• Title/Summary/Keyword: Patient evaluation

Search Result 3,043, Processing Time 0.031 seconds

Comparison of Thyroid Doses for Shielding Material Changes in Neck Computed Tomography (Neck CT에서 차폐체 재료 변화에 따른 Thyroid 선량 비교 연구)

  • Kang, Eun Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.65-71
    • /
    • 2019
  • With regard to current Neck CT, Bismuth shielding boards are often being used to reduce exposure to superficial organs such as the thyroid. However, beam hardening often occurs near superficial organs with Bismuth shielding boards and variations in CT Number, Noise, and Uniformity values occur severely. This study looked into the usefulness of shielding boards made from aluminum and silicone that can be easily obtained and have good machinability by comparing them to the existing Bismuth shielding board. An Aluminum 7.3mm and a Silicone 21.5mm were made with shielding ratios similar to that of the Bismuth(0.06 mmPb). TLD (TLD-100) was placed on the thyroid area of the Phantom (RS-108T) and 5 doses were measured for each. To compare image quality, CT Number and Noise variations in axial images of the thyroid area in Neck CT images were compared. Also, variations in CT Number, Noise, and Uniformity were measured in the AAPM phantom images and compared. In the results, when thyroid doses for each shielding board were compared, the Bismuth shielding board showed a 14% reduction, the Silicone 21.5mm showed a 15% reduction, and the Aluminum 7.3mm showed a 13% reduction compared to the Non-Shield. Statistically, there were no significant differences in comparison with the Bismuth shielding board. In CT Number variations of thyroid area images, variations were largest for the Bismuth shielding board. With Uniformity evaluations of the AAPM phantom, the Bismuth shielding board was found unsuitable and the Aluminum 7.3mm and Silicone 21.5mm satisfied the acceptance criteria. Research results show that the Aluminum 7.3mm and Silicone 21.5mm have a similar shielding ratio to the high-priced Bismuth shielding board that is currently being used clinically and in comparison tests of CT Number attenuation coefficient variations, Noise, and Uniformity which are phantom image evaluation items, they proved to be better than Bismuth shielding boards. If various shielding boards are made using aluminum and silicone, sized appropriately for superficial organs, it would be useful in decreasing patient doses.

Chronic Hereditary Tyrosinemia Type I with Novel Mutation in FAH Gene (FAH gene novel mutation을 가진 만성형 Hereditary tyrosinemia 1형)

  • Yang, Sungmin;Choi, Hyo Won;Kang, Yun Koo;Lee, Jin-Sung;Namgoong, Mee Kyung
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.20 no.2
    • /
    • pp.55-62
    • /
    • 2020
  • A 22-month-old girl who had taken iron supplements due to iron deficiency anemia, presented bloody mucoid stool for one month. She had a bruise at the right periorbital area due to minor trauma and hepatosplenomegaly. Laboratory studies showed anemia, thrombocytopenia, elevated alkaline phosphatase (ALP), hypophosphatemia, decreased haptoglobin, hypocomplementemia, negative direct/indirect Coomb's test, normal vitamin D3 level and high PTHi. Wrist x-ray showed no signs of rickets. The abdominal ultrasound showed only accessory spleen. Tandem mass spectrometry was normal. During follow up, bloody stool regressed after seven days of withdrawal of iron supplement and cow milk, and the total CO2 level had been within 15-20 mEq/L with normal anion gap. NGS (next generation sequencing) panel test for evaluation of renal tubular acidosis showed negative results. After low dose steroid and vitamin D supplements under the impression of hypocomplementemic vasculitis, thrombocytopenia, C3/C4, decreased haptoglobin, and elevated ALP level became normal. At 57 months of age, laboratory findings showed elevated liver enzyme, ALP and gamma-glutamyl transferase again. And liver cirrhosis with splenomegaly and diffuse renal disease were reported with abdomen CT scan. Liver biopsy reported macro- and micronodular cirrhosis. Urine organic acid profile showed elevated succinylacetone level. Whole exome sequencing revealed novel compound heterozygous mutations (NM_00137.2:c.107T>C, NM_00137, 2:c.614T>C) in FAH gene and confirmed by Sanger sequencing. Consequently, the patient was diagnosed as chronic hereditary tyrosinemia type I. She started low phenylalanine/tyrosine diet and nitisinone treatment. Our case had presented symptoms very slowly, which is the first case of chronic tyrosinemia type I in South Korea.

