• Title/Summary/Keyword: Patient rooms

Search Result 119, Processing Time 0.025 seconds

Effect of Patient Safety Culture and Patient Safety Competence on Safety Nursing Activity among Nurses working in Anesthetic and Recovery Rooms (마취·회복실 간호사의 환자안전문화와 환자안전역량이 안전간호활동에 미치는 영향)

  • Kim, Jin Joo;Jung, Hyang Mi
    • Journal of Korean Clinical Nursing Research
    • /
    • v.26 no.2
    • /
    • pp.164-174
    • /
    • 2020
  • Purpose: This study was to investigate the relationships among patient safety culture, safety competence and safety nursing activity among nurses in anesthetic and recovery rooms, and to identify the factors contributing to safety nursing activity. Methods: A descriptive correlational study was conducted. Participants were 156 nurses from 13 hospitals. Data were collected from February 11 to March 15th, 2019, and analyzed using descriptive statistics, t-test, Mann-Whitney U test, one-way ANOVA, Pearson's correlation and multiple regression analysis with SPSS statistics 24.0 Program. Results: Safety nursing activity was significantly different in relation to nurses' level of education, position at work, clinical career, clinical career at anesthetic and recovery rooms, and work experience in patient safety. Safety nursing activity demonstrated a significant positive correlation with patient safety culture and patient safety competence. Factors contributing to safety nursing activity were patient safety knowledge, skill and attitude, clinical career, clinical career at anesthetic and recovery rooms, and the patient safety improvement system which explained 57.0% of total variance of safety nursing activity. Conclusion: To improve safety nursing activities at anesthetic and recovery rooms, it is necessary to develop patient safety programs with enhanced knowledge, skill and attitude to take patient safety as a top priority.

A Study on the Environmental Improvement of Multi-bed rooms in Hospital (병원의 다인병실 환경개선에 관한 연구)

  • Yu, Young-Min
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.11 no.1
    • /
    • pp.7-14
    • /
    • 2005
  • The existing six-bed patient rooms, general type of multiple-bed rooms in Korea causes many problems for the amenity of patients. We should reconsider their inconvenience carefully and try to provide the right to keep their privacy and enjoy amenity. The number of patients of multi-bed rooms is very critical point to improve the environmental condition of the patient rooms. So This paper aims to provide the possibilities of four-bed rooms through the comparison and analysis of six and four-bed room for planning and design.

  • PDF

Users' Evaluation of Interior Design Features of Patients Rooms in Geriatric Hospital - From the perspectives of Nurses and Care-Givers - (노인요양병원 입원실의 실내디자인 특성에 대한 사용자 평가 - 간호사와 간병인 및 보호자를 대상으로 -)

  • Oh, Chan-Ohk
    • Korean Institute of Interior Design Journal
    • /
    • v.23 no.2
    • /
    • pp.182-192
    • /
    • 2014
  • Demands for geriatric hospital have increased in an era of rapidly aging population. Most of aged patients tend to stay in institutions for long terms. This means that the patient rooms of geriatric hospital should be given different considerations from those of normal hospital in designing interior features. They should be a homelike places for the aged patients and designed to take care of specific needs of the aged. However, most of geriatric hospitals are designed with little attention to such point. They appear almost same to normal ones. This study attempts to examine how users evaluate patients' rooms. The users are nurses, care-givers and family members of aged patients in six geriatric hospitals in Busan. They rated 12 features of patient rooms from 0 point to 100 points and described reasons why they rated in that way. Also, the walk-through was done for these six hospitals. 12 features are sizes of patient rooms, sizes and fixtures of bathrooms, sizes and locations of windows, bed layout, numbers and types of chairs, sizes and types of closet, lighting, color scheme, finishes of floor and wall, and interior design tone. Followings are findings : The users evaluated patients' rooms relatively positive. However, extra chairs for visitors, closet in patients rooms and storage in bathroom, and sizes of patients rooms and bathrooms were evaluated relatively negative.

A Study on the Space Program of Ward applying to 4 Patient Bedroom in Provincial Medical Center (공공의료원의 4인병실 적용에 따른 병동부 스페이스 프로그램에 관한 연구)

  • Kim, Khilchae;Lee, Hyunjin;Kwun, Joonbum
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.2
    • /
    • pp.67-73
    • /
    • 2015
  • Purpose: This study examines areal composition of ward applying to 4 bedroom in provincial medical center. Methods: The existing five-bed patient rooms, general type of multiple-bed rooms in Korea causes many problems for the amenity of patients. We should reconsider their inconvenience carefully and try to provide the right to keep their privacy and enjoy amenity. The number of patients of multi-bed rooms is very critical point to improve the environmental condition of the patient rooms. This study separate 5 bedroom group and 4 bedroom group. Net area from space program was surveyed and analyzed. Results: The result of this study can be summarized into two points. The first one is that Group-4(4 bedroom) ward has more 23% patient's area and -23% convenience area than Group-5(5 bedroom). The second one is that Group-4 has more single bedroom and Group-5 has more dayroom. Implications: Consideration Should be taken into account for the effective bedroom composition and allocation in ward. This Study hopefully may serve as a stepping stone for the standard design of space program in ward.

