• Title/Summary/Keyword: Peak flow

Search Result 1,454, Processing Time 0.034 seconds

O-ring 을 이용한 원주의 저항감소에 관한 실험적 연구 (Drag Reduction of a Circular Cylinder With O-rings)

  • 임희창;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2089-2094
    • /
    • 2003
  • The flow around a circular cylinder was controlled by attaching O-rings to reduce drag force acting on the cylinder. Four experimental models were tested in this study; one smooth cylinder of diameter D (D=60mm) and three cylinders fitted with O-rings of diameters d=0.0167D, 0.05D and 0.067D with pitches of PPD=1D, 0.5D and 0.25D. The drag force, mean velocity and turbulent intensity profiles in the near wake behind the cylinders were measured for Reynolds numbers based on the cylinder diameter in the range of $Re_D=7.8{\times}10^3{\sim}1.2{\times}10^5$. At $Re_D=1.2{\times}10^5$, the cylinder fitted with O-rings of d=0.0167D in a pitch interval of 0.25D shows the maximum drag reduction of about 5.4%, compared with the smooth cylinder. The drag reduction effect of O-rings of d=0.067D is not so high. For O-ring circulars, as the Reynolds number increases, the peak location of turbulence intensity shifts downstream and the peak magnitude is decreased. Flow field around the cylinders was visualized using a smoke-wire technique to see the flow structure qualitatively. The size of vortices and vortex formation region formed behind the O-ring cylinders are smaller, compared with the smooth cylinder.

  • PDF

2단 축류홴과 엇회전식 축류홴의 공력특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Two-Stage and a Counter-Rotating Axial Flow Fan)

  • 조진수;조이상
    • 대한기계학회논문집B
    • /
    • 제25권10호
    • /
    • pp.1281-1292
    • /
    • 2001
  • Experiments were done for the comparison of performance and flow characteristics between a two -stage axial flow fan and a counter-rotating axial flow fan. Each stage of the two -stage axial flow fan used fur the present study has an eight bladed rotor and thirteen slater blades. The front and the rear rotor of the counter - rotating axial flow fan have eight blades each and are driven by coaxial counter ro latins shafts through a gearbox located between the rear rotor and the electric motor. Both of the two axial fan configurations have identical rotor blades and the same operating condition fur the one -to-one comparison of the two. Performance curves of the two configurations were obtained and compared by varying the blade pitch angles and axial gaps between the blade rows. The fan characteristic curves were obtained following the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fa n flow characteristics were measured using a five-hole probe by a non-nulling method. The velocity profiles between the hub and tip of the fans were measured and analyzed at the particular operating condition s of peak efficiency, minimum and maximum pressure coefficients. The peak efficiency of the counter-rotating axial fan was improved about 2% respectively, compared with the two stage axial fan. At the minimum pressure coefficient point of the two stage axial fan, the fan inlet flow patterns show that axial velocity highly decreased in the vicinity of the blade tip region. Also, the reverse flow took place at the blade tip.

홀스타인 착유우의 착유시간, 착유속도 및 착유량에 대한 유전모수 추정 (Genetic Parameters for Milking Duration, Milk Flow and Milk Yield Per Milking in Holstein Dairy Cattle)

