• 제목/요약/키워드: Peak expiratory flow

검색결과 133건 처리시간 0.024초

호흡곤란을 동반한 만성호흡기질환 환자에서 정천화담탕이 최고호기유속에 미치는 영향(影響) (The Effect of Jeongcheonhwadam-tang on Peak Expiratory Flow in Chronic Pulmonary Disease Patient with Dyspnea)

  • 허태율;임재형;박동일
    • 대한한방내과학회지
    • /
    • 제26권4호
    • /
    • pp.875-880
    • /
    • 2005
  • Object : Dyspnea is a one of the common symptom in pulmonary disease. Jungchunghwadam-tang was used to treat chronic pulmonary disease patients with dyspnea. Thus in this study we evaluate the effect of Jungchunghwadam-tang on dyspnea. Methods : In this study, ten chronic pulmonary disease patients were treated with Jungchunghwadam-tang. Peak expiratory flow were obtained by peak flow meter. Result : After the treatment, peak expiratory flow was increased significantly compared with before treatment. Percentage of predict peak expiratory flow was also increased significantly compared with before treatment. Conclusion : The result of this study demonstrate that Jungchunghwadam-tang taken for dyspnea on chronic pulmonary disease are effective. Further investigation in well designed follow up study is needed.

  • PDF

뒤시엔느 근 이영양증 환자에서 기능 수준과 측정 자세에 따른 최대호기유량, 1초간노력성호기량 및 최대기침유량의 변화 (Changes in Peak Expiratory Flow, Forced Expiratory Volume in 1 Second and Peak Cough Flow Related to Functional Level and Measurement Position in Patients With Duchenne Muscular Dystrophy)

  • 김기송;신헌석
    • 한국전문물리치료학회지
    • /
    • 제16권3호
    • /
    • pp.1-8
    • /
    • 2009
  • It is important to find the effective position for cough and sputum clearance in respiratory physical therapy. The purpose of this study was to compare the changes in peak expiratory flow (PEF), forced expiratory volume in 1 second ($FEV_1$), and peak cough flow (PCF) related to functional level and measurement position in patients with Duchenne muscular dystrophy. Twenty one subjects were classified into three functional levels, and measurements was undertaken in three different measurement positions (upright sitting, $45^{\circ}$ reclining and supine). Vitalograph PEF/FEV DIARY was used to measure PEF and $FEV_1$, and Ferraris Pocket Peak was used to measure PCF. Mixed two-way analysis of variance and Bonferroni post-hoc test were used for statistical analysis. The results of the study were as follows: 1) Significant main effects for measurement position were found. 2) PEF was the highest in upright sitting, followed by $45^{\circ}$ reclining, and supine in order. 3) $FEV_1$ in upright sitting and $45^{\circ}$ reclining were significantly greater compared with that in supine. 4) PCF in upright sitting and $45^{\circ}$ reclining were significantly greater compared with that in supine. 5) No significant main effects for functional level were found in PEF, $FEV_1$, and PCF. 6) No significant functional level by measurement position interactions were found in PEF, $FEV_1$, and PCF. Therefore, it is concluded that upright sitting and $45^{\circ}$ degree reclining positions are recommended for effective cough and sputum clearance.

  • PDF

목 안정화와 호흡 재교육 운동이 만성 뇌졸중 환자의 목 깊은 굽힘근육의 두께, 노력성 폐활량과 최대 기침 유량에 미치는 효과 (Effects of the Neck Stabilizing Exercise Combined With the Respiratory Reeducation Exercise on Deep Neck Flexor Thickness, Forced Vital Capacity and Peak Cough Flow in Patients With Stroke)

  • 이명효;황보각
    • 한국전문물리치료학회지
    • /
    • 제22권1호
    • /
    • pp.19-29
    • /
    • 2015
  • Impaired respiratory function is common in patients with stroke. The purpose of this study were to investigate the effectiveness of exercises and to assess forced vital capacity and peak cough flow after completion of neck stabilizing and respiratory reeducation exercises (combining diaphragmatic breathing and pursed-lip breathing exercises). The 45 participants were randomly assigned to an experimental group 1 ($n_1=15$), experimental group 2 ($n_2=15$), and a control group ($n_3=15$). All subjects performed conservative physical therapy for 30 minutes. Experimental group 1 undertook the neck stabilizing exercise and the respiratory reeducation exercise. Experimental group 2 undertook the respiratory reeducation exercise. Additional exercise did not exceed 30 minutes, five times a week for six weeks. The subjects were assessed for deep neck flexor thickness and breathing function (forced vital capacity, forced expiratory volume at one second, forced expiratory volume at one second/forced vital capacity, peak expiratory flow, and manual assisted peak cough flow) at pre-post value. The results of this study were as follows. Experimental group 1 showed a significant increase only in deep neck flexor thickness change rate (p<.05). All groups showed significant increases in forced vital capacity, forced expiratory volume at one second, and peak expiratory flow in pre-post measurement (p<.05). Experimental groups 1 and 2 showed an increase in manual assisted peak cough flow in pre-post measurement (p<.05). There was no significant difference between experimental group 1 and experimental group 2, but experimental group 1 improved more than experimental group 2 in respiratory function as a whole. In conclusion, these findings suggest that the neck stabilizing exercise in combination with the respiratory reeducation exercise can improve forced vital capacity and peak cough flow in patients with stroke.

