• Title/Summary/Keyword: Patient management system

Search Result 927, Processing Time 0.03 seconds

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

  • PDF

Reproducibility Evaluation of Deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis during radiation therapy for Left Breast cancer patients (좌측 유방암 환자의 방사선치료 중 환자의 호흡과 심장 위치 분석을 통한 Deep inspiration breath-hold(DIBH) 기법의 재현성 평가)

  • Jo, Jae Young;Bae, Sun Myung;Yoon, In Ha;Lee, Ho Yeon;Kang, Tae Young;Baek, Geum Mun;Bae, Jae Beom
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.297-303
    • /
    • 2014
  • Purpose : The purpose of this study is reproducibility evaluation of deep inspiration breath-hold(DIBH) technique by respiration data and heart position analysis in radiation therapy for Left Breast cancer patients. Materials and Methods : Free breathing(FB) Computed Tomography(CT) images and DIBH CT images of three left breast cancer patients were used to evaluate the heart volume and dose during treatment planing system( Eclipse version 10.0, Varian, USA ). The signal of RPM (Real-time Position Management) Respiratory Gating System (version 1.7.5, Varian, USA) was used to evaluate respiration stability of DIBH during breast radiation therapy. The images for measurement of heart position were acquired by the Electronic portal imaging device(EPID) cine acquisition mode. The distance of heart at the three measuring points(A, B, C) on each image was measured by Offline Review (ARIA 10, Varian, USA). Results : Significant differences were found between the FB and DIBH plans for mean heart dose (6.82 vs. 1.91 Gy), heart $V_{30}$ (68.57 vs. $8.26cm^3$), $V_{20}$ (76.43 vs. $11.34cm^3$). The standard deviation of DIBH signal of each patient was ${\pm}0.07cm$, ${\pm}0.04cm$, ${\pm}0.13cm$, respectively. The Maximum and Minimum heart distance on EPID images were measured as 0.32 cm and 0.00 cm. Conclusion : Consequently, using the DIBH technique with radiation therapy for left breast cancer patients is very useful to establish the treatment plan and to reduce the heart dose. In addition, it is beneficial to using the Cine acquisition mode of EPID for the reproducibility evaluation of DIBH.

Psychological burden for legal responsibility of 119 emergency personnels (119구급대원의 법적책임에 대한 심리적 부담감)

  • Lim, Jae-Man;Yun, Seok-Jeong;Lim, Gwan-Su;Kang, Shin-Kap;Choi, Eun-Sook;Seo, Kyung-Hee
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.1
    • /
    • pp.87-96
    • /
    • 2009
  • Purpose : To grasp the mental burden for legal responsibility that rescue members have in the performance of job. Method : Questionnaire was presented to rescue members serving in 2 direct control safety centers of fire station located in Seoul, Daejon, Incheon, Kwangju, Busan, Daegu and Ulsan. Results : 1. Questioned whether they have mental burden for legal responsibility while performing job on the site, the rescue members responded : very burdensome in 38.0%, burdensome in 56.0%, moderate in 4.5%, not burdensome in 1.0%, no burden at all in 0.5%. 2. Questioned on the first aid treat for which they have the most mental burden, the rescue members responded : intubation into trachea laryngeal mask airway(LMA) in 40.4%, automatic external defibrillator in 16.3%, securing vein providing sap(medicine) in 10.8%, basic cardiopulmonary resuscitation in 7.2%, eliminating foreign matters inserted into body in 5.4%, stanching external bleeding and treating injury in 5.4%, fixing extremities and spine by using splint in 1.8%, measuring the symptom of vitality in 1.2%, providing oxygen in 0.0%. 3. Questioned whether experiencing legal problem or firm petition(complaint) raised by patient while serving as rescue members, they responded : experiencing a complaint in 41.6%, experiencing no complaint in 58.4%. Asked to indicate the stress level in the scale of which they suffered when lawsuit or firm petition was raised, 0(weak)-10(strong), they answered 8.8 in average. 4. Questioned whether 119 rescue members put the legal responsibility in case that they cause damage to patients intentionally in performing, they responded to the inquiry 3.66 in average(of 5.00). It represented meaningful differences (F=2.874, p=.024) whether they had license or not. 5. In future, legal action will raise against the rescue member by 99% because of people's rights improvement(63.1%), high expectations for the rescue system(29.5%), non-licensed rescue members(5.1%). Conclusion : It was found that the rescue members had severe mental burden for advanced life support which was investigated to have low enforcement rate in the preceding research, for instance, intubation into trachea securing vein management by using automatic external defibrillator. To improve the qualitative level of rescue service in the fire fighting, it may be required to construct the environment that eliminates the mental burden of rescue members for legal responsibility.

