• Title/Summary/Keyword: Peak interference

Search Result 190, Processing Time 0.023 seconds

Design and Performance Evaluation of the DFT-Spread OFDM Communication System for Phase Noise Compensation and PAPR Reduction (위상 잡음 보상과 PAPR 저감을 고려한 DFT-Spread OFDM 통신 시스템 설계와 성능 평가)

  • Li Ying-Shan;Kim Nam-Il;Kim Sang-Woo;Ryu Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.7 s.110
    • /
    • pp.638-647
    • /
    • 2006
  • Recently, the DFT-Spread OFDM has been studied for the PAPR reduction. However, the DFT-Spread OFDM produces more ICI and SCI problems than OFDM because phase offset mismatch of the DFT spreading code results from the random phase noise in the oscillator. In this paper, at first, phase noise influence on the DFT-Spread OFDM system is theoretically analyzed in terms of the BER performance. Then, the conventional ICI self-cancellation methods are discussed and two kinds of ICI self-cancellation methods are newly proposed. Lastly, a new DFT-Spread OFDM system which selectively adopts the ICI self-cancellation technique is proposed to resolve the interference problem and PAPR reduction simultaneously. Proposednew DFT-Spread OFDM system can minimize performance degradation caused by phase noise, and still maintain the low PAPR property. Among the studied methods, DFT-Spread OFDM with data-conjugate method or newly proposed symmetric data-conjugate method show the significant performance improvements, compared with the DFT-Spread OFDM without ICI self-cancellation schemes. The data-conjugate method is slightly better than symmetric data-conjugate method.

An Optimal Random Carrier Pulse Width Modulation Technique Based on a Genetic Algorithm

  • Xu, Jie;Nie, Zi-Ling;Zhu, Jun-Jie
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.380-388
    • /
    • 2017
  • Since the carrier sequence is not reproducible in a period of the random carrier pulse width modulation (RCPWM) and a higher harmonic spectrum amplitude is likely to affect the quality of the power supply. In addition, electromagnetic interference (EMI) and mechanical vibration will appear. To solve these problems, this paper has proposed an optimal RCPWM based on a genetic algorithm (GA). In the optimal modulation, the range of the random carrier frequency is taken as a constraint and the reciprocal of the maximum harmonic spectrum amplitude is used as a fitness function to decrease the EMI and mechanical vibration caused by the harmonics concentrated at the carrier frequency and its multiples. Since the problems of the hardware make it difficult to use in practical engineering, this paper has presented a hardware system. Simulations and experiments show that the RCPWM is effective. Studies show that the harmonic spectrum is distributed more uniformly in the frequency domain and that there is no obvious peak in the wave spectra. The proposed method is of great value to research on RCPWM and integrated power systems (IPS).

Energy Efficient Cell Management by Flow Scheduling in Ultra Dense Networks

  • Sun, Guolin;Addo, Prince Clement;Wang, Guohui;Liu, Guisong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.9
    • /
    • pp.4108-4122
    • /
    • 2016
  • To address challenges of an unprecedented growth in mobile data traffic, the ultra-dense network deployment is a cost efficient solution to off-load the traffic over other small cells. However, the real traffic is often much lower than the peak-hour traffic and certain small cells are superfluous, which will not only introduce extra energy consumption, but also impose extra interference onto the radio environment. In this paper, an elastic energy efficient cell management scheme is proposed based on flow scheduling among multi-layer ultra-dense cells by a SDN controller. A significant power saving was achieved by a cell-level energy manager. The scheme is elastic for energy saving, adaptive to the dynamic traffic distribution in the office or campus environment. In the end, the performance is evaluated and demonstrated. The results show substantial improvements over the conventional method in terms of the number of active BSs, the handover times, and the switches of BSs.

