• Title/Summary/Keyword: Patients Value

Search Result 4,225, Processing Time 0.031 seconds

A study of lower facial change according to facial type when virtually vertical dimension increases (가상적 수직 교합 고경 증가 시 안모의 유형에 따른 하안모 변화에 관한 연구)

  • Kim, Nam-Woo;Lee, Gung-Chol;Moon, Cheol-Hyun;Bae, Jung-Yoon;Kim, Ji-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the effect of increased vertical dimension of occlusion on lower facial changes by facial type. Materials and methods: Lateral cephalograms from 261 patients were obtained and classified by sagittal (Class I, II, and III) and vertical (hypodivergent, normodivergent, and hyperdivergent) facial patterns. Retrusive displacement of soft tissue Pogonion and downward displacement of soft tissue Menton were measured in each group after 2 mm of vertical dimension of occlusion was increased at the lower central incisor using a virtual simulation program. The ratio of both displacements was calculated in all groups. The statistical analysis was done by 2-way ANOVA and Post hoc was done by Tukey test (5% level of significance). Results: Retrusive displacement of soft tissue Pogonion in Class III group was statistically different compared to Class I and II, and in vertical facial groups all 3 groups were significantly different (P<.05). Downward displacement of soft tissue Menton showed statistically significant difference between all sagittal groups and vertical groups (P<.05). The ratio of both displacements showed statistically significant difference in all sagittal groups and vertical groups (P<.05), and Class II hyperdivergent group had the highest value. Conclusion: Lower facial change was statically significant according to the facial type when vertical dimension of occlusion increased. Class II hyperdivergent facial type showed the highest ratio after increase in vertical dimension of occlusion.

Comparison of Results Between Immediate Fixation Group and Delayed Reconstruction Group in Displaced Mid-shaft Fractures of the Clavicle (쇄골 전위성 간부 골절에서 조기 고정술 군과 지연 재건술 군 간의 결과 비교)

  • Kim, Doo-Sub;Rah, Jung-Ho;Yoon, Yeo-Seung;Lee, Chang-Ho
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.1
    • /
    • pp.61-66
    • /
    • 2009
  • Purpose: Several authors have reported excellent results of delayed reconstruction of non-union & malunion in displaced mid-shaft fractures of the clavicle and these results were equal to that of immediate fixation. But direct comparison between these treatments is rare. We evaluated the results between the immediate fixation group and delayed reconstruction group for treating displaced mid-shaft fractures of the clavicle. Materials and Methods: We studied the results of 18 cases with immediate fixation of displaced mid-shaft fractures of the clavicle and 15 cases with delayed reconstruction of non-union & malunion after conservative management, and these cases were seen from March 2000 to February, 2006. The final postoperative outcome was analyzed according to the clinical outcomes with using the Constant score and the radiological findings of bony union. Results: The constant score was low in the delayed reconstruction group compare to that of the immediate fixation group (p value=0.045). For the pain score & the activities of daily living score, a statistically significant difference was seen between the two groups (p<0.05), but not for the range of motion score & the power score (p>0.05). Radiological findings of bony union were seen for both groups at an average of 8.8 weeks for the immediate fixation group and at an average of 9.8 weeks for the delayed reconstruction group. Conclusion: Though the delayed reconstruction group was shown good clinical and radiological results, the immediate fixation group had a significantly better pain score, a better activities of daily living score and a better Constant score. It is important to choose the initial treatment option for displaced mid-shaft fractures of the clavicle after sufficient explanation to patients about the merits and demerits between these two treatment options.