A Study on Gender Difference in Assessing Emotional Design Characteristics of General Hospital's Wards (사용자 성별에 따른 종합병원 병동부 감성디자인 특성 평가에 관한 연구)

  • Son, Yeorym;Hwang, Yeonsook
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.18 no.4
    • /
    • pp.17-27
    • /
    • 2012
  • Purpose: This research was for understanding the attitudinal difference by gender towards emotional design through questionnaire survey with female and male inpatients on environmental characteristics of wards in general hospitals. Methods: The survey was conducted by questioning inpatients at two general hospitals on the importance rating on emotional design elements of patient rooms, lounges, and hallways. Eighty questionnaires were returned and used for data analyses through SPSS windows version 15.0 statistic package program. Results: 1) In general, female patients considered emotional design of wards as more important than male patients and the most outstanding difference was indicated for patient rooms among patient rooms, lounges, and hallways. For patient rooms the comfortability index was rated as the most important to both female and male inpatient groups, and for lounges and hallways the safety index was evaluated as the most important to both gender groups. 2)For lounges, while male patients rated 'prevention of infection' important among safety relating items, women considered 'accident prevention' more important. It is inferred that female patients have more safety needs and anxiety about physical injury or accidents than male ones do. Implications: It is considered that there need to be further succeeding in-depth studies, e.g. research interviews with inpatient;s family members or other caregivers as well as patients themselves.

Noise and Room Acoustic Conditions in a Tertiary Referral Hospital, Seoul National University Hospital

  • Cho, Wan-Ho;Jeong, Cheol-Ho;Chang, Ji-Ho;Lee, Seong-Hyun;Park, Moo Kyun;Suh, Myung-Whan;Han, Jae Joon
    • Journal of Audiology & Otology
    • /
    • v.23 no.2
    • /
    • pp.76-82
    • /
    • 2019
  • Background and Objectives: Noise levels and room acoustic parameters at a tertiary referral hospital, Seoul National University Hospital (SNUH) in Korea, are investigated. Materials and Methods: Through a questionnaire, acoustically problematic rooms are identified. Noise levels in emergency rooms (ERs) and intensive care units (ICUs) are measured over about three days. Acoustically critical and problematic rooms in the otolaryngology department are measured including examination rooms, operating rooms, nurse stations, receptions, and patient rooms. Results: The A-weighted equivalent noise level, LAeq, ranges from 54 to 56 dBA, which is at least 10 dB lower than the noise levels of 65 to 73 dBA measured in American ERs. In an ICU, the noise level for the first night was 66 dBA, which came down to 56 dBA for the next day. The noise levels during three different ear surgeries vary from 57 to 62 dBA, depending on the use of surgical drills and suctions. The noise levels in a patient room is found to be 47 dBA, while the nurse stations and the receptions have high noise levels up to 64 dBA. The reverberation times in an operation room, examination room, and single patient room are found to be below 0.6 s. Conclusions: At SNUH, the nurse stations and receptions were found to be quite noisy. The ERs were quieter than in the previous studies. The measured reverberation times seemed low enough but some other nurse stations and examination rooms were not satisfactory according to the questionnaire.

Noise and Room Acoustic Conditions in a Tertiary Referral Hospital, Seoul National University Hospital

  • Cho, Wan-Ho;Jeong, Cheol-Ho;Chang, Ji-Ho;Lee, Seong-Hyun;Park, Moo Kyun;Suh, Myung-Whan;Han, Jae Joon
    • Korean Journal of Audiology
    • /
    • v.23 no.2
    • /
    • pp.76-82
    • /
    • 2019
  • Background and Objectives: Noise levels and room acoustic parameters at a tertiary referral hospital, Seoul National University Hospital (SNUH) in Korea, are investigated. Materials and Methods: Through a questionnaire, acoustically problematic rooms are identified. Noise levels in emergency rooms (ERs) and intensive care units (ICUs) are measured over about three days. Acoustically critical and problematic rooms in the otolaryngology department are measured including examination rooms, operating rooms, nurse stations, receptions, and patient rooms. Results: The A-weighted equivalent noise level, LAeq, ranges from 54 to 56 dBA, which is at least 10 dB lower than the noise levels of 65 to 73 dBA measured in American ERs. In an ICU, the noise level for the first night was 66 dBA, which came down to 56 dBA for the next day. The noise levels during three different ear surgeries vary from 57 to 62 dBA, depending on the use of surgical drills and suctions. The noise levels in a patient room is found to be 47 dBA, while the nurse stations and the receptions have high noise levels up to 64 dBA. The reverberation times in an operation room, examination room, and single patient room are found to be below 0.6 s. Conclusions: At SNUH, the nurse stations and receptions were found to be quite noisy. The ERs were quieter than in the previous studies. The measured reverberation times seemed low enough but some other nurse stations and examination rooms were not satisfactory according to the questionnaire.