Optimal Design of Piecewise Linear Companding Transforms for PAPR Reduction in OFDM Systems

  • Mazahir, Sana;Sheikh, Shahzad Amin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.1
    • /
    • pp.200-220
    • /
    • 2016
  • Orthogonal frequency division multiplexing (OFDM) signals suffer from the problem of large peak-to-average power ratio (PAPR) which complicates the design of the analog front-end of the system. Companding is a well-known PAPR reduction technique that reduces the PAPR by transforming the signal amplitude using a deterministic function. In this paper, a novel piecewise linear companding transform is proposed. The design criteria for the proposed transform is developed by investigating the relationships between the compander and decompander's profile and parameters with the system's performance metrics. Using analysis and simulations, we relate the companding parameters with the bit error rate (BER), out-of-band interference (OBI), amount of companding noise, computational complexity and average power. Based on a set of criteria developed thereof, we formulate the design of the proposed transform. The main aim is to preserve the signal's attributes as much as possible for a predetermined amount of PAPR reduction. Simulations are carried out to evaluate and compare the proposed scheme with the existing companding transforms to demonstrate the enhancement in PAPR, BER and OBI performances.

Assay of Nifedipine in the Plasma from Patients with Pulmonary Hypertension

  • Oh, Doo-Man;Johnson, Cary E.;Yong, Chul-Soon;Choi, Yoon-Soo
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.3
    • /
    • pp.1-9
    • /
    • 1994
  • In order to assay the human plasma concentration of nifedipine in patients with bronchopulmonary dysplasia (BPD) and pulmonary hypertension, a modified high performance liquid chromatography (HPLC) method was applied. The retention times for nifedipine and an internal standard (11-ketoprogesterone) were $10.5\;{\pm}\;0.41$ and $13.1\;{\pm}\;0.63$ min, respectively. Absolute recovery from the plasma was $102.9\;{\pm}\;7.07%$. Reproducibility was excellent and variability between the runs was small. There was a negligible degradation during the assay procedure. The calibration curve shows a good linearity in the range of the desired plasma concentrations of nifedipine. A stability test of nifedipine in the human plasma shows 8 and 13% degradation during the storage of 5 and 9 months, respectively. There were no interferences on the HPLC assay with any possible medications for the BPD. The method has been used to monitor the drug concentrations in a patient. The concentration-time curve of a patient after a single oral dose of 0.3 mg/kg shows a double-peak phenomenon that was quite different from the previous report, suggesting non-bolus administration. However the hemodynamic responses were corresponding to the plasma concentration levels of nifedipine.

  • PDF

Wideband Dual-polarized Microstrip Antenna with H-shaped Coupling Slot (H-커플링 슬롯 광대역 이중편파 마이크로스트립 안테나)

  • Kim, Jang Wook;Jeon, Joo Seong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.4
    • /
    • pp.71-79
    • /
    • 2014
  • This paper investigates wideband dual-polarized microstrip antenna with H-shaped coupling slot. These types of antennas are used to prevent deterioration of transmission quality caused by terminal interference or multipath fading, which usually occur when many terminals are used in limited space such as hot-spot zones. The experimental results show that the impedance bandwidth ($SWR{\leq}2$) of 33.98% and the peak gain of 8.58 dBi (at 2.11 GHz) were obtained by the frequency band under 2.7 GHz. The proposed antenna is designed originally for multiple service bands with simple structure and easily be mass-produced for various commercial applications.

The Determination of Dopamine in the Presence of Ascorbic Acid at the Modified Glassy Carbon Electrode with Phytic Acid and Single-Walled Carbon Nanotubes

  • Bae, Si-Ra;Jeong, Hae-Sang;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2363-2368
    • /
    • 2007
  • A glassy carbon electrode (GCE) modified with phytic acid (PA) and single-walled carbon nanotubes (SWNTs) were investigated by voltammetric methods in buffer solution. The PA-SWNTs/GCE-modified electrode demonstrated substantial enhancements in electrochemical sensitivity and selectivity towards dopamine (DA) in the presence of L-ascorbic acid (AA). The PA-SWNTs films promoted the electron transfer reaction of DA, while the PA film, acting as a negatively charged linker, combined with the positively charged DA to induced DA accumulation in the film at pH under 7.4. However, the PA film restrained the electrochemical response of the negatively charged AA due to the electrostatic repulsion. The anodic peak potentials of DA and AA could be separated by electrochemical techniques, and the interferences from AA were effectively eliminated in the DA determination. Linear calibration plots were obtained in the DA concentration range of 0.1-10 μM and the detection limit of the DA oxidation current was determined to be 0.06 μM at a signal-to-noise ratio of 3. The results indicated that the modified electrode is used to determine DA without interference from AA.

