• Title/Summary/Keyword: Peak body pressure

Search Result 84, Processing Time 0.026 seconds

The comfort evaluation and analysis of the urban rail vehicle (도시철도차량 시트의 안락성 평가 및 분석)

  • Goo, Jae-Kwang;Suh, Woo-Sung;Choi, Se-Hwa
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.222-228
    • /
    • 2007
  • In order to solve the problem of traffic holdups and environmental pollution(contamination), several metropolises are operating the subway and many local government plans hereafter the light rail vehicle operation and it is in the process of preparing. This point of time, it need to evaluate the comfortable characteristic of the seat which is closely connected with passenger and it should be reflected to the product design through the data analysis. The methods of the comfortable characteristic evaluation should be considered to various methods from physical factor to psychological factor. Among these, the most universal and possible quantitative measurement estimate through 'Body pressure measurement system'. From this paper, it was measured the body pressure of the subway seat which is in the process of operating in a domestic and it will be compared and analyzed the material & seat shape, so we evaluated the comfortable characteristic of the short-distance transportation railway vehicle. It was operated the man and woman who belongs in standard shape of Korean, we compared and analyzed the Peak position where the body pressure is visible and body pressure spread out.

  • PDF

Effect of Ignition Delay Time Gap on the Linked Pyrotechnic Thrusters (파이로추력기의 점화시간차 영향)

  • Kim, Ki-Un;Jeon, In-Soo;Ahn, Sung-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.154-159
    • /
    • 2011
  • The effect of the ignition delay time gap is newly studied. The operational characteristics of the linked two pyrotechnic thrusters are affected by the time gap. Although two thrusters are simultaneously ignited, the time at which the pressure starts to rise in each thruster may not be synchronized. The characteristic of the system with the time gap is compared with that of the fully synchronized system without any time gap. Depending upon the magnitude of the time gap, the pressure-time profile and the ballistic performance are different. When two pyrotechnic thrusters have a time gap, the peak pressure of one thruster(in which the pressure is built up earlier) is increased and the other is decreased. As the time gap is increased, the peak pressure is converged into the maximum pressure. This maximum pressure can be obtained when only one thruster is activated. Because the maximum pressure is bounded, it is predicted that there isn't any catastrophic failures in the considered system. When the time gap is relatively small, the impulse of the combined force acting on the moving body is almost maintained. But the ballistic performance of the system with a large time gap should be carefully estimated because the reduction of the ballistic performance should not be easily neglected.

A Novel Air-cell Mattress Based on Approximate Anthropometric Model for Preventing Pressure Ulcer

  • Moon, In-Hyuk;Kang, Sung-Jae;Kim, Gyu-Seok;Mun, Mu-Seong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1278-1282
    • /
    • 2005
  • Air mattress is now used widely to prevent the pressure ulcer by reducing the localized pressure peaks. In this paper an air-cell mattress and its pressure control method based on an approximate anthropometric model are presented. The air-cell mattress has eighteen cylindrical air cells made of porous material allowing air leakage to contribute in reducing the development of pressure ulcer by lowering the pressure peak, temperature and humidity. To determine an optimal air-cell pressure appropriate for each user, we divide the parts of the body into four sections such as head, trunk, hip, and leg. Then, the pressure of each section is independently calculated from the weight of each part based on the individual body height and weight and the approximate anthropometric model. Air supply system for the air-cell mattress is implemented by using four electronic solenoid valves and an air compressor, and it is driven by a real-time micro-controller. The experimental results with seven subjects shows that the proposed air-cell mattress is effective for the prevention of the pressure ulcer.

  • PDF

The Immediate Effect of Inspiratory Muscle Training with Whole Body Vibration on Pulmonary Function of Stroke Patients (전신진동이 결합된 흡기근 훈련이 뇌졸중 환자의 폐 기능에 미치는 즉각적인 효과)

  • Park, Si-Hyun;Seo, Dong-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.4
    • /
    • pp.29-37
    • /
    • 2017
  • PURPOSE: This study investigated the immediate effect of inspiratory muscle training with whole-body vibration on the pulmonary function of subacute stroke patients. METHODS: All participants (n=30) were allocated to the following groups: (1) the inspiratory muscle training group with whole-body vibration (n=10), wherein the patients received inspiratory muscle training with whole-body vibration comprising 3minutes of vibration per session and respiratory training of 30 times and 2 sessions for one day. (2) the inspiratory muscle training group with visual feedback (n=10), wherein the patients received inspiratory muscle training with visual feedback. (3) the inspiratory muscle training group (n=10), wherein the patients received inspiratory muscle training. RESULTS: After the experiment, the inspiratory muscle training group with whole-body vibration exhibited significantly higher forced vital capacity, forced expiratory volume at 1 second, peak inspiratory flow rate, maximal inspiratory pressure, and chest expansion (p<.05), compared to the other groups. Inspiratory muscle training group with whole-body vibration had significantly higher peak expiratory flow rate and maximal voluntary ventilation than the other groups (p<.05). CONCLUSION: These results show that pulmonary function, maximal inspiratory pressure, and chest expansion were significantly better in the inspiratory muscle training group with whole-body vibration than in the other groups. Thus, this treatment will help recovery of pulmonary function in stroke patients.