Evaluation on the radiation exposure from activated wedge filter (10MV 이상 고에너지 사용시 wedge filler의 방사화가 작업환경에 미치는 영향평가)

  • Lee HwaJung;Kim DaeYoung;Kim WonTaek;Lee KangHyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.69-79
    • /
    • 2004
  • In the process of photon treatments, linear accelerators with energies higher than 10 MV produce neutrons through the (${\gamma}$, n) interactions with the composite materials of the linac head md these materials further produce the induced radiations. We investigate the possible risks from these induced radiations especially in the wedge filters to the radiation workers. Wedge filters are used to modify the isodose profiles in the radiation treatment using the linear accelerator and always be handled by the radiation workers. For the background radiation, we measured the radiation in both the waiting room and the outside of the building for two hospitals, S and H. The results of S hospital were $0.11\;{\mu}Sv/hr$ and $0.10\;{\mu}Sv/hr$ for waiting room and outside respectively, and in the case of H hospital, they were $0.12\;{\mu}Sv/hr$ and $0.11\;{\mu}Sv/hr$. Using a survey meter, we measured the radiation from wedge filters inserted in 10 MV and 15 MV Siemens linear accelerators. The time series measurements were done in ${\sim}1$ minutes after exposure of 5 Gy of monitor units for the field size of $25{\times}25cm^2$. The starting value of 10 MV machine was about $3.26\;{\mu}Sv/hr$, which was three times higher than that of 10 MV. The measured radiation was from $^{28}Al$ and $^{53}Fe$ with a half life of 3.5 min. If the treatment patients are $20{\sim}50$ per day and the number of process of wedge filter change per patient is one or two, the annual dose equivalent is $0.08{\sim}0.4\;mSv$ for 10 MV, and $0.27{\sim}1.36\;mSv$ for 15 MV, which are in the range of dose equivalent limits of radiation workers.

  • PDF

Usability of Urinary Reagent Strips in Diagnosis of Meningitis (뇌수막염의 진단에서 뇨검사 시험지를 이용한 뇌척수액 검사의 유용성)

  • Jeong, Jin Yeong;Park, Sang Kyu
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.2
    • /
    • pp.265-270
    • /
    • 1997
  • Purpose: Rapid diagnosis and prompt treatment remain the cornerstone of management of patients with meningitis. Examination of cerebrospinal fluid(CSF) for glucose, protein, cells, and organisms is necessary for accurate diagnosis, but in many parts of the world facilities do not exist to do so. We tested CSF samples from 69 children with suspected meningitis with urinary reagent strips and analyzed the results to know the usability of urinary reagent strips in diagnosis of meningitis. Methods: 69 CSF samples obtained from children with suspected meningitis were analysed. Each sample was divided into two; one was sent to the laboratory for routine diagnostic evaluation, and the other was tested with the reagent strip(Combur10 Test M). Laboratory values of CSF glucose, protein, and leucocytes for each CSF sample were plotted against the corresponding reagent-strip category. Results: There was good agreement between the dipstick and laboratory values for CSF protein and cell count but not for glucose. Conclusion: Rapid diagnosis of meningitis could be made with three component of the Combur10 test strip. It is easy to do and would be of particular value to those working in parts of the world where no laboratory facilities exist.

  • PDF

Prognostic Value of Day 3 Inhibin-B on Assisted Reproductive Technology Outcome (보조 생식술 결과에 있어서 기저혈중 Inhibin-B의 예후인자로서의 유용성)

