• 제목/요약/키워드: Patterned glass

검색결과 111건 처리시간 0.03초

Nd:YAG 레이저빔에 의한 PDP 방전셀의 구조 형성 (Formation of PDP cell structure using Nd:YAG laser beam)

  • 안민영;이경철;이홍규;이천
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 디스플레이 광소자 분야
    • /
    • pp.129-132
    • /
    • 2000
  • The PDP(Plasma Display Panel) barrier rib material on the glass substrate was patterned for fabrication of the PDP cell using Nd:YAG laser(1064 nm) which can generate the second(532 nm) and forth(266 nm) harmonic wave by HGM(harmonic generation modules). At a scan speed of 20 ${\mu}m/s$ with the second harmonic wave(532 nm) of Nd:YAG laser, the etching threshold laser fluence of the PDP material was 6.5 $mJ/cm^2$ and a sample(thickness = 180 ${\mu}m$) on the glass substrate was removed clearly at a laser fluence of 19.5 $mJ/cm^2$. In order to increase the throughput of the fabrication we divided a single-beam into multi-beams by using a metal mask between the sample and the focusing lens. As a result, 10 lines of PDP cell were formed by one laser beam scanning at a scan speed of 200 ${\mu}m/s$ and a laser fluence of 2.86 $J/cm^2$.

  • PDF

PDP ITO 패턴유리의 결함 검사시스템 개발 (Development of Defect Inspection System for PDP ITO Patterned Glass)

  • 송준엽;박화영;김현종;정연욱
    • 한국정밀공학회지
    • /
    • 제21권12호
    • /
    • pp.92-99
    • /
    • 2004
  • The formation degree of sustain (ITO pattern) decides quality of PDP (Plasma Display Panel). For this reason, it makes efforts in searching defects more than 30 un as 100%. Now, the existing inspection is dependent upon naked eye or microscope in off-line PDP manufacturing process. In this study developed prototype inspection system of PDP 170 glass is based on line-scan mechanism. Developed system creates information that detects and sorts kinds of defect automatically. Designed inspection technology adopts multi-vision method by slip-beam formation for the minimum of inspection time and detection algorithm is embodied in detection ability of developed system. Designed algorithm had to make good use of kernel matrix that draws up an approach to geometry. A characteristic of defects, as pin hole, substance, protrusion, are extracted from blob analysis method. Defects, as open, short, spots and et al, are distinguished by line type inspection algorithm. In experiment, we could have ensured ability of inspection that can be detected with reliability of up to 95% in about 60 seconds.

프리 패턴한 비정질 실리콘 박막의 two-step RTA 효과 (THE TWO-STEP RAPID THERMAL ANNEALING EFFECT OF THE PREPATTERNED A-SI FILMS)

  • 이민철;박기찬;최권영;한민구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1333-1336
    • /
    • 1998
  • Hydrogenated amorphous silicon(a-Si:H) films which were deposited by plasma enhanced chemical deposition(PECVD) have been recrystallized by the two-step rapid thermal annealing(RTA) employing the halogen lamp. The a-Si:H films evolve hydrogen explosively during the high temperature crystallzation step. In result, the recrystallized polycrystalline silicon(poly-Si) films have poor surface morphology. In order to avoid the hydrogen evolution, the films have undergone the dehydrogenation step prior to the crystallization step Before the RTA process, the active area of thin film transistors (TFT's) was patterned. The prepatterning of the a-Si:H active islands may reduce thermal damage to the glass substrate during the recrystallization. The computer generated simulation shows the heat propagation from the a-Si:H islands into the glass substrate. We have fabricated the poly-Si TFT's on the silicon wafers. The maximun ON/OFF current ratio of the device was over $10^5$.