  • PDF

A Systematic Review on the Effects of Robot-Assisted Therapy for Stroke Patient (뇌졸중 환자에서 로봇보조치료 효과에 관한 체계적 고찰)

  • Park, Jin-Hyuk
    • Therapeutic Science for Rehabilitation
    • /
    • v.2 no.2
    • /
    • pp.21-36
    • /
    • 2013
  • Objective : The purpose of this study was to look at a systematic review on the effects of robot-assisted therapy on stroke rehabilitation in upper limbs. Through this comprehensive study, we have to compare the studies. Methods : We systematically examined papers published in journal from June 2012 to September 2012, using EMBASE, MEDLINE, etc. 12 studies(randomized controlled trials) were included in the analyses. Results : Selected 12 studies were Pedro score 2 or more. The primary outcome measure tools including tools for upper extremity function and activities daily of living were used. Through various intervention, Robot-assisted therapy maximizes the effectiveness of intervention. The effects of upper extremity function and functional ability(ADL) by robot-assisted therapy showed significant effect, but no difference exists between the robot-assisted therapy and conventional therapy groups in terms of upper extremity function and functional ability. Conclusions : Robot-assisted therapy has been widely used clinically for stroke patients to maximize the effect had been applied to various interventions. Robot-assisted therapy depending on the methods of intervention showed that the effect of difference. In the future study, the use of robot-assisted therapy applied to a variety of interventions is needed on occupational therapy.

SMITH-MAGENS SYNDROME (SMS) : A CASE REPORT (Smith-Magenis Syndrome (SMS) 환아의 증례 보고)

  • Kim, Eun-Young;Lee, Keung-Ho;Choi, Yeong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.341-347
    • /
    • 2003
  • Smith-Magenis syndrome (SMS) is a clinically recognizable multiple congenital anomaly and mental retardation syndrome caused by an interstitial deletion of chromosome 17 p11.2. Physical features include short stature, characteristic facial appearance: flattened mid-face, down-turned mouth, prominent and often rosy cheeks; prominent jaw in older children and adults, chronic ear infections, hearing impairment, eye problems, including: strabismus (an eye which turns in or out) and myopia (nearsightedness), hoarse voice, short fingers and toes, heart defects or murmurs, problems related to the urinary system, scoliosis (curvature of the spine), an unusual gait (walking pattern), and decreased sensitivity to pain. Behavioral and developmental characteristics include speech delay and articulation problems, developmental delay, learning disability, mental retardation, hyperactivity, self-injury, including: head banging; hand biting; picking at skin, sores and nails; pulling off finger- and toenails; inserting foreign objects into ears, nose, or other body orifices, explosive outbursts, prolonged tantrums, destructive and aggressive behavior, excitability, arm hugging or hand squeezing when excited. This report is the case of a Korean 3-year-3-month old male with Smith-Magenis syndrome referred from local clinic for the treatment of dental caries. The patient was treated by physical restraint after prophylatic administration of antibiotic(Amoxacillin 50mg/kg).

  • PDF

The Trends and Prospects of Health Information Standards : Standardization Analysis and Suggestions (의료정보 표준에 관한 연구 : 표준화 분석 및 전망)

  • Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • Ubiquitous health care system, which is one of the developing solution technologies of IT, BT and NT, could give us new medical environments in future. Implementing health information systems can be complex, expensive and frustrating. Healthcare professionals seeking to acquire or upgrade systems do not have a convenient, reliable way of specifying a level of adherence to communication standards sufficient to achieve truly efficient interoperability. Great progress has been made in establishing such standards-DICOM, IHE and HL7, notably, are now highly advanced. IHE has defined a common framework to deliver the basic interoperability needed for local and regional health information networks. It has developed a foundational set of standards-based integration profiles for information exchange with three interrelated efforts. HL7 is one of several ANSI-accredited Standards Developing Organizations operating in the healthcare arena. Most SDOs produce standards (protocols) for a particular healthcare domain such as pharmacy, medical devices, imaging or insurance transactions. HL7's domain is clinical and administrative data. HL7 is an international community of healthcare subject matter experts and information scientists collaborating to create standards for the exchange, management and integration of electronic healthcare information. The ASTM specification for Continuity of Care Record was developed by subcommittee E31.28 on electronic health records, which includes clinicians, provider institutions, administrators, patient advocates, vendors, and health industry. In this paper, there are suggestions that provide a test bed, demonstration and specification of how standards such a IHE, HL7, ASTM can be used to provide an integrated environment.

  • PDF

Statistical analysis of failures of a medical linear accelerator over ten years (선형가속기의 10년간 관리 자료를 바탕으로 한 통계분석)

  • Ju, Sang-Gyu;Huh, Seung-Jae;Han, Young-Yih;Seo, Jeong-Min;Kim, Won-Kyou;Kim, Tae-Jong;Park, Young-Hwan
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.158-161
    • /
    • 2004
  • In order for better management of a medical linear accelerator, the records of the operational failures of Varian CL2100C over ten years were analyzed. The failures were classified according to the involved functional subunits and each class was rated into three levels depending on operational conditions. The relationship between the failure rate and working ratio was investigated. Among the recorded failures ( total 587 failures), the most frequent failure, which was 20% of the total. was observed in the parts related to the collimation system including monitor chamber. Regrading to the operational conditions, the 2nd level of failures, that temporally interrupted treatments, was the most frequent. The 3rd level of failures, that interrupted treatment for more than several hours, was mostly caused by the accelerating subunit. The average life-time of a Klystron and Thyratron became shorter as the working ratio increased, which was 42 and 83% of the expected values, respectively. Recording equipment problems and failures in detail over a long period of time can provide a good knowledge of equipment function as well as the capability to forecast future failure. More rigorous equipment maintenance is required for old medical linear accelerator to avoid the serious failure in advance, and improve the patient treatment quality.

