• Title/Summary/Keyword: Peak Reduction

Search Result 1,244, Processing Time 0.027 seconds

Relationship between plasma asymmetric dimethylarginine and nitric oxide levels afects aerobic exercise training-induced reduction of arterial stifness in middle-aged and older adults

  • Shimomura, Mio;Fujie, Shumpei;Sanada, Kiyoshi;Kajimoto, Hiroki;Hamaoka, Takafumi;Iemitsu, Motoyuki
    • Korean Journal of Exercise Nutrition
    • /
    • v.25 no.1
    • /
    • pp.16-22
    • /
    • 2021
  • [Purpose] Aerobic exercise training (AT) reverses aging-induced deterioration of arterial stiffness via increased arterial nitric oxide (NO) production. Asymmetric dimethylarginine (ADMA), an endogenous inhibitor of NO synthase, was decreased by AT. However, whether AT-induced changes in ADMA levels are related to changes in nitrite/nitrate (NOx) levels remains unclear. Accordingly, we aimed to clarify whether the relationship between plasma ADMA and NOx levels afected the AT-induced reduction of arterial stifness in middle-aged and older adults. [Methods] Thirty-one healthy middle-aged and older male and female subjects (66.4 ± 1.3 years) were randomly divided into two groups: exercise intervention and sedentary controls. Subjects in the training group completed an 8-week AT (60%-70% peak oxygen uptake [${\dot{V}}O_{2peak}$] for 45 min, 3 days/week). [Results] AT signifcantly increased ${\dot{V}}O_{2peak}$ (P < 0.05) and decreased carotid β-stifness (P < 0.01). Moreover, plasma ADMA levels were significantly decreased while plasma NOx levels and NOx/ADMA ratio were significantly increased by AT (P < 0.01). Additionally, no sex diferences in AT-induced changes of circulating ADMA and NOx levels, NOx/ADMA ratio, and carotid β-stifness were observed. Furthermore, the AT-induced increase in circulating ADMA levels was negatively correlated with an increase in circulating NOx levels (r = -0.414, P < 0.05), and the AT-induced increase in NOx/ADMA ratio was negatively correlated with a decrease in carotid β-stifness (r = -0.514, P < 0.01). [Conclusion] These results suggest that the increase in circulating NOx with reduction of ADMA elicited by AT is associated with a decrease in arterial stiffness regardless of sex in middle-aged and older adults.

Economic Evaluation of ESS in Urban Railway Substation for Peak Load Shaving Based on Net Present Value

  • Park, Jong-young;Heo, Jae-Haeng;Shin, Seungkwon;Kim, Hyungchul
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.981-987
    • /
    • 2017
  • In this paper, we estimate the economic benefits of Energy Storage Systems (ESSs) for peak load shaving in an urban railway substation using the annual cost. The annual investment cost of ESSs is estimated using Net Present Value (NPV) and compared with the cost reduction of electricity by the ESS. The optimal capacities of the battery and Power Converting System (PCS) are determined for peak load shaving. The optimal capacity of the ESS and the peak load shaving is determined to maximize the profit by the ESS. The proposed method was applied to real load data in an urban railway substation, and the results show that electric power costs can be reduced. Other aspects of the ESS, such as the lifetime and unit price of the battery, are also investigated economically.

Clock Scheduling and Cell Library Information Utilization for Power Supply Noise Reduction

  • Kim, Yoo-Seong;Han, Sang-Woo;Kim, Ju-Ho
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.1
    • /
    • pp.29-36
    • /
    • 2009
  • Power supply noise is fundamentally caused by large current peaks. Since large current peaks are induced by simultaneous switching of many circuit elements, power supply noise can be minimized by deliberate clock scheduling which utilizes nonzero clock skew. In this paper, nonzero skew clock scheduling is used to avoid the large peak current and consequently reduce power supply noise. While previous approaches require extra characterization efforts to acquire current waveform of a circuit, we approximate it only with existing cell library information to be easily adapted to conventional design flow. A simulated annealing based algorithm is performed, and the peak current values are estimated for feasible clock schedules found by the algorithm. The clock schedule with the minimum peak current is selected for a solution. Experimental results on ISCAS89 benchmark circuits show that the proposed method can effectively reduce the peak current.

