• Title/Summary/Keyword: Peak Sound Pressure

Search Result 57, Processing Time 0.029 seconds

Au Experimental Study on the Aerodynamic Noise by a Circular Jet Impinging on a Plate (평판에 충돌하는 원형분류의 공력소음에 관한 실험적 연구)

  • 이동훈;권영필;한희갑
    • Journal of KSNVE
    • /
    • v.7 no.1
    • /
    • pp.71-79
    • /
    • 1997
  • The objective of this study is to investigate experimentally the effect of surface conditions of the plate on the impinging jet noise. The experimental results about the spectrum, the sound pressure level and the directivity are pressented and discussed in relation with the surface conditions. Regardless of the surface conditions, the pure tones of high level are generated at the same frequency band and the overall sound power level of impinging jets is much higher than that of the free jet. However, the velocity dependence of the sound pressure level and the directivity are different between smooth surfaces and rough surfaces. The dependence of sound pressure level on the jet velocity shows that the smooth surface generates quadrupole-type sound like free jets. However, the perforated or the rough surface radiates sound power exactly proportional to the sixth power of the jet velocity, indicating that the source is fixed dipole type. The directivities of 1/3 octave band sound pressure level for both the free and impinging jet show the peak directivity at 115$^\circ$ upstream, probably due to the refraction associated with velocity gradient.

  • PDF

Design of a Micro-perforated Panel Absorber at High Incident Sound Pressure (높은 입사 음압에서의 미세 천공판을 이용한 흡음 기구의 설계)

  • Park, Soon-Hong;Seo, Sang-Hyun;Jang, Young-Soon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.10
    • /
    • pp.983-990
    • /
    • 2010
  • Reduction of acoustic loads of space launch vehicles can be achieved by acoustic absorbers satisfying strict cleanness requirements. This limited the use of general porous materials and requires non-porous sound absorbers. Micro-perforated panel absorbers(MPPA) is one of promising sound absorbers satisfying the cleanness requirement for launch vehicles. However, its applicability was limited to low sound pressure levels according to the acoustic impedance model of micro-perforated panels. In this paper the applicability of micro-perforated panel absorbers at high incident sound pressure was investigated in experimental ways. The absorption characteristics of a micro-perforated panel absorber was simulated according to its design variables, e.g., minute hole diameters and aperture ratios. It was shown that optimal design can be readily done by using proposed design charts. Experiments were conducted to measure acoustic properties of the designed micro-perforated panel absorbers. The results showed that acoustic resistance increases rapidly as incident sound pressure level does but change of acoustic reactance can be neglected in a practical point of view. This caused the decrease of peak value of absorption coefficient at high incident sound pressure level, but the amount of reduction can be accepted in practice. The major advantage of the micro-perforated panel absorber(wide absorption bandwidth) was still kept at high sound pressure level.

Numerical Investigation on the Characteristics of Flow-Induced Noise in a Centrifugal Blower

  • Lee, Chanyoung;Jeong, Taebin;Ha, Kyoung-Ku;Kang, Shin-Hyoung
    • International Journal of Fluid Machinery and Systems
    • /
    • v.7 no.1
    • /
    • pp.7-15
    • /
    • 2014
  • In the present study, a computational analysis of the flow in a centrifugal blower is carried out to predict a performance and to explain noise characteristics of the blower. Unsteady, 3D Navier-Stokes equations were solved with k-${\varepsilon}$ turbulence model using CFX software. CFD results were compared with the experimental data that is acquired from an experiment conducted with the same blower. The pressure fluctuation in the blower was transformed into the frequency domain by Fourier decomposition to find the relationship between flow behaviors and noise characteristics. Sound pressure level (SPL) which is obtained from wall pressure fluctuation at impeller outlet represents relative overall sound level of the blower well. Sound spectra show that there are some specific peak frequencies at each mass flow rate and it can be explained by flow pattern.