A High-Speed White-Light Scanning Interferometer for Bump Inspection of Semiconductor Manufacture (반도체 Bump 검사를 위한 백색광 주사 간섭계의 고속화)

  • Ko, Kuk Won;Sim, Jae Hwan;Kim, Min Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.7
    • /
    • pp.702-708
    • /
    • 2013
  • The white-light scanning interferometer (WSI) is an effective optical measurement system for high-precision industries (e.g., flat-panel display and electronics packaging manufacturers) and semiconductor manufacturing industries. Its major disadvantages include a slow image-capturing speed for interferogram acquisition and a high computational cost for peak-detection on the acquired interferogram. Here, a WSI system is proposed for the semiconductor inspection process. The new imaging acquisition technique uses an 'on-the-fly' imaging system. During the vertical scanning motion of the WSI, interference fringe images are sequentially acquired at a series of pre-defined lens positions, without conventional stepwise motions. To reduce the calculation time, a parallel computing method is used to link multiple personal computers (PCs). Experiments were performed to evaluate the proposed high-speed WSI system.

Integrated Monitoring System of Maglev Guideway based on FBG Sensing System (FBG 센서 기반의 자기부상열차 통합 모니터링 시스템)

  • Chung, Won-Seok;Kang, Dong-Hoon;Yeo, In-Ho;Lee, Jun-S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.761-765
    • /
    • 2008
  • This study presents an effective methodology on integrated monitoring system for a maglev guideway using WDM-based FBG sensors. The measuring quantities include both local and global quantities of the guideway response, such as stains, curvatures, and vertical deflections. The strains are directly measured from multiplexed FBG sensors at various locations of the test bridge followed by curvature calculations based on the plane section assumption. Vertical deflections are then estimated using the Bernoulli beam theory and regression analysis. Frequency contents obtained from the proposed method are compared with those from a conventional accelerometer. Verification tests were conducted on the newly-developed Korean Maglev test track. It has been shown that good agreement between the measured deflection and the estimated deflection is achieved. The difference between the two peak displacements was only 3.5% in maximum and the correlations between data from two sensing systems are overall very good. This confirms that the proposed technique is capable of tracing the dynamic behavior of the maglev guideway with an acceptable accuracy. Furthermore, it is expected that the proposed scheme provides an effective tool for monitoring the behavior of the maglev guideway structures without electro magnetic interference.

  • PDF

Fuzzy Simulation of a Multi-electronic Acupuncture System and Clip-type Pulsimeter Equipped with a Magnetic Sensing Hall Device

  • Hong, You-Sik;Rhee, Jin-Kyu;Kim, Han-Kyu;Son, Il-Ho;Yoon, Woo-Sung;Lee, Nam-Kyu;Park, Do-Young;Kim, Keun-Ho;Kim, Yong-Jin;Khajidmaa, P.;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.255-260
    • /
    • 2014
  • A portable clip-type pulsimeter equipped with a magnetic sensing Hall device has been developed to raise the accuracy of oriental disease diagnosis and therapy by convergence of magnetism and oriental medicine. To improve accuracy and reliability of conventional pulsimeter due to subjective analysis of the pulse wave and measuring position dependency of the arterial pulse sensor, the fuzzy algorithm was applied to analyze the strong- and weak-pulse wave symptom. Optimal time for electronic acupuncture was calculated using fuzzy rules and interference were drawn from objective data in view of pre-treatment. Moreover, the electrical characteristics of the pain parts that respond to acupuncture point were applied in view of post-treatment to propose the scientific pulse wave algorithm and simulation experiment.