A Study on the Characteristics and Consultation Request Type of Inpatients Referred for Depressive Symptoms (우울 증상으로 의뢰된 입원환자의 임상적 특징 및 자문 의뢰 형태에 관한 연구)

  • Yoon, Nara;Ryu, Seung-Ho;Ha, Jee Hyun;Jeon, Hong Jun;Park, Doo-Heum
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.29 no.1
    • /
    • pp.34-41
    • /
    • 2021
  • Objectives : The purpose of this study is to investigate the characteristics of depressive patients who admitted to general hospital. We examined the clinical characteristics of patients who were referred to the Department of Psychiatry as depressive symptoms, according to the type of consultation request, and comparing 'with re-consultation' and 'without re-consultation' groups. Methods : We performed a retrospective chart review of 4,966 inpatients who were referred to the Department of Psychiatry from August 2005 to December 2011. Results : For about 6 years, among the inpatients referred for psychiatric consultation, a total of 647 patients were referred for depressive symptoms, accounting for 13.82% of the total consultations. The average age of depressive patients was 58.6 years, which was higher than the average of 56.4 years of overall patients. Among the depressive patients, 275 patients were included in 'with re-consultation' group and there was no statistically significant difference when comparing 'with re-consultation' group and 'without re-consultation' group. However, there was a difference in the tendency of the two groups in the type of consultation request. 'With re-consultation' group was in the order of frequency of consultation type 3-2-1, whereas the 'without re-consultation' group was in the order of frequency of consultation type 2-3-1. Conclusions : The group of inpatients who were referred for depressive symptoms in general hospital showed the largest proportion of the group of patients referred to the Department of Psychiatry. 'With re-consultation' group had a higher rate of re-consultation due to the occurrence of new symptoms after hospitalization compared to 'without re-consultation' group. Therefore, doctors in each department and psychiatrists should pay attention to the depressive symptoms of inpatients and actively discuss treatment plans to improve the quality of medical services, identify risk factors, and make efforts to intervene early if necessary.

The Validation of a Commercial Testosterone RIA Test Kits (Testosterone RIA 검사 kit 별 유효성 비교평가)

  • Ryu, Hwa-jin;Shin, Seon-yeong;Cho, Seong-uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.38-41
    • /
    • 2022
  • Purpose Testosterone is a steroid hormone synthesized by the Leydig cells of the testes in men, and by the adrenal cortex and ovaries in women. Testosterone production is regulated by luteinzing hormone secreted by the anterior pituitary gland. In this experiment, the effectiveness of testosterone radioimmunoassay (RIA) kits produced by three companies was evaluated and compared in case the production of testosterone kits was stopped or supply problems occurred. Materials and Methods In October 2021, samples were collected from the patients (n=49) who requested the testosterone RIA test. The experiment was conducted by dividing the patient's sample into low concentration (1.0 ng/mL or less), medium concentration (2.0-4.0 ng/mL) and high concentration (6.0 ng/mL or more). The Testosterone RIA test compared and evaluated the validity of Company A kits used in this hospital and those of Company B and C used in other hospitals. The precision, sensitivity, recovery, linearity and correlation were evaluated for each kit. The testosterone RIA test was carried out in accordance with the insert kit manual for each manufacturer. Results As a result of measuring the precision of the intra assay, the Coefficient of Variation (CV) value of the company A kit was high at 11.4% only in the low concentration sample, and in the case of the company B and C kits, the CV value was less than 10% at low, medium, and high concentrations. In the inter-assay precision measurement, the CV value was less than 15% in both A and C kits, but in the case of the B kit, the CV value exceeded 15% at low and medium concentrations. Sensitivity was 0.13 ng/mL for company A, 0.01 ng/mL for company B, and 0.01 ng/mL for company C, and the linearity of all three kits showed excellent linearity. In the case of recovery rate, all of the A, B, and C company kits showed results that were out of 90-110%. In the case of correlation test, when compared with the company A kit currently use in here, the correlation coefficient (R2) value for the company B kit was 0.9508, and for the company C kit was 0.9352 Conclusion As a result, there was a slight difference in precision at the low concentration sample. The correlation test showed an excellent correlation coefficient. However, it was difficult to secure samples of various concentrations because there were not many tests of testosterone requested at this hospital. So, additional experiments should be carried out by acquiring samples of various concentrations on each laboratory later.