  • 안병석;주종철;전병순;박성재;백광수;박수봉
    • Journal of Animal Science and Technology
    • /
    • 제48권4호
    • /
    • pp.487-492
    • /
    • 2006
  • 본 연구는 우군의 일일 유량에 대한 비유형질의 특성을 분석하고자 하였으며 공시된 젖소는 농촌진흥청 축산연구소에서 사육된 착유우로서 2005년 11월부터 2006년 4월까지 1일 2회 착유를 하는 우군의 자료를 이용하였다. 시험축은 하나의 우군으로 동일한 사양조건에 의하여 관리된 종모우 66두를 가지는 착유우 154두에서 수집된 기록 12,561개를 분석하였다. 공시축의 평균유기는 139.7일, 평균산차는 1.9산, 착유당 평균유량 13kg을 나타내었다. 평균 비유속도는 최고 비유속도의 64% 수준으로 측정되었다. 비유지속시간, 최고비유속도, 평균비유속도, 착유당 평균유량에 대하여 오후 착유 보다 오전 착유가 높게 나타났고, 산차간에서는 비유지속시간을 제외하고 산차증가와 함께 증가하는 경향이었다. 비유지속시간, 최고비유속도, 평균비유속도 및 착유당 평균 유량에 대한 유전력은 각 0.49, 0.70, 0.58, 0.36으로 비교적 높게 추정되었다. 한편 비유지속시간과 비유속도간에는 부의 유전상관이, 비유지속시간과 착유당 유량간에는 정의 상관이, 최고비유속도에 대한 평균비유 속도(0.87)와 착유당 유량(0.23)은 정의 상관을 보였고, 평균비유속도와 착유당 유량간(0.30)에도 정의 유전상관을 보였다. 결론적으로 비유속도는 유량과 함께 증가하였으나 비유지속시간과는 부의 관계를 보였으나 보다 의미 있는 유전적 특성을 파악하기 위하여 더 많은 두수를 이용한 연구가 필요할 것으로 사료된다.

마그네트런 스퍼터링법으로 증착한 투명전극용 Al도핑된 ZnO의 공정 분위기에 따른 구조적, 전기적, 광학적 특성비교 (Dependence of the Structural, Electrical, and Optical Properties of Al-doped ZnO Films for Transparent Conductors on the Process Atmosphere in Magnetron Sputtering)

  • 임근빈;이종무
    • 한국재료학회지
    • /
    • 제15권8호
    • /
    • pp.518-520
    • /
    • 2005
  • Effects of the $O_2/Ar$ flow ratio in the sputtering process on the crystallinity, surface roughness, carrier concentration, carrier mobility, and optical properties of Al-doped ZnO thin films deposited on sapphire (001) substrates by RF magnetron sputtering were investigated. XRD spectra showed a preferred orientation along the c-axis and a minimum FWHM of the (002) XRD intensity peak for the $O_2/Ar$ flow ratio of 0.5. The (101)peak also appeared and the degree of preferred orientation decreased as the $O_2/Ar$ flow ratio increased from 0.5 to 1.0. AFM analysis results showed that the surface roughness was lowest at the $O_2/Ar$ flow ratio of 0.5 and tended to increase owing to the increase of the grain size as the $O_2/Ar$ flow ratio increased further. According to the Hall measurement results the carrier concentration and carrier mobility of the fan decreased and thus the resistivity increased as the $O_2/Ar$ flow ratio increased. The transmittance of the ZnO:Al film deposited on the glass substrate was characteristic of a standing wave. The transmittance increased as the $O_2/Ar$ flow ratio in-RF magnetron sputtering increased up to 0.5. Considering the effects of the $O_2/Ar$ flow ratio on the surface roughness, electrical resistivity and transmittance properties of the ZnO:Al film the optimum $O_2/Ar$ flow ratio was 0.5 in the RF magnetron sputter deposition of the ZnO:Al film.

Blood flow velocity in the anterior humeral circumflex artery and tear size can predict synovitis severity in patients with rotator cuff tears

  • Takahiro Machida;Takahiko Hirooka;Akihisa Watanabe;Hinako Katayama;Yuki Matsukubo
    • Clinics in Shoulder and Elbow
    • /
    • 제27권1호
    • /
    • pp.11-17
    • /
    • 2024
  • Background: Rotator cuff tears are often associated with synovitis, but the ability of noninvasive ultrasonography to predict the severity of synovitis remains unclear. We investigated whether ultrasound parameters, namely peak systolic velocity in the anterior humeral circumflex artery and Doppler activity in the glenohumeral joint and subacromial space, reflect synovitis severity. Methods: A total of 54 patients undergoing arthroscopic rotator cuff repair were selected. Doppler ultrasound was used to measure peak systolic velocity in the anterior humeral circumflex artery and Doppler activity in the glenohumeral joint and subacromial space, and these values were compared with the intraoperative synovitis score in univariate and multivariate analyses. Results: Univariate analyses revealed that tear size, peak systolic velocity in the anterior humeral circumflex artery, and Doppler activity in the glenohumeral joint were associated with synovitis in the glenohumeral joint (P=0.02, P<0.001, P=0.02, respectively). In the subacromial space, tear size, peak systolic velocity in the anterior humeral circumflex artery, and Doppler activity in the subacromial space were associated with synovitis severity (P=0.02, P<0.001, P=0.02, respectively). Multivariate analyses indicated that tear size and peak systolic velocity in the anterior humeral circumflex artery were independently associated with synovitis scores in both the glenohumeral joint and the subacromial space (all P<0.05). Conclusions: These findings demonstrate that tear size and peak systolic velocity in the anterior humeral circumflex artery, which can both be measured noninvasively, are useful indicators of synovitis severity.