Demand Response of Large-Scale General and Industrial Customer using In-House Pricing Model (사내요금제를 활용한 대규모 수용가 수요반응에 관한 연구)

  • Kim, Min-Jeong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1128-1134
    • /
    • 2016
  • Demand response provides customer load reductions based on high market prices or system reliability conditions. One type of demand response, price-based program, induces customers to respond to changes in product rates. However, there are large-scale general and industrial customers that have difficulty changing their energy consumption patterns, even with rate changes, due to their electricity demands being commercial and industrial. This study proposes an in-house pricing model for large-scale general and industrial customers, particularly those with multiple business facilities, for self-regulating demand-side management and cost reduction. The in-house pricing model charges higher rates to customers with lower load factors by employing peak to off-peak ratios in order to reduce maximum demand at each facility. The proposed scheme has been applied to real world and its benefits are demonstrated through an example.

Drag Reduction of a Circular Cylinder With O-rings (O-ring 을 이용한 원주의 저항감소에 관한 실험적 연구)

  • Lim, Hee-Chang;Lee, Sang-Joon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2089-2094
    • /
    • 2003
  • The flow around a circular cylinder was controlled by attaching O-rings to reduce drag force acting on the cylinder. Four experimental models were tested in this study; one smooth cylinder of diameter D (D=60mm) and three cylinders fitted with O-rings of diameters d=0.0167D, 0.05D and 0.067D with pitches of PPD=1D, 0.5D and 0.25D. The drag force, mean velocity and turbulent intensity profiles in the near wake behind the cylinders were measured for Reynolds numbers based on the cylinder diameter in the range of $Re_D=7.8{\times}10^3{\sim}1.2{\times}10^5$. At $Re_D=1.2{\times}10^5$, the cylinder fitted with O-rings of d=0.0167D in a pitch interval of 0.25D shows the maximum drag reduction of about 5.4%, compared with the smooth cylinder. The drag reduction effect of O-rings of d=0.067D is not so high. For O-ring circulars, as the Reynolds number increases, the peak location of turbulence intensity shifts downstream and the peak magnitude is decreased. Flow field around the cylinders was visualized using a smoke-wire technique to see the flow structure qualitatively. The size of vortices and vortex formation region formed behind the O-ring cylinders are smaller, compared with the smooth cylinder.

  • PDF

Drag Reduction of NACA0012 Airfoil with a Flexible Micro-riblet (마이크로 리블렛이 부착된 NACA0012 익형의 항력 감소 연구)

  • Jang Young Gil;Lee Sang Joon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.479-482
    • /
    • 2002
  • Riblets with longitudinal grooves along the streamwise direction have been used as an effective flow control technique for drag reduction. A flexible micro-riblet with v-grooves of peak-to-peak spacing of $300{\mu}m$ was made using a MEMS fabrication process of PDMS replica. The flexible micro-riblet was attached on the whole surface of a NACA0012 airfoil with which grooves are aligned with the streamwise direction. The riblet surface reduces drag coefficient about $7.9{\%}\;at\;U_o=3.3m/s$, however, it increases drag about $8{\%}\;at\;U_o=7.0m/s$, compared with the smooth airfoil without riblets. The near wake has been investigated experimentally far the cases of drag reduction ($U_o\;=\;3.3 m/s$) and drag increase ($U_o\;=\;7 m/s$). Five hundred instantaneous velocity fields were measured for each experimental condition using the cross-correlation PIV velocity field measurement technique. The instantaneous velocity fields were ensemble averaged to get spatial distribution of turbulent statistics such as turbulent kinetic energy. The experimental results were compared with those of a smooth airfoil under the same flow condition. The micro-riblet surface influences the near wake flow structure largely, especially in the region near the body surface