  • PDF

The Evaluation of Potential Hepatotoxicity by Calcium Channel Blockers, Renin-Angiotensin System Blockade and Diuretics (칼슘채널차단제, 레닌-안지오텐신시스템 차단제, 이뇨제의 잠재적 간독성 평가)

  • Kim, Jae Yun;Lee, Ok Sang;Jung, Sun Hoi;Lee, Hye-Suk;Lee, Chang Ho;Kim, Sang Geon;Lim, Sung Cil
    • Korean Journal of Clinical Pharmacy
    • /
    • v.22 no.4
    • /
    • pp.330-339
    • /
    • 2012
  • Background : Hypertension is treated with both lifestyle modification and pharmacotherapy. The Seventh Report of the Joint National Committee on Detection, Evaluation, and Treatment of High Blood Pressure (JNC-7), published in 2003, provides a streamlined management approach to hypertension for the primary care physician. The JNC-7 is the gold standard also in Korea. According to the JNC-7, special therapeutic considerations are recommended for high-risk individuals with compelling indications. The presence of compelling indications in any given patient should be considered when selecting specific pharmacotherapy to treat hypertension. However, in patients with compelling indications, it is unknown that hepatotoxicity is caused by Calcium Channel Blocker (CCB), one of 1st anti-hypertensive drugs. Now, the CCB is the most used 1st anti-hypertensive drug in Korea Therefore, we evaluated the changes in blood liver function parameters (ALT, AST, Total bilirubin, serum albumin) for the study group. Methods : We randomly collected and retrospectively analyzed Electronic Medical Record data (n=28,788) of patients, and who took calcium channel blockers(non-dihydropyridines; diltiazem, verapamil, dihydropyridines; amlodipine, barnidipine, benidipine, clinidipine, efonidipine, felodipine, isradipine, lacidipine, lercanidipine, nicardipine, nifedipine, nimodipine), with having liver function tests (LFTs) from July 1st 2009 to June 30th 2010 at the Seoul National University Hospital in Korea. Control groups are two antihypertensive agents: RAS blockade (ARB; candesartan, irbesartan, losartan, olmesartan, telmisartan, valsartan, ACE-I; cilazapril, enalapril, fosinopril, imidapril, perindopril, ramipril) and, Diuretics (loop; furosemide, torsemide, thiazide; hydrochlorothiazide[HCTZ], indapamide). Patients not having LFT results at these three standard points of time(baseline, during, medication, and after finishing medication) were excluded. The collected data were analyzed by using the SPSS (Version12.0) and Microsoft Excel (Version2007). Results : 711 patients who were treated CCB (297), RAS blockade (232) or Diuretics (182) monotherapy were selected for the study. In selected patients, liver damage degree(changes of each LFTs value) was higher in diuretics group than other groups, followed by RAS blockade and CCB. In diuretics group's was loop-diuretics group was higher than thiazide-diuretics group. In CCB group, Nondihydropyridine-CCB's damage degree was higher than Dihydropyrine-CCB's that. Conclusions : Despite the limitations due to the retrospective study, among patients with abnormal LFTs, the use of CCBs led to a less liver damage than other 1st anti-hypertensive agents. It can be recommended CCBs as one of the initial treatments of hypertension in patients with liver disease.

The Treatment Strategies of Non-surgical Approach for Dentofacial Asymmetry Patient (치열 안면 비대칭 환자의 비수술적 절충치료의 전략적 접근)

  • Lee, Kyung-Min;Lee, Sang-Min;Yang, Byung-Ho;Yun, Min-Sung;Lee, Ju-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.77-87
    • /
    • 2010
  • Skeletodental asymmetries are common and asymmetric orthodontic treatments are very difficult to correct successfully. The cause of asymmetries can be the skeletal asymmetry, dental, or functional, or combinations of these causes. Skeletodental asymmetries can be the result of congenital factors, such as hemifacial microsomia and environmental factors, such as trauma. Optimal treatment outcome of the severe facial asymmetry requires the orthognathic surgery. Mild asymmetry problem can be treated by only orthodontic treatment. The orthodontic treatment of asymmetry is usually difficult. Facial asymmetry orthodontic treatment are primarily based on proper diagnosis and careful treatment planning. Side effects of asymmetric elastic to treat midline discrepancies are canted occlusal plane, tipped incisors and unesthetic results. In the management of dental arch asymmetries, the clinician should select the appropriate force system and the appliance design necessary to address the asymmetry while minimizing undesirable side effects. This report presents treatment strategies for the treatment of skeletodental asymmetry. In this case report, the clinical case with midline discrepancies treated by optimal mechanics is described. Through diagnosis and strategic treatment mechanics can obtain proper midline correction with minimal side effects.