The Influence of Auditory-Feedback Device Using Wearable Air-Pressure Insole on Spatiotemporal Gait Symmetry in Chronic Hemplegia

  • Heo, Ji-Hun;Song, Changho;Jung, Sangwoo
    • Physical Therapy Rehabilitation Science
    • /
    • v.10 no.3
    • /
    • pp.311-319
    • /
    • 2021
  • Objective: To investigate the effect of emphasized initial contact by using a wearable air-pressure insole to provide auditory-feedback with variations of maximum peak pressure (MPP) of the affected side on spatiotemporal gait parameters and gait symmetry of stroke patients Design: A cross-sectional study Methods: Eighteen stroke patients participated in this study. All subjects walked five trials using an air-pressure insole that provides auditory feedback with different thresholds set on the insole. First, subjects walked without any auditory feedback. Then, the MPP threshold on the affected side was set from 70% and increase threshold by 10% after each trial until 100%. They walked three times or more on the gait analyzer for each trial, and the average values were measured. Before starting the experiment, subjects measured body weight, initial gait abilities and affected side MPP without auditory feedback. Results: Temporal and spatial variables were significantly increased in trials with auditory feedback from air-pressure insole except for non-paralyzed single support time and spatial gait symmetry compared to trials without auditory feedback(p<0.05). Among the four different thresholds, the walking speed, unaffected side single support time, affected and unaffected side stride, and affected side step length were greatest at 80% threshold of maximum peak, while affected single support time, temporal gait symmetry, and unaffected step length were greatest at the maximum peak of 100% threshold. Conclusions: These results indicate that auditory feedback gait using air-pressure insoles can be an effective way to improve walking speed, single support time, step length, stride, and temporal gait symmetry in stroke patients.

Studies on Garment Restraint (IV) -Effect of Slacks Restraint on Lower Extremity- (의복의 구속성에 관한 연구 (IV) -슬랙스 착용시의 하지부 압박을 중심으로-)

  • 심부자;최선희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.18 no.3
    • /
    • pp.387-394
    • /
    • 1994
  • Journal of the Korean Society of Clothing and Textiles Vol. 18, No. 3 (1994) p. 387∼394 In this study, the restriction of slacks (blue jean) versus box pleats skirt was investigated, from the view point of peripheral blood flow at the toe according to motion variation and E.M.G. analysis of leg muscles after walking on the flat or going up and down stairways. Besides, the pressure of slacks on the lower extrimity was measured statically and dynamically. The main results were summerized as follows; 1. The clothing pressure applied by slacks was; each one of thigh and lower leg was 18.2 g/ cm2 and 22.1 g/cm2 in upright, 63.4 g/cm2 and 26.6 g/cm2 in sitting on the chair, on both sides of thigh and lower leg 272.0 g/cm2 over in squatting. 2. When the motion starts from upright, the dynamic clothing pressure reach their peak before the motions end. When the motion ends and the body comes to a still condition, the clothing pressure grow lower and indicate a constant value. but when the body starts moving again to return to upright, the pressures once grow higher and go to zero value after reaching the peak. The pressure on the knee show much greater than those on the hip. This can be because these pressures depend on the degree of skin stretching motion and of its curvature. 3. The surface E.M.G. in leg muscles M. rectus femoris and M. gastrocnemius were recoreded. In the case of wearing slacks, two muscles were activated much more than wearing skirt. 4. The peripheral blood flow at the toe by wearing slacks was lower than wearing skirt. Also the case when squatting, the peripheral blood flow at the toe was low.

  • PDF

A Pressure Applied Low-Level Laser Probe to Enhance Laser Photon Density in Soft Tissue (생체조직내 레이저 광 밀도 향상을 위한 압력 인가형 저출력 레이저 프로브)

  • Yeo, Chang-Min;Park, Jung-Hwan;Son, Tae-Yoon;Lee, Yong-Heum;Jung, Byung-Jo
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.18-22
    • /
    • 2009
  • Laser has been widely used in various fields of medicine. Recently, noninvasive low-level laser therapeutic medical devices have been introduced in market. However, low-level laser cannot deliver enough photon density to expect positive therapeutic results in deep tissue layer due to the light scattering property in tissue. In order to overcome the limitation, this study was aimed to develop a negative pressure applied low-level laser probe to optimize laser transmission pattern and therefore, to improve photon density in soft tissue. In order to evaluate the possibility of clinical application of the developed laser probe, ex-vivo experiments were performed with porcine skin samples and laser transmissions were quantitatively measured as a function of tissue compression. The laser probe has an air suction hole to apply negative pressure to skin, a transparent plastic body to observe variations of tissue, and a small metallic optical fiber guide to support the optical fiber when negative pressure was applied. By applying negative pressure to the laser probe, the porcine skin under the metallic optical fiber guide is compressed down and, at the same time, low-level laser is emitted into the skin. Finally, the diffusion images of laser in the sample were acquired by a CCD camera and analyzed. Compared to the peak intensity without the compression, the peak intensity of laser increased about $2{\sim}2.5$ times and FWHM decreased about $1.67{\sim}2.85$ times. In addition, the laser peak intensity was positively and linearly increased as a function of compression. In conclusion, we verified that the developed low-level laser probe can control the photon density in tissue by applying compression, and therefore, its potential for clinical applications.