A Study on the Cooperation between Medical Care and Law - Focusing on the discussion of the role of clinical practice guideline in Japan - (의료와 사법(司法)의 협력 -일본에서의 진료가이드라인의 역할에 대한 논의를 중심으로-)

  • Song, young-min
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.2
    • /
    • pp.39-65
    • /
    • 2022
  • There are two aspects of clinical practice guidelines that act as non-legal control before medical practice and as legal control standards after medical practice. The essential purpose of clinical practice guidelines is the former, but the latter action cannot be excluded. The clinical practice guidelines are a means of linking law and medical care. The negative perception of clinical practice guidelines that medical professionals' autonomy can be violated by the enactment of clinical practice guidelines is an excessive negative evaluation of clinical practice guidelines. Rather, judicial judgment based on clinical practice guidelines plays a role in respecting the autonomy of medical professionals. In other words, the clinical practice guidelines suppress legal regulations on medical care as much as possible and are based on doctors' professional ethics and self-discipline, and patient awareness and cooperation. In order to establish an ideal relationship of cooperation between doctors and patients, 'medical ethics' must be incorporated as a legal means. Clinical practice guidelines are the most appropriate means for incorporating such medical ethics into legal procedures. The lawyer solves the case with a legal syllogism that establishes a norm and applies facts to it to conclude. For the resolution of medical disputes, Clinical practice guidelines are used to establish norms that doctors should perform for specific diseases, and conclusions are drawn by applying the established norms to specific medical practices. When it is not easy to apply the established norms to specific medical practices, medical judgments by experts, such as emotions, expert testimony, and explanations by expert members, are used. As such, the Law respects the autonomy of medical care even in the establishment of norms and the application of norms. In particular, Clinical practice guidelines prepared independently by the medical community are referred to in establishing norms, which are the prerequisites for legal syllogism. This shows that doctors participate in the formation of precedents and contribute to the formation of norms. The use of clinical practice guidelines in trials is respect and consideration for the autonomy of medical care. Although there may be an aspect in which the autonomy of individual doctors is limited by clinical practice guidelines, it should be considered that the autonomy of doctors as a group is respected. In this way, the clinical practice guidelines play a role in protecting the autonomy of the "medical" group from the logic of the "law."

Space Usage and Satisfaction with Privacy in General Hospital Inpatients (종합병원 입원환자의 공간사용 및 프라이버시 만족도)

  • Choi, In Young;Park, Hey Kyung
    • Korea Science and Art Forum
    • /
    • v.36
    • /
    • pp.391-400
    • /
    • 2018
  • To ensure a user-centered treatment environment, hospital construction needs an approach that is not centered on functional aspects such as efficiency or economic feasibility but on the consideration of needs as reflected in user psychology and behavior. Patients who are physically and psychologically vulnerable experience psychological pressure when they are placed in an unfamiliar environment. Most of existing studies however focus on the evaluation of the physical environment, without paying attention to the psychological or behavioral approach to anxiety and stress that patients may experience in a special environment that a hospital may be to them. This study examines general hospital inpatients to understand the usage of major space available and their satisfaction with privacy. This study provides useful primary information needed for the user-centered design of general hospital for improved patient health and welfare. For the purpose of the study, literature review, site investigation, and survey were conducted. Major functional space and privacy in general hospitals were studied, and the site investigation was performed to identify the plans and their status. Survey was also performed to understand the usage of functional space and satisfaction with such space usage as well as satisfaction with privacy. The findings were as follows: (1) Space usage was rated as average in general. It was found that patients used their rooms and lobby on a daily basis. By age, the usage was highest in the group in their 40s; the usage was relatively lower in the groups in their 30s or younger. (2) Space satisfaction was above average, indicating that patients were fairly satisfied. Satisfaction was highest in the lobby space designed with distinct features. By case, satisfaction was highest in Case B, characterized by its wide horizontal space in the rural settings. (3) Satisfaction with privacy in hospital was average, indicating that the demand for privacy was relatively higher but what patients receive in return was lower than their expectation. It was also found that satisfaction with privacy was a crucial element that affected the overall satisfaction with hospital.

A Study on the Characteristics and Consultation Type of Inpatients Referred for Delirium and Depressive Disorder (섬망 및 우울장애로 자문 의뢰된 입원환자의 임상적 특징 및 의뢰 형태에 관한 연구)

  • Seong min Lee;Seung-Ho Ryu;Jee Hyun Ha;Hong Jun Jeon;Doo-Heum Park
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.31 no.1
    • /
    • pp.10-18
    • /
    • 2023
  • Objectives : The purpose of this study is to investigate the characteristics of patients referred for delirium and depressive disorder and to find direction of improvement of consultation-liason psychiatry in general hospital. Methods : We performed a retrospective computed chart review of the 4,966 inpatients hospitalized at Konkuk University Hospital who were referred to the Department of Psychiatry from August 1, 2005 to December 31, 2011. Results : Depressive disorder shows the order of frequency of consultation type Parallel-Complementary-Mending. Delirium shows the order of frequency of consultation type Mending-Parallel-Complementary. When comparing 'follow up consultation' and 'without follow up consultation' group within the depressive disorder, the proportion of men in the 'follow up consultation' group was higher. In the analysis of the consultation type, the 'follow up consultation' group showed the order of consultation type Parallel-Mending- Complementary, and type Parallel-Complementary-Mending in the 'without follow up consultation' group. When comparing 'follow up consultation' and 'without follow up consultation' group within the delirium, the proportion of the surgical field in the 'follow up consultation' group was higher. In the analysis of the consultation type, both group showed the order of consultation type Mending-Parallel- Complementary. Conclusions : Doctors in each department and psychiatrists should pay attention to delirium symptoms that may occur in surgical inpatients and preventive measures should be taken. Screening tests should be conducted in medical patients to properly evaluate coexisting psychiatric diseases. Risk factors of Delirium and Depressive disorder should be identified from the time of hospitalization, and actively discussing treatment plans and early interventions could improve the quality of medical services.