  • Bai, Sang-Wook;Kim, Jin-Young;Lee, Kyung-Sool;Won, Jong-Gun;Lee, Yong-Joo;Yi, Ji-Won;Chang, Kyung-Hwan;Lee, Byung-Seok;Park, Ki-Hyun;Cho, Dong-Jae;Song, Chan-Ho
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.2
    • /
    • pp.217-223
    • /
    • 1997
  • This study was performed to determine if women with day 3 serum inhibin-B concentrations <45pg/ml (conversion factor to SI unit, 1.00) demonstrate a poor response to ovulation induction and assisted reproductive technology outcome to women with inhibin-B${\ge}45pg$/ml, independant of day 3 FSH, E2 and patient age. From Jan 1996 to Dec 1996, 16 volunteers patients who underwent 25 IVF cycles with luteal phase GnRH agonist suppression and HMG stimulation were allocated to the study group. We evaluated day 3 serum inhibin-B, FSH, E2, peak E2, cancellation rate per initiated cycle (%) and clinical pregnancy rate per initiated cycle (%) according to the above two groups and independent of patient age, day 3 FSH, day 3 E2 and all of above combined. Women with day 3 serum inhibin-B${\ge}45pg$/ml demonstrated higher average day 3 inhibin-B level, clinical pregnancy rate per initiated cycle ($20.3{\pm}2.5$ pg/ml vs $80.9{\pm}5.0$ pg/ml, p<0.05; 24.8% vs 8.5%, p<0.05) and lower day 3 FSH level, cancellation rate per initiated cycle ($6.9{\pm}0.3$ mIU/ml vs $8.5{\pm}0.5$ mIU/ml, p<0.05; 1.5% vs 9.0%, p<0.05). Women with day 3 serum inhibin${\ge}45pg$/ml and age<40 year demonstrated higher pregnancy rate per initiated cycle (28.2% vs 7.4%, p<0.05) and lows. day 3 FSH level, cancellation rate per initiated cycle ($6.9{\pm}0.5$ mIU/ml vs $8.2{\pm}0.7$ mIU/ml, p<0.05; 1.0% vs 9.0%, p<0.05). Women with day 3 serum inhibin${\ge}45pg$/ml and day 3 FSH<15mIU/ml demonstrated higher pregnancy rate per initiated cycle (33.5% vs 9.5%, p<0.05) and lower day 3 FSH level, cancellation rate per initiated cycle ($7.7{\pm}0.2$ mIU/ml vs $8.5{\pm}0.5$ mIU/ml, p<0.05; 1.5% vs 10.0%, p<0.05). Women with day 3 serum inhibin${\ge}45pg$/ml and day 3 E2<50pg/ml demonstrated higher pregnancy rate per initiated cycle (30.0% vs 9.5%, p<0.05) and lower cancellation rate per initiated cycle (1.5% vs 9.5%, p<0.05). Women with day 3 serum inhibin${\ge}45pg$/ml, age<40 year, day 3 FSH<15mIU/ml and day 3 E2<50pg/ml demonstrated higher pregnancy rate per initiated cycle (30.0% vs 10.8%, p<0.05) and lower day 3 FSH level, cancellation rate per initiated cycle ($6.8{\pm}0.6$ mIU/ml vs $8.4{\pm}0.9$ mIU/ml, p<0.05; 1.5% vs 7.8%, p<0.05). Therefore women with low day 3 serum inhibin-B concentrations demonstrate a poorer response to ovulation induction and are less likely to conceive a clinical pregnancy though ART relative to women with high day 3 inhibin-B and day 3 serum inhibin-B, in addition to a day 3 FSH, E2 and patient age, appears helpful in prediction in IVF-ET outcome.

  • PDF

Study on Volume Measurement of Cerebral Infarct using SVD and the Bayesian Algorithm (SVD와 Bayesian 알고리즘을 이용한 뇌경색 부피 측정에 관한 연구)

  • Kim, Do-Hun;Lee, Hyo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.591-602
    • /
    • 2021
  • Acute ischemic stroke(AIS) should be diagnosed within a few hours of onset of cerebral infarction symptoms using diagnostic radiology. In this study, we evaluated the clinical usefulness of SVD and the Bayesian algorithm to measure the volume of cerebral infarction using computed tomography perfusion(CTP) imaging and magnetic resonance diffusion-weighted imaging(MR DWI). We retrospectively included 50 patients (male : female = 33 : 17) who visited the emergency department with symptoms of AIS from September 2017 to September 2020. The cerebral infarct volume measured by SVD and the Bayesian algorithm was analyzed using the Wilcoxon signed rank test and expressed as a median value and an interquartile range of 25 - 75 %. The core volume measured by SVD and the Bayesian algorithm using was CTP imaging was 18.07 (7.76 - 33.98) cc and 47.3 (23.76 - 79.11) cc, respectively, while the penumbra volume was 140.24 (117.8 - 176.89) cc and 105.05 (72.52 - 141.98) cc, respectively. The mismatch ratio was 7.56 % (4.36 - 15.26 %) and 2.08 % (1.68 - 2.77 %) for SVD and the Bayesian algorithm, respectively, and all the measured values had statistically significant differences (p < 0.05). Spearman's correlation analysis showed that the correlation coefficient of the cerebral infarct volume measured by the Bayesian algorithm using CTP imaging and MR DWI was higher than that of the cerebral infarct volume measured by SVD using CTP imaging and MR DWI (r = 0.915 vs. r = 0.763 ; p < 0.01). Furthermore, the results of the Bland Altman plot analysis demonstrated that the slope of the scatter plot of the cerebral infarct volume measured by the Bayesian algorithm using CTP imaging and MR DWI was more steady than that of the cerebral infarct volume measured by SVD using CTP imaging and MR DWI (y = -0.065 vs. y = -0.749), indicating that the Bayesian algorithm was more reliable than SVD. In conclusion, the Bayesian algorithm is more accurate than SVD in measuring cerebral infarct volume. Therefore, it can be useful in clinical utility.

