$. From an intersection point of two hypothetical lines related with contrast sensitivity for 6 and 3 cpd, we could evaluated that the peak moved from 6 to 3 cpd at about $25cd/m^2$. When luminance decreases from 120 to $10cd/m^2$, contrast sensitivity loss at 6 cpd was most, while contrast sensitivity at 1.5 cpd changed little. We could evaluate that at luminance of more than $25cd/m^2$ evaluated approximately, contrast sensitivity was high in the following order of spatial frequency: 18< 12<1.5<3<6 cpd, while at luminance of less than about $25cd/m^2$ as follows: 18<12<1.5<6<3 cpd. Contrast sensitivity losses with decreasing luminance were also evaluated using the decrements and decrement rates of contrast sensitivity. The decrement of contrast sensitivity was the greatest at 6 cpd, while the decrement rate was the greatest at 8 cpd. Conclusions: We propose that evaluation methods used in this research may be available as another methods to evaluate the changes of contrast sensitivity.

Contrast Sensitivity as a Function of Spatial Frequency for 12 Year Old Child-Eye (눈의 공간주파수와 대비 민감도 함수(CSF) 특성에 대한 연구)

  • Kim, Yong Geun;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.1
    • /
    • pp.63-68
    • /
    • 1999
  • It was made of a chart by new method to be measured the contrast sensitivity for a spatial frequency, and the mean luminance of a lattice frequency was made to three forms of 25, 50, 75% and let it to be ready a CS value from 0 to $10^3$. As a result of measuring of the CS value for a spatial frequency on a target of 12 year old students, CS value decreased of according to down the average luminance value and also the peak position shift to low spatial frequency. The low visioned person decreased the CS value in side of high frequency or in space of total frequency. By the lattice adaptation, a measured CS value was decreased in circumstance regions of adapted space frequency.

  • PDF

JPEG-based Variable Block-Size Image Compression using CIE La*b* Color Space

  • Kahu, Samruddhi Y.;Bhurchandi, Kishor M.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.10
    • /
    • pp.5056-5078
    • /
    • 2018
  • In this work we propose a compression technique that makes use of linear and perceptually uniform CIE $La^*b^*$ color space in the JPEG image compression framework to improve its performance at lower bitrates. To generate quantization matrices suitable for the linear and perceptually uniform CIE $La^*b^*$ color space, a novel linear Contrast Sensitivity Function (CSF) is used. The compression performance in terms of Compression Ratio (CR) and Peak Signal to Noise Ratio (PSNR), is further improved by utilizing image dependent, variable and non-uniform image sub-blocks generated using a proposed histogram-based merging technique. Experimental results indicate that the proposed linear CSF based quantization technique yields, on an average, 8% increase in CR for the same reconstructed image quality in terms of PSNR as compared to the conventional YCbCr color space. The proposed scheme also outperforms JPEG in terms of CR by an average of 45.01% for the same reconstructed image quality.

Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image (디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.275-283
    • /
    • 2013
  • The patient radiation dose is different depending on selection of Ion chamber when taking Chest PA which using AEC. In this paper, we studied acquiring the best diagnostic images according to selection of Ion chamber on AEC mode as well as minimizing patient radiation dose. Experimental methods were selection of Ion chamber and change of sensitivity under the same conditions as Chest PA projection. At AEC mode, two upper ion chambers sensors and one lower ion chamber sensor were divided into 7 cases according to selection of on/off. after measuring five times respectively, we obtained average value and calculated exposure dose. Image assessment was done with measured Modulation Transfer Function, Peak Signal to Noise Ratio, Root Mean Square, Signal to Noise Ratio, Contrast to Noise Ratio, Mean to Standard deviation Ratio respectively. In exposure assessment results, selection of two upper chambers was the lowest. In resolution assessment results, image of two upper chambers had the second high spatial frequency at sensitivity at 625(High) was 1.343 lp/mm. RMS value of image selecting two upper chambers was low secondly. SNR, CNR, MSR were the high value secondly. As the sensitivity was increased, radiation dose was decreased but better image could be obtained on image quality. In order to obtain the best medical images while minimizing the dose, usage of two upper ion chambers is considered to be clinically useful at sensitivity 625(High).