  • PDF

Prototype of a Peak to Average Power Ratio Reduction Scheme in Orthogonal Frequency Division Multiplexing Systems

  • Varahram, Pooria;Ali, Borhanuddin Mohd;Mohammady, Somayeh;Reza, Ahmed Wasif
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.6
    • /
    • pp.2201-2216
    • /
    • 2015
  • Peak to average power ratio (PAPR) is one of the main imperfections in the broadband communication systems with multiple carriers. In this paper, a new crest factor reduction (CFR) scheme based on interleaved phase sequence called Dummy Sequence Insertion Enhanced Partial Transmit Sequence (DSI-EPTS) is proposed which effectively reduces the PAPR while at the same time keeps the total complexity low. Moreover, the prototype of the proposed scheme in field programmable gate array (FPGA) is demonstrated. In DSI-EPTS scheme, a new matrix of phase sequence is defined which leads to a significant reduction in hardware complexity due to its less searching operation to extract the optimum phase sequence. The obtained results show comparable performance with slight difference due to the FPGA constraints. The results show 5 dB reduction in PAPR by applying the DSI-EPTS scheme with low complexity and low power consumption.

Experimental study on tuned liquid damper performance in reducing the seismic response of structures including soil-structure interaction effect

  • Lou, Menglin;Zong, Gang;Niu, Weixin;Chen, Genda;Cheng, Franklin Y.
    • Structural Engineering and Mechanics
    • /
    • v.24 no.3
    • /
    • pp.275-290
    • /
    • 2006
  • In this paper, the performance of a tuned liquid damper (TLD) in suppressing the seismic response of buildings is investigated with shake table testing of a four-story steel frame model that rests on pile foundation. The model tests were performed in three phases with the steel frame structure alone, the soil and pile foundation system, and the soil-foundation-structure system, respectively. The test results from different phases were compared to study the effect of soil-structure interaction on the efficiency of a TLD in reducing the peak response of the structure. The influence of a TLD on the dynamic response of the pile foundation was investigated as well. Three types of earthquake excitations were considered with different frequency characteristics. Test results indicated that TLD can suppress the peak response of the structure up to 20% regardless of the presence of soils. TLD is also effective in reducing the dynamic responses of pile foundation.

Determination of Rhodium by Inverted Catalytic Hydrogen peak as Analytical peak (뒤집힌 촉매수소 전류 봉우리를 이용한 로듐의 정량)

  • Kwon, Young-Soon;Lim, Kyong-Hee
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.269-276
    • /
    • 2003
  • A new type of stripping voltammetry, inverted catalytic stripping voltammetry $IC_tSV$, is introduced. The rhodium-formaldehyde complex in hydrochloric acid gives an inverted catalytic hydrogen peak (reduction current peak during positive-going scan). The characteristics of the inverted peak were studied. By using the peak as analytical peak the detection limit of $1.2{\times}10^{-10}M$ Rh (50s preconcentration) can be reached at the optimal conditions: 0.015% (W/V) HCHO-0.42 M HCl; accumulation potential, -1.1 V; scan rate, 100 mV/s.

Utility Interactive PV Systems with Power Shaping Function for Increasing Peak Power Cut Effect

  • Choe, Gyu-Ha;Kim, Hong-Sung;Heo, Hye-Seong;Jeong, Byong-Hwan;Choi, Young-Ho;Kim, Jae-Chul
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.371-380
    • /
    • 2008
  • This paper describes the Utility Interactive PV (UIPV) system which can improve the peak-cut effect by adding an energy storage device of batteries to the power converter. The proposed system has three possible operation modes depending on relative condition of PV output, which can have the power shaping function covering the peak power for 3 hours. A new power circuit and an application algorithm have been applied to the UIPV system which is based on working PV system during a 3-hour peak time. The energy relationship by the proposed system is analyzed theoretically and experimentally. The proposed system is evaluated at the viewpoint of cost and total spacing, which enables the proposed UIPV system to have the reduction of the peak power demand and hence to improve the power capacity of peak cut.