Evaluation of Image Quality using SE-EPI and SSH-TSE Techniques in MRDWI (자기공명확산강조영상에서 SE-EPI 와 SSH-TSE 기법을 이용한 영상의 질 평가)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.991-998
    • /
    • 2021
  • The purpose of this study is to investigate the image quality of the SE-EPI and SSH-TSE technique for MR DWI. Datum were analyzed for 35 PACS transmission datum(Normal part: 12 males, 13 females, Cerebral Infarction: 10(5males and 5females), and average age 68±7.32), randomly selected patients who underwent MRDWI tests. The equipment used was Ingenia CX 3.0T, SSH_TSE and SE-EPI pulse sequence and 32 Ch. head coil were used for data acquisition. Image evaluation was performed on the paired t-test and Wilcoxon tests, and was considered significant when the p value was 0.05 or less. As a result of quantitative analysis of SNR for DWI images, the mean and standard deviation values of 4 parts (WM, GM, BG, Cerebellum) in ADC (s/mm2), Diffusion b=0, 1000 images were higher in SE-EPI techniques(ADC: 120.50 ± 40, b=0: 54.50 ± 35.91, b=1000: 91.61 ± 36.63) than in SSH-TSE techniques(ADC: 99.69 ± 31.10, b=0: 43.52 ± 25.00 , b=1000: 60.74 ± 24.85)(p<0.05). The CNR values for GM-WM, BG-WM sites were also higher in SE-EPI technique (ADC: 116.08 ± 43.30, b=0:27.23 ± 09.10, b=1000: 78.50 ± 16.56) than in SSH-TSE(ADC: 101.08 ± 36.81, b=0: 23.96 ± 07.79 , b=1000: 74.30 ± 14.22). As a visual evaluation of observers, ghost artifact, magnetic susceptibility artifacts and overall image quality for SE-TSE and SSH-TSE all yielded high results from SSH-TSE techniques(ADC:3.6 ± 0.1, 2.8 ± 0.2, b=0: 4.3 ± 0.3, 3.4 ± 0.1 b=1000: 4.3 ± 0.2, 3.5 ± 0.2, p=0.000). In conclusion, the SE-EPI technique obtained an superiority in SNR and CNR measurements using SSH-TSE, SE-EPI. In the qualitative analysis, the SSH-TSE pulse sequence was obtained a high result according to the pulse sequence characteristics.

Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant (하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향)

  • Baek, Yeon-Wha;Kim, Bongju;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2018
  • Purpose: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). Materials and Methods: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III $active^{(R)}$ long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III $active^{(R)}$ short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. Results: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). Conclusion: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.