천식 환자에 있어서 최대호기 유속의 자가 모니터링을 이용한 복약지도의 유용성 (Clinical Outcome of Educational Program Using Self-monitoring of Peak Expiratory Flow Rate for Asthma Patients)

  • 이명복;신현택;김선영
    • 한국임상약학회지
    • /
    • 제9권2호
    • /
    • pp.97-102
    • /
    • 1999
  • The effects of pharmacist's intervention for asthma patients using self-monitoring of peak expiratory flow rate in medication teaching model was evaluated for 3 months in improving clinical outcomes including emergency visits, hospitalizations, antibiotics use, symptoms and sleep disturbance. Twenty seven patients were enrolled in study and twenty three patients completed the follow-up schedules. The selected patients were given the pre-designed instruction for medication including appropriate use of medication, metered-dose inhaler(MDI) technique, identifying and controling asthma triggers and recognizing early signs of deterioration. There were significant improvements in clinical outcomes, in terms of emergency visits, hopitalizations, antibiotics use, symptoms and sleep disturbance. There were also significant improvements in the MDI use, environmental control, and medication knowledges. There was a progressive increase in peak expiratory flow rate during the three-month intervention. In conclusion, pharmacist's intervention using self-monitoring of peak expiratory flow rate has a significant impact on improving clinical outcomes in asthma patients.

  • PDF

Peak Flow Meter로 측정한 최대호기류속도(PEF)의 추정정상치 및 가타 환기기능검사와의 상관관계 (The Normal Predicted Value of Peak Expiratory Flow(PEF) Measured by the Peak Flow Meter and Correlation Between PEF and Other Ventilatory Parameters)

  • 김민철;권기범;임동현;송창석;정용석;장태원;유호대;정만홍
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권5호
    • /
    • pp.1000-1011
    • /
    • 1998
  • 연구배경: 기관지 천식 환자들과 만성폐쇄성폐질환의 진단이나 기도폐쇄 정도를 알기 위하여 통상적으로 노력성 호기곡선이나 최대호기류량곡선을 이용한 환기기능검사가 널리 이용되고 있다. 그러나 외래를 방문하는 환자들이나 자가 치료를 하는 환자들의 경과관찰에는 검사의 간편성으로 인해 peak flow meter를 이용한 peak expiratory flow(PEF)가 많이 이용된다. 이 경우 PEF의 변이성이 크기 때문에 절대값이나 증상이 없을 때의 최대값을 기준으로 비교하여 사용하기도 하는데 검사 판정의 객관성은 추정정상치가 가장 높을 것이다. 그러나 현재까지 국내에서는 최대호기류량곡선을 이용한 PEF(FEFmax)의 추정정상치의 보고는 다수 있으나 peak flow meter를 이용한 보고는 아직까지 없었다. 이에 실제 환자들이 스스로 쉽게 측정할 수 있는 PEF의 추정정상치를 산출하고 이 값이 $FEV_1$을 비롯한 다른 환기기능검사를 어느 정도 정확하게 예측할 수 있는 지를 조사 연구하였다. 방 법: 호흡기 증상이나 기왕 병력이 없는 건강한 남자 129명(나이 ; 19-74 세), 여자 125명(나이 ; 18-67세)을 대상으로 외래에서 mini-Wright peak flow meter(Clement Clarke International Ltd. England)를 이용하여 3 회 이상 PEF를 측정하였다. 아울러 Microspiro HI-501 portable spirometer(Chest Co., Japan)로 노력성호기곡선, 최대호기류량곡선을 측정 분석하여 $FEV_1$, FVC, $FEV_1/FVC$, $FEF_{25-75%}$, $FEF_{25%}$, $FEF_{50%}$, $FEF_{75%}$와 FEFmax를 구하여 각각의 추정정상치를 구하였고 PEF의 $FEV_1$ 및 FEFmax에 대한 설명력을 회귀분석을 통해 구하였다. 결 과: PEF(L/min)의 추정정상치는 남자가 -2.45$\times$Age(year) + 1.36 $\times$ Height(cm) + 427였고 ($R^2=0.28$), 여자에서는 -0.96 $\times$ Age(year) + 2.01 $\times$ Height(cm)+129였다($R^2=0.12$). 최대호기류량곡선에서 산출한 FEFmax는 PEF보다 납자에서는 $125{\pm}74.0$(L/min), 여자에서는 $118{\pm}52.2$(L/min) 적었다. PEF로 예측할 수 있는 $FEV_1$(ml)값은 남자에서 5.98 $\times$ PEF(L/min) + 303 이고 ($R^2=0.43$), 여자에서는 4.61 $\times$ PEF(L/min) +291 이었다($R^2=0.33$). 결 론: 건강한 성인 254명(남자 129명, 여자 125명)을 대상으로 peak flow meter로 측정한 PEF의 추정정상치를 연령과 신장을 변수로 하여 구하였다. 여기서 측정한 PEF로 $FEV_1$ 및 FEFmax를 어느 정도 예측할 수 있었다. 그리고 측정기계 및 방법에 따라서 PEF 값이 달라짐을 확인하였는데 이런 점을 유의한다면 PEF의 측정은 향후 환자 진료에 많은 도움이 될 것으로 생각한다.