수술후 폐기능상태 평가를 위한 시각적 상사척도(VAS)의 효용성에 관한 연구 (The Effectiveness of VAS for Evaluation of Pulmonary Condition in Postoperative Patients.)

  • 이영란;김명자
    • 기본간호학회지
    • /
    • 제1권1호
    • /
    • pp.69-76
    • /
    • 1994
  • This study was designed and undertaken to find out the effectiveness of VAS for evaluation of general anesthetic postoperative pulmonary-function. We compared the degree of perceived pulmonary function recovery with peak expiratory flow at postoperative 72 hours of subjects. The subjects of this study were collected 38 patients who had received upper abdominal operation in St. Paul Hospital, Catholic University Medical College, and Kangnam Scared Heart Hospital and Kangdong Scared Heart Hospital, Hallym University. Data collection period was from June 15th, to August 7th, 1992. The degree of pulmonary recovery function was measured with peak expiratory at 72 hours postoperatively. The degree of perceived pulmonary function of the patient was measured with ten points visual analog scale at 72 hours postoperatively. Peak expiratory flow and visual analog score was analyzed with Pearson correlation. Peak expiratory flow was expressed as a ratio of preoperative value. The result was as follows : The recovery of pulmonary function and the degree of perceived pulmonary function of the patient at 72hours postoperatively was revealed high correlation (r=.84). The above result suggested that patients with general anesthetic upper abdominal surgery should evaluate recovery of pulmonary function making use of VAS. We know that VAS is very useful in postoperative patients. We perceived that VAS is to take up a positive attitude of patients. Nurse should furnish the nursing care objectively and scientifically to patients. As VAS was economic and simple, VAS should be adviced for wider application.

  • PDF

Determination of Design Flood Levels for the Tidal Reach of the Han River

  • Jun, Kyungsoo;Li, Li
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.173-173
    • /
    • 2015
  • The flood water level in tidal river is determined by the joint effects of flood discharge and tidal water levels at downstream boundary. Due to the variable tidal boundary conditions, the evaluated design water levels associated with a certain flood event can be significantly different. To avoid determining of design water levels just by a certain tidal boundary condition and remove the influence of variability in boundary condition from the evaluation of design water levels, a probabilistic approach is considered in this study. This study focuses on the development of a method to evaluate the realistic design water levels in tidal river with taking into account the combined effects of river discharge and tidal level. The flood water levels are described by the joint probability of two driving forces, river discharge and tidal water levels. The developed method is applied to determine design water levels for the tidal reach of the Han River. An unsteady flow model is used to simulate the flow in the reach. To determine design water levels associated with a certain flood event, first, possible boundary conditions are obtained by sampling starting times of tidal level time series; then for each tidal boundary condition, corresponding peak water levels along the channel are computed; and finally, design water levels are determined by computing the expectations of the peak water levels. Two types of tides which are composed by different constituents are assumed (one is composed by $M_2$, and the other one is composed by $M_2$ and $M_2$) at downstream boundary, and two flood events with different maximum flood discharges are considered in this study. It is found that (a) the computed design water levels with two assumed tides have no significant difference for a certain flood event, though variability of peak water levels due to the tidal effect is considerably different; (b) tidal effect can reach to the Jamsil submerged weir and the effect is obvious in the downstream reach of the Singok submerged weir; (c) in the tidally affected reach, the variability of peak water levels due to the tidal effect is greater if the maximum flood discharge is smaller.