  • PDF

탄소나노튜브 방출원을 통한 초소형 질량분석기의 이온화 향상 (The Improvement of the Ionization on Micro Mass Spectrometer using Carbon Nanotube Emitter)

  • 송성호;한규성;;이순일;양상식
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.1004-1009
    • /
    • 2009
  • Recently, mass spectrometers are widely used for in-situ chemical analysis. It has rapid response and high sensitivity. In this paper, we present the fabrication and test of a cold cathode emitter for micro mass spectrometer using CNTs(Carbon nano tubes). The CNTs have good mechanical, electrical and chemical characteristics. So they have a long life time and strong robustness. The micro mass spectrometer is composed of the glass substrate and the silicon substrate. The glass substrate is constructed by electrodes for TOF(Time-of-flight) which analyze an ion with mass to charge ratio as ion separator. The silicon substrate is highly doped wafer which is patterned for gate electrode and then 100 11m dry etching to grow the CNTs as the electron emitter. The CNTs are grown by HFCVD(Hot filament chemical vapor deposition) with sputtering the catalyst. We successfully attained to grow the CNTs and to test the characteristics.

Nd:YVO4 Laser Patterning of Various Transparent Conductive Oxide Thin Films on Glass Substrate at a Wavelength of 1,064 nm

  • Wang, Jian-Xun;Kwon, Sang Jik;Cho, Eou Sik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권2호
    • /
    • pp.59-62
    • /
    • 2013
  • At an infra-red (IR) wavelength of 1,064 nm, a diode-pumped Q-switched $Nd:YVO_4$ laser was used for the direct patterning of various transparent conductive oxide (TCO) thin films on glass substrate. With various laser beam conditions, the laser ablation results showed that the indium tin oxide (ITO) film was removed completely. In contrast, zinc oxide (ZnO) film was not etched for any laser beam conditions and indium gallium zinc oxide (IGZO) was only ablated with a low scanning speed. The difference in laser ablation is thought to be due to the crystal structures and the coefficient of thermal expansion (CTE) of ITO, IGZO, and ZnO. The width of the laser-patterned grooves was dependent on the film materials, the repetition rate, and the scanning speed of the laser beam.

A Polymer-based Capacitive Air Flow Sensor with a Readout IC and a Temperature Sensor

  • Kim, Wonhyo;Lee, Hyugman;Lee, Kook-Nyeong;Kim, Kunnyun
    • 센서학회지
    • /
    • 제28권1호
    • /
    • pp.1-6
    • /
    • 2019
  • This paper presents an air flow sensor (AFS) based on a polymer thin film. This AFS primarily consists of a polymer membrane attached to a metal-patterned glass substrate and a temperature-sensing element composed of NiCr. These two components were integrated on a single glass substrate. The AFS measures changes in capacitance caused by deformation of the polymer membrane based on the air flow and simultaneously detects the temperature of the surrounding environment. A readout integrated circuit (ROIC) was also fabricated for signal processing, and an ROIC chip, 1.8 mm by 1.9 mm in size, was packaged with an AFS in the form of a system-in-package module. The total size of the AFS is 1 by 1 cm, and the diameter and thickness of the circular-shaped polymer membrane are 4 mm and $15{\mu}m$, respectively. The rate of change of the capacitance is approximately 11.2% for air flows ranging between 0 and 40 m/s.

반사형 콜레스테릭 칼라필터의 시야각에 따른 광특성 향상에 관한 연구 (Improvement of Optical Characteristics in Viewing Directions in a Reflective Cholesteric Liquid Crystal Color Filter)

  • 김태현;임영진;황성진;이명훈;장원근;이승희
    • 폴리머
    • /
    • 제31권2호
    • /
    • pp.148-152
    • /
    • 2007
  • 콜레스테릭 액정모노머를 이용하여 액정표시장치용 선택반사 칼라필터 원형을 개발하였다. 콜레스테릭 액정은 특정한 기판처리 조건에서 나선(helical twist) 구조를 갖는 액정으로서 피치와 비슷한 크기의 입사 파장을 반사시키는 독특한 선택반사의 광특성을 갖는다. 실험결과 R, G, B의 파장영역을 반사시키는 반구형으로 패턴된 콜레스테릭 반사 필름을 개발하여 그 반사파장의 피크 값을 살펴본 바, 시야각 방향 변화에 따라 적색, 녹색필름은 단파장쪽으로 반사파장 피크가 이동하였으며 청색의 경우 별다른 변화가 없었다. 포토리소그래피를 이용하여 포토레지스트(Photo-resist)를 thermal reflow방식으로 마이크로미터 크기의 반구형의 주기적인 패턴을 얻을 수 있었으며 그 위에 형성된 적색, 녹색, 청색의 필름은 패턴이 없는 경우에 비하여 시야각에 따른 반사파장의 변화가 적음을 육안을 통하여, 그리고 Lab좌표를 통해서 각각 정량적으로 확인할 수 있었다.