Effect of building volume and opening size on fluctuating internal pressures

  • Ginger, John D.;Holmes, John D.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • v.11 no.5
    • /
    • pp.361-376
    • /
    • 2008
  • This paper considers internal pressure fluctuations for a range of building volumes and dominant wall opening areas. The study recognizes that the air flow in and out of the dominant opening in the envelope generates Helmholtz resonance, which can amplify the internal pressure fluctuations compared to the external pressure, at the opening. Numerical methods were used to estimate fluctuating standard deviation and peak (i.e. design) internal pressures from full-scale measured external pressures. The ratios of standard deviation and peak internal pressures to the external pressures at a dominant windward wall opening of area, AW are presented in terms of the non-dimensional opening size to volume parameter, $S^*=(a_s/\bar{U}_h)^2(A_W^{3/2}/V_{Ie})$ where $a_s$ is the speed of sound, $\bar{U}_h$ is the mean wind speed at the top of the building and $V_{Ie}$ is the effective internal volume. The standard deviation of internal pressure exceeds the external pressures at the opening, for $S^*$ greater than about 0.75, showing increasing amplification with increasing $S^*$. The peak internal pressure can be expected to exceed the peak external pressure at the opening by 10% to 50%, for $S^*$ greater than about 5. A dominant leeward wall opening also produces similar fluctuating internal pressure characteristics.

An Aerodynamic and Acoustic Analysis of the Breathy Voice of Thyroidectomy Patients (갑상선 수술 후 성대마비 환자의 기식 음성에 대한 공기역학적 및 음향적 분석)

  • Kang, Young-Ae;Yoon, Kyu-Chul;Kim, Jae-Ock
    • Phonetics and Speech Sciences
    • /
    • v.4 no.2
    • /
    • pp.95-104
    • /
    • 2012
  • Thyroidectomy patients may have vocal paralysis or paresis, resulting in a breathy voice. The aim of this study was to investigate the aerodynamic and acoustic characteristics of a breathy voice in thyroidectomy patients. Thirty-five subjects who have vocal paralysis after thyroidectomy participated in this study. According to perceptual judgements by three speech pathologists and one phonetic scholar, subjects were divided into two groups: breathy voice group (n = 21) and non-breathy voice group (n = 14). Aerodynamic analysis was conducted by three tasks (Voicing Efficiency, Maximum Sustained Phonation, Vital Capacity) and acoustic analysis was measured during Maximum Sustained Phonation task. The breathy voice group had significantly higher subglottal pressure and more pathological voice characteristics than the non breathy voice group. Showing 94.1% classification accuracy in result logistic regression of aerodynamic analysis, the predictor parameters for breathiness were maximum sound pressure level, sound pressure level range, phonation time of Maximum Sustained Phonation task and Pitch range, peak air pressure, and mean peak air pressure of Voicing Efficiency task. Classification accuracy of acoustic logistic regression was 88.6%, and five frequency perturbation parameters were shown as predictors. Vocal paralysis creates air turbulence at the glottis. It fluctuates frequency-related parameters and increases aspiration in high frequency areas. These changes determine perceptual breathiness.

The Comparison of Aerodynamic Measures in Korean Stop Consonants based on Phonation Types (한국어 파열음의 발성 유형에 따른 공기역학 측정치 비교)

  • Choi, Seong Hee;Choi, Chul-Hee
    • Phonetics and Speech Sciences
    • /
    • v.6 no.4
    • /
    • pp.195-203
    • /
    • 2014
  • The aim of this study was to investigate the effects of phonation types ([+/- aspirated], [+/- fortis]) on aerodynamic measures with Korean bilabial stops. Sixty-three healthy young adults (30 males, 33 females) participated to evaluate the VOEF (Voicing Efficiency) tasks with bilabial stop consonants /$p^h$/, /p/, /p'/ using Phonatory Aerodynamic System (PAS) Model 6600 (Kay PENTAX Corp, Lincoln Park, NJ). All VOEF measures were significantly influenced by phonation types except RANP(pitch range)(p <.01). For sound pressure, maximum SPL, mean SPL, and Mean SPL during Voicing have been shown to be significantly greatest in fortis stop /p'/ than aspirated /$p^h$/ and lenis stop /p/ (p<.001). On the other hand, mean pitch after lenis stop was significantly lower than after aspirated and fortis stops (p<.001). Peak expiratory airflow, Target airflow, and FVC (Expiratory volume) were significantly lowest in fortis stop /p'/ which might be associated with higher aerodynamic resistance while peak air pressure and mean peak air pressure during closure were significantly lower in lenis stop /p/. Additionally, AEFF (Aerodynamic efficiency) was significantly higher in fortis stop /p'/ than lenis stop /p/ as well as aspirated stop /$p^h$/ (p<.001). Thus, sound pressure, airflow parameters, and aerodynamic resistance made crucial roles in distinguishing fortis /p'/ from lenis stop /p/ and aspirated. Additionally, pitch and subglottal air pressure parameters were important aerodynamic characteristics in distinguishing lenis /p/ from fortis /p'/ and aspirated /$p^h$/. Therefore, accurate aspirated /p/ stop consonant should be elicited when collecting the airflow, intraoral pressure related data with patients with voice disorders in order to enhance the reliability and relevance or validity of aerodynamic measures using PAS.