The Correction Effect of Motion Artifacts in PET/CT Image using System (PET/CT 검사 시 움직임 보정 기법의 유용성 평가)

  • Yeong-Hak Jo;Se-Jong Yoo;Seok-Hwan Bae;Jong-Ryul Seon;Seong-Ho Kim;Won-Jeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2024
  • In this study, an AI-based algorithm was developed to prevent image quality deterioration and reading errors due to patient movement in PET/CT examinations that use radioisotopes in medical institutions to test cancer and other diseases. Using the Mothion Free software developed using, we checked the degree of correction of movement due to breathing, evaluated its usefulness, and conducted a study for clinical application. The experimental method was to use an RPM Phantom to inject the radioisotope 18F-FDG into a vacuum vial and a sphere of a NEMA IEC body Phantom of different sizes, and to produce images by directing the movement of the radioisotope into a moving lesion during respiration. The vacuum vial had different degrees of movement at different positions, and the spheres of the NEMA IEC body Phantom of different sizes produced different sizes of lesions. Through the acquired images, the lesion volume, maximum SUV, and average SUV were each measured to quantitatively evaluate the degree of motion correction by Motion Free. The average SUV of vacuum vial A, with a large degree of movement, was reduced by 23.36 %, and the error rate of vacuum vial B, with a small degree of movement, was reduced by 29.3 %. The average SUV error rate at the sphere 37mm and 22mm of the NEMA IEC body Phantom was reduced by 29.3 % and 26.51 %, respectively. The average error rate of the four measurements from which the error rate was calculated decreased by 30.03 %, indicating a more accurate average SUV value. In this study, only two-dimensional movements could be produced, so in order to obtain more accurate data, a Phantom that can embody the actual breathing movement of the human body was used, and if the diversity of the range of movement was configured, a more accurate evaluation of usability could be made.

Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF

CT Evaluation of Long-Term Changes in Common Bile Duct Diameter after Cholecystectomy (담낭 절제술 후 총담관 직경의 장기 변화에 대한 CT 평가)

  • Sung Hee Ahn;Chansik An;Seung-seob Kim;Sumi Park
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.581-595
    • /
    • 2024
  • Purpose The present study aimed to investigate the frequency and extent of compensatory common bile duct (CBD) dilatation after cholecystectomy, assess the time between cholecystectomy and CBD dilatation, and identify potentially useful CT findings suggestive of obstructive CBD dilatation. Materials and Methods This retrospective study included 121 patients without biliary obstruction who underwent multiple CT scans before and after cholecystectomy at a single center between 2009 and 2011. The maximum short-axis diameters of the CBD and intrahepatic duct (IHD) were measured on each CT scan. In addition, the clinical and CT findings of 11 patients who were initially excluded from the study because of CBD stones or periampullary tumors were examined to identify distinguishing features between obstructive and non-obstructive CBD dilatation after cholecystectomy. Results The mean (standard deviation) short-axis maximum CBD diameter of 121 patients was 5.6 (± 1.9) mm in the axial plane before cholecystectomy but increased to 7.9 (± 2.6) mm after cholecystectomy (p < 0.001). Of the 106 patients with a pre-cholecystectomy axial CBD diameter of < 8 mm, 39 (36.8%) showed CBD dilatation of ≥ 8 mm after cholecystectomy. Six of the 17 patients with long-term (> 2 years) serial follow-up CT scans (35.3%) eventually showed a significant (> 1.5-fold) increase in the axial CBD diameter, all within two years after cholecystectomy. Of the 121 patients without obstruction or related symptoms, only one patient (0.1%) showed IHD dilatation > 3 mm after cholecystectomy. In contrast, all 11 patients with CBD obstruction had abdominal pain and abnormal laboratory indices, and 81.8% (9/11) had significant dilatation of the IHD and CBD. Conclusion Compensatory non-obstructive CBD dilatation commonly occurs after cholecystectomy to a similar extent as obstructive dilatation. However, the presence of relevant symptoms, significant IHD dilatation, or further CBD dilatation 2-3 years after cholecystectomy should raise suspicion of CBD obstruction.