  • PDF

소형 공기챔버를 센서소자로 사용하는 새로운 호식기류 계측기술 (New Measurement Technique of Expiratory Air Flow Rate Using Miniatured Air Chamber)

  • 김경아;이재헌;김군진;이태수;차은종
    • 센서학회지
    • /
    • 제13권2호
    • /
    • pp.79-84
    • /
    • 2004
  • Asthma is one of the important respiratory diseases requiring home self care usually performed by commercialized peak expiratory flow meter (PEFM). However, this simple device can measure only single parameter, PEF, due to its purely mechanical principle, significantly limiting desease management quality. The present study introduced a new expiratory flow measurement technique by miniatured air expansion chamber easily installed within PEFM. Continuous pressure signal obtained from the chamber demonstrated an accurate quadratic relationship with flow. The volume measurement error was $<{\pm}1%$ well within the American Thoracic Society (ATS) criteria of 3%. Important spirometric parameters of FVC, PEF, and FEF25-75% were all accurately estimated with correlation coefficients > 0.95. The present technique obtains continuous expiratory air flow signal, making possible and convenient to perform spirometric test at home. Electronic interface capability would be also useful for remote asthma management.

Comparison of Leukotriene Receptor Antagonist and Theophylline in Addition to Inhaled Corticosteroid in Adult Asthma: A Meta-Analysis

  • Fang, Huijuan;Wang, Jianmiao;Jin, Di;Cao, Yong;Xu, Yongjian;Xiong, Weining
    • Biomolecules & Therapeutics
    • /
    • 제19권3호
    • /
    • pp.296-301
    • /
    • 2011
  • This meta-analysis was performed to evaluate the difference of the therapeutic effi cacy and adverse effects of leukotriene receptor antagonist and theophylline added to inhaled corticosteroids in adult asthma. Databases were searched for studies published through Nov, 2010. Randomized-controlled trials containing inhaled corticosteroids plus leukotriene receptor antagonist and inhaled corticosteroids plus sustained-release theophylline for asthma therapy were selected. For each report, data were extracted to the outcomes analyzed: mean change in morning peak expiratory flow, mean change in evening peak expiratory flow, mean change in morning forced expiratory volume in 1 sec, mean change in daily short bete2-agonist use, asthma exacerbation and adverse effects. Four assessable trials including 182 asthmatic patients were identified. Inhaled corticosteroids plus leukotriene receptor antagonist was superior to inhaled corticosteroids plus theophylline therapy in improving morning peak expiratory flow in asthmatics (mean difference 19.08 [95% confidence interval 13.37-23.79] l/min, p<0.001) and morning forced expiratory volume in 1 sec in asthmatics (mean difference 0.09 [95% confidence interval 0.03-0.14] liter, p=0.001). In evening peak expiratory flow, daily short bete2-agonist use, asthma exacerbation and adverse effects, there was no significant difference between these two therapies (All p>0.05). Our meta-analysis showed that the combination of inhaled corticosteroids plus leukotriene receptor antagonist resulted in more improvement in both peak expiratory flow and forced expiratory volume in 1 sec in the morning than inhaled corticosteroids plus sustained-release theophylline in adult asthmatics. Further trials are necessary to evaluate the dominant effects of the former combination.