Low Frequency Pass-by Noise for Road Vehicle (도로교통 소음원에 의한 저주파 소음실태)

  • 정성수;서상준;조문재;김용태
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.533-536
    • /
    • 2003
  • The Low frequency(1-200 Hz) noise levels radiated by road traffic were investigated. The results showed that the peak pass-by noise of truck with speed of 60km/h was about 75㏈. For the infra-sound frequency range, the noise was about 65㏈ and it was less value than expected. But the noise level will be increase as increasing the speed. The pass-by noise for train was also measured for comparison. The peak train noise was about 95㏈ and it will be enough noise level for a human body to give nuisance.

  • PDF

The Study of the improvement of the sound quality using the target profile of combustion pressure (목적 연소압 형상을 이용한 음질 개선에 관한 연구)

  • Hwang, C.K.;Min, B.D.;Kim, I.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.649-653
    • /
    • 2006
  • Engine Noise is composed of the mechanical and combustion noise. The contribution of combustion noise is generally bigger than the contribution of the mechanical noise at idle condition in DI diesel engine. That noise usually makes a roughness problem at the fundamental engine order. It is difficult to remove the modulation frequency so we have to directly reduce the combustion noise. The key effect of combustion noise reducing solution is the modification of the combustion pressure profile. It is accomplished by the multiple injection method and we solved the 400Hz combustion noise and improved the sound quality at idle condition in DI diesel engine.

  • PDF

Aerodynamic Analysis of Different Types of Singing Voices (가수 유형별 음성의 공기역학적 분석)

  • Noh, Dong-Woo;Hwang, Bo-Myung;Paik, Eun-A;Jeong, Ok-Ran
    • Speech Sciences
    • /
    • v.8 no.4
    • /
    • pp.131-138
    • /
    • 2001
  • Sound pressure level, subglottic air pressure, vital capacity, adduction/abduction rate, and phonatory efficiency were measured in 19 opera singers, 17 Korean traditional 'Pansori' singers, and 20 non-singers; subjects' mean age was 25.9(SD=7.2) and the singers had been singing professionally for 5-10 years. One-way ANOVA and Scheff$\w'{e}$ post-hoc analysis were used to analyze aerodynamic data and to identify significant differences among groups. Sound pressure level, peak subglottic air pressure, and phonatory efficiency were found to be significantly different among three groups of the subjects. Differences in aerodynamic properties were discussed for their significance in diagnosis and treatment of voice disorders in professional singers.

  • PDF

Characteristics of Piezoelectric Microspeakers according to the Material Properties (물성변화에 따른 압전형 마이크로스피커의 특성)

  • Jeong, Kyong-Shik;Cho, Hee-Chan;Yi, Seung-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.6
    • /
    • pp.556-561
    • /
    • 2008
  • This paper reports the characteristics of piezoelectric microspeakers that are audible in open air with high quality piezoelectric AlN thin film according to the materials properties. When we use a tensile-stressed silicon nitride diaphragm as a supporting layer, the Sound Pressure Level (SPL) is relatively small and constant at low frequency region and shows about 70 dB at 10 kHz. However, in case of a compressively stressed composite diaphragm, the SPL of the fabricated microspeakers shows higher output pressure than those of a tensile-stressed diaphragm. It produces more than 66 dB from 100 Hz to 15 kHz and the highest SPL is about 100 dB at 9.3 kHz with $20V_{peak-to-peak}$, sinusoidal input biases and at 10 mm distances from the fabricated microspeakers to the reference microphone. From the experimental results, it is superior to have a compressively composite diaphragm in order to produce a high SPL in piezoelectric microspeaker.