Analysis of clothing pressure for commercially customized burn patient's medical compression garments for men in their 20s (시판 맞춤형 화상환자 압박복의 의복압 분석 -20대 남성 상의를 대상으로-)

  • Cho, Shin-Hyun
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.21 no.4
    • /
    • pp.55-67
    • /
    • 2019
  • This study analyzed the fabric and product size of the burn patient's custom compression garment and measured the pressure applied by the garment to assess whether proper pressure is being delivered for treatment. The test clothes were presented to the market by body size and commissioned with the same design. The subjects selected four people close to the average body size of men in their 20s determined by 7th Size Korea. The experiment was conducted by wearing a compression suit, performing activities and measuring changes in the pressure of the garment according to changes in posture. The fabric used for the compressive clothing was not ruptured even at 216 kPa, the elasticity recovery rate was measured between 80.5 and 94.5%. The product dimensions of the experimental clothing varied by up to 8cm from brand to brand, requiring the standardization of compression clothing. The experiment showed that four types of compression suit varied in pressure, and the pressure range, excluding the gastric arm (17.9mmHg), was between 2.5-14.1mmHg, which failed to meet the level of pressurization for treatment purposes. The clothing pressure in the chest area dropped when performing movements rather than standing still. This was interpreted to be a result of reduced the adhesion of the compression suit during operation. The peak pressure (31.68mmHg) and the lowest pressure (2.2mmHg) was noted in the scapula, indicating that no pressure was being transmitted on the vertebrae. The pressure of the garment on the right shoulder blade was elevated in a supine position. Because much time is spent laying down, it is necessary for the pattern design to accommodate for the increased clothing pressure on the shoulder blades. Standardization of the level of pressurization for burn patient's custom-made pressure suits for each stage of treatment is urgently required.

Development of Air-cell Mattress for Preventing Pressure Ulcer Using Anthropometric Model (인체계측 모델을 이용한 욕창방지용 공기셀 매트리스의 개발)

  • Kang Sung-Jae;Kim Gyu-Seok;Hong Jung-Hwa;Ryu Je-Cheong;Kim Kyung-Hoon;Mun Mu-Seong;Moon Inhyuk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.7
    • /
    • pp.578-586
    • /
    • 2005
  • Air mattress is now used widely to prevent the pressure ulcer by reducing the localized pressure peaks. The pressure control method based on the anthrophometric model of an air-cell mattress developed in this study is presented. The air-cell mattress has 18 cylindrical air cells made of porous material allowing air leakage. Even though the air leakage can contribute to reducing the development of pressure ulcer by lowering the pressure peak, temperature and humidity, the air pressure changes with time and the desired air-cell pressure has to be determined as an optimal value for each user. To select the desired air-cell pressure, we first divide the parts of the body into four sections such as head, trunk, hip, and leg. Then, the pressure of each section grouped with air-cells is calculated from the weight of each part estimated from the individual height and body weight. Air supply system for the air-cell mattress is implemented by using four electronic solenoid valves and an air compressor, and it is driven by a real-time microcontroller. We experimented with five subjects of the contact pressure on skin. The experimental results show that the proposed air-cell mattress is effective for the prevention of the pressure ulcer.

A Development of Brassiere Prototype for Attaching the Measuring Module of ECG and Body Movement while Sleeping (심전도 및 수면시 체동 측정 모듈 장착을 위한 브래지어 프로토타입 개발)

  • Kweon, Soo Ae;Sohn, Boo-hyun
    • Journal of Fashion Business
    • /
    • v.21 no.2
    • /
    • pp.78-90
    • /
    • 2017
  • In this study, brassiere prototype was developed for attaching the measuring module of ECG measurement and body movement while sleeping. For ECG measurement, textile electrodes was made of stretch fabric containing polyurethane in consideration of elasticity of brassiere band. It was used as a conductive yarn by silver coating on the warp. The textile electrodes was woven with twisted twill to increase the density of conductive yarns. The pressure of the brassiere band was enough to sensing stably the ECG, and the elastic band of the brassiere was designed to be wider than 3cm to install the textile electrodes inside, so that textile electrodes was close fitting to the skin at a constant pressure without lifting. The textile electrodes coated with silicon on rear was attached to brassiere elastic band, and the module was installed with a snap connector to textile electrodes of brassiere band. The module was suitable to monitering ECG measurement of a typical R peak, pulse rate and body movement while sleeping without interfering.