비만 소아에서 폐기능 검사와 체성분 분석에 대한 연구 (Pulmonary Function Test and Body Composition Analysis in Obese Children)

  • 신지선;박지혜;김지영;김수정;홍영미
    • Clinical and Experimental Pediatrics
    • /
    • 제48권6호
    • /
    • pp.588-593
    • /
    • 2005
  • 목 적 : 비만아에서 폐기능 검사와 체성분 분석을 시행함으로써 비만이 폐기능과 체성분에 미치는 영향을 밝히고자 하였다. 방 법 : 9세에서 12세의 중등도 이상의 비만 소아 27명과 정상 대조군 20명을 대상으로 체성분(세포내액, 세포외액, 단백질, 무기질, 근육량, 체지방량, 체지방률, 복부지방률)을 분석하였다. 헤모글로빈, 혈당, aspartate aminotransferase(AST), alanine aminotransferase(ALT), 총 콜레스테롤, 혈중 중성지방을 측정하였고 폐기능 검사를 시행하였다. 결 과 : 중등도 이상의 비만 소아에서 peak expiratory flow rate(PEFR)이 정상군에 비해 유의하게 감소하였고, 고도 비만아에서 중등도 비만아보다 세포내액, 단백질, 체지방량, 체지방률, 복부지방률이 유의하게 높았고, peak expiratory flow rate(PEFR)은 고도 비만아에서 유의한 감소를 보였다. peak expiratory flow rate(PEFR)이 비만 소아 중 37.0%에서 감소하였고, forced expiratory flow 25%($FEF_{25}$)와 mid-expiratory flow rate(MEFR)이 14.8%에서, forced expiratory flow 50%($FEF_{50}$)이 11.1%에서, forced expiratory volume in 1st second($FEV_1$)과 FVC가 3.7%에서 감소하였다. 결 론 : 본 연구 대상인 9-12세 소아에서 비만도, 체지방률과 폐기능 측정치와 상관성은 없었지만, 중등도 이상의 비만 소아에서 peak expiratory flow rate(PEFR)이 감소하는 결과를 보이므로 중등도 비만 소아에서 폐기능 검사를 시행하는 것이 좋으며 앞으로 다른 연령군의 비만 소아에서 폐기능 검사에 대한 연구가 필요할 것으로 생각한다.

뇌졸중 환자의 보행능력에 따른 횡격막 두께와 폐기능 분석 (The Analysis on Diaphragm Thickness and Lung Function of Stroke Patients by Walking Ability)

  • 정주현;김난수
    • 대한물리의학회지
    • /
    • 제6권4호
    • /
    • pp.437-445
    • /
    • 2011
  • Purpose : The purpose of this study was to analysis on diaphragm thickness and lung function of stroke patients by walking ability. Methods : We recruited thirty-five adults after stroke(20 male, 15 female) for our study. The subjects were divided into two groups; independent walking group(11 male, 9 female) and non-independent walking group(9 male, 6 female). Assessment of diaphragm thickness was performed using ultrasound in B-mode with a 7.5 MHz linea probe. During the experiment, the subject was seated in the chair. All subjects performed maximal expiratory flow maneuvers using a spirometer in order to determine the forced expiratory volume in 1 second ($FEV_1$), forced vital capacity(FVC), peak expiratory flow(PEF) and $FEV_1$/FVC. Chest expansion was measured with a tape-measure placed circumferentially around the chest wall at the xiphoid process. The collected data analyzed by independent t-test. Results : The diaphragm thickness were significant differences between the independent walking and nonindependent walking group. Values of forced vital capacity, forced expiratory volume at one second, peak expiratory flow in pulmonary function tests were significant differences between the independent walking and non-independent walking group. However, chest expansion were not significant differences in both of the group. Conclusion : This study showed that walking ability of stroke patients have influenced on diaphragm thickness and pulmonary function.

비대면 체간 안정화 운동 프로그램이 근 두께, 체간 근력, 최대 호기량, 정적 균형에 미치는 영향 (Effect of the Untact Trunk Stabilization Exercise Program on Muscle Thickness, Trunk Strength, Maximal Expiratory Flow, and Static Balance)

  • 이동우;정모범
    • 대한물리의학회지
    • /
    • 제16권1호
    • /
    • pp.73-81
    • /
    • 2021
  • PURPOSE: This study examined effects of the untact trunk stabilization exercise program on muscle thickness, trunk strength, maximal expiratory flow, and static balance. METHODS: The subjects were 20 normal adults divided into 10 in the contact exercise group and 10 in the untact exercise group. The trunk stabilization exercise program was conducted for four weeks. The muscle thickness was measured using ultrasound. The maximal expiratory flow was measured using Personal Best Full Range Peak Flow Meter. The static balance was measured through Bio-rescue; and the trunk muscle strength was measured by bending the upper body forward and measuring the time for maintaining the posture. RESULTS: Both contact and untact exercise groups showed significant differences in muscle thickness, muscle strength, maximal expiratory flow, and static balance (p < .05). A significant difference in muscle thickness on ultrasound was observed between the contact and untact exercise groups (p < .05). CONCLUSION: Activation of the transverse abdominal muscle requires accurate instructions of the contact exercise, but despite environmental constraints, the untact exercise program is as effective as the contact exercise for improving muscle strength, maximum expiratory flow, and static balance.