Comparison of Doses of Single Scan PBS and Layered Rescanning PBS Using Moving Phantom in Proton Therapy (양성자 치료에서 Moving Phantom을 이용한 Single Scan PBS와 Layered Rescanning PBS의 선량비교)

  • Kim, Kyeong Tae;Kim, Seon Yeong;Kim, Dae Woong;Kim, Jae Won;Park, Ji Yeon;Jeon, Sang Min
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose : We apply the Layered Rescanning PBS designed to complement the Pencil Beam Scanning(PBS), which is vulnerable to moving organs with the Moving Phantom, and compare the homogeneity with the single scan PBS. Methods and materials: Matrix X (IBA, Belgium) and Moving Phantom (standard imaging, USA) were used. A dose of 200 cGy was measured in the AP direction on a hypothetical tumor $10{\times}10{\times}5cm$. The plan type was planned as 4 kinds of sinlge scan PBS, rescan number 4, 8, 12 times. Were measured three times for each types. During the measurement, the respiratory cycle of the Moving Phantom was generally set to 4 seconds per cycle, and the movement radius in the S-I direction was set to 2 cm. In addition, beam on time was measured. Results : The mean values of $D_{max}$ in the PTV were $246.47{\pm}18.8cGy$, $223.43{\pm}8.92cGy$, and $222.47{\pm}7.7cGy$, $213.9{\pm}6.11cGy$ and the mean values of $D_{min}$ were $165.53{\pm}4.32cGy$, $173.13{\pm}11.94cGy$, $184.13{\pm}8.04cGy$, $182.67{\pm}4.38cGy$ and the mean values of $D_{mean}$ $192.77{\pm}6.98cGy$, $196.7{\pm}4.01cGy$, $198.17{\pm}4.96cGy$, $195.77{\pm}3.15cGy$ respectively. As the number of rescanning increased, the Homogeneity Index converged to 1. The beam on time was measured as 2:15, 3:15, 4:30, 5:37 on average. In the measurement process, in the low dose layer of the MU, the problem was found that it was not rescanned as many times as the set number of rescan. Conclusions : In the treatment of tumors with long-term movements, the application of layered rescanning PBS showed a more uniform dose distribution than single scan PBS. And as the number of rescan increase, the distribution of homogeneity is uniform. Compared with single scan plan and 12 rescan plan, HI value was improved by 0.32. Further studies are expected to be applicable to patients who can not be treated with respiratory synchronous radiation therapy.

Study on the Breast Tissue Uptake according to Body Temperature on Molecular Breast Imaging (Molecular Breast Imaging 검사 시 체온 변화에 따른 유방 섭취율에 관한 고찰)

  • Kim, Ji Hyun;Baek, Song Ee;Oh, Shin Hyun;Ham, Jun Cheol;Kang, Chun Goo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.20-24
    • /
    • 2019
  • Purpose Molecular Breast Imaging (MBI) scan is used in nuclear medicine, for which $^{99m}Tc-sestaMIBI$ is administered by intravenous injection. However, the breast uptake rate of $^{99m}Tc-sestaMIBI$ is less than 1% of the total dose administered, relying on blood flow conditions of organs. The purpose of this study is to evaluate the impact of changes to body temperature on the uptake of $^{99m}Tc-sestaMIBI$ in breast tissue. Materials and Methods We investigated 30 breast cancer patients who performed more than one follow-up MBI scan. All scans were acquired by Discovery 750B (Genral Electric Healthcare, USA). $^{99m}Tc-sestaMIBI$ injected with 740 MBq (20 mCi), after 60 minutes, gained bilateral breast CC (CranioCaudal), MLO (Medio Lateral Oblique) View. The follow-up examination was then classified into 15 body temperature control group and 15 body temperature non-control group, and gained breast image in the same way as before. The breast uptake rate was analyzed in the MLO View of the opposite side of the lesion, and blind images were evaluated. Results The breast uptake rate increased by 30.31% in the body temperature control group and it was statistically significant(P<0.05), and 0.96% in the body temperature non-control group, and it was not statistically significant(P=0.955). There was a significant difference in the uptake rate between the body temperature control and the non-control group of P value of 0.01. Evaluation of blind images showed significant results in terms of the quality of the images. Conclusion Increased breast tissue uptake was observed when the subject was kept warm. When the body temperature was raised after injection, dilation of the peripheral blood vessels can be achieved. As a result, the blood flow became smooth and the breast uptake rate increased. In addition, an increase in breast tissue uptake will improve the quality of images.