• 제목/요약/키워드: Peak cut power capacity

검색결과 5건 처리시간 0.017초

Utility Interactive PV Systems with Power Shaping Function for Increasing Peak Power Cut Effect

  • Choe, Gyu-Ha;Kim, Hong-Sung;Heo, Hye-Seong;Jeong, Byong-Hwan;Choi, Young-Ho;Kim, Jae-Chul
    • Journal of Power Electronics
    • /
    • 제8권4호
    • /
    • pp.371-380
    • /
    • 2008
  • This paper describes the Utility Interactive PV (UIPV) system which can improve the peak-cut effect by adding an energy storage device of batteries to the power converter. The proposed system has three possible operation modes depending on relative condition of PV output, which can have the power shaping function covering the peak power for 3 hours. A new power circuit and an application algorithm have been applied to the UIPV system which is based on working PV system during a 3-hour peak time. The energy relationship by the proposed system is analyzed theoretically and experimentally. The proposed system is evaluated at the viewpoint of cost and total spacing, which enables the proposed UIPV system to have the reduction of the peak power demand and hence to improve the power capacity of peak cut.

가스냉방 전력대체효과 분석 (Analysis of Electric Power Peak-Cut Effect by Gas Cooling)

  • 정시영;김대환;박기웅
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.208-211
    • /
    • 2009
  • To reduce the peak demand the promotion of gas cooling(absorption chillers and GHPs) is required. In this study the effect of electric power peak-cut has been analyzed using two methods. One is based on monthly LNG consumption data and the other is using the gas cooling capacity installed. Both methods agreed well with each other within the uncertainty of 20%. It was found that the gas cooling had the peak cut effect of 1,500-2,000 MW for recent 5 years (2003 - 2007). The ratio of gas cooling to the whole cooling demand was 12-15%, which is needed to be increased.

  • PDF

교류 고속철도계통에서 BESS의 도입을 위한 전력소비 및 충·방전효과 분석에 관한 연구 (Study on Analysis for Power Consumption and Charge/Discharge Effect with BESS in AC High-Speed Electric Railway System)

  • 전용주;강병욱;채희석;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.20-27
    • /
    • 2014
  • The power consumption pattern of high-speed railway has rarely during night time. But, during service time, the power is consumed irregularly related to train operation. Especially certain unusual about 1-2 days of service time interval to indicate the power consumption is rapidly growing phenomenon, which causes the capacity of the power contract is the annual electricity bill to rise rapidly as the cause. Normally, amount of peak power consumption bill rate at railway substation is over 20% of total electrical bill. Therefore, high-speed railway substation is expected to be considerably larger savings by reducing the peak power of the default charge(demand power).

Quality Assessment of Longissimus and Semitendinosus Muscles from Beef Cattle Subjected to Non-penetrative and Penetrative Percussive Stunning Methods

  • Sazili, A.Q.;Norbaiyah, B.;Zulkifli, I.;Goh, Y.M.;Lotfi, M.;Small, A.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제26권5호
    • /
    • pp.723-731
    • /
    • 2013
  • This study provides a comparative analysis of the effects of pre-slaughter penetrative and non-penetrative stunning and post-slaughter stunning on meat quality attributes in longissimus lumborum (LL) and semitendinosus (ST) muscles in heifers. Ten animals were assigned to each of four treatment groups: i) animals were subjected to conventional Halal slaughter (a clean incision through the structures at the front of the upper neck - the trachea, oesophagus, carotid arteries and jugular veins) and post-cut penetrating mechanical stun within 10 to 20 s of the neck cut (Unstunned; US); ii) high power non-penetrating mechanical stunning followed by the neck cut (HPNP); iii) low power non-penetrating mechanical stunning followed by the neck cut (LPNP); and iv) penetrative stunning using a captive bolt pistol followed by the neck cut (P). For each carcass, muscle samples were removed within 45 min of slaughter, portioned and analysed for pH, cooking loss, water holding capacity (WHC), tenderness (WBS), lipid oxidation (TBARS) and color, over a two week storage period. Stunning did not affect pH and cooking loss. Significant differences in water holding capacity, tenderness, lipid oxidation and color were present at different storage time points. HPNP stunning resulted in lower WHC and color values, particularly lightness ($L^*$), higher TBARS values and peak force values compared with those stunned using LPNP, P and US. These adverse effects on quality were mostly encountered in the ST muscle. In conclusion, the meat quality achieved using P, LPNP and US treatments was comparable, and no treatment stood out as considerably better than another.

PV연계형 ESS의 설치 규모에 따른 수익영향 (Profitability Analysis of ESS with PV Generation)

  • 김창수;최상봉
    • Current Photovoltaic Research
    • /
    • 제8권3호
    • /
    • pp.86-93
    • /
    • 2020
  • The investment in solar and wind generation is rapidly increasing with government's renewable expansion policy and Renewable Portfolio Standard (RPS). Since the large penetration of solar and wind generation increases the variability and uncertainty of supply and demand balance in power system, the government is pursuing the policy of supplying energy storage system (ESS) linked to renewable energy. ESS contributes to the ease of transmission and distribution grid by shifting PV generation from daytime to evening hours. Recently, the declining market price of REC as ESS incentive, policies to cut down incentives and limited ESS storage due to fire events lead to the aggravation of long-term profitability, thus working as a barrier of ESS spreading. In this study, the factors affecting the profit of ESS are analyzed and brief indicators are derived. Based on the indicators, the profit changes are analyzed considering the variation of REC market price and REC incentive weights. Based on the profit change with respect to the increase of ESS capacity, economical ESS installation capacity is suggested.