유리기판의 친수.소수 상태 변화를 이용한 자기정렬 Ag Pattern 형성 연구 (Self Assembled Patterns of Ag Using Hydrophobic and Hydrophilic Surface Characteristics of Glass)

  • 추병권;최정수;김건정;이선희;박규창;장진
    • 한국진공학회지
    • /
    • 제15권4호
    • /
    • pp.354-359
    • /
    • 2006
  • 일반적인 포토리소그래피를 사용하지 않고 마이크로미터 혹은 나노미터 단위의 패턴형성을 위한 연구가 최근 많은 연구그룹에 의해 진행되고 있다. 본 실험에서는 패턴이 형성된 polydimelthylsiloxane (PDMS) 몰드를 octadecyltrichlorosilane (OTS) 용액에 dipping 하여 PDMS 표변에 OTS 단분자막을 형성하고 micro contact printing (${\mu}-CP$) 방법으로 OTS 단분자 막을 유리기판 표면위로 전사하였다. 전사된 OTS 단분자막은 친수성 유리기판 위에서 소수성 표면특성을 갖게 하며, 친수성은 용액 속에 dipping 하였을 때 소수성 표면 위에는 코팅되지 않도록 한 이 방법을 이용하여 유리기판 위에 Ag 패턴을 형성하였다. 또한, 세척직후 친수성 표면 특성을 보이는 유리기판의 시간에 따른 접촉각 측정을 통해 표면에너지의 변화를 분석하였다.

박막태양전지의 광포획 기술 현황 (Current Status in Light Trapping Technique for Thin Film Silicon Solar Cells)

  • 박형식;신명훈;안시현;김선보;봉성재;;;이준신
    • Current Photovoltaic Research
    • /
    • 제2권3호
    • /
    • pp.95-102
    • /
    • 2014
  • Light trapping techniques can change the propagation direction of incident light and keep the light longer in the absorption layers of solar cells to enhance the power conversion efficiency. In thin film silicon (Si) solar cells, the thickness of absorption layer is generally not enough to absorb entire available photons because of short carrier life time, and light induced degradation effect, which can be compensated by the light trapping techniques. These techniques have been adopted as textured transparent conduction oxide (TCO) layers randomly or periodically textured, intermediate reflection layers of tandem and triple junction, and glass substrates etched by various patterning methods. We reviewed the light trapping techniques for thin film Si solar cells and mainly focused on the commercially available techniques applicable to textured TCO on patterned glass substrates. We described the characterization methods representing the light trapping effects, texturing of TCO and showed the results of multi-scale textured TCO on etched glass substrates. These methods can be used tandem and triple thin film Si solar cells to enhance photo-current and power conversion efficiency of long term stability.

Comparative Quantification of Contractile Force of Cardiac Muscle Using a Micro-mechanical Force Sensing System

  • Ryu, Seok-Chang;Park, Suk-Ho;Kim, Deok-Ho;Kim, Byung-Kyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1179-1182
    • /
    • 2005
  • To facilitate the cell based robot research, we presented a micro-mechanical force measurement system for the biological muscle actuators, which utilize glucose as a power source for potential application in a human body or blood vessels. The system is composed of a micro-manipulator, a force transducer with a glass probe, a signal processor, an inverted microscope and video recoding system. Using this measurement system, the contractile force and frequency of the cardiac myocytes were measured in real time and the magnitude of the contractile force of each cardiac myocyte on a different condition was compared. From the quantitative experimental results, we estimated that the force of cardiac myocytes is about $20{\sim}40\;{\mu}$N, and showed that there is difference between the control cells and the micro-patterned cells.

  • PDF