  • PDF

기체크로마토그래프-질량분석기의 실리콘 분리막 인터페이스의 유용성 연구 (Feasibility study of membrane interface for gas chromatograph-mass spectrometry)

  • 강길선;이동수;이화심;박창준
    • 분석과학
    • /
    • 제21권6호
    • /
    • pp.495-501
    • /
    • 2008
  • GC-MS 의 기존 인터페이스와 새로운 인터페이스의 차이점과 유용성을 판단하기 위하여 Agilent 5973 GC-MS의 capillary direct interface를 떼어내고 GC와 질량분석기 사이에 실리콘 membrane을 장착하여 membrane interface GC-MS의 분석 유용성을 조사하였다. 최대 $4.7m{\ell}/min$ 까지 헬륨 운반기체유량을 올릴 때 질량분석기의 진공도는 거의 영향을 받지 않으며, 피이크끌림 현상이 줄어들고 머무른시간이 줄어드는 빠른 분석을 보였다. Membrane 의 두께를 $127{\mu}m$에서 $75{\mu}m$으로 줄일 때 분리능이 향상 되며, membrane interface의 온도를 올릴 때 분리능과 감도가 향상되었다. 그러나 membrane interface GCMS는 질량/전하 비 73, 147에서 바탕이온이 발생하는 것과 기존의 capillary direct insertion interface보다 낮은 감도와 peak tailing에 의한 낮은 분리능의 문제점을 갖는다.

Clock Scheduling and Cell Library Information Utilization for Power Supply Noise Reduction

  • Kim, Yoo-Seong;Han, Sang-Woo;Kim, Ju-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제9권1호
    • /
    • pp.29-36
    • /
    • 2009
  • Power supply noise is fundamentally caused by large current peaks. Since large current peaks are induced by simultaneous switching of many circuit elements, power supply noise can be minimized by deliberate clock scheduling which utilizes nonzero clock skew. In this paper, nonzero skew clock scheduling is used to avoid the large peak current and consequently reduce power supply noise. While previous approaches require extra characterization efforts to acquire current waveform of a circuit, we approximate it only with existing cell library information to be easily adapted to conventional design flow. A simulated annealing based algorithm is performed, and the peak current values are estimated for feasible clock schedules found by the algorithm. The clock schedule with the minimum peak current is selected for a solution. Experimental results on ISCAS89 benchmark circuits show that the proposed method can effectively reduce the peak current.

Cerebrospinal fluid flow in normal beagle dogs analyzed using magnetic resonance imaging

  • Cho, Hyunju;Kim, Yejin;Hong, Saebyel;Choi, Hojung
    • Journal of Veterinary Science
    • /
    • 제22권1호
    • /
    • pp.2.1-2.10
    • /
    • 2021
  • Background: Diseases related to cerebrospinal fluid flow, such as hydrocephalus, syringomyelia, and Chiari malformation, are often found in small dogs. Although studies in human medicine have revealed a correlation with cerebrospinal fluid flow in these diseases by magnetic resonance imaging, there is little information and no standard data for normal dogs. Objectives: The purpose of this study was to obtain cerebrospinal fluid flow velocity data from the cerebral aqueduct and subarachnoid space at the foramen magnum in healthy beagle dogs. Methods: Six healthy beagle dogs were used in this experimental study. The dogs underwent phase-contrast and time-spatial labeling inversion pulse magnetic resonance imaging. Flow rate variations in the cerebrospinal fluid were observed using sagittal time-spatial labeling inversion pulse images. The pattern and velocity of cerebrospinal fluid flow were assessed using phase-contrast magnetic resonance imaging within the subarachnoid space at the foramen magnum level and the cerebral aqueduct. Results: In the ventral aspect of the subarachnoid space and cerebral aqueduct, the cerebrospinal fluid was characterized by a bidirectional flow throughout the cardiac cycle. The mean ± SD peak velocities through the ventral and dorsal aspects of the subarachnoid space and the cerebral aqueduct were 1.39 ± 0.13, 0.32 ± 0.12, and 0.76 ± 0.43 cm/s, respectively. Conclusions: Noninvasive visualization of cerebrospinal fluid flow movement with magnetic resonance imaging was feasible, and a reference dataset of cerebrospinal fluid flow peak velocities was obtained through the cervical subarachnoid space and cerebral aqueduct in healthy dogs.