The Comparison of hospitalization time of Patients According to Natural Light in Hospital (병실의 자연광 환경에 따른 환자들의 입원기간 비교)

  • Kim, Hyoung-Sup;Kim, Min-Sung;Lee, Ju-Yoon;Song, Kyoo-Dong
    • KIEAE Journal
    • /
    • v.5 no.2
    • /
    • pp.35-41
    • /
    • 2005
  • This study was conducted to identify the effect of daylighting in hospitals on hospitalization time of patients and patients' outcomes in hospitals. Two major variations include orientation of hospital wards and the hospitalization times of various kinds of patients. Patients' data were obtained from two hospitals located in Seoul, Korea. The hospital buildings have north-facing and north-facing wards. The patients were classified according to the types of diseases and the orientation of the patient rooms. Then, statistical T-tests were applied in order to verify if natural light might shorter the hospitalization time of patients. The study also identified the types of diseases that were more responsive to the quantity of natural light in patient rooms. This information may be used as a basis for the development of guidelines for patient rooms in hospitals to achieve more effective healing environments. Likewise, the results may be applied to medical treatment buildings, recreational centers and hospital as well.

A Study of Efficient Floor Planning and Facility Improvement for Physical Therapy Room of Domestic Long-term Hospitals (국내 요양병원의 물리치료실의 효율적 평면계획 및 시설개선에 관한 연구)

  • Chung, Kwang-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.4
    • /
    • pp.5-11
    • /
    • 2011
  • The present study investigated the actual conditions of physical therapy rooms at long-term hospitals in Korea and conducted a comparative analysis to develop an efficient floor plan and facility improvement measures. 1. At hospitals surveyed, physical therapy services were used at a high frequency but they did not have enough space for rehab treatment and long paths of patient flow were found to make patient management inconvenient. Therefore, physical therapy units should be conveniently located both in terms of distance and direction so as to be accessible from patient rooms or wards. The space should be organized in a concentrated layout for efficiency of physical therapy, and floor planning for therapy units should ensure the best possible viewing angle to therapists. 2. With regard to the disease characteristics of patients, many physical therapy rooms were in difficult circumstances because of poor facilities, so they need to secure skilled personnel, supplement apparatuses and equipment and have rooms for functional recovery, hydrotherapy and operation treatment. In addition, each of the curtained or partitioned areas for treatment should be set up with consideration for the amount of space taken up by medical equipment. The area under each bed should be designed for patient convenience so that it can be used as storage space for patient's belongings and shoes. 3. Patients complained about the lack of physical therapy space, resting places or exercise areas and demanded the expansion of rehab programs and facilities. Physical therapy facilities need to be improved for patient privacy and effective natural ventilation. 4. At most of the long-term hospitals surveyed, physical therapy units were found to have small areas and treatment equipment and devices were insufficient compared to the number of patients. Therefore, it is required to secure more space (at least 138.24 sq. meters per 100 beds) and improve facilities for better physical therapy services.

A Study on the Effect of Unit Design for Patient-Centered Care on Family Members and Caregivers - A Case Study of the Intensive Care Unit (ICU) for Patient-Centered Care in the United States (환자중심의료를 위한 병동디자인이 환자가족 및 의료진에 미치는 효과에 대한 연구 - 미국의 환자중심의료를 위한 중환자병동 사례를 중심으로)

  • Choi, Young-Seon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.3
    • /
    • pp.37-45
    • /
    • 2015
  • Purpose: The main objective of this paper is, to evaluate the unit design for patient-centered care and to draw lessons-learned for further improvement. Methods: This study conducted a case study of the intensive care unit, designed to fulfill patient-centered care in the US. It evaluated the effectiveness of the unit by incorporating several study methods such as plan analyses, direct observations through nursing tracking and behavior mapping, and focus group interviews. Results: The major design decision made in this patient-centered unit was the use of patient rooms with designated family areas and distributed nursing stations. Both design features appeared to be a success on a variety of research metrics and outcomes. The study identified that the patient rooms ultimately help family members to spent more time with their loved ones, which leads to increased satisfaction of family members and nurses also report that they generally enjoy the distributed nurses' stations, which provide a comfortable environment to complete their regular lines of work such as charting, monitoring patients, and collaborating with their colleagues. Implications: Certain design features in intensive care units such as patient rooms with designated family areas and distributed nursing stations could appropriately support hospitals to